Data Sheet

Product Specification Sheet APS285 - Rev. 07/2013
232I Indoor Keypad Station (Flush Mount)232I Indoor Keypad Station (Flush Mount)
Alpha CommunicationsAlpha Communications
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-559942 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.comTOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyrigh1998-2016 Alpha Communications® - All Rights Reserved.
Due to continuous product improvement, all colors, sizes, materials, finishes and specifications are subject to change without notice.
Architects' And Engineers'Architects' And Engineers'
SpecificationsSpecifications
The access control system shall be Alpha
Communications®/IEI model 232I keypad
or approved equivalent. The keypad
memory shall have nonvolatile
EEPROM memory for up to 120 users.
Codes may be from 1-6 digits in length
and digits may be repeated.
Assisted by the door position sensor
input, this 1 amp Form-'C' relay shall
energize if the door is opened without a
valid user entry or egress input. This
output can be programmed to energize for
up to 15 minutes or latch. It can be reset
by a valid code entry.
The systems propped door relay can be
programmed for a 1 to 15 minute time
window in which the door may be held
open after a valid entry. The system shall
alert the resident to any "propped" door
by energizing a 1 amp Form 'C' relay. This
output may be wired to a siren, buzzer,
guard station, camera or any other
device.
The lock release relay is rated a 8 amps
and is tough enough to handle any locking
device. Simple programming allows the
output to toggle (by code) or time from 1
to 90 seconds.
232I Flush Mount Indoor Keypad232I Flush Mount Indoor Keypad
The 232I keypad offers field proven reliability and cost effective solutions for residential,
commercial and industrial installations, elegant yet durable, it blends with any decor.
Designed for compatibility with any electric locking device. The keypad accept power from
any 12-24V AC/DC supply. No separate programmer is ever necessary.
FeaturesFeatures
Lock release relay
Lock release timer
Forced door alarm relay and Propped door alarm relay
Alarm zone shunting relay
Timed egress input
120 user capacity
Front Programming
Flush mount Indoor Design
Mechanical SpecificationsMechanical Specifications
Dimensions:
(Re a der)
Height: 4.50" (114.3mm)
Width: 1.75" (44.4mm)
Depth: 1.55" (39.4mm)
Dimensions:
(Program m ing Ke ypa d )
Height: 4.50" (114.3mm)
Width: 2.75" (69.9mm)
Depth: 2.50" (63.5mm)
Electrical SpecificationsElectrical Specifications
Voltage:
12 to 24 volts AC or DC (selected by jumper)
(Norm a lly us e d with m ode l SS106 p igta il or m o del T 1240 plug-in transfo rm e r)
Current:
@12VDC 20mA typical, 50mA worst case
@24VDC 25mA typical, 70mA worst case
Note:
Keypads using additional relays require an additional 15mA for each
relay energized.
Outputs:
Main relay: 8 Amp, Form 'C' @24VDC-10 Amp surge
Alarm Zone Shunting Relay: 1 Amp, Form 'C' @24VDC
Forced Door Relay: 1 Amp, Form 'C' @24VDC
Propped Door Relay: 1 Amp, Form 'C' @24VDC
Wire Distance: 250' between reader and electronics with #22AWG
Environmental SpecificationsEnvironmental Specifications
Temperature: -20°F to 130°F (-28°C to 54°C)