WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL MODEL NUMBERS: 3052OD.X0X SSXOD5230 C3052OD.X0X SSXOD5230C 3052D.XXX SSXOD5232 C3052D.XXX SSXOD5232C 3252OD.X0X ST5230D C3252OD.X0X ST5232DC THANK YOU... for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The combination tub version is completely assembled with pump, motor, and system piping.
CONGRATULATIONS! You are now the owner of a walk-in bathtub from the most trusted name in plumbing. We thank you for your purchase. Your American Standard® walk-in bath is a true investment in your health and peace of mind. Customer Support: (866) 423-0800 754818-100 Rev.
OWNER’S MANUAL TABLE OF CONTENTS: UNPACKING THE UNIT ...................................................................................... Page 4 RESPONSIBILITIES OF THE INSTALLER ......................................................... Page 5 TESTING YOUR TUB BEFORE INSTALLATION................................................. Page 6 INSTALLATION PREPARATION .......................................................................... Page 7 ELECTRICAL INSTALLATION..........................................
OWNER’S MANUAL UNPACKING THE UNIT 1. FIRST, inspect the carton for damage: CAREFULLY DOCUMENT AND PHOTOGRAGH ALL PERCEIVED DAMAGE. Report all damage claims to customer service at 1-866-423-0800. 2. DO NOT LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks, for which the installer is responsible. All Walk-In Tubs are water tested before they leave our factory and the bathtub you have purchased has passed inspection. 3. Immediately inspect the unit for damage even if there is no carton damage.
OWNER’S MANUAL RESPONSIBILITIES OF THE INSTALLER The Installer must inspect and water test the product prior to installation to ensure the unit is free of defect and /or damage. In the event of a problem, the unit must not be installed. If the packaging or product has been damaged, please call immediately at 1-866-423-0800. This product has been listed by INTERTEK / ETL and IAPMO / C UPC.
OWNER’S MANUAL TESTING YOUR WALK-IN TUB BEFORE INSTALLATION 1. All American Standard® walk-in baths are 100% water tested at the factory and have passed inspection. Transportation and mishandling may loosen fittings and cause leaks. It is therefore necessary to test the bathtub while there is access to all sides of the bath. 2. The unit needs to be filled with water and inspected for leaks along the door as well as the whirlpool and air systems if equipped.
OWNER’S MANUAL INSTALLATION PREPARATION 1. Check the floor area where the tub is to be installed. a. Clean area of any debris or trash. b. Use a 5 or 6-foot level and determine if the floor is level. If the floor is not level, adjust all leveling feet to perfectly level the tub. Note: It is important that all leveling feet are completely touching the floor and level for the door system to work properly. Leveling Feet 2. Check to ensure that the drain piping has been “roughed-in” at the proper location.
OWNER’S MANUAL ELECTRICAL INSTALLATION All electrical wiring must be installed in accordance with the National Electrical Code and with all local codes. All wiring shall be done by a qualified electrician. Run one, two or three branch circuits (as required) from the main electrical service panel to the pump area of the framing structure to provide power to the unit. Electrical components have specific wiring requirements.
OWNER’S MANUAL INSTALLATION PROCEDURES ! WARNING: When installing whirlpool massage baths, air spa baths, combo baths, or Quick Drain® equipped baths, the following precautions must be followed: ! WARNING: Danger: Risk of electrical shock; connect components to separate circuits, EACH protected by a ground fault circuit interrupter (GFCI) ! WARNING: Installation must provide access for servicing the pump and motor (all American Standard® walk-in baths come with access panels for the pump, motor and fa
OWNER’S MANUAL INSTALLATION PROCEDURES (continued) WARNING: Never allow the weight of the tub to be supported by wood support stringers and do not use integral tile flange (if equipped) to screw or nail in place, as this will result in product failure and will void the warranty. 6. Verify the product is completely level by checking tub deck surface and ensure all leveling feet are touching the ground. 7. Electrical connection is made by simply plugging each cord into the GFCI outlet. 8.
OWNER’S MANUAL ALCOVE INSTALLATION 52" (1321mm) 13" (330mm) DRY WALL WALL STUD GALVANIZED NAIL 16-1/2" (419mm) TILE SILICONE TILE FLANGE TUB 30" (762mm) NON-INTEGRAL FLANGE 40" (1016mm) ROUGH FLOOR Tubs installed in an alcove installation require a raised flange to prevent water from seeping past the tub and into the wall. Tubs without a raised flange shall be installed with a tile flange kit such as model: 9FLNG or a similar type.
OWNER’S MANUAL OUTWARD OPENING DOOR MODELS SERIES: 3252 SERIES: 3052 754818-100 Rev.
OWNER’S MANUAL ACRYLIC EXTENSION KIT INSTALLATION The Acrylic Extension Kit is designed to accommodate all acrylic walk-in tubs to fit within a 60" alcove pocket. The top panel measures 30" x 20" (depth x width) and the front panel 37-1/2" x 20" (height x width). The panels must be trim to fit the unit within the 60” alcove. Step 1 • Temporary locate the tub within the alcove walls. • Level the tub along the deck and apron.
OWNER’S MANUAL ACRYLIC EXTENSION KIT INSTALLATION Step 5 & 6 • Remove the tub from the alcove and install the front and then top panel with the self tapping fasteners. Predrill screw holes and attach front panel to apron Predrill screw holes and attach top deck of tub Self tapping screw Self tapping screw Step 7 & 8 • Apply the temporary clamps to help support the front and top panels while re-locating the tub back into the alcove.
OWNER’S MANUAL DRAIN OVERFLOW INSTALLATION DRAIN / OVERFLOW INFORMATION A drain / overflow assembly is provided with the tub must be installed on the bath, water tested and connected to the sanitary system of the house. Some drain / overflow kits are packed with the waste flange, strainer, overflow cover, and fasteners, packed separately within the kit to protect the trim finish. Follow the installation instructions provided with the drain / overflow kit.
OWNER’S MANUAL THRESHOLD DRAIN INSTALLATION THRESHOLD DRAIN INFORMATION All gel coat walk-in bathtubs are provided with a threshold door drain. All acrylic walk-in bathtubs feature the “Patented T5 Door System” which does not require the threshold drain. CONNECTION OF THE DOOR DRAIN • Door Drain requires the connection to a minimum 1-1/2" sanitary drain line. • Use UPC Approved PVC Glue, Primer, and Schedule 40 1-1/2" pipe.
OWNER’S MANUAL INLINE HEATER INSTALLATION WHIRLPOOL IN-LINE HEATER All whirlpool systems are deigned with an In-Line Heater Blank. The threads and union set on the heater blank and heaters are specifically designed for our system. All other heaters and heater blanks will not interchanges with our system. The heaters are equipped with a preset pressure switch which will not allow the heater to turn on if the pump is not running with water flowing through the whirlpool system.
OWNER’S MANUAL IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. ! WARNING: Risk of personal injutry. Use this unit for its intended use as described in this manual. DO NOT use attachments not recommended by the manufacturer. ! WARNING: Risk of personal injutry. To avoid injury, exercise caution when entering or exiting your walk-in bath. ! WARNING: Risk of personal injutry.
OWNER’S MANUAL SAVE THESE INSTRUCTIONS! OPERATING INSTRUCTIONS 1. Enter your American Standard® walk-in bath, close the door, place handle in down position, and fill the bath to at least 2 inches above the highest jet before activating the whirlpool pump (if equipped). Do not apply excessive pressure when placing the handle in the close position. Do not put weight on the door when entering and exiting the tub. It is recommended to leave the door in the open position when the tub is not in use. 2.
OWNER’S MANUAL SAVE THESE INSTRUCTIONS! OPERATING INSTRUCTIONS (continued) 9. If your American Standard® walk-in bath is equipped with Chromatherapy lights, the lights have a dedicated control button. Pressing the control button off and back on will change the color of light. 10. If any factory-installed fittings have been removed, do not operate the unit. A safety hazard may have been created by this modification. Seek the help of a qualified professional. 11.
OWNER’S MANUAL CLEANING AND MAINTENANCE Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. Below are the recommended procedures for cleaning: • Do not run whirlpool dry. Fill the tub with hot water 2-3 inches above the jets and add 2-3 teaspoons of low foaming detergent such as dishwashing machine detergent. • Turn on whirlpool system and run for 10 minutes. • Drain tub completely. • Fill tub with cold water above jets.
OWNER’S MANUAL LIMITED WARRANTY COVERAGE American Standard® Walk-In Baths are warranted in accordance with the following warranty: This warranty is extended to the first purchaser and does not extend to products previously used as display models or products that have been modified or repaired by anyone else but American Standard unless approved by American Standard.
OWNER’S MANUAL TROUBLE SHOOTING GUIDELINES WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. To reduce the risk of injury, keep all components in a vented enclosure and out of the reach of children. ! Risk of Electrical Shock – Connect only to a grounding type receptacle protected by a ground fault circuit interrupter (GFCI). ! Verify all components are installed to dedicated circuit(s) with the recommended electrical rating.
OWNER’S MANUAL TROUBLE SHOOTING GUIDELINES (continued) WHIRLPOOL PUMP MOTOR WILL NOT START – CHECK FOR: • Check the air line between the motor and air button for connection and depress to test air signal. • Improper or loose connections, open switches or relays, blown circuit breakers. • Manually check rotation of motor shaft for free movement and obstruction. MOTORS CUTS OUT – CHECK FOR: • Wiring, loose connections etc. • Low Voltage at motor. (Frequently caused by undersized wiring.
OWNER’S MANUAL TROUBLE SHOOTING GUIDELINES (continued) HEATERS All heaters are equipped with a preset pressure switch which will not allow the heater to turn on if the pump is not running with water flowing through the whirlpool system. The heater includes an exclusive High Limit Switch. This safety circuit will not false trip from hot tap water. It will turn off the heater is the thermostat fails.