PN - 240-00-0033 Revision 1.0 December 1, 2015 Altiostar Networks iRM4451 Remote Radio Head Product Description and Installation Guide Copyright© 2015 Altiostar All rights reserved.
iRM4451 RRH Product Description and Installation Guide Copyright © Altiostar Networks 2015. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner. Altiostar Networks, Inc., iR6, and Altiostar Networks, Inc. logo are trademarks of Radio Mobile Access, Inc. All other trademarks are the property of their respective owners. Disclaimer All rights reserved.
l Preface About the Manual This document covers the basic installation of the Altiostar Networks, Inc., iRM4451 Remote Radio Head (RRH) on towers, walls, roof or other structures utilizing a universal mounting assembly. Connections to external interfaces, including signaling, grounding, and power are described. Descriptions of the iRM4451 macro-cellular remote radio head indicators are also provided. Intended Users The target audience for this document is installation and engineering personnel.
l ii iRM4451 RRH Product Description and Installation Guide
Contents Contents 1 Introduction ....................................................................... 1-1 1.1 Target audience....................................................................... 1-1 1.2 Conventions used .................................................................... 1-1 1.3 eNodeB Overview .................................................................... 1-1 2 Safety requirements ........................................................... 2-1 2.1 Overview.....................
Contents iv IRM4451 RRH Product Description and Installation Guide
Introduction 1 Introduction This document covers the basic installation of the Altiostar Networks, Inc. iRM4451 macrocell wireless Remote Radio Head (RRH) on towers, walls, roof or other structures utilizing a universal mounting assembly. Connections to external interfaces, cabling, grounding and power are described. Descriptions of the iRM4451 connectors and indicators are also provided. 1.1 Target audience The target audience for this document is installation and engineering personnel 1.
Introduction — 1800 MHz (3GPP Band 3) — AWS (3GPP Band 4) — 2.6 GHz (3GPP Band 7) — AWS-1 & AWS-3 (3GPP Band 4 & AWS-3) Connection to other compliant fronthaul devices is facilitated through two available GigE optical Ethernet fronthaul ports. The iRM4451 interconnects with compliant radio antennas and the associated baseband unit, i.e., vBBU (or the optional iRB1200/iRB2400 iBBUs) which operate within the RAN portion of the LTE wireless network. A block diagram of the iRM4451 RRH is shown in Figure 1-1.
Safety requirements 2 Safety requirements 2.1 Overview This section provides safety precautions that apply to the iRM4451 . The precautions statements are required by national or regional standards institutes in the country or region where they apply. This document complies with these requirements. 2.2 Purpose To protect installation personnel, equipment and operations, this document contains safety statements.
Safety requirements when working on this type of equipment. Observe all local and national electrical, environmental and workplace codes. DANGER HAZARDOUS VOLTAGES! Hazardous voltages can be present when the system is operating. Use caution when removing or installing equipment. DANGER FALL HAZARD! A fall hazard is present when installation of this equipment requires working on towers, poles or at elevated work sites.
Safety requirements CAUTION • Never install equipment not identified in this procedure. Fire or injury could result from improperly installed equipment. • Caution should be exercised when installing or modifying telecommunications lines. • Disconnect all power sources before servicing the equipment. • Never touch uninsulated wiring or terminals unless power to the lines have been disconnected at the source. Always verify power has been removed using an approved voltage tester.
Safety requirements CAUTION CAUTION • Only trained and qualified personnel may install or service equipment as defined in IEC 215 and EN 60215. • Turn off or disconnect equipment from its energy source(s) by switching off the load disconnect switch in the distribution panel before performing service or maintenance. LASER RADIATION AND FIBER OPTIC CABLE USE CAUTION! • Class 1 invisible laser radiation present. Avoid long-term viewing of laser.
Safety requirements CAUTION • Leave equipment in their original anti-static wrapping until ready for installation. • When handling equipment or modules, use handles provided to carry the device and do not touch electrical contacts, pins or components. • Only place equipment or modules on conductive surfaces. • Use tools on equipment or modules only when equipment is grounded. • Handle defective equipment or modules similarly to new equipment to prevent additional damage.
Safety requirements 2-6 iRM4451 RRH Product Description and Installation Guide
Physical description 3 Physical description The Altiostar Networks iRM4451 Remote Radio Head is a compact, modular, outdoor radio unit constructed of aluminum with integrated heat sink fins to facilitate fanless convection cooling. Four independent RF outputs for a 4T4R configuration at 30 W per RF path for a total of 120 W maximum. The iRM4451 has connections for –48 V dc power input and Gigabit Ethernet optical fronthaul. Figure 3-2 shows the iRM4451 with the solar shield.
Physical description . Table 3-1 Altiostar Networks iRM4451 technical specifications iRM4451 Technical Specifications Frequency Bands Model Number Operation iRM44510200 PCS (3GPP Band 2) UL 1850–1910 MHz DL 1930–1990 MHz iRM44510300 1800 MHz (3GPP Band 3) UL 1710–1785 MHz DL 1805–1880 MHz iRM44510400 AWS (3GPP Band 4) UL 1710–1755 MHz DL 2110–2155 MHz iRM44510700 2.
Physical description Table 3-1 Altiostar Networks iRM4451 technical specifications (continued) iRM4451 Technical Specifications Working temperature (non-condensing humidity –40°F to 131°F (–40°C to 55°C) Operating altitude –197 to 9,843 ft (–60 to 3000 m) Relative humidity 5 to 100% Cooling Convection (fanless) 3.1 iRM4451 boards and modules The iRM4451 Remote Radio Head is an integral unit with no user accessible boards or modules. 3.
Physical description Figure 3-4 iRM4451 RET and -48v DC (power) connectors location Figure 3-5 iRM4451 GPS and fronthaul connectors location 3-4 iRM4451 RRH Product Description and Installation Guide
Physical description Figure 3-6 iRM4451 ground connector location Table 3-2 iRM4451 connectors Description –48V DC (GND) GPS Control/Connector Type Quantity Tyco TE CPC Series 5, 3-pin 1 Power input Dual-hole lug terminal 1 Equipment grounding SMA (female), 50 Ω 1 Timing source input Provides +24 V dc and RS-485 control function for AISGv2.
Physical description GPS cables are provided and pre-installed by the Operator. The GPS cable bend radius is ≤0.75 in (19 mm). 3.2.2 RF connectors There are four 50-Ω, 7/16 RF jacks (M29x1.5 threaded couplings) that terminate on the bottom of the iRM4451. They are marked ANT 1 through ANT 4.The RF cables are supplied and pre-installed by the Operator. The RF 7/16 connectors are secured by torquing the M29 screw ferrule 15–20 in-lb (20–28 Nm) using a torque wrench.
Physical description The RET cable can be daisy-chained to each of the PCS/AWS antenna inputs/ outputs served by the iRM4451. Antenna remote electrical tilt control is facilitated within the EMS user interface. 1 NC 2 NC 3 RS-485 B 4 NC 5 RS-485 A 6 +24 V dc 7 Dc return 8 NC Figure 3-8 RET 8-pin DIN connector 3.2.5 Fronthaul connectors Two Gigabit Ethernet (GigE) optical SFP ports provide connection for up to two duplex multi-/single-mode optical GigE cables.
Physical description Figure 3-9 Huber + Suhner Q-XCO fiber optic fronthaul cable The GigE optical fronthaul cables are supplied and pre-installed at the site by the Operator. NOTE There is a long lead time associated with ordering of this cable. Allow a minimum of 10 weeks lead time to ensure the cable is received at the time installation is to be performed. 3.2.6 LED indicators There are four LED indicators located on the right side of the iRM4451 as shown in Figure 3-10.
Physical description 1 2 1 Test Access Port (factory use only) 2 LEDs Figure 3-10 LED indicators Table 3-3 LED indicators description and operating characteristics Indicator Item No.
Physical description Table 3-3 LED indicators description and operating characteristics Indicator Item No.
Physical description Table 3-5 LED indicators boot-up sequence Indication Boot-up sequence for all LEDs Description Operation Steady GREEN 1 second, except POWER LED controlled separately by hardware state Steady RED 1 second Steady AMBER 1 second, except POWER LED stays RED OFF 1 second, except POWER LED stays RED Normal state n/a 3.2.
Physical description 3-12 iRM4451 RRH Product Description and Installation Guide
Installation prerequisites 4 Installation prerequisites This section contains information on the documentation, tools, equipment, and conditions required for performing the installation procedure. The document assumes that the target audience has reasonable industry experience, is qualified, and has installed wireless base stations in the past. 4.1 Required tools A typical telecommunications technician's toolkit is required to complete the iRM4451 installation.
Installation prerequisites Required Tools Nylon bridle sling, 2-leg, 2 in (5.1 mm) straps, 6x19 EIPS, or equivalent Pulley-minimum loadbearing capacity 880 lb (400 kg) Punch Wire stripper Rope - minimum breaking strength 600 lb (272 kg) (optional) Self-amalgamating waterproofing tape (e.g., Commscope Miracle Tape, Huber+Suhner Fast-Wrap, RFS CELLTape, EasyWrap® tape, etc.
Installation prerequisites • Grounding cable connecting the iRM4451 to the grounding point is supplied by the Operator and assembled on site unless otherwise specified. Altiostar Networks provides the two-hole lug for crimping onto the cable. • Power cable with plug connecting the iRM4451 to local –48 V dc power is supplied by the Operator and assembled on site unless otherwise specified. Operator must provide a lightning and surge suppression device on the power line to the unit.
Installation prerequisites Item Site pre-installation visit checklist 11 Verify main power supply is properly installed and tested and capable of supplying the required –48V dc voltage and current for proper operation of the iRM4451 system to within ±20% of rated output. 12 Verify –48V dc power cable to the iRM4451 is labeled and tested as specified in the Site Installation Plan.
Installation prerequisites Table 4-8 Site installation checklist Item Site installation checklist 9 Wear approved protective equipment such as hard hats, safety glasses, gloves, etc. when needed. 10 Verify pre-installation work specified in the Site Installation Plan is complete. 11 Verify the installation location of the iRM4451 meets the mounting requirements indicated in this document.
Installation prerequisites 4-6 iRM4451 RRH Product Description and Installation Guide
Installing the iRM4451 6 Installing the iRM4451 This section provides the procedure for installing the iRM4451 RRH in remote locations such as on towers, poles, masts, walls, roofs, or other structures utilizing a universal mounting assembly. Instructions for making connections to external interfaces, cabling, grounding and power are also provided. 6.1 Assembling cables The operator will need to order, pre-assemble, and pre-install various cables to the iRM4451. 6.1.
Installing the iRM4451 To install ground terminal lug: 1. Cut a 6 AWG (4.11 mm) stranded grounding cable the appropriate length for the iRM4451 installation. 2. Strip away insulation from one end to expose 3/4 in (19 mm) of bare wire. 3. Crimp the dual-lug grounding terminal (supplied) to the cable using the specialpurpose crimp tool specified in Required tools on page 4-1 (or equivalent) as directed by tool manufacturer instruction manual. Figure 6-12 shows an assembled cable/lug assembly.
Installing the iRM4451 Figure 6-13 iRM4451 cable routing 2. Secure and dress all cables according to Operator local practice. 6.3 Installing the iRM4451 mounting bracket This section provides the procedure for installing the iRM4451 on a mast/pole pipe, Vangle or H-angle, or mounting on a wall. The iRM4451 can be installed on a pole/mast structure having the following dimensions using the supplied mounting bracket assembly: Pole/mast:2.36-4.49 in (60-114 mm) U-frame:1.97-3.94 in (50-100 mm) V-frame:1.
Installing the iRM4451 NOTE The iRM4451 is shipped from the factory with the mounting plate preinstalled on the chassis as shown in Figure 6-14. Figure 6-14 iRM4451 mounting plate 6.3.1 Mounting on a pole/mast The following procedure provided instructions for mounting the iRM4451 on a pole/ mast using the supplied mounting bracket assembly. To install mounting plate on a pole or mast: 1. Install the mounting bracket and mounting clamp onto the pole/mast with mounting hardware as shown in Figure 6-15.
Installing the iRM4451 Figure 6-15 Installing mounting bracket on a pole NOTE IMPORTANT! Maintain the parallel orientation of the clamp and bracket while tightening the nuts. This will require alternating tightening the nuts on each screw stud until the final torque is achieved. 6.3.2 Mounting on a wall The following procedure provides instructions for mounting the iRM4451 to a wall or other flat, vertical surface.
Installing the iRM4451 NOTE NOTE The mounting clamp is not used when mounting the iRM4451 to a wall or other flat surface. In addition, the M12 bolts supplied in the hardware kit are not used for wall-mount applications. The Operator must provide four (4) M12 anchors, designed for outdoor use, that are compatible with the type structure on which the iRM4451 is to be installed. To install mounting plate on a wall: 1. Determine the location where the mounting bracket is to be installed.
Installing the iRM4451 NOTE WARNING Because of the differences Operator is responsible for determining an industry-approved, safe method of hoisting the iRM4451 into position onto elevated structures. Be sure to follow all established Operator local practice and safety precautions when hoisting the equipment on elevated structures. Figure 6-16 Hoist line carabiner attachment point 6.
Installing the iRM4451 To install iRM4451 on the mounting bracket: 1. Hang the iRM4451 chassis on the mounting bracket by aligning the mounting plate tabs on the rear of the chassis to the mounting bracket slots (see Figure 6-17). Figure 6-17 Aligning mounting plate tabs to mounting bracket 2. Lower iRM4451 onto the mounting bracket and align the tapped screw hole on top of the mounting plate with the tapped screw hole on the mounting bracket. 3.
Installing the iRM4451 To connect grounding cable: 1. Fasten the dual-hole grounding lug and cable assembly to the iRM4451 chassis grounding posts using two (2) M5-0.8 screws and washers (supplied by Operator). See Figure 6-18. Figure 6-18 Connecting the grounding cable 2. Tighten the bolts to 2.4 ft-lb (3.2 Nm) using a torque screwdriver. 3. 4. 5. 6. 6.1 Connecting the RET cables This section provides the procedure for connecting the RET cable to the RET connector socket. To connect RET cable: 1.
Installing the iRM4451 To connect GigE optical fronthaul cables: 1. Remove the captive dust cover of the FH1 fiber optic cable entry port by turning counterclockwise. 2. Remove the captive dust cover from the Huber + Suhner Q-XCO fiber optic cable connector by simultaneously squeezing the lock latches on either side of the quick-lock mating connector and turning the dust cover counterclockwise just past where the arrows come into alignment and pull, gently but firmly. 3.
Installing the iRM4451 NOTE It is recommended that the –48 V dc power connection be waterproofed using a self-fusing tape made for that purpose. The application of the tape will vary by Operator, so local practice will determine how the tape is applied. 3. Waterproof the connection by wrapping the connector with self-fusing tape (refer to Required tools on page 4-1) according to Operator local practice. 6.
Installing the iRM4451 6-12 iRM4451 RRH Product Description and Installation Guide
Terms, Acronyms and Abbreviations 7Terms, Acronyms and Abbreviations Term Description AWG American Wire Gauge AWS Advanced Wireless Services BBU Baseband Unit BOM Bill of Materials CBN Common Bonding Network CFR Code of federal regulations CPRI Common Public Radio Interface C-RAN Cloud-Radio Access Network DIN Digital Input EIPS Electronics Industry Pallet Specification EMS Enterprise Management System EN Engineering Note GPS Global Positioning System IEC International Electri
Terms, Acronyms and Abbreviations Term 7-2 Description SEMS Screw and Washer Assemblies SS Stainless Steel TX Transmit vBBU virtual Baseband Unit VDC or V dc Voltage direct current iRM4451 RRH Product Description and Installation Guide
iRM4451 installation overview 5 iRM4451 installation overview This section provides an overview of the installation procedures and instructions for installing the Altiostar Networks iRM4451 remote radio head. All required cabling for grounding, power, fronthaul, RF and optional GPS, are supplied by the Operator, as provided in the Site Installation Plan, and should already be preinstalled with drops to the iRM4451 remote radio head installation location, or according Operator local practice. 5.
iRM4451 installation overview NOTE It is important to report damage or material shortages to the shipping carrier while a representative is on site. If concealed damage or material shortages are found at a later time, contact the shipper to make arrangements for inspection and claim filing. 2. Remove packing materials. NOTE The shipping materials can be recycled. In some regions or countries it is mandatory that packing materials be recycled or re-purposed.
iRM4451 installation overview Table 5-9 iRM4451 parts list Qty Part number Part description 1 350-00-0009 Kit, accessory, grounding cable lug & nuts 1 350-00-0007 Kit, mounting hardware & screws 2 460-00-0014 Screw, M4-0.7 × 12 mm, cross-head pan, SEMS, SS 2 460-00-0020 Screw stud, M12-1.75 × 168 mm, SS 4 495-00-0001 Washer, flat, M12, max. 24 mm OD, SS 4 495-00-0002 Washer, split, M12, max. 24 mm OD, SS 4 445-00-0003 1 Nut, M12-1.