AT-MC105XL AT-MC106XL Fast Ethernet Media Converters Installation Guide PN 613-10800-00 Rev.
Copyright 1999 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from AlliedTelesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. AlliedTelesyn International, Corp.
Safety and Interference Warnings STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Safety and Interference Warnings............................................................. iii AT-MC105XL and AT-MC106XL Fast Ethernet Media Converters ...... 1 Key Features....................................................................................................... 2 LEDs.................................................................................................................... 2 MDI/MDI-X Switch .......................................................................
AT-MC105XL and AT-MC106XL Fast Ethernet Media Converters The AT-MC105XL and AT-MC106XL convert IEEE 802.3u 100Base-TX to 100Base-SX multimode Fast Ethernet network connections. The 100Base-SX interface is available in ST or SC connectors for multimode fiber cabling. The 100Base-TX interface uses an RJ45 shielded connector.
Key Features The media converters have the following key features: ❑ LEDs for unit and port status ❑ MDI/MDI-X Switch ❑ NML/LNK TST Switch ❑ 100Base-TX ports participate in auto-negotiation for 100 Mbps and half- or full-duplex modes ❑ MissingLink provides link fault detection on 100Base-TX segments ❑ External AC-DC Power Adapter ❑ Standard, compact size for use with AT-MCR12 rack-mount chassis ❑ Low power consumption Note For definitions of technical terms associated with Allied Telesyn p
AT-MC105XL and AT-MC106XL Installation Guide NML/LNK TST Switch The NML/LNK TST (Normal/Link Test) switch, located on the front panel, establishes a fiber/twisted pair link in the test position. The default position of the switch is IN, which is the normal (NML) operating mode and enables the MissingLink feature. With the switch in the OUT or Link Test Mode (LNK TST) position, the MissingLink feature is disabled and the optical transmitter TX is forced on.
External AC-DC Power Adapter An external AC-to-DC power adapter is included with the fast switch for standalone operation (see Figure 3).The power adapter supplies 12 volts DC to the media converter. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 and 240 V AC versions with an unregulated outp of 12 V DC at 1 A. The power required for the media converter is 12 V DC, 500 mA.
AT-MC105XL and AT-MC106XL Installation Guide Installing the Media Converter Read the warnings below before beginning any installation. Warning LIGHTNING DANGER: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY! 1 DO NOT BLOCK AIR VENTS ! 2 The following steps are for a standalone installation. To install media converters in a rack-mount chassis, see “Rack-mount Chassis Installation” on page 7.
9. If you are making a direct connection to a workstation using straightthrough cable, set the MDI/MDI-X switch to the MDI-X position. (MDI-X is the default position.) If you are connecting the media converter to a hub, switch, or another media converter with a straight-through cable, set the MDI/MDI-X switch to the MDI position. See Figure5.
AT-MC105XL and AT-MC106XL Installation Guide Back-to-Back Installation Review the following before doing a back-to-back installation. See Figure8 f or an illustration of a back-to-back-media converter configuration. ❑ During installation, setup, and testing of back-to-back media converters, make sure each media converter is in the Link Test Mode.
Configurations Figure 7 shows a typical network configuration with a workstation connected to a switch. AT-8124XL 10/100 Switch PORT ACTIVITY RS-232 TERMINAL PORT AT-MC105XL STATUS 10BASE-T / 100BASE-TX 10BASE-T / 100BASE-TX SWITCH FAST ETHERNET 100Base-TX 100Base-SX MMF Legend 10 Mbps 100 Mbps 100 Mbps (Fiber) Workstation Figure 7 Connection to Workstation and Switch Figure 8 shows two media converters in a back-to-back configuration.
AT-MC105XL and AT-MC106XL Installation Guide Troubleshooting To troubleshoot your media converter,perform the following: 1. Set the unit in the Link test Mode. 2. End stations used with the media converter must operate in the same duplex mode (either both full-duplex or both half-duplex). 3. Verify that the twisted pair cable is Category 5. 4. Verify that proper fiber cable is being used: multimode for the AT-MC105XL and AT-MC106XL. 5.
Recommended Cables and Cable Specifications Table 3 lists the IEEE 802.3u cabling specifications for the media converters. Refer to this table for cabling recommendations. Table 3 IEEE 802.3u Cabling Specifications for AT-MC105XL and AT-MC106XL 100Base-SX 100Base-TX Media 850 nm multimode fiber, 50/125 micron 850 nm multimode fiber, 62.
Appendix A Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commissi RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
NORMEN: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen Hochfrequenzstörung EN55022 Klasse A WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen. Störsicherheit EN50082-1 ACHTUNG: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den Richtlinien für Emission und Interferenzschutz entsprochen wird.
AT-MC105XL and AT-MC106XL Installation Guide EISEN: Dit product voldoet aan de volgende eisen. RFI Emissie EN55022 Klasse A WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. Immuniteit EN50082-1 WAARSCHUWING: Om te voldoen aan de emissie- en immuniteitsnormen dient dit apparaat te zijn voorzien van afgeschermde kabels.
STANDARDI : Tämä tuote on seuraavien standardien mukainen Radioaaltojen häirintä EN55022 Luokka A VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. Kestävyys EN50082-1 VAROITUS: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja häiriönsietostandardien mukaisesti.
AT-MC105XL and AT-MC106XL Installation Guide SIKKERHETSNORME : Dette produktet tilfredsstiller følgende sikkerhetsnormer RFI stråling EN55022 Klasse A ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. Immunitet EN50082-1 ADVARSEL: Dette produktet må brukes med vernede kabler for å tilfredsstille emisjons- og fritakelsesstandarder.
ESTÁNDARES: Este producto cumple con los siguientes estándares Emisión RFI EN55022 Clase A ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. Inmunidad EN50082-1 ADVERTENCIA: Este producto exige cables protectores para ajustarse a las normas de emisión e inmunidad.
Appendix B AT-MC105XL and AT-MC106XL Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name ________________________________________________________________________ Company _____________________________________________________________________ Address ______________________________________________________________________ City_____________________________State/Province__________________________________ Zip/Postal Code _______________________ Country__________________________________ Phone___________________________________ Fax____________________________
Appendix D Where To Find Us For Technical Support or Service Location Phone Fax Americas United States, Canada, Mexico, Central America, South America 1 (800) 428-4835 1 (918) 628-3222 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India (+65) 3815-613 (+65) 3833-830 Australia Australia, New Zealand (61) 2-943-5111 (61) 2-9438-4966 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa (+33) 1-60-92-15-32 (+33) 1-69-28-37-49 Germany German