Optical Remote Unit ION™-M17HP/19P (M-cabinet) User's Manual M0145A0A
User’s Manual for ION™-M17HP/19P (M-cab) © Copyright 2011 CommScope, Inc. All rights reserved. Andrew Solutions is a trademark of CommScope, Inc. All information contained in this manual has been revised thoroughly. Yet Andrew Solutions accepts no liability for any omissions or faults. Andrew Solutions reserves the right to change all hard- and software characteristics without notice.
TABLE OF CONTENTS 1. GENERAL 7 1.1. USED ABBREVIATIONS 7 1.2. HEALTH AND SAFETY WARNINGS 8 1.3. ABOUT ANDREW SOLUTIONS 10 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT 11 2. INTRODUCTION 13 2.1. PURPOSE 13 2.2. THE ION-M17HP/19P (INTELLIGENT OPTICAL NETWORK; MMR) 13 3. FUNCTIONAL DESCRIPTION 15 3.1. GENERAL 15 3.2. 3.2.1. 3.2.2. 3.2.3. COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT Components Inside the Unit Fan-Protection Kit Accessories 16 16 17 17 4.
User’s Manual for ION™-M17HP/19P (M-cab) 5. ALARMS 37 5.1. BITE AND ALARMS 37 5.2. HANDLING OF ALARMS 37 5.3. ALARM STATUS 37 5.4. STATUS LED ALARMS 37 5.5. EXTERNAL ALARM INPUTS AND OUTPUTS 38 5.6. TROUBLESHOOTING 40 6. MAINTENANCE 41 6.1. GENERAL 41 6.2. REPLACING THE FAN UNIT 42 6.3. CLEANING THE HEAT SINK 44 7. APPENDIX 45 7.1. ILLUSTRATIONS 45 7.2. 7.2.1. 7.2.2. 7.2.3.
FIGURES AND TABLES figure 3-1 Configuration of an ION-M17HP/19P Remote Unit................................... 15 figure 3-2 Remote Unit, front side, fully RF equipped ............................................... 16 figure 3-3 Remote Unit, rear side, fully RF equipped................................................ 16 figure 4-1 Wall mounting, (metric dimensions).......................................................... 21 figure 4-2 Pole-mounting kit......................................................
User’s Manual for ION™-M17HP/19P (M-cab) For your notes: Page 6 M0145A0A.
1 General 1. GENERAL 1.1.
User’s Manual for ION™-M17HP/19P (M-cab) 1.2. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3.
1 General 12. Before opening the unit, disconnect mains. 13. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 14. This unit complies with European standard EN60950. 15. Make sure the repeater settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 16.
User’s Manual for ION™-M17HP/19P (M-cab) 1.3. ABOUT ANDREW SOLUTIONS Andrew Wireless Systems GmbH based in Buchdorf/ Germany, is a leading manufacturer of coverage equipment for mobile radio networks, specializing in high performance, RF and optical repeaters. Our optical distributed networks and RF repeater systems provide coverage for every application: outdoor use, indoor installations, tunnels, subways and many more.
1 General 1.4. INTERNATIONAL CONTACT ADDRESSES FOR CUSTOMER SUPPORT Americas: Canada United States Andrew Solutions Canada Andrew Solutions, Andrew LLC, A CommScope Company Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Mail 620 North Greenfield Parkway Garner, NC 27529 U.S.A. Phone +1-905-878-3457 (Office) +1-416-721-5058 (Mobile) Phone +1-888-297-6433 Fax +1-905-878-3297 Fax +1-919-329-8950 E-mail Peter.Masih@commscope.com, WIsupport.us@commscope.com E-mail WIsupport.
User’s Manual for ION™-M17HP/19P (M-cab) Europe: United Kingdom France Andrew Solutions UK Ltd CommScope France Mail Unit 15, Ilex Building Mulberry Business Park Fishponds Road Wokingham Berkshire RG41 2GY England Mail Immeuble Le Lavoisier 4, Place des Vosges 92052 Courbevoie France Phone +44-1189-366-792 Phone +33-1 82 97 04 00 Fax +44-1189-366-773 Fax +33-1 47 89 45 25 E-mail WIsupport.uk@commscope.com E-mail WIsupport@commscope.
2 Introduction 2. INTRODUCTION 2.1. PURPOSE Cellular telephone systems transmit signals in two directions between base transceiver station (BTS) and mobile stations (MS) within the signal coverage area. If weak signal transmissions occur within the coverage area because of indoor applications, topological conditions or distance from the transmitter, extension of the transmission range can be achieved by means of an optical distribution system.
User’s Manual for ION™-M17HP/19P (M-cab) The ION-M17HP/19P is available in a multi-band configuration supporting 1900 MHz and 1700/2100 MHz in parallel and with extension option 700 MHz additionally. It has been specifically tested and optimized for GSM, EDGE, CDMA2000, EV-DO, WCDMA, HSPA+ and OFDM. Furthermore it is provisioned for future improvements to the modulation and frequency bands. The ION is easily set-up and supervised via a graphical user interface (GUI).
3 Functional Description 3. FUNCTIONAL DESCRIPTION 3.1. GENERAL The following figure shows the configuration of an ION-M17HP/19P Remote Unit.
User’s Manual for ION™-M17HP/19P (M-cab) 3.2. COMPONENTS OF THE ION-M17HP/19P REMOTE UNIT The actual configuration of the Remote Unit can be seen at the configuration list which is part of the delivery. 3.2.1. Components Inside the Unit The following figures show exemplary views of a fully equipped ION-M17HP/19P Remote Unit – except for the fan housing without cover – to illustrate the individual components.
3 Functional Description 3.2.2. Fan-Protection Kit In order to protect the fan unit (e.g. against rain), a protective cover to be mounted over the air inlet is delivered with the unit. For more details see section 4.1.4 Mounting of Fan Protection. Mounting of the fan-protection kit is only mandatory for outdoor applications, however, not mandatory for indoor applications. 3.2.3. Accessories For the accessories available for the Remote Unit, e.g.
User’s Manual for ION™-M17HP/19P (M-cab) For your notes: Page 18 M0145A0A.
4 Commissioning 4. COMMISSIONING 4.1. MECHANICAL INSTALLATION 4.1.1. General Read the health and safety warnings in section 1.2 Health and Safety Warnings. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. 2. It is recommended only to use the mounting hardware delivered by the supplier.
User’s Manual for ION™-M17HP/19P (M-cab) 7. A spacing of 40 mm (1.58 inch) around the unit is required. 8. To ensure sufficient airflow when mounting the unit in enclosed spaces, two lid openings (one for the air inlet and the other for the air outlet) have to be provided. Do not block these air inlets and outlets when mounting the Remote Unit. The size of each opening must equal at least 12 x 12 cm (144 cm2). Make sure, too, there is no thermal short circuit between the air inlet and air outlet.
4 Commissioning 4.1.2. Wall-Mounting Procedure Check the suitability of the wall-mounting kit and the wall. Mark the position of the drilling holes (for measurements refer to figure 4-1 Wall mounting). Drill four holes at the marked positions and insert dowels *. Wall mounting with active cooling kit 4.0 0.50 122 ± 0.50 80 ± 0.50 9 4 18 Use a cap nut or lock nut to screw the four dowel screws into the dowels and put the distance tubes over the screws. 796 ± 1.
User’s Manual for ION™-M17HP/19P (M-cab) 4.1.3. Pole-Mounting Procedure Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a column or other similar structures. Additional hardware must be used for this type of installation. Such a pole-mounting kit could include two threaded rods M8, two U-beams and mounting material like bolts and nuts. figure 4-2 Pole-mounting kit Use the screw bands to fasten the two U-beams to the pole as illustrated in figure 4-3 Pole mounting.
4 Commissioning TESPA screw band, stainless, 11 mm Optical Remote Unit Washer DIN 125 Form B Ø 8.0 Lock washer for M8.
User’s Manual for ION™-M17HP/19P (M-cab) 4.1.4. Mounting of Fan Protection Since the fan protection is required for the outdoor usage of a stand-alone Remote Unit, the mounting of this optional equipment is also described in this manual. To install the protective cover of the fan protection kit, first unscrew the four screws with the respective lock washers from the cover of the air inlet of the Remote Unit, and instead, screw in the four spacing bolts M4.0x30 with the four lock washers M4.
4 Commissioning 4.2. ELECTRICAL INSTALLATION 4.2.1. General Read the health and safety warnings in section 1.2 Health and Safety Warnings. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2. Ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3.
User’s Manual for ION™-M17HP/19P (M-cab) 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection), depending on the individual application, in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 4.2.2.
4 Commissioning 4.2.3. Grounding Grounding must be carried out. Connect an earth-bonding cable to the grounding connection provided at the outside of the Remote Unit (see section 4.2.2 Connections). Do not use the grounding connection to connect external devices. figure 4-6 Grounding bolt with loosened hex nut figure 4-7 Grounding bolt, schematic view After loosening the hex nut, connect the earth-bonding cable between the two washers as illustrated in the figures above.
User’s Manual for ION™-M17HP/19P (M-cab) figure 4-8 AC mains plug For the AC power supply connection, a minimum cross section of 1.5 mm2 is required. Each wire must observe the applicable national regulations regarding loop impedance, voltage drop, and methods of installation. Make sure to connect the correct voltage to the unit. ) Note: * Do not connect or disconnect the power cord at the mains connector while power is on.
4 Commissioning Do not use a tool (e.g. pair of pliers) to tighten the N-type antenna connectors as it might cause damage to the connector and lead to a malfunction of the Remote Unit. It is sufficient to tighten the N-type antenna connectors by hand. ) Note: Directly connect the base station signal to the Master Unit using a coaxial cable to avoid coupling another signal into the system in the DL direction than the single wanted signal transmitted by the base station. 4.4.
User’s Manual for ION™-M17HP/19P (M-cab) System attenuation and attenuation of optical components must be determined. Fiber-cable connectors have to be of the same type (E2000APC) as the connectors used for the unit. The fiber-optic cables are connected to the optical transceiver. Angled connectors are not compatible with straight optical connectors; non-compatibility of connectors will result in permanent damage to both connectors.
4 Commissioning For plug assembly, observe the following instruction: 1. Pass one or two contacts through the backshell and the clamp ring. 2. Place the contact(s) on the lower insulation body by pushing the groove of the contact into the cavity. If there is only one contact, cavity A must be used. * 3. Then, mount the upper insulation body on the lower insulation body. ** Upper insulation body Cavity B Cavity A 4. Bring the insulator into the plug.
User’s Manual for ION™-M17HP/19P (M-cab) 7. Bring the plastic ring over the cable(s), push it into the backshell and compress the seals and plastic ring by screwing the clamp ring tight (no gap) using a spanner with opening 20. *** Screw tight until gap is closed 8. Connect the plug to the optical-fibre 9. To lock the connector, push the black connector of the Remote Unit, again locking ring forward.**** by fitting a stamp on the plug into the groove of the connector.
4 Commissioning Protective plug Fiber cable Ring 3/4 Reducer Screw the reducer to the protective plug backshell without any gap! Coupling Place the appropriate seal parts (with) one groove for one contact or two grooves for two contacts) over the cable(s) and push them into the backshell! Protective tube Push the fiber-optic cable carefully through the tube until it comes out at the other end.
User’s Manual for ION™-M17HP/19P (M-cab) 4.5. COMMISSIONING Read the health and safety warnings in section 1.2 Health and Safety Warnings. Keep these guidelines in mind before continuing to the instructions for commissioning: Do not operate the Remote Unit without terminating the antenna connectors. The antenna connectors may be terminated by connecting them to their respective antennas or to a dummy load.
4 Commissioning Commissioning an ION-M Remote Unit Manual for Remote Unit Philips screwdriver Mounting kit Spanner, size 13 mm Drilling machine Dowels Screw driver Screw driver Spanner, size 13 mm Start Preperation Unpack RU, RU accessories and mounting kit. Mechanical installation Fasten wall or pole mounting kit to wall or pole. Mechanical installation Mount RU to mounting kit, ensure suffient air flow and avoid thermal short circuits.
User’s Manual for ION™-M17HP/19P (M-cab) LED on? No Check power switch inside RU (RUs with door). Check mains cabling. Check mains power. Yes LED status Red Internal Error Change power supply (RUs with a door). Reduce environmental temperature. Eliminate thermal short circuit. Disconnect and connect mains. Fans should run. If not, replace the fans at RU.
5 Alarms 5. ALARMS 5.1. BITe AND ALARMS The Built-In Test (BITe) concept comprises the monitoring of the power supplies, the power amplifiers and the optical interface. All alarms occurring can be checked via software at the Master Unit. 5.2. HANDLING OF ALARMS A message is transmitted to the Master Unit when the software acknowledges a valid alarm. A new alarm message will not be repeated if the reason for the alarm is cleared or if the alarm continues.
User’s Manual for ION™-M17HP/19P (M-cab) Red Status LED off Alarms directly related to RU: Change power supply (RUs with door). Power 28 V Replace the affected Remote Unit. Reduce environmental temperature. Temperature Eliminate thermal short circuit. Disconnect and connect mains. Fans Fan should run. If not, replace the fans at RU. I²C Disconnect and connect mains. Optical alarm Tx Exchange RU. Amplifier “Power (MU: Change amplifier setting at MU Down” controller).
5 Alarms The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an alarm they are high active (5 V). They can be used to monitor alarms with an external alarm indicator. The +28 V pin (for its location see figure 5-2 Flange connector, 7 poles) is protected by a 500 mA thermoswitch. In case of exceeding this current between pin 7 and GND and/or in case of a failure of the VSWR module, the thermoswitch turns into a highresistive status. In this case no fuse needs to be replaced.
User’s Manual for ION™-M17HP/19P (M-cab) 5.6. TROUBLESHOOTING The status of the Remote Unit can be checked via the Master Unit (for details please refer to the software manual of the Master Controller). Locally, the status can be checked at the LED, see section 5.4 Status LED Alarms. Page 40 M0145A0A.
6 Maintenance 6. MAINTENANCE 6.1. GENERAL Read the health and safety warnings in section 1.2. ) Note: The Remote Unit does not require preventative maintenance measures. ) Note: To prevent malfunctions of the cooling system due to dirt or pollution, it is recommended to clean the heat sink at regular intervals. These cleaning intervals depend mainly on the location of the Remote Unit and the corresponding degree of pollution.
User’s Manual for ION™-M17HP/19P (M-cab) 6.2. REPLACING THE FAN UNIT Replacement of the fan unit is not required as a preventative measure. Only if an alarm indicates a malfunctioning of a fan must the unit be exchanged. ) Note: Please observe that the fan unit can only be replaced as a whole. Do not remove the fans separately. Read the health and safety warnings in section 1.2 as well as the instructions in section 6.1 General before starting with the replacement. 1. Switch off the Remote Unit.
6 Maintenance 5. To mount the new fan unit, re-connect the earth-bonding cable and the fan connector (see step 4). Then, place the fan unit back into its original position and fasten it tight as shown below: 6. Screw the whole fan unit to the cabinet with the four tallow-drop screws M4x8 (see step 2). In order not to exceed the specified torque of 330 Ncm, use an appropriate tool.
User’s Manual for ION™-M17HP/19P (M-cab) 6.3. CLEANING THE HEAT SINK ) Note: Read the health and safety warnings in section 1.2 Health and Safety Warnings as well as the instructions in section 6.1 General before starting with the replacement procedure. Then, proceed as follows: 1. Switch off the Remote Unit. For the following procedure ensure that mains has been disconnected before! 2. Remove the fan plate with the fan unit 3. Use compressed air (max.
7 Appendix 7. APPENDIX 7.1.
User’s Manual for ION™-M17HP/19P (M-cab) 7.2. SPECIFICATIONS 7.2.1. Electrical Specifications Electrical Mains power 100 Vac to 240 Vac Power supply max. temp., fully loaded 900 watts Power consumption room temp.
7 Appendix 1900 MHz UL 1850 to 1915 MHz Frequency range DL 1930 to 1995 MHz Number of carriers 1 2 4 8 GSM 43 dBm 40 dBm 37 dBm 34 dBm RF output power per CDMA 43 dBm 40 dBm 37 dBm 34 dBm carrier 2) UMTS 43 dBm 40 dBm 37 dBm 34 dBm 4) LTE 43 dBm 40 dBm 37 dBm 34 dBm Spurious emission <-13 dBm / 1 MHz DL output tolerance over frequency ±1 dB DL output tolerance over temperature ±0.5 dB 3) ICP3 optimized NF optimized UL Input ICP3 -12 dBm -18 dBm 7 dB 4.5 dB UL Noise figure (NF) 5) 11 dB max. 6 dB max.
User’s Manual for ION™-M17HP/19P (M-cab) 7.2.3. Environmental and Safety Specifications ) Note: For detailed information, please refer to the Environmental and Safety Specifications leaflet of the supplier, related to ETS 300 019 (European Telecommunication Standard). Operating temperature range RF part Ingress protection Fan part -33° C to +50° C IP67 IP55 All data is subject to change without notice. Page 48 M0145A0A.
7 Appendix 7.3. SPARE PARTS The following lists contain all parts available for the Remote Unit. The configuration of the delivered unit meets the requirements of the customer and can differ depending on the state of the delivery. Maintenance of the ION-M17HP/19P should be performed on an FRU (Field Replaceable Unit) basis only. Do not damage the warranty labels on the components, as this voids the warranty.
User’s Manual for ION™-M17HP/19P (M-cab) For your notes: Page 50 M0145A0A.
8 Index 8. INDEX A H Abbreviations.......................................................... 7 Address of Andrew Wireless Systems GmbH....... 12 Alarms Alarm Status .................................................... 37 Bite and Alarms ............................................... 37 External Inputs........................................... 38, 39 Handling of Alarms .......................................... 37 List ................................................................... 40 Outputs ......