User's Manual

QUICK START GUIDE
HPA-MYT-TX/RX MyTurn
TM
Source Selector
Overview
The HPA-MYT-TX MyTurn™ Source Selector Button (FG554-21) connects to the end of
a standalone MyTurn-Ready cable (HDMI, Mini-DP, DP, RGB, USB), or one thats installed
in a Retractable Cable Module (RCM). A user presses the button to send their device
content to a conference room display. When pressed, the button wirelessly transmits a
signal to the HPA-MYT-RX MyTurn Source Selector Wireless Receiver (FG554-23) that is
wired to an AMX master controller or an AMX switching device, such as a Solecis SDX or
Enova DVX. When used with a Solecis SDX, simple switching can be implemented with
no NetLinx programming required. Each MyTurn Source Selector Receiver can
accommodate up to 8 MyTurn Source Selector Buttons.
MyTurn Source Selector Buttons and Receivers have the following user features:
MyTurn Source Selector Button
Push button – activates input at switcher to display device content
MyTurn Receiver
Select Button – press momentarily to switch ports (indicated by LEDs)
– press and hold to enter “pairing” mode
– press and hold during power up to reset to factory defaults
Product Specifications .
MyTurn Source Selector Solution in a Conference Room
The eight outputs on the rear of the MyTurn Source Selector Receiver connect using
Phoenix connector to the SW inputs on Solecis SDX-510M-DX, or GPIO inputs on NI
Controllers or Enova DVX devices. When the MyTurn Source Selector Button paired with
that I/O port is triggered, the MyTurn Source Selector Receiver activates the AMX
device “SW” input or I/O port, signaling the system to switch the display to that port.
Following are examples of two typical MyTurn Source Selector installations.
Solecis SDX-410/510/810 Switchers
The MyTurn Source Selector Receiver connects to the AMX Solecis front AXLINK port
for power and ground as outlined in FIG. 3. Output ports (1 through 8) are wired to the
corresponding Solecis rear “SW” input that has a MyTurn Source Selector Button
equipped cable connected to it. This solution can be implemented without NetLinx
programming since the SW port is directly connected to the Receiver.
Note: Only on the 5x1 TX, set dipswitch #4 in the ON position (Direct Mode). This will set
the external button behavior to be in direct mode by default. Once the dipswitch is
turned ON the 5x1 TX must be rebooted in order for the setting to take effect.
Enova DVX Master/NetLinx Integrated Controller
The MyTurn Source Selector Receiver connects to an AMX DVX Master or a NetLinx
Controller using the GPIO interface as outlined in FIG. 4. The GPIO port can deliver
Power and Ground as well as receive switch inputs 1-8.
This solution requires NetLinx programming to correlate a GPIO input button event to
switch to a predetermined port on the DVX.
FIG. 1
HPA-MYT-TX MYTURN BUTTON (LEFT) AND HPX-MYT-RX MYTURN RECEIVER (RIGHT)
HPA-MYT-TX SPECIF ICATIONS
Dimensions 1.421” x .645” x 0.40” HWD (36mm x 16mm x 10mm)
Power: Integrated 3VDC coin-cell battery (not replaceable)
Environment Operating Temperature: 32° F (0° C) to 122° F (50° C)
Operating Humidity: 20% to 85% RH
Top Panel: Push-button
Compatibility: Flat Cable Assemblies:
FG10-2192-xx - HDMI 4K60 MyTurn-Ready Flat Cable (xx=16 or 32 ft)
FG10-2193-16 - DisplayPort 4K60 MyTurn-Ready Flat Cable
FG10-2195-16 - RGB with Auto MyTurn-Ready Flat Cable
FG10-2196-16 - Mini DisplayPort 4K60 MyTurn-Ready Flat Cable
FG10-2197-16 - USB MyTurn-Ready Flat Cable
Retractable Cable Module (RCM) Assemblies:
FG552-32 - HDMI 4K60 RCM with MyTurn-Ready Cable
FG552-33 - DisplayPort 4K60 RCM with MyTurn-Ready Cable
FG552-36 - Mini DisplayPort 4K60 RCM with MyTurn-Ready Cable
FG552-35 - RGB with Stereo RCM with MyTurn-Ready Cable
FG552-37 - USB 3.0 RCM with MyTurn-Ready Cable
Accessories: HPX-2BTN-8ACC - 8 button inserts and 8 cable bands kit (optional)
Installation Guide Included
HPA-MYT-RX SPECIFICATIONS
Dimensions (HWD) 3.21” x 2.54” x 0.55” HWD (82.55mm x 69.85mm x 15.24mm)
Enclosure: Polycarbonate plastic with matte finish
Input Voltage: 8-15 VDC on the “+12V” input operates LEDs and I/O outputs
to Solecis, NI-Controller or DVX Switcher
Environment Operating Temperature: 0° C (32° F) to 50° C (122° F)
Operating Humidity: 20% to 85% RH
Front Panel: 8 Yellow LEDs
1 Push button for pairing or port selection
Rear Panel: 1 x 6 Phoenix screw-terminal - I/O 1-4 and Power/Ground
1 x 4 Phoenix screw-terminal - I/O 5-8
1 Green LED indicates power is applied, and flickers when any
wireless transmission is detected.
Accessories: Quick Start Guide Included
MyTurn TX Button
Pairing and port
select button
MyTurn Receiver
FIG. 2 MYTURN TO AMX SOLECIS DIGITAL SWITCHER CONNECTION EXAMPLE
FIG. 3 MYTURN SOURCE SELECTOR SW CONNECTION (1 CONNECTION SHOWN)
FIG. 4 MYTURN SOURCE SELECTOR DVX GPIO TERMINATIONS (5 CONNECTIONS SHOWN)
MyTurn-Ready Cables
in a HydraPort RCM
HydraPort
Chassis
Solecis SDX
MyTurn Button
HDMI
mDP
DP
MyTurn-Ready
HDMI Cable
Power LED
MyTurn-Ready HDMI Cable
Source End
Solecis SDX-Front
Solecis SDX-Rear
HPX-MYT-RX Receiver
HPX-MYT-TX
Button
Display End
HDMI Cable with
HPA-MYT-TX
MyTurn Button
DVX Master
HPA-MYT-RX MyTurn Receiver