INSTALLATION AND OPERATION INSTRUCTIONS FOR 40-TRU-VIEW-XL 50-TRU-VIEW-XL 60-TRU-VIEW-XL 72-TRU-VIEW-XL SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TABLE OF CONTENTS Please read and carefully follow all of the instruction found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product. IMPORTANT INSTRUCTIONS....................................................................................................................................3 UNPACKING AND TESTING APPLIANCE ...............
IMPORTANT INSTRUCTIONS 1. Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and rear as well. 3. Always unplug heater when it’s not in use. 4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way. 5.
Cautions Do’s Don’ts ·Always install the heater in accordance with this guide. If in doubt obtain expert advice. ·Always make sure the electrical socket is accessible and located adjacent to, but not above the heater. ·Always disconnect the heater from the electrical supply before moving it, or carrying out cleaning, maintenance. ·Always make sure the heater is firmly secured to prevent it from being tipped over.
UNPACKING AND TESTING APPLIANCE Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the power supply cord into a conveniently located 120 Volt grounded outlet. Test all aspects of its operation (manual switches, remote and heater) to make sure all components operate correctly. As with most electronic devices, your new electric fireplace has been designed to operate at temperatures between 5 (41 ) and 35 (95 ).
40-TRU-VIEW-XL Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 43 1/4” or 109.7 cm 26 5/8” or 67.
50-TRU-VIEW-XL Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 53 1/4” or 135.2 cm 26 5/8” or 67.
60-TRU-VIEW-XL Model Number Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Build-in Appliance 120V AC 60Hz 1500W Max 25W 19W 63 1/4” or 160.6 cm 26 5/8” or 67.
72 –TRU-VIEW-XL Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1500W Max 25W 19W 75 1/4” or 191 cm 26 5/8” or 67.
SAFETY DRILL SCREW AREA There is a safety drill screw area as show below. Please make sure that the fix screws are in this area. T h e m a n u a l c o n tro l p a d p o s itio n Sa fe ty d rill s cre w a re a (Da rk a re a ) HARD- WIRE INSTALLATION Turn off the appliance completely and let cool before servicing. Only a qualified service person should service and repair this electric appliance.
2. Attach the wiring to the junction block. Please make sure the live wire goes into the “L”, the neutral wire into “N” and the ground wire into “G”. 3. Put the plate back and screw back. FOR BATHROOM USE If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit. If receptacle is used it must be readily accessible.
OUTDOOR INSTALLATIONS The TRU-VIEW-XL series electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance. See illustration below. All wiring connections to line power shall be in accordance with local building code requirements.
INSTALLATION The TRU-VIEW-XL models are designed to be built-in and allow for the finishing material (drywall, stone, tile, etc) to be built right down to the glass edge. The rough wall opening size of the fireplace: NOTE: Due to the many different materials used on different walls, it is highly recommended that you consult your local builder before you install this appliance.
framing plate framing plate 5. Make an opening for the fireplace according to requested measurement. 7. After checking that the fireplace operates properly, cover the glass panels with protective plastic bag and install plywood or drywall. 6. Insert the fireplace into the wall opening. Drive the mounting screws into the frame plates on the unit and the wall studs.
fending bar and panel. 8. Decorate the plywood or drywall with glazed tile, wallpaper, etc. 3. After the fending panel is removed, screw back the bar. Installation for Front and Right Side Viewing 1. To install the fireplace where the left side is close to a wall, and you want to view the fire from front and right side, take off the fending panel on the right. 4. Remove the framing plates from the fireplace and fix them as the picture shows.
5. Make an opening for the fireplace according to requested measurement. 7. After checking that the fireplace operates properly, cover the glass panels with protective plastic bag and install plywood or drywall. 6. Insert the fireplace into the wall opening. Drive the mounting screws into the frame plates on the unit and the wall studs. To fix the bottom of the fireplace and the wall studs with the framing plates that you’ve removed from left and right side of the fireplace at STEP 4.
Installation for Front and Left Side Viewing 1. Install the fireplace where the right side is close to a wall, and you want to view the fire from front and left side, take off the fending panel on the left. 4. Remove the framing plates from the fireplace and fix them as the picture shows. Note: After removing framing plates on the left and right sides, screw back the screws. 2. Unscrew 7 screws on the right side that fix the fending bar and panel and then take off the fending bar and panel. 5.
7. After checking that the fireplace operates properly, cover the glass panels with protective plastic bag and install plywood or drywall. 6. Insert the fireplace into the wall opening. Drive the mounting screws into the frame plates on the unit and the wall studs. To fix the bottom of the fireplace and the wall studs with the framing plates that you’ve removed from left and right side of the fireplace at STEP 4. Plug in and check if the fireplace works. 8.
Media Options The 40-TRU-VIEW-XL is shipped with 1 set of FI-109-DIAMOND, 50-TRU-VIEW-XL and 60-TRU-VIEW-XL are shipped with 2 sets of FI-109-DIAMOND, 72-TRU-VIEW-XL is shipped with 3 sets of FI-109-DIAMOND. FI-109-DIAMOND 3 glass nuggets, 1 bag of clear, 1 bag of small clear, 1 bag of clear diamond and 1 bag of blue diamond. The TRU-VIEW models also come with the DESIGN-MEDIA-11PCE Kit featuring an 11 pcs deluxe log set, pebbles, stones, black glass and an assortment of vermiculite embers.
Media Operation 1. Unscrew 2 screws and take off two brackets which are fending the front glass panel. Screws and brackets 4. Installing the fire glass media. Pour the fire glass media into the tray as shown below. Feel free to use any combination of fire glass media that you find most appealing. 2. After the brackets are removed, the front glass panel will fall down automatically. 3. Take off the front glass panel and put it in safe place. 5.Put back the front glass and screw back the bracket.
OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. The main power ON/OFF switch in position O, the fireplace is OFF. 2. When main power ON/OFF switch is at position I, the fireplace is ready to use. 3. Press the button repeatedly to set the heater to desired heat setting. The heater indicator LED will glow which shows the current heater settings.
REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and main power switch located on the bottom left hand side is at position I. When operating the remote make sure you point the remote to the centre of the fireplace and make sure each time you press the button. The buzzer inside the unit will beep once. It takes some time for the receiver to respond to the transmitter. Do not PRESS the buttons more than once within two seconds for correct operation.
INSTALLING WALL THERMOSTAT WALL THERMOSTAT WIRING DIAGRAMS Wire the wall thermostat prior to installing the fireplace. WALL THERMOSTAT WIRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2. Remove cover plate located on the left side of appliance. 3. Pull the wire out and cut the inside thermostat. Connect the wires to the wall thermostat as shown below. Follow instructions provided with wall switch kit.
REPLACEMENT PARTS This list contains replacement parts NO 1 PART NUMBER 40-TRU-VIEW-XL 50-TRU-VIEW-XL 60-TRU-VIEW-XL 72-TRU-VIEW-XL 10701281 10701216 10701217 10701218 DESCRIPTION QTY.
EXPLODED VIEW 25
Wiring Diagram 26
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE Dim or no flame Flame LED’s are burnt out Ember bed is not glowing or dimming Appliance turns off and will not turn on Appliance will not come on when switch is flipped to ON SOLUTION Inspect the LED’s and replace them if necessary. Ember LED’s are burnt out Inspect the ember bed LED’s and replace them if necessary.
SERVICE HISTORY This heater must be serviced annually depending on usage.