essen Blood Pressure Monitor P/N 921-106930E Rev 1 0111 Instruction Manual Model: 106-930 Physio logic essentia Manual (ENG) 106-930 921-106930E 21.5 cm x 14.5 cm 21.5 x 14.5 cm (folded: 10.75 x 14.
Contents IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • White Coat Syndrome ABOUT BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 • Blood Pressure Standard • Blood Pressure Fluctuation YOUR BP MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 • LCD Layout • Unit Layout POWER OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 SETTING TIME, DATE & UNITS OF MEASUREMENT . . . . . . . . 9 MEASUREMENT. . . .
IMPORTANT INFORMATION ATTENTION • This Blood Pressure Monitor does not replace examination by a physician. As your doctor is the one person best qualified to interpret your results, we recommend that you keep a blood pressure journal to bring to your visits to your healthcare professional. • This device is intended for adult use only. • This device is intended for non-invasive measuring and monitoring of arterial blood pressure.
ABOUT BLOOD PRESSURE MEASUREMENT TIPS What are systolic and diastolic pressure? When ventricles contract and pump blood out of the heart, blood pressure reaches its maximum value. The highest pressure in the cycle is known as systolic pressure. When the heart relaxes between heartbeats, the lowest blood pressure is diastolic pressure.
YOUR BP MONITIOR YOUR BP MONITIOR LCD layout MEMORY ZONE 1 2 3 4 LOW BATTERY INDICATOR CUFF IS INFLATING DATE LCD SCREEN SYSTOLIC BLOOD PRESSURE POWER BUTTON mmHg kPa CUFF IS DEFLATING TIME 888 888 Your Monitor 18 88 18 88 M AM PM D 188 DIASTOLIC BLOOD PRESSURE ON/OFF PULSE RATE No AIR JACK MEMORY NUMBER INDICATOR SET BUTTON (+) BUTTON Arm Cuff ARM CUFF 6 (–) BUTTON AIR TUBE AIR PLUG BATTERY COVER 7 AC ADAPTOR SOCKET Physio logic essentia Manual (ENG) 106-930 921-106930E 21
POWER OPTIONS 1. Battery: 4 x AA alkaline 2. Power Adapter: A 6V 1000mA AC adapter can be used with this device (not included) Adapter socket pictured at right BEFORE YOU START Selecting memory zone and setting date, time & unit of measurement ON/OFF CAUTION It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each reading that is stored in the memory. Do not use any other type of battery or adapter as it may harm the unit.
BEFORE YOU START 3. After selecting the right memory zone, press SET to automatically move on to the next step. MEASUREMENT Prepare the cuff 1 1. Firmly insert air plug into opening located on left side of the monitor. SET ON/OFF ON/OFF 4. Repeat steps 2 and 3 to set the MONTH, DAY, HOUR and MINUTE. 1 10 38 6 18 M AM D SET 5. After the unit is set, press the power button to turn off the unit and save all current settings. ON/OFF ON/OFF 2. Wrap the cuff around your upper left arm.
MEASUREMENT 3. The cuff should be snug but not too tight. (You should be able to insert one finger between the cuff and your arm). Keep a space of ± 1” between the cuff edge and the bend of your elbow. MEASUREMENT Start the measurement ~1” (2~3cm) 1 1. Press and hold the ON/OFF button until a beep sounds. The LCD screen will light up for one second as the unit performs a quick diagnosis. A long tone indicates the device is ready for testing. Levels: ON/OFF 888 888 mmHg kPa 18 88 18 88 M 2.
MEASUREMENT 3. Once inflated, the cuff will slowly deflate and measure your blood pressure. A flashing “ “ will appear simultaneously on screen signaling heart beat detection. MEASUREMENT 98 1 mmHg 10 38 6 18 M 4. When testing is complete the monitor will sound three short beeps. The screen will display your systolic and diastolic blood pressure. The reading will be automatically stored in the selected memory zone. 5. To measure again, press ON/OFF to return to testing mode.
USING THE MEMORY USING THE MEMORY To recall previous readings To delete all records from memory 1. With the power off, you may check past readings by using the “+” or “-” buttons. The most recent reading can be viewed by pressing and holding the “+” button. The oldest reading in memory can be viewed by pressing and holding the “-” button. You can clear the memory for the selected group by following the steps listed below. SET ON/OFF 1. Press and hold the “+” button for 3 seconds. SET ON/OFF 2.
TIPS FOR TAKING ACCURATE READINGS MAINTENANCE How to clean and care for your blood pressure monitor. ON/OFF Wait at least 1 hour after eating or drinking before taking a measurement. Avoid taking readings immediately after having tea, coffee or smoking. Store in a dry place and avoid exposing to direct sunshine. Avoid contact with water, wipe away any moisture with a dry cloth. ON/OFF ON/OFF Wait at least 20 minutes after taking a bath before taking a measurement.
TROUBLESHOOTING TROUBLESHOOTING The table below indicates how to solve common problems that you may encounter when using this monitor. If the product is not operating as you think it should, please check here first before calling customer service.
WARRANTY SPECIFICATIONS Power 4 AA batteries / DC 6V 1000mA 2 year limited warranty Display Digital LCD 84.1mm x 55.1mm AMG Medical Inc. warrants this product to be free from defects in material and workmanship for a period of two (2) years. This warranty is valid for the original purchaser only. Any alterations, abuse, misuse or accidental damage voids this warranty.
CONTACT INFORMATION For any question concerning this product, please call: 1-800-363-2381 www.amgphysiologic.com 24 Physio logic essentia Manual (ENG) 106-930 921-106930E 21.5 cm x 14.5 cm 21.5 x 14.5 cm (folded: 10.75 x 14.