SIGNALING Access & Power Integration Combine Altronix Power and Accessories with Access Controllers from the Industry’s Leading Manufacturers Installation Guide All registered trademarks are property of their respective owners. More than just power.™ Rev. 101817 Installing Company: ______________________ Service Rep.
Overview: Trove accommodates various combinations of access controllers and accessories from the industry’s leading manufacturers with or without Altronix power supplies and accessories for access systems. A variety of backplanes offer a wide range of scalable access and power configurations. Trove simplifies board layout and wire management, while reducing installation and labor costs.
Installation Instructions: 1. Remove backplane from enclosure. Do not discard hardware. Fig. 1 2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws; level and secure. Mark the position of the lower holes. Remove the enclosure. Drill the lower holes and install the two/three fasteners.
Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Part I, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only, within the protected or restricted area. 1. The power supply is pre-wired to the ground (chassis). Connect main incoming ground to the provided green grounding conductor lead.
Terminal Identification: Terminal Legend L, G, N – DC + Trigger EOL Supervised (eFlow only) NO, GND RESET (eFlow only) + AUX – (eFlow only) AC Fail NC, C, NO Function/Description Connect 115VAC/120VAC 60Hz to these terminals: L to hot, N to neutral, G to ground (non power-limited) (ULXB - Fig. 3a, pg. 6, eFlow - Fig. 4a, pg. 6). AL300ULXB2 - 12VDC or 24VDC @ 2.5A continuous output (power-limited output) (Fig. 3d, pg. 6). AL400ULXB2 - 12VDC @ 4A or 24VDC @ 3A continuous output (power-limited output) (Fig.
Fig. 3 - ULXB configuration AC 5A 250V L G DC + DC --- 3d + BAT --- OFF --- 24V ON --- 12V ON 3e 3c BAT N BAT FAIL NC C NO NC C 3a NO AC FAIL 3b OFF --- 24V ON --- 12V ON Fig. 4 - eFlowNB configuration --- DC + 4h --- BAT + 4i 4g 3A 3A 32V 5A 250V 5A 250V AC1 L G 4a - 6 - N AC FAIL BAT FAIL AC DELAY SHUTDOWN O N NC C NO NC 4b C NO AC DC 1 min. 2 hr.
Trove1 Power Distribution Modules Configuration: Fig.
Trove1 MOM5 Configuration: Fig.
Trove1 ACM4(CB) Configuration: Fig.
Trove2 Power Distribution Modules Configuration: Fig.
Trove2 MOM5 Configuration: Fig.
Trove2 ACM Configuration: Fig.
TMV2 Sub-Assembly Configuration: Fig.
Trove3 ACM/PD Configuration: Fig.
eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network... LINQ2 - Network Communication Module LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels.
Notes: - 16 - Trove
Notes: Trove - 17 -
Trove1 Enclosure Dimensions: 18” x 14.5” x 4.625” (457.2mm x 368.3mm x 117.47mm) 14.5” (368mm) 7.25” (184.15mm) 1.45” (36.83mm) 1.25” (31.75mm) 4.5” (114.3mm) 1.948” (49.483mm) 13.0” (330.2mm) 1.5” (38.09mm) 1.25” (31.75mm) 1.5” (38.09mm) 0.5897” (14.98mm) 0.569” (14.52mm) 8.5” (215.9mm) 8.5” (215.9mm) 18.0” (457.2mm) 6.5” (165.1mm) 6.5” (165.1mm) 0.6012” (15.27mm) 1.0958” (27.83mm) 4.5” (114.3mm) 4.5” (114.3mm) 2.75” (69.85mm) 1.115” (28.32mm) 1.362” (34.59mm) - 18 - 1.25” (31.
Trove2 Enclosure Dimensions: 27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm) 21.50” (546.1mm) 2.00” (50.8mm) 5.25” (133.35mm) 3.50” (88.9mm) 3.50” (88.9mm) 5.25” (133.35mm) 0.685” (17.399mm) 1.25” (31.75mm) 0.5625” (14.29mm) 1.77” (44.96mm) 2.415” (61.34mm) Knockouts 1.125” (28.32mm) 0.885” (22.479mm) 6.25” (158.75mm) 0.85” (21.59mm) 6.25” (158.75mm) 1.25” (31.75mm) 19.80” (502.92mm) 1.5” (38.1mm) 2.00” (50.8mm) 6.75” (171.45mm) G 8.25” (209.54mm) 27.00” (685.8mm) 8.00” (203.2mm) 0.
Trove3 Enclosure Dimensions: 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm) 2.00” (50.8mm) 7.12” (222.25mm) 9.5” (241.3mm) 1.25” (31.75mm) 1.55” (39.37mm) 30.12” (768.1mm) 14.01” (355.9mm) 2.00” (50.8mm) 14.01” (355.9mm) 1.10” (27.9mm) 2.00” (50.8mm) 10.75” (273.1mm) 1.78” (45.21mm) 1.07” (27.2mm) 1.25” (31.8mm) 9.5” (241.3mm) 10.75” (273.1mm) G G 10.62” (269.8mm) 10.62” (269.8mm) 33.63” (854.20mm) 10.75” (273.1mm) 36.12” (917.5mm) 10.75” (273.1mm) 7.06” (179.3mm) 1.25” (31.