EN Parts Description A Eyepiece cover R Power switch B Diopter adjustment S Locking set C Interpupillary distance adjustment T Condenser diaphragm D Head U Condenser vertical adjustment knob E Nose piece V 4x objective lens F Stage clip W 10x objective lens G Stage X 40x objective lens H Condenser Y 100x objective lens I Transmitted light lamp Z 10x eyepiece x2 J Base AA 20x eyepiece x2 K Arm AB Color filter (green) L Coarse adjustment knob AC Dust cover M F
EN IMPORTANT SAFEGUARDS Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included. When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following: WARNING It is prohibited to disassemble the machine.
EN • A separate tin or bucket should be used for the disposal of specimen samples and dyes. Any wasted solution should be poured directly down a drain, but never into a sink basin. • Dispose of used specimen samples a household trash immediately after use. • Do not discard any equipment into the fire to avoid violent combustion or explosion. • If the product has to be moved, carry with one hand holding the product at the arm and another hand supporting it at the base.
EN Symbols Explanation ~ Alternating current (AC). Health advice for emergencies. Wash hands before and after experiments. Safety warning. Improper use of the product could result in injury or death. Intended Use • This product is for private use, home schooling, school applications and teaching demonstrations. It is not for commercial use. • This product is intended to be used in dry indoor areas only.
70 65 75 EN • Remove the cover on the base of the head (D). • Remove the cover on the top of the arm (K). • Connect the two pieces together. • Fasten the head (D) using the screw on the arm (K). E X V 0 10 0 11 0 12 W 0 13 0 14 0 15 0 16 Y 0 17 0 18 0 19 0 10 Attach the objective lenses (V, W, X, Y) in a clockwise sequence according to increasing magnification power onto the nose piece (E).
EN To use the mirror instead of the transmitted light lamp (I): • Attach the mirror (AD) onto the mirror stand (AE) • Unscrew the diffuser of the transmitted light lamp (I) from the base. • Screw the mirror stand (AE) onto the base. NOTICE Using the mirror does not require electrical connection. Operation Switching on/off • Connect the power cord (AF) to a power outlet and the other end to the power socket (P).
EN Observing through the microscope 70 70 65 65 75 75 Z AA 0 10 0 10 0 11 0 11 0 12 0 12 0 13 0 13 0 14 0 14 0 15 0 15 0 16 0 16 F 0 17 0 17 0 18 0 18 0 19 0 19 0 0 10 10 20 20 40 1 60 120 0 180 140 20 180 0 10 20 0 10 G 60 0 60 120 50 50 140 30 30 40 1 60 10 10 L L N O Q • Remove the eyepiece covers (A) and place in eyepieces (Z/AA). • Turn the coarse focus knob (L) to adjust the height of the stage (G) to the lowest position.
EN H AB NOTICE To use the color filter (AB), slide open the base of the condenser (H) and place the color filter (AB) inside. • Look into the left eyepiece (Z/AA), rotate the fine focus knob (M) and the left diopter adjustment (B) slowly until the image is clear. Adjust the position of the slide if needed. CAUTION Risk of damage! Never force the adjustment knobs (M), (L) and, (U) to turn further once the knob is already restrained from turning. It may cause friction and scratch the lenses.
EN • Look into both eyepieces (Z/AA), adjust the distance of the interpupillary distance adjustment (C) until the two images merge into one. NOTICE After focusing, there is an option to push up the locking set (S) to keep the adjustment knobs (L, M) in place. • Rotate the nose piece (E) to the next objective lens, increasing in magnification power. Re-adjust the focus using the fine focus knob (M) if needed.
EN FCC – Supplier’s Declaration of Conformity Unique Identifier B07TWLF9Z2 - Compound Binocular Microscope Responsible Party Amazon.com Services, Inc U.S. Contact Information 410 Terry Ave N. Seattle, WA 98109, United States Telephone Number (206) 266-1000 FCC Compliance Statement 1. This device complies with Part 15 of the FCC rules.
EN Specifications Voltage input: 100-240 V~, 50/60 Hz Fuse rating: T250V 500mA LED lamp S-LED W1 Magnification power range: 40x to 2000x Objective conjugate distance: 7.6" (195 mm) Stage movement range: 2.95 x 1.96" (75 × 50 mm) Coarse focusing range: 1.1" (28 mm) Fine focusing range: 1.1" (28 mm) Fine division step: 0.002 mm Condenser N.A.: Abbe 1.2 Diameter of filter: Ø 1.25" (32 mm) Working temperature: 50 to 104°F (10 to 40°C) R.H. range: 30 to 75% Net weight: approx. 24.