User's Manual

INSTALLATION INSTRUCTIONS
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped
to you after careful inspection. The whirlpool version is completely
assembled with pump, motor, and system piping. All you need to
finish the installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from this product,
please follow the instructions and cautions.
752878-100 Rev. E
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
SAVONA OVAL™
WHIRLPOOL/BATHING POOL
2903.XXXW SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard,
tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the
safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are
provided by others.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
1524mm
(60)
ROUGH
FLOOR
1-1/2 O.D.
TAILPIECE
OUTLINE OF
CUTOUT - USE
TEMPLATE
241 mm
(9-1/2)
1073mm
(42-1/4)
489mm
(19-1/4)
INTEGRAL
FEET
SUPPORT
95mm
(3-3/4)
51mm
(2)
537mm
(21-1/8)
76mm
(3)
C
L
OF DRAIN
OUTLET
540mm
(21-1/4 )
1-1/2 N.P.T.M.
THREADS
35mm
(1-3/8)
305mm(12) X 229?mm(9)
CUTOUT IN FLOOR FOR DRAIN
98mm
(3-7/8)
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
ON/OFF
SWITCH
PUMP
(MAY
EXTEND
BEYOND
RIM BY 1-1/2")
SEE FTTG.SPECS
FOR DIMENSION
C
L
OF SUPPLIES
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
1651-1981mm
(65-78)
OPTIONAL
102mm
(4)
305mm
(12)
SAFE-T-HEATER
REMOVABLE
BLANK
GENERAL SPECIFICATIONS FOR 2903 WHIRLPOOL
60 x 42-1/4 x 21-1/4 In.(1524 x 1073 x 540mm)
107 Lbs. (49 Kg.)
640 Lbs. (291 Kg.)
64 Gal. (243 L)
53 Gal. (201 L)
45 x 23 In. (1143 x 584mm)
53 x 32 In. (1346 x 813mm)
15 In. (381mm)
35 Lbs./Sq.Ft. (166 Kgs./Sq.m)
27.8
45.4
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.SYSTEM I PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)

Summary of content (4 pages)