IN ST A L LATI O N & H A RDW A RE R EFERE NCE M A N U A L M O DE RO X ® S E R I ES TO U C H PA N E L S MXT-2000XL-PAN 20.3" MODERO X SERIES PANORAMIC TABLETOP TOUCH PANEL MXD-2000XL-PAN-P 20.3" MODERO X SERIES PORTRAIT WALL MOUN T TOUCH PANEL MXD-2000XL-PAN-L 20.3" MODERO X SERI ES LANDSCAPE WALL MOUNT TOUCH PANEL MXT-1900L-PAN 19. 4" MODER O X SERI ES P ANOR AMI C TAB LE TOP TOUCH PA NEL MXD-1900L-PAN-P 19.4" MODERO X SERIES PORT RAIT WALL MOUNT TOUCH PANEL MXD-1900L-PAN-L 19.
IMPORTANT SAFETY INSTRUCTIONS 1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLLOW all instructions. 5. DO NOT use this apparatus near water. 6. CLEAN ONLY with dry cloth. 7. DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
ESD WARNING To avoid ESD (Electrostatic Discharge) damage to sensitive components, make sure you are properly grounded before touching any internal materials. When working with any equipment manufactured with electronic devices, proper ESD grounding procedures must be followed to make sure people, products, and tools are as free of static charges as possible. Grounding straps, conductive smocks, and conductive work mats are specifically designed for this purpose.
EU COMPLIANCE INFORMATION: Eligible to bear the CE mark; Conforms to European Union Low Voltage Directive 2006/95/EC; European Union EMC Directive 2004/108/EC; European Union Restriction of Hazardous Substances Recast (RoHS2) Directive 2011/65/EU; European Union WEEE (recast) Directive 2012/19/EU; European Union Radio and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC. You may obtain a free copy of the Declaration of Conformity by visiting http://www.amx.com/techcenter/certifications.asp.
Table of Contents Table of Contents Modero X Series (G4) Touch Panels ................................................................. 8 Overview ............................................................................................................................ 8 Multi-Functional Sleep Button........................................................................................... 9 Powering the Panel On/Off ........................................................................................
Table of Contents MXD-430 - 4.3” X Series Panels ......................................................................36 MXD-430 4.3" Modero X Series Wall/Flush Mount Touch Panel .................................... 36 MXD-430 Specifications ....................................................................................................................... 36 Installing Tabletop (MXT) Panels ...................................................................39 MXT-2000XL-PAN / MXT-1900L-PAN ..........
Table of Contents Upgrading Firmware .......................................................................................67 Overview ......................................................................................................................... 67 Downloading Firmware Updates From www.amx.com .................................................. 67 Upgrading Firmware via USB Flash Drive.......................................................................
Modero X Series (G4) Touch Panels Modero X Series (G4) Touch Panels Overview This new generation of G4 touch panels is built for usability offering edge-to-edge capacitive touch glass with multi-touch capabilities. It features advanced technology empowering users to operate AV equipment seamlessly, while providing the ultimate in audio and video quality. The distinctive appearance will complement even the most sophisticated meeting facilities and homes. FIG.
Modero X Series (G4) Touch Panels Modero X Series Touch Panels (Cont.) Name FG# Description X Series - No Comm Panels: The X Series - No Comm Panels do not have camera, microphone, NFC or Bluetooth capability. Otherwise, they have all of the functionality of the standard Modero X Series panels. MXT-2000XL-PAN-NC FG5968-32 No Comm 20.3" Modero X Series Panoramic Tabletop MXD-2000XL-PAN-P-NC MXD-2000XL-PAN-L-NC Portrait: FG5968-33 Landscape: FG5968-34 No Comm 20.
Modero X Series (G4) Touch Panels Conf iguration and Programming X Series touch panels are equipped with a Settings menu that provides the ability to configure various features on the panels. To access the Settings menu, press and hold the Sleep button, and select Settings. NOTE: Unlike previous G4 touch panels, Modero X Series G4 touch panels do not have separate Setup and Protected Setup pages. All touch panel settings and functionality are now controlled through one Settings menu.
Modero X Series (G4) Touch Panels When using an NFC device with the X Series panels, you should align your device’s antenna with the center of the touch panel’s antenna (FIG. 4). NFC Sensor NFC Sensor NFC Sensor FIG. 4 NFC antenna location (Tabletop, Landscape and Portrait layouts) NOTE: To facilitate NFC antenna access, consider adding an icon to the panel’s page(s), pointing to the location of the antenna on the panel.
Modero X Series (G4) Touch Panels Stop Random / A-Z Previous image Pause/Resume Timer Next image Counter FIG. 5 Picture View Configuration Popup Menu Preview Mode and Normal Mode Picture View has two modes: Preview Mode and Normal Mode. Preview Mode allows the user to configure Picture View. Once a USB drive containing images is inserted into the panel, the images will begin to display. Touching any place on the display will result in the configuration popup to slide from the bottom of the display.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXT/D-2000XL-PAN - 20.3" X Series Panels MXT-2000XL-PAN (Tabletop) NFC Sensor Sleep Button USB Ports (2) Cable Slot FIG. 6 MXT-2000XL-PAN - Front View MXT-2000XL-PAN Specif ications MXT-2000XL-PAN Specif ications DIMENSIONS (HWD) 9 3/16" x 20 3/8" x 5 7/8" (235 mm x 519 mm x 150 mm) WEIGHT 12.2 lbs (5.53 Kg) POWER CONSUMPTION • Full-On: 32W (13.5V , 2.4 A) • Standby: 3.10 W (13.5V , 0.27 A) • Start-Up Inrush Current: 4.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXT-2000XL-PAN Specif ications (Cont.) MEMORY • SDRAM: 512 MB • Flash: 4 GB • Maximum Project Size: 2.4 GB flash available to user COMMUNICATIONS • Ethernet: 10/100 port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (3) USB host 2.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXT-2000XL-PAN Specif ications (Cont.) INCLUDED ACCESSORIES • • • • Locking 2-pin Phoenix mate (41-0002-SA) MXA-USB-C, USB Port Cover Kit, Modero X/S Series Touch Panel (FG5968-18) HPG-10-10K, 3/4" Mini-Grommet (FG570-01) MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) OPTIONAL ACCESSORIES • • • • • • • • • MXA-STMK-20, Secure Table Mount Kit, 20.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXD-2000XL-PAN Specif ications (Cont.) EXTERNAL POWER SUPPLY REQUIRED Requires one of these AMX power sources (not included): • PSN4.4 Power Supply, 4.4 A, 3.5 mm Phoenix, 13.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXD-2000XL-PAN Specif ications (Cont.) VIDEO • Supported Video Codecs, Landscape Model (FG5968-11): MPEG-2-TS: MPEG-2 Main Profile@High Level up to 720p at 25 fps (decode only) MPEG-2-TS: H.264 High Profile@Layer 4, AAC-LC up to 720p at 25 fps (encode/decode) MJPEG up to 720p at 25 fps (decode only) • Supported Video Codecs, Portrait Model (FG5968-05): MPEG-2-TS: MPEG-2 Main Profile@High Level up to 720p at 25 fps (decode only) MPEG-2-TS: H.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXD-2000XL-PAN Specif ications (Cont.) OPTIONAL ACCESSORIES • • • • • • • • • • MXA-RMK-20 Modero X Series Rack Mount Kit (FG5969-60) MXA-FMK-20 Flush Mount Kit for 20.3" Modero X Series Wall Mount Touch Panels (FG5968-68) MXA-MP, Modero X/S Series Multi Preview (FG5968-20) MXA-MPL Modero X/S Series Multi Preview Live (FG5968-10) PSN4.4, Power Supply, 4.4 A, 3.5 mm Phoenix, 13.
MXT/D-1900L-PAN - 19.4" X Series Panels MXT/D-1900L-PAN - 19.4" X Series Panels MXT-1900L-PAN (Tabletop) NFC Sensor Sleep Button USB Ports (2) Cable Slot FIG. 8 MXT-1900L-PAN - Front View MXT-1900L-PAN Specif ications MXT-1900L-PAN Specif ications DIMENSIONS (HWD) 7" x 20 3/8" x 5 5/16" (177 mm x 519 mm x 135 mm) WEIGHT 9.4 lbs (4.26 Kg) POWER CONSUMPTION • Full-On: 32W (13.5V , 2.4 A) • Standby: 3.10 W (13.5V , 0.27 A) • Start-Up Inrush Current: 4.
MXT/D-1900L-PAN - 19.4" X Series Panels MXT-1900L-PAN Specif ications (Cont.) COMMUNICATIONS • Ethernet: 10/100 port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (3) USB host 2.
MXT/D-1900L-PAN - 19.4" X Series Panels MXT-1900L-PAN Specif ications (Cont.) OPTIONAL ACCESSORIES • • • • • • • • • MXA-STMK-19, Secure Table Mount Kit, 19.4" Modero X Tabletop (FG5968-65) MXA-MP, Modero X/S Series Multi Preview (FG5968-20) MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) PSN4.4, Power Supply, 4.4 A, 3.5 mm Phoenix, 13.
MXT/D-1900L-PAN - 19.4" X Series Panels MXD-1900L-PAN Specif ications (Cont.) CERTIFICATIONS • • • • • • • • • FCC Part 15 Class B CE EN 55022 CE EN 55024 CE EN 60950-1 IEC 60950-1 C-Tick CISPR 22 Class B IC UL 60950-1 RoHS/WEEE compliant TOUCH SCREEN DISPLAY • Display Type: TFT Active Matrix Color LCD with In-plane Switching Technology (IPS) • Display Size (WH) Landscape: 20.4" x 6.9" (519 mm x 175 mm), 20.4" (518 mm) diagonal Portrait: 6.9" x 20.4" (175 mm x 519 mm), 20.
MXT/D-1900L-PAN - 19.4" X Series Panels MXD-1900L-PAN Specif ications (Cont.) VIDEO • Supported Video Codecs, Landscape Model (FG5968-12): MPEG-2-TS: MPEG-2 Main Profile@High Level up to 720p at 25 fps (decode only) MPEG-2-TS: H.264 High Profile@Layer 4, AAC-LC up to 720p at 25 fps (encode/decode) MJPEG up to 720p at 25 fps (decode only) • Supported Video Codecs, Portrait Model (FG5968-06): MPEG-2-TS: MPEG-2 Main Profile@High Level up to 720p at 25 fps (decode only) MPEG-2-TS: H.
MXT/D-1900L-PAN - 19.4" X Series Panels MXD-1900L-PAN Specif ications (Cont.) OPTIONAL ACCESSORIES • • • • • • • • • • MXA-FMK-19 Flush Mount Kit, 19.4" Modero X Wall Mount (FG5968-69) MXA-RMK-19 Modero X Series Rack Mount Kit (FG5969-61) MXA-MP, Modero X/S Series Multi Preview (FG5968-20) MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) PSN4.4, Power Supply, 4.4 A, 3.5 mm Phoenix, 13.
MXT/D-1000 - 10.1" X Series Panels MXT/D-1000 - 10.1" X Series Panels MXT-1000 (Tabletop) NFC Sensor Sleep Button USB Ports (2) FIG. 10 MXT-1000 Touch Panel MXT-1000 Specif ications MXT-1000 Specif ications DIMENSIONS (HWD) 6 7/8" x 9 7/8" x 4 7/8" (174 mm x 252 mm x 124 mm) WEIGHT 3.0 lbs (1.36 Kg) POWER CONSUMPTION • • • • EXTERNAL POWER SUPPLY REQUIRED Optimal performance requires use of one of the following AMX PoE power supplies (not included): • PS-POE-AF-TC, PoE Injector, 802.
MXT/D-1000 - 10.1" X Series Panels MXT-1000 Specif ications (Cont.) COMMUNICATIONS • Ethernet: 10/100 Auto MDI-X port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (2) USB host 2.
MXT/D-1000 - 10.1" X Series Panels MXT-1000 Specif ications (Cont.) OPTIONAL ACCESSORIES • • • • • • • • • • MXA-STMK-10, Secure Table Mount Kit, 10.1" Modero X Tabletop (FG5968-66) MXA-MP, Modero X/S Series Multi Preview (FG5968-20) MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) PS-POE-AF-TC, PoE Injector, 802.
MXT/D-1000 - 10.1" X Series Panels MXD-1000 Specif ications (Cont.) CERTIFICATIONS • • • • • • • • UL 60950-1 FCC Part 15 Class B C-Tick CISPR 22 Class B CE EN 55022, EN 55024 and EN 60950-1 IEC 60950-1 IC IEC/EN-60950 RoHS/WEEE compliant TOUCH SCREEN DISPLAY • Display Type: TFT Active Matrix Color LCD with In-plane Switching Technology (IPS) • Display Size (WH) Landscape: 9.9" x 6.7" (252 mm x 170 mm), 12.0" (304 mm) diagonal Portrait: 6.7" x 9.9" (170 mm x 252 mm), 12.
MXT/D-1000 - 10.1" X Series Panels MXD-1000 Specif ications (Cont.) VIDEO • Supported Video Codecs, Landscape Model (FG5968-13): MPEG-2-TS: MPEG-2 Main Profile@High Level up to 720p at 25 fps (decode only) MPEG-2-TS: H.264 High Profile@Layer 4, AAC-LC up to 720p at 25 fps (encode/decode) MJPEG up to 720p at 25 fps (decode only) • Supported Video Codecs, Portrait Model (FG5968-07): MPEG-2-TS: MPEG-2 Main Profile@High Level up to 720p at 25 fps (decode only) MPEG-2-TS: H.
MXT/D-1000 - 10.1" X Series Panels MXD-1000 Specif ications (Cont.) OPTIONAL ACCESSORIES • • • • • • • • • • • MXA-FMK-10, Flush Mount Kit, 10" Modero X Wall Mount (FG5969-62) MXA-RMK-10, Modero X Series Rack Mount Kit (FG5969-62) MXA-MP, Modero X/S Series Multi Preview (FG5968-20) MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) PS-POE-AF-TC, PoE Injector, 802.
MXT/D-700 - 7" X Series Panels MXT/D-700 - 7" X Series Panels MXT-700 (Tabletop) NFC Sensor Sleep Button USB Ports (2) FIG. 12 MXT-700 touch panel MXT-700 Specif ications MXT-700 Specif ications DIMENSIONS (HWD) 5" x 7 5/16" x 4 1/8" (126 mm x 187 mm x 105 mm) WEIGHT 1.8 lbs (0.82 Kg) POWER CONSUMPTION • • • • EXTERNAL POWER SUPPLY REQUIRED Optimal performance requires use of one of the following AMX PoE power supplies (not included): • PS-POE-AF-TC, PoE Injector, 802.
MXT/D-700 - 7" X Series Panels MXT-700 Specif ications (Cont.) COMMUNICATIONS • Ethernet: 10/100 Auto MDI-X port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (2) USB host 2.
MXT/D-700 - 7" X Series Panels NOTE: The MXT-700-NC (FG5968-27) "No Comm" touch panel does not have camera, microphone, NFC or Bluetooth capability; otherwise it has all of the functionality of the MXT-700. Touch Panel Aspect Ratio While the touch panel screen physical dimensions fall between 16:9 and 16:10, any incoming video stream can be scaled to 16:9 if needed. This may lead to some letter boxing around the video in some cases.
MXT/D-700 - 7" X Series Panels MXD-700 Specif ications (Cont.) TOUCH SCREEN DISPLAY • Display Type: TFT Active Matrix Color LCD with Fringe Field Switching (FFS) - Wide Viewing Angle Technology • Display Size (WH) Landscape: 7.3" x 4.8" (186 mm x 122 mm), 8.8" (222 mm) diagonal Portrait: 4.8" x 7.3" (122 mm x 186 mm), 8.8" (222 mm) diagonal • Viewable Area (WH) Landscape: 6.05" x 3.54" (154 mm x 90 mm), 7.0" (178 mm) diagonal Portrait: 3.54" x 6.05" (90 mm x 154 mm), 7.
MXT/D-700 - 7" X Series Panels MXD-700 Specif ications (Cont.) FRONT PANEL COMPONENTS • Light Sensor: Photosensitive light detector for automatic adjustment of the panel brightness • Proximity Detector: Max range = ~3', typ range = ~1', FOV = ~10 degrees • Sleep Button: Sleep button to activate sleep mode and powering off. Also provides access to setup pages (can be disabled) CONNECTIONS • Ethernet: 10/100 Auto MDI-X port, RJ-45 connector through cable extension • USB: (2) USB host 2.
MXD-430 - 4.3” X Series Panels MXD-430 - 4.3” X Series Panels MXD-430 4.3" Modero X Series Wall/Flush Mount Touch Panel Left LED Right LED Sleep Button USB Port RJ45 Port NFC Sensor front rear FIG. 14 MXD-430 MXD-430 Specif ications MXD-430 Specif ications DIMENSIONS (HWD) Portrait: 4 7/8" x 3 1/4" x 2 3/8" (120 mm x 82 mm x 61 mm) WEIGHT 0.75 lbs (.
MXD-430 - 4.3” X Series Panels MXD-430 Specif ications (Cont.) MEMORY • SDRAM: 512 MB • Flash: 4 GB • Maximum Project Size: 2.4 GB flash available to user COMMUNICATIONS • Ethernet: 10/100 Auto MDI-X port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (1) USB host 2.
MXD-430 - 4.3” X Series Panels MXD-430 Specif ications (Cont.) OPTIONAL ACCESSORIES • • • • • • • • • • MXA-FMK-43, Flush Mount Kit for 4.3" Modero X Series Wall Mount Touch Panel (FG5968-72) MXA-MP, Modero X/S Series Multi Preview (FG5968-20) MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) PS-POE-AF-TC, PoE Injector, 802.
Installing Tabletop (MXT) Panels Installing Tabletop (MXT) Panels MXT-2000XL-PAN / MXT-1900L-PAN Detailed specifications drawings for the MXT-2000XL-PAN and MXT-1900L-PAN are available to download from www.amx.com. Connector Locations - MXT-2000XL-PAN / MXT-1900L-PAN Two Type A USB ports are located on the rear right corner of the panel (FIG. 15). USB peripherals (i.e. mouse, keyboard) may be connected to either of the two USB ports on the rear of the device. Note that FIG.
Installing Tabletop (MXT) Panels MXT-1000 / MXT-700 Detailed specifications drawings for the MXT-1000 and MXT-700 are available to download from www.amx.com. Connector Locations - MXT-1000/MXT-700 Two Type A USB ports are located on the rear right corner of the panel (FIG. 18). USB peripherals (i.e. mouse, keyboard) may be connected to either of the two USB ports on the rear of the device.
Installing Tabletop (MXT) Panels Ethernet Cable Clamp Connector FIG. 20 Bottom of the MXT-700/1000 NOTE: The minimum diameter hole through which the Ethernet cable may pass is 0.50" (1.27 cm). To disconnect and reconnect the Ethernet cable on the MXT-700 and MXT-1000 to allow use of a hole smaller than 1.00” in diameter: 1. On a soft surface, turn the MXT-1000 face-down to access the bottom of the device. 2. Remove the clamp holding the Ethernet cable (FIG. 20). 3.
Installing Wall-Mount (MXD) Panels Installing Wall-Mount (MXD) Panels A Note About Wall and Rack Installation Some products are installed in areas of differing temperature and cooling methodologies. These include products installed in walls, racks, cabinets, etc. Those areas may have different temperatures and/or cooling approaches that must be taken into consideration to maintain the product within the specified operating temperature. AMX DEVICE FIG.
Installing Wall-Mount (MXD) Panels Installation Recommendations During any installation, a lack of ventilation may produce conditions that may adversely affect the device’s operation. In these circumstances, special care must be made to make sure that temperatures within enclosed areas do not exceed the device’s maximum rated temperature.
Installing Wall-Mount (MXD) Panels NOTE: When installing the Backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the Backbox may be diff icult without having access to the back of the wall or causing damage to the wall. MXD-2000XL-PAN Dimensions FIG.
Installing Wall-Mount (MXD) Panels MXD-1900L-PAN Dimensions FIG. 26 provides dimensions for the MXD-1900L-PAN: Notes: Dimensions in parenthesis are in millimeters Additional detailed installation and product drawings are available to view/download at www.amx.com FIG. 26 MXD-1900L-PAN - Dimensions NOTE: In order to ensure a stable installation, the thickness of the wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches (2.22cm).
Installing Wall-Mount (MXD) Panels Installing the Backbox MXD-2000XL-PAN Installation Dimensions FIG. 27 and FIG. 28 provide installation dimensions for the MXD-2000XL-PAN: FIG. 27 MXD-2000XL-PAN-L Installation Dimensions (front view) Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Installing Wall-Mount (MXD) Panels MXD-1900L-PAN Installation Dimensions FIG. 29 and FIG. 30 provide installation dimensions for the MXD-1900L-PAN: FIG. 29 MXD-1900L-PAN-L Installation Dimensions (front view) Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Installing Wall-Mount (MXD) Panels Cables Routed to Wall Opening Wall 4X Installation Clamp for Wall Thickness .37 [12.01] to .98 [25.0] 8X Knock Outs Remove For Cable Routing As Needed Mounting screws placement (optional) Note: Additional detailed installation and product drawings are available to view/download at www.amx.com FIG. 31 MXD-1900L-PAN Backbox installation (Landscape) 4.
Installing Wall-Mount (MXD) Panels 13.5V Power Port Ethernet 10/100 Port Type A USB Port (limited access) FIG. 32 MXD-2000XL-PAN / MXD-1900L-PAN - rear connectors NOTE: Refer to the Power via 13.5V section on page 50 for details on wiring a power connection. 8. Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify that the panel is receiving power and functioning properly to prevent repetition of the installation.
Installing Wall-Mount (MXD) Panels NOTE: When installing the panel, do NOT press on or near the center of the panel. Too much stress at the center may damage the touch screen surface. When installing the panel, pressure should be applied toward the ends of the panel ONLY. 10. Use the six provided screws, three at each end, to secure the touch panel to the Backbox. Use only the provided screws, as other screws may damage the touch panel. 11. Snap the decorative side covers onto each end of the panel. 12.
Installing Wall-Mount (MXD) Panels NOTE: Always pull on the frame of the touch panel. NEVER pull on the glass edge. 6. When the first side is free, repeat the process with the other. 7. With the edge of the touch panel free, carefully lift up and out (Landscape) or to the left and out (Portrait) to remove the touch panel from the Backbox. Be careful not to pull on the cables or connectors. 8. To reattach the panel to its Backbox, repeat the installation procedure.
Installing Wall-Mount (MXD) Panels NOTE: When installing the Backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the Backbox may be diff icult without having access to the back of the wall or causing damage to the wall. MXD-1000 Dimensions FIG.
Installing Wall-Mount (MXD) Panels MXD-700 Dimensions FIG. 38 provides dimensions for the MXD-700: Notes: Dimensions in parenthesis are in millimeters Additional detailed installation and product drawings are available to view/download at www.amx.com FIG. 39 MXD-700 - Dimensions NOTE: In order to ensure a stable installation, the thickness of the wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches (2.22cm). The mounting surface should also be smooth and flat.
Installing Wall-Mount (MXD) Panels Installing the Backbox MXD-1000 Installation Dimensions FIG. 41 and FIG. 42 provide installation dimensions for the MXD-1000: FIG. 40 MXD-1000 Installation Dimensions (front view) Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Installing Wall-Mount (MXD) Panels MXD-700 Installation Dimensions FIG. 42 and FIG. 43 provide installation dimensions for the MXD-700: FIG. 42 MXD-700-L Installation Dimensions (front view) Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation. Additional detailed installation and product drawings (for both Landscape and Portrait versions are available to view/download at www.
Installing Wall-Mount (MXD) Panels Leave enough slack in the wiring to accommodate any re-positioning of the panel. FIG. 44 shows the MXD-1000 Backbox installation: 4X Installation Clamp for Wall Thickness .31 [12.0] to .98 [.25.0] 4X Knock-Outs Remove for Cable Routing as Needed #4 Screws FIG. 44 MXD-1000 Backbox Installation (Landscape) FIG. 45 shows the MXD-700 Backbox installation: 2X Installation Clamp for Wall Thickness .37 [12.03] to .98 [.25.
Installing Wall-Mount (MXD) Panels 5. Push the Backbox into the mounting surface. Insure that the locking tabs lie flush against the Backbox and that the Backbox goes freely into the opening. 6. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug. NOTE: The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM].
Installing Wall-Mount (MXD) Panels Ethernet Cable Installation and Modif ication In tabletop installations where concealing the Ethernet cable is desired, a hole at least 1.00” (2.54 cm) in diameter is required in the surface to allow passage of the female RJ45 connector (FIG. 47). If using a smaller hole is unavoidable, you will need to disconnect the Ethernet cable (ECA5968-05) from the device, to feed the male end of the cable through. Ethernet Cable Clamp Connector FIG.
Installing Wall-Mount (MXD) Panels 2. On the bottom (Landscape) or right side (Portrait) of the MXD-1000, locate the seventh and eight ventilation holes from each edge, on the row closest to the Backbox (FIG. 49):. Panel (surface) Access holes #7, #8 Access holes #8, #7 FIG. 49 Bottom View (Landscape) or Right-Side View (Portrait) of the MXD-1000 showing access holes in molding 3. With a stout, strong point (i.e.
Installing Wall-Mount (MXD) Panels Panel (surface) Access hole #5 Access hole #5 FIG. 51 Bottom View (Landscape) or Right-Side View (Portrait) of the MXD-700 showing access holes in molding 3. With a stout, strong point (a push pin or straightened paper-clip, for example), carefully press into the access holes in either end of the molding until the snap is disconnected.
Installing Wall-Mount (MXD) Panels NOTE: When installing the backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the backbox may be diff icult without having access to the back of the wall or causing damage to the wall. FIG.
Installing Wall-Mount (MXD) Panels Installing the Backbox FIG. 54 provides installation dimensions for the MXD-430: Notes: Dimensions in parenthesis are in millimeters Additional detailed installation and product drawings are available to view/download at www.amx.com FIG. 54 MXD-430 - Installation Dimensions (front view) Use the MXD-430 Installation Template (68-5968-05) to ensure proper placement. NOTE: Using the included template to select the f inal placement of the Backbox is highly recommended.
Installing Wall-Mount (MXD) Panels FIG. 55 MXD-430 Backbox Installation - Solid Surface FIG. 56 provides an illustration of the MXD-430 mounting into a drywall surface: FIG. 56 MXD-430 Backbox Installation - Drywall Surface Leave enough slack in the wiring to accommodate any re-positioning of the panel. 4. Remove the knockout on the bottom of the Backbox (FIG. 54) and thread the incoming wiring through the knockout hole. 5. Push the Backbox into the mounting surface.
Installing Wall-Mount (MXD) Panels 6. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug. NOTE: The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM]. Applying excessive torque while tightening the tab screws, such as with powered screwdrivers, can strip out the locking tabs or damage the Backbox.
Installing Wall-Mount (MXD) Panels Snap Backbox Mounting Surface Latch Hooks FIG. 58 Installing the MXD-430 NOTE: If you see a gap between the panel and the Backbox or feel any binding while locking down the panel, stop immediately and verify that no cables or other items are in the way. Do not force the panel into position, as this can cause damage to the touch screen or the panel electronics. 10.
Installing Wall-Mount (MXD) Panels Molding FIG. 59 MXD-430 Molding (highlighted in blue) 2. On the top of the MXD-430, locate the seventh ventilation holes from each edge, on the row closest to the glass (FIG. 60):. Access hole Access hole #7 #7 Panel (surface) FIG. 60 Top View of the MXD-430 showing access holes in molding 3. With a stout, strong point (a push pin or straightened paper-clip, for example), carefully press straight into the access holes in the center of the molding (FIG.
Upgrading Firmware Upgrading Firmware Overview Programming X Series G4 touch panels require the use of NetLinx Studio and TPDesign4, both available from www.amx.com. Downloading Firmware Updates From www.amx.com Before attempting to upgrade the firmware, you must have the appropriate Kit file for your touch panel: NOTE: All X Series touch panels share the same f irmware. 1. Open the product page for the panel, at www.amx.com (Trade Site). 2.
Upgrading Firmware Directory Names for Firmware Files - by Touch Panel Type "MXT-1000" MXT-1000 (FG5968-03) MXT-1000-NC (FG5968-24) "MXD-1000" MXD-1000-P (FG5968-07) MXD-1000-L (FG5968-13) MXD-1000-P-NC (FG5968-25) MXD-1000-L-NC (FG5968-26) "MXT-700" MXT-700 (FG5968-04) MXT-700-NC (FG5968-27) "MXD-700" MXD-700-P (FG5968-08) MXD-700-L (FG5968-14) MXD-700-P-NC (FG5968-28) MXD-700-L-NC (FG5968-29) "MXD-430" MXD-430-P (FG5968-15) 3. Copy the firmware (.
Upgrading Firmware FIG. 64 Previous Firmware installation confirmation dialog 6. If you choose Yes, the device will retrieve the files and then reboot. Returning to Factory Default Firmware X Series panels allow the option to return the device to its original factory default firmware, which may be necessary in certain situations. To return the device to its factory default firmware: 1. From the Settings page, select the Conf iguration page. 2. From the Conf iguration page, select Admin. 3.
Upgrading Firmware FIG. 66 NetLinx Studio - Send to NetLinx Device dialog NOTE: If for any reason your Kit f ile transfer should fail, continue to retry the transfer until you are successful. DO NOT reboot the Master, or change connections until the transfer is complete. Failure to complete this operation successfully may result in a factory repair of the Master.
Troubleshooting Troubleshooting Overview This section describes the solutions to possible hardware/firmware issues that could arise during the common operation of a Modero X touch panel. Panel Doesn’t Respond To Touches Symptom: The device either does not respond to touches on the touch screen or does not register the touch as being in the correct area of the screen. If the screen is off: The device may be in Display Sleep Mode. Press and hold the Sleep button to wake up the panel.
© 2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective companies. AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.