Aleis ISO-FFW Series Operational Manual Reader User Guide ISO-FFW Series Reader ISO-FFW-6000 Standard unit with Read and On LEDs Only ISO-FFW-8030 ISO-FFW-8030-EXP ISO-FFW-8030- EXP-CLK Display and 8030 Keypad With 9000 expansion board fitted With 9000 expansion board and Clock fitted ISO-FFW-9060 ISO-FFW-9060EXP ISO-FFW-9060- EXP-CLK Display and 9060 Data Entry Keypad With 9000 expansion board fitted With 9000 expansion board and Clock fitted Version 1.
Aleis ISO-FFW Series Operational Manual TABLE OF CONTENTS Regularity Notices and Conformity .....................................................................................................................................................4 ISO-FFW Series Reader Instructions ..................................................................................................................................................5 1.0 The Aleis ISO-FFW Series System ................................................
Aleis ISO-FFW Series Operational Manual 14.3 Templates ...........................................................................................................................................................................26 14.4 Data Entry using Function Keys for a pre made Template.................................................................................................29 14.5 How to: Upload RFIDs into the Reader .................................................................................
Aleis ISO-FFW Series Operational Manual REGULARITY NOTICES AND CONFORMITY USA – FCC Information to the user (FCC Part 15.105) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Aleis ISO-FFW Series Operational Manual Important User Instructions ISO-FFW SERIES READER INSTRUCTIONS IMPORTANT Must be read prior to using system The following instructions must be wholly adhered to or permanent damage to the antenna/reader and/or permanent data loss can occur. Non-conformance to the handling and operating instructions will immediately void all warranties for the antenna/reader and software. 1.
Aleis ISO-FFW Series Operational Manual 1.
Aleis ISO-FFW Series Operational Manual 2.0 PREPARATION FOR USE When you have mounted your Aleis ISO-FFW Series Reader, and you are ready to use it, please ensure the following steps are closely followed: When inserting or attaching a new electronic RFID device into or on an animal, keep all other electronic RFID devices a minimum of 3 meters away from the Aleis ISO-FFW Series Reader. This will ensure you only read the device you are inserting or attaching.
Aleis ISO-FFW Series Operational Manual 5.0 METHODS OF CONNECTION There are two general methods of connecting your Aleis ISO-FFW Series System. 5.1 Direct connection with your scale indicator: The Aleis ISO-FFW Series Reader is compatible with all scale indicators accepting the standard RFID format from a reader. You may need to contact your scale indicator manufacturer for setup instructions.
Aleis ISO-FFW Series Operational Manual 6.0 OPTIONAL POWER Only use high quality regulated linear power supplies or solar panels. Please contact Aleis with any queries, you may have. Some switch mode power supplies are NOT suitable and must not be used. 7.0 USING EXTERNAL POWER SUPPLY If you purchased a ISO-FFW System without a power supply, then you will need to use an power supply to power the reader. An external 12 volt battery can be used, or an regulated linear power supply.
Aleis ISO-FFW Series Operational Manual 9.1 How to: Read & Store RFIDs 1. 2. 3. Turn the 8030 Series Reader ON. When Reading Press the button on the wand and wave the wand past the RFID device ear tag or rumen pellet. When reading rumen pellets, simply wave the wand in a reverse ‘L’ pattern behind the front leg of the animal, or in front of the brisket.
Aleis ISO-FFW Series Operational Manual Step 1: Creating a file to upload into the reader. Creating the file to upload into the reader is very easy. You can do this in Microsoft Excel or Wordpad or Notepad. All you need to do is have a list of RFIDs with the word TAG as the first entry, ie at the top of the list.
Aleis ISO-FFW Series Operational Manual 11. Scroll down to Alert and press the OK button. 12. Ensure Condition is highlighted and press the OK button. 13. Scroll down to On Match and press the OK button – you will see a tick appear in the box. 14. Press the C button (located beside the MENU button). 15. Scroll down to Action and press the OK button. 16. Scroll down to Msg, LEDs, Buzzer and press the OK button – you will see a tick appear in the box. 17.
Aleis ISO-FFW Series Operational Manual 9.6 Formatting the File System Formatting of the file system is very important to keep your reader operating at its maximum performance. Once the reader has read and stored a lot of tags eg 40000+ you may notice a slow down in its performance when storing and recalling data. This is similar to your PC when the Hard Drive gets full. When you clear the reader it doesn’t actually remove the data so you can retrieve it if you accidentally have cleared the reader.
Aleis ISO-FFW Series Operational Manual 10.0 ISO-FFW8030 MENU TREE The readers menu has 5 main menu and several sub menu items Session Read Setup System Setup Reader Information Memory Status 10.
Aleis ISO-FFW Series Operational Manual 10.
Aleis ISO-FFW Series Operational Manual 10.
Aleis ISO-FFW Series Operational Manual 10.4 Reader Information Menu 10.
Aleis ISO-FFW Series Operational Manual 11.0 ISO-FFW8030 AUDIO AND VISUAL ALERTS Features Buzzer LCD Display Valid READ One beep Current RFID number, eg. READ LED blinks once 971 000000002861, at top of screen Valid READ & ID STORED Two beeps Current RFID number, eg. READ and STORED LED’s 971 000000002861, at top of blink once screen, and counter at bottom right of screen will increase. No ID Read One long beep (after read on time out) NO RFID READ No RF Signal being received.
12.0 ISO-FFW8030 MENU Main Menu (Reader selection choices) 12.1 Session 12.11 New Starts a New Session 12.12 Send to PC Sends the RFIDs in the memory to the PC There are two options: Current Session All Sessions 12.13 Clear Clears the readers memory. There are two options: Current Session All Sessions 12.14 Select - Selects the session on the reader . Any RFIDs read will be stored in the session selected 12.2 Read Setup 12.21 12.
Aleis ISO-FFW Series Operational Manual On Match On No-Match No Send 12.3 System Setup 12.
Aleis ISO-FFW Series Operational Manual (Select required contrast Eg 90 = light contrast. 120= very dark. Subject to viewing angle) 12.33 Buzzer Turns the Buzzer On/Off Off On 12.34 Sleep Timer Sets the Sleep Timer. The unit will turn off to save battery power if it is not used in the selected time 5 Minutes 15 Minutes 30 Minutes Disabled 12.35 Read Timer Sets the read timer for handheld mode 3 Seconds 5 Seconds 10 Seconds Continuous 12.
Aleis ISO-FFW Series Operational Manual Sets TX sync mode to master or slave unit (only applicable to Wired Sync Mode). Slave Master 12.4 Reader Information (This is for technical assistance only & product identification) Reader Info Hardware: Software: Date: Serial No: Reader Type: (Hardware Version) (Software Version) (Software Date) (Reader Serial Number) (Aleis Reader Model) 12.
Aleis ISO-FFW Series Operational Manual 13.
Aleis ISO-FFW Series Operational Manual 14.0 ISO-FFW9060 READER METHODS OF USE There are four general methods of reading and recording data. Please read each method and follow instructions covering the method you choose with your 9060 series system. 14.1 Record RFID No’s only (no data entry) 1. Turn Reader ON. (If a previous session is still on screen press F3, go to step 4 below and start a new session) 2. Read animal. 3. When finished reading, press F3 and turn reader OFF.
Aleis ISO-FFW Series Operational Manual Field Default Data When setting up template there is no need to have a date field as this will record automatically and print with the report. There are four data fields available per template. 8. Field column allows for three letters/numbers only for each field. If recording information for a, tag number, pregnancy result, weight, vaccination, dose rate or paddock.
Aleis ISO-FFW Series Operational Manual 17. Session will be highlighted, press OK. 18. New will be highlighted, press OK. Follow same instructions from beginning. If same fields are required, select Same Fields instead of Blank (as in step 5) 14.3 Templates Setup New Template Lock Template Save Template Change Template Remove Template Setup New Template 1. Press MENU. 2. Session is highlighted – press OK. 3. Press down arrow once to Data Entry Setup. 4. Press OK. 5.
Aleis ISO-FFW Series Operational Manual TAG WGT P/E PAD 8. River When finished, press C (located to the left of MENU button) to return to the session screen. Lock Template 9. From Session press down arrow to select Data Entry Locking. 10. Press OK. 11. By pressing OK in any box locks data to prevent it accidentally being changed when typing data into reader. An X appears in box when locked.
Aleis ISO-FFW Series Operational Manual 19. When finished press OK. 20. Message appears Template Saved, press OK. 21. Press C three times to return to main reading screen. 22. Reader is ready to read first group of animals. 23. This process can be carried out well before using the reader.
Aleis ISO-FFW Series Operational Manual 14.4 Data Entry using Function Keys for a pre made Template 9060 Series Function Keys 9060 series Function Keys are designed to make entering data into reader simple and quick. The function of each key is explained to the right of that key, as an example, the F1 key is used to start a new session. These Function Keys are linked directly to created Templates in reader.
Aleis ISO-FFW Series Operational Manual 14.5 How to: Upload RFIDs into the Reader The feature of uploading RFIDs into the 9060 reader is to allow you to find particular RFIDs that you need to identify. For example, if you need to find a particular animal that was treated with a certain medicinal treatment, you can upload the RFID into the reader.
Aleis ISO-FFW Series Operational Manual Step 2: Upload the files into the reader. 9. Open up Aleis DataLink. 10. Once the software has found the reader, click on the Open button located at the left side of the DataLink screen (there is a big yellow manilla folder on the button). 11. Find the file that you created, and click on the open button. 12. You will see that file name listed in the main screen of Aleis DataLink where the session names and numbers are normally displayed. 13. Click on that file name.
Aleis ISO-FFW Series Operational Manual 14.7 Formatting the File System Formatting of the file system is very important to keep your reader operating at its maximum performance. Once the reader has read and stored a lot of tags eg 40000+ you may notice a slow down in its performance when storing and recalling data. This is similar to your PC when the Hard Drive gets full. When you clear the reader it doesn’t actually remove the data so you can retrieve it if you accidentally have cleared the reader.
Aleis ISO-FFW Series Operational Manual 15.0 ISO-FFW9060 MENU TREE The readers menu has 5 main menu and several sub menu items Session Read Setup System Setup Reader Information Memory Status 15.
Aleis ISO-FFW Series Operational Manual 15.
Aleis ISO-FFW Series Operational Manual 15.
Aleis ISO-FFW Series Operational Manual 15.4 Reader Information Menu 15.
Aleis ISO-FFW Series Operational Manual 16.0 ISO-FFW9060 AUDIO AND VISUAL ALERTS Features Buzzer LCD Display Valid READ One beep Current RFID number, eg. READ LED blinks once 971 000000002861, at top of screen Valid READ & ID STORED Two beeps Current RFID number, eg. READ and STORED LEDs 971 000000002861, at top of blink once screen, and counter at bottom right of screen will increase. No ID Read One long beep (after read on time out) NO RFID READ No RF Signal being received.
Aleis ISO-FFW Series Operational Manual 17.0 ISO-FFW9060 MENU 17.1 Session 17.11 New 17.12 Starts a New Session Data Entry Setup - Sets up Data Entry Fields 17.13 Data Entry Locking - Sets up Data Entry Locking Fields 17.14 Templates Session Template Save Template Default Template 17.15 Send to PC Sends the RFIDs in the memory to the PC There are two options: Current Session All Sessions 17.16 Clear Clears the readers memory. There are two options: Current Session All Sessions 17.
Aleis ISO-FFW Series Operational Manual Action Sets the Alert Action There are 3 options: Msg = Message on screen Msg,LED’s = Message & Lights Msg, LED’s, Buzzer = Message, Lights & Buzzer Duration Sets the Alert Duration. There are 4 options 2 Seconds 5 Seconds 10 Seconds Until Keypress Message – Sets up Message 17.24 17.
Aleis ISO-FFW Series Operational Manual ISO 26 Digit ISO 27 Digit 15 Digit 16 Digit Scale Interface Sets scale type, overrides Tag Output Format, Serial Baud Rate, and Download Format to suit the scale’s requirements. No Scales Ruddweigh Thunderbird Tru-Test 17.32 Display Backlight Threshold (Select required lighting Eg 1 = always bright. 16 = will come on when very dark. Subject to Backlight Mode selection below) Backlight Mode Sets the condition when the Backlight comes on.
Aleis ISO-FFW Series Operational Manual 17.37 Set Date/Time -Sets Date and Time 17.38 RFM Settings FDX/HDX Mode Sets the readers FDX/HDX mode FDX/HDX With Boost FDX Only HDX Only With Boost FDX/HDX FDX/HDX Rx Only Ant Tune Mode Selects Auto or manual antenna tuing.
Aleis ISO-FFW Series Operational Manual 17.5 Memory Status Used Memory X% Free Memory X% Reclaimable Memory X% 18.0 Percentage of Used Memory Percentage of Free Memory Percentage of Recoverable Cleared Memory (old Sessions) ISO-FFW SERIES READER SPECIFIACTIONS General Frequency: RFID Compatibility: User Interface: RS-232 Port: RFID Code output: Antenna Tuning: User Options: Battery Power: 134.2Khz ISO 11784 &11785 HDX and FDX-B RS-232 Serial Port/Bluetooth Option.
Aleis ISO-FFW Series Operational Manual 19.0 ALEIS CONDITIONS OF SALE In these conditions: `Vendor' means Aleis Pty Ltd ACN 081 411 734 of Cnr Old Rosevale & Jandowae/Kingaroy Roads, Jandowae, Queensland, 4410 which is the seller of the goods ‘Factory’ means the Vendor’s principal place of business at Cnr Old Rosevale & Jandowae/Kingaroy Roads, Jandowae, Queensland,4410. Purchaser' means the customer(s) described overleaf which is the purchaser of the goods.
Aleis ISO-FFW Series Operational Manual all freight is paid by the purchaser. (2) If goods are not manufactured by vendor the guarantee of the manufacturer thereof shall be accepted by the purchaser and is the only guarantee given to purchaser in respect of the goods.
Aleis ISO-FFW Series Operational Manual 19. Vendor shall not be under any obligation to accept goods returned by the purchaser and will do so only on terms to be agreed in writing in each individual case. 20. All goods to be supplied by vendor shall be as described on the quotation overleaf and the description on such order modified as so agreed shall prevail over all other descriptions including any purchaser's specification or inquiry. 21.