Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER AWI/AWO-20HPR1 Gamma AWI/AWO-26HPR1 Gamma AWI/AWO-35HPR1 Gamma AWI/AWO-54HPR1 Gamma AWI/AWO-71HPR1 Gamma AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1 Delta R ead This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
CONTENTS SOCIABLE REMARK Sociable remark......................................................................................................................2 SAFETY PRECAUTIONS Warning .................................................................................................................................3 Caution ..................................................................................................................................4 OPERATIING INSTRUCTIONS Parts names ........... ....
SOCIABLE REMARK When using this air conditioner in the European countries, the follow informations must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. Meanings of symbols used in this manual are as shown below. Never do this.
SAFETY PRECAUTIONS CAUTION When the air filter is to be removed, do not touch the metal parts of the unit. ! ! Ventilate the room well when used together with a stove, etc. Water may enter the unit and degrade the insulation. It may cause an electric shock. An oxygen shortage may occur. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not put a pet or house plant where it will be exposed to direct air flow. Do not use for special purposes.
OPERATING INSTRUCTIONS Parts names Indoor unit Indoor unit 2 4 5 1. 2. 3. 4. 5. 6. 7. 8. 3 1 7 6 AUTO COOL DRY HEAT 9 SET TEMP ERAT Outdoor unit URE ( C) FAN HIGH MED LOW TEMP MOD E ON/O FF SWING FAN SLEE P 8 DIRECAIR TION SPEE D TIME R ON RESET LOCK LED DISPL AY Front panel Air inlet Air filter Air outlet Horizontal air flow grille Vertical air flow louver Display panel Remote controller TIME R OFF TURB O 9. Connecting pipe, drain hose 10. Air inlet (side and rear) 11.
OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, see the <> packed with the unit for details.
OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow(Up--Down) direction Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction.
OPERATING INSTRUCTIONS How the air conditioner works SLEEP operation 1 Set Temperature 1 1 hour 1 hour Cooling SLEEP operation Set Temperature 1 1 1 hour 1 hour 7 hours timer off Heating DRYING operation Cooling Fan only Cooling Room temperature Fan only Cooling Time set temperature AUTO operation When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected a
CARE AND MAINTENANCE Care and maintenance Cleaning the Grille, Case and Remote Controller Household Drain Cleaner Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. No NOTE: Supply power must be disconnectd before cleaning the indoor unit. CAUTIONS Thinner A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit.
CARE AND MAINTENANCE 4. Remove the Air Freshening Filter(Optional filter included: Plasma Dust Collector/Silver Ion filter / Bio filter /Vitamin C filter/3M air purifier filter) from its support frame.(The removing and installation method are slightly difference, see the pictures marked 1 and 2 on the left. Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place.
OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just starting. B) Defrosting. C) Low temperature heating.
OPERATION TIPS 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation.
TROUBLESHOOTING TIPS Troubleshooting Tips Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again. Trouble Fuse blows frequently or circuit breaker trips frequently. Other objects or water penetrate the air conditioner.
CS421-U