Video • Data • Power Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide Models Include: HubSat4Di - Four (4) Camera Channels HubSat42Di - HubSat4Di w/four (4) HubWayAv Video Balun/Combiners for 24VAC Cameras HubSat43Di - HubSat4Di w/four (4) HubWayDv Video Balun/Combiners for 12VDC Cameras Rev. 090209 More than just power.
Overview: Altronix HubSat4Di Passive UTP Transceiver Hub w/Integral Isolated Camera Power transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 4 camera channels in a wall mount enclosure. Video transmission range is up to 750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv or HubWayDv Video Balun/Combiners.
8. 9. 10. 11. 12. 13. 14. 15. The total cable distance must not exceed 750 ft. for video transmission between the HubSat4Di and each camera. Repeat this step for all other camera channels [PVD2-4]. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6) power LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4) and HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig.
3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6) power LEDs (Green) of the HubSat4Di will illuminate when AC power is present (Fig. 1e, pg. 4) and HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 2b, 2d, pg. 6). 4. Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to each camera to insure proper operation and avoid possible damage. 5.
10. The power LEDs (Green) of the HubSat4Di will illuminate when AC power is present (Fig. 1e, pg. 4). Note: If any of the power LEDs are not illuminated the cause may be due to the following: a. AC mains fail. b. Illuminated master power disconnect circuit breaker is tripped. Primary c. One or both primary in-line fuse(s) are blown. In-line Fuse Note: Replace fuse with same type and rating: Primary in-line fuses are rated @ 3.5A/250V (Fig. 4b, pg. 6). d.
Fig. 2 - HubWayAv and HubWayDv Video Balun/Combiners Fig. 2c Fig. 2a VIDEO VIDEO HubWayAv HubWayDv VIDEO BALUN/COMBINER CAT5 AC + DATA -- POWER + DATA -- Removable Terminal Block RJ45 Jack Fig. 2b To BNC Connector of Camera VIDEO BALUN/COMBINER Fig. 2d Green Power LED Structured Cable from HubSat4Di Removable Terminal Block RJ45 Jack AC Power to Camera To BNC Connector of Camera -- Data to + Camera HubWayAv passes AC voltage through pins 4, 5, 7, 8 and [AC Power] terminals.
Typical Application Drawing for HubSat4Di as a Passive UTP Transceiver Hub with Integral Camera Power: Fig.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.