Ultima™ Manual Flush Valve Installation Instructions Diaphragm-Type Toilet MODEL NUMBERS 6147 Series 6145 Series Urinal OPERATING PRESSURE: 25 psi (flowing)-80 psi (static) OPERATING PRESSURE: 20 psi (flowing)-80 psi (static) FLOW REQUIREMENT: 25 gpm (94.6 L/min.) FLOW REQUIREMENT: 10 gpm (37.9 L/min.) Certified to comply with: • ASSE 1037 • ANSI/ASME A112.19.2 • ADA Compliant NOTE TO INSTALLER: Please give this manual to the customer after installation.
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping 1. R emove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton.
Roughing-in Dimensions Fig.1 SUPPLY DN 25 mm (1" I.P.S.) 38mm-127mm (1-1/2-5") -C-L- *CRITICAL LEVEL 6047.122 735 mm (29") 6047.117 ROUGH-IN DIMENSION 610 mm (24") 152 mm (6 " ) (Min.) FINISHED WALL 38mm-127mm (1-1/2-5") (4-1/4" to 5-1/4") 6047.117 660 mm (26") 6047.122 ROUGH-IN DIMENSION 686 mm (27") 6047.121 ROUGH-IN DIMENSION 292 mm (11-1/2") 108-133 mm (4-1/4" to 5-1/4") Roughing-in Dimensions Fig.2 108mm-133mm FINISHED WALL SUPPLY DN 19mm (3/4" I.P.S.
1 INSTALL SWEAT SOLDER ADAPTER; Fig. 3 CAUTION Fig.3 Fig.3a FINISHED WALL Turn off hot and cold water supplies before beginning. A Note: Install Optional Sweat Solder Adapter (Supplied) for copper pipe supply line. Fig. 3. (A-B)= C 1. Measure the distance (A) from the finished wall to the center of the inlet spud on the fixture. 2. Cut the supply pipe 1-1/4" (A-B=C) shorter then the measurement taken in Step 1. File any rough edges off the end of the supply pipe. 3.
4 INSTALL FLUSH VALVE; Fig. 6a & 6b Fig. 6a 3 1. As shown in Fig. 6a, insert the TAILPIECE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 6a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape 2. Align the FLUSH VALVE (2) (Fig. 6b) directly above the VACUUM BREAKER (7) and VACUUM BREAKER COUPLING NUT (6).
SUPPLY STOP; Fig. 13 6 ADJUST Fig. 13 REMOVE COVER IMPORTANT: To avoid overflowing, the SUPPLY STOP (3) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. Valve is designed to provide stated flush volume with a 25 gpm flow rate for toilet and 10 gpm flow rate for urinal. 3 2 COUNTER-CLOCKWISE OPENS CONTROL STOP 1. Remove COVER (2) from SUPPLY STOP (3).Turn on water supply 1/4 turn to 1/2 turn(CCW) and test for leaks.
DIAPHRAGM FLUSH VALVE Toilet with Manual Operation MODEL NUMBER 6147 Series M909318-0070A INSIDE COVER M954323-0070A DIAPHRAGM ASSEMBLY 1.1 GPF M954322-0070A DIAPHRAGM ASSEMBLY 1.28 GPF M954319-0070A DIAPHRAGM ASSEMBLY 1.0/1.
Ultima™ Manual Flush Valve Diaphragm-Type MODEL NUMBER 6145 Series M909318-0070A INSIDE COVER M954327-0070A DIAPHRAGM ASSEMBLY 0.125 GPF M954326-0070A DIAPHRAGM ASSEMBLY 0.5 GPF M954319-0070A DIAPHRAGM ASSEMBLY 1.0/1.
Installation Instructions Ultima™ Sensor-Operated Flush Valve MODEL NUMBERS 6145SM 6147SM With Side-Mount Operator, Diaphragm-Type Toilet Urinal OPERATING PRESSURE: 25 psi (flowing)-80 psi (static) OPERATING PRESSURE: 20 psi (flowing)-80 psi (static) FLOW REQUIREMENT: 25 gpm (94.6 L/min.) FLOW REQUIREMENT: 10 gpm (37.9 L/min.) Certified to comply with: • ASSE 1037 • ANSI/ASME A112.19.2 • ADA Compliant NOTE TO INSTALLER: Please give this manual to the customer after installation.
Thank you for selecting American Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping 1. R emove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton.
Roughing-in Dimensions Fig.1 147 mm (5-13/16") 108 mm-133 mm (4-1/4" to 5-1/4") -C-L- *CRITICAL LEVEL 253 mm (9-15/16") SUPPLY DN 19 mm (1" I.P.S. For 1" Top Spud) Fig.2 38 mm-127 mm (1-1/2-5") 6047.1x2 ROUGH-IN DIMENSION 686 mm (27") 6047.1x1 ROUGH-IN DIMENSION 292 mm (11-1/2") 147 mm (5-13/16") 108 mm-133 mm (4-1/4" to 5-1/4") FINISHED WALL SUPPLY DN 19 mm (3/4" I.P.S. For 3/4" Top Spud) 38 mm-127 mm (1-1/2-5") 6047.117 739 mm (29-1/8") -C-L- -C-L- 6047.1x2 765 mm (30-1/8") 6047.
FLUSH VALVE INSTALLATION Fig. 3 FINISHED WALL 1 INSTALL SWEAT ADAPTER; Fig. 3 CAUTION A Turn water supplies off before beginning (A-B)= C Note: Install Optional Sweat Adapter (Supplied) for copper pipe supply line. CENTER LINE OF FIXTURE SPUD B 32mm (1-1/4") FILE EDGES 1. Measure the distance (A) from the finished wall to the center of the inlet spud on the fixture. 2. Cut the supply pipe 1-1/4" (A-B=C) shorter than the measurement taken in Step 1.
4 INSTALL FLUSH VALVE; Fig. 6a & 6b Fig. 6a 3 1. As shown in Fig. 6a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 6a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 2. Align the FLUSH VALVE (2) (Fig. 6b) directly above the VERTICAL TUBE (7) and VACUUM BREAKER COUPLING NUT (6).
6 ACTIVATION; Fig. 8 Fig. 8 5 Note: Four (4) “C” Cell batteries are not factory installed inside the Flush unit. 1. Remove BATTERY TRAY (1) by loosening SCREW (3). 2. Load 4 “C” Alkaline BATTERIES (5) onto BATTERY TRAY (1). 3. Install battery tray into SIDE MOUNT OPERATOR (2) and tighten SCREW (3) using WRENCH (4) provided. (Note: last three turns of the wrench will activate the automatic flushing unit) 3 4 + + + 2 5 Fig. 9 1. Remove BATTERY TRAY (1) by loosening SCREW (3). Fig. 9 2.
11 ADJUST SUPPLY STOP; Fig. 13 Fig. 13 REMOVE COVER IMPORTANT: To avoid overflowing, the SUPPLY STOP (3) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. Valve is designed to provide stated flush volume with a 25 gpm flow rate for toilet and 10 gpm flow rate for urinal. 3 2 COUNTER-CLOCKWISE OPENS CONTROL STOP 1. R emove COVER (2) from SUPPLY STOP (3).Turn on water supply 1/4 turn to 1/2 turn(CCW) and test for leaks.
DIAPHRAGM FLUSH VALVE Urinal Flushometer with Side-Mount Operator MODEL NUMBERS 6145SM M909318-0070A INSIDE COVER M954327-0070A DIAPHRAGM ASSEMBLY - 0.125 GPF M954326-0070A DIAPHRAGM ASSEMBLY - 0.5 GPF M954319-0070A DIAPHRAGM ASSEMBLY - 1.0/1.6 GPF A912809-0070A TAILPIECE O-RING SMGODIA.
Ultima™ Sensor-Operated Flush Valve With Side-Mount Operator, Diaphragm-Type MODEL NUMBERS M909318-0070A INSIDE COVER 6147SM M954323-0070A DIAPHRAGM ASSEMBLY 1.1 GPF M954322-0070A DIAPHRAGM ASSEMBLY 1.28 GPF M954319-0070A DIAPHRAGM ASSEMBLY 1.0/1.6 GPF A912809-0070A TAILPIECE O-RING SMGODIA.