Reader User Guide ISO9161 & ISO9162 Including Aleis DataLink Version Draft A 18/06/2009 Fixed Race Reader IMPORTA T! This User Guide must be read in conjunction with Reader, prior to use. ©Copyright Aleis Pty Ltd 2009 13429 A1064AUS Aleis Pty Ltd PO BOX 63 Jandowae 4410 QLD Australia ACN 130 754 826 www.aleis.
Aleis ISO9060 Series Operational Manual Aleis ISO9060 Series Page 2 of 43
Aleis ISO9060 Series Operational Manual 9060 Reader Instructions Regularity otices and Conformity ................................................................................................................................ 4 Important User Instructions ............................................................................................................................................ 5 1.0 The Qwerty Keypad......................................................................................
Aleis ISO9060 Series Operational Manual Regularity otices and Conformity USA – FCC Information to the user (FCC Part 15.105) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Aleis ISO9060 Series Operational Manual Important User Instructions IMPORTA T: Must be read prior to using system The following instructions must be adhered to or permanent damage to the antenna/reader and/or permanent data loss can occur. Non-conformance to the handling and operating instructions will immediately void all warranties for the antenna/reader and software. 1. Battery must be charged every two months and for maximum performance, batteries need to be charged before and after use. 2.
Aleis ISO9060 Series Operational Manual 21. For race systems: The race antenna must be fastened to the wooden panel by four bolts in the holes provided—two in the top of the antenna, and two in the bottom of the antenna. 22. Aleis DataLink is a free single user program for producers to transfer cattle to the LIS database. 23. Aleis Conditions of Sale apply at back of User Guide.
Aleis ISO9060 Series Operational Manual 1.
Aleis ISO9060 Series Operational Manual 2.0 9060 Series Reader Methods of Use There are four general methods of reading and recording data. Please read each method and follow instructions covering the method you choose with your 9060 series system. 2.1 Record RFID o’s only (no data entry) 1. Turn Reader O . (If a previous session is still on screen press F3, go to step 4 below and start a new session) 2. Read animal. 3. When finished reading, press F3 and turn reader OFF.
Aleis ISO9060 Series Operational Manual 7. A table heading will appear. Field Default Data When setting up template there is no need to have a date field as this will record automatically and print with the report. There are four data fields available per template. 8. Field column allows for three letters/numbers only for each field. If recording information for a, tag number, pregnancy result, weight, vaccination, dose rate or paddock.
Aleis ISO9060 Series Operational Manual 17. Session will be highlighted, press OK. 18. ew will be highlighted, press OK. Follow same instructions from beginning. If same fields are required, select Same Fields instead of Blank (as in step 5) 2.3 Templates Setup New Template Lock Template Save Template Change Template Remove Template Setup ew Template 1. Press ME U. 2. Session is highlighted – press OK. 3. Press down arrow once to Data Entry Setup. 4. Press OK. 5.
Aleis ISO9060 Series Operational Manual Field TAG WGT P/E PAD 8. Default Data River When finished, press C (located to the left of ME U button) to return to the session screen. Lock Template 9. From Session press down arrow to select Data Entry Locking. 10. Press OK. 11. By pressing OK in any box locks data to prevent it accidentally being changed when typing data into reader. An X appears in box when locked.
Aleis ISO9060 Series Operational Manual 18. Type in template name. 19. When finished press OK. 20. Message appears Template Saved, press OK. 21. Press C three times to return to main reading screen. 22. Reader is ready to read first group of animals. 23. This process can be carried out well before using the reader.
Aleis ISO9060 Series Operational Manual 2.4 Data Entry using Function Keys for a pre made Template 9060 Series Function Keys 9060 series Function Keys are designed to make entering data into reader simple and quick. The function of each key is explained to the right of that key, as an example, the F1 key is used to start a new session. These Function Keys are linked directly to created Templates in reader.
Aleis ISO9060 Series Operational Manual 2.5 How to: Upload RFIDs into the Reader The feature of uploading RFIDs into the 9060 reader is to allow you to find particular RFIDs that you need to identify. For example, if you need to find a particular animal that was treated with a certain medicinal treatment, you can upload the RFID into the reader.
Aleis ISO9060 Series Operational Manual Step 2: Upload the files into the reader. 1. Open up Aleis DataLink. 2. Once the software has found the reader, click on the Open button located at the left side of the DataLink screen (there is a big yellow manilla folder on the button). 3. Find the file that you created, and click on the open button. 4. You will see that file name listed in the main screen of Aleis DataLink where the session names and numbers are normally displayed. 5. Click on that file name. 6.
Aleis ISO9060 Series Operational Manual 2.7 Formatting the File System Formatting of the file system is very important to keep your reader operating at its maximum performance. Once the reader has read and stored a lot of tags eg 40000+ you may notice a slow down in its performance when storing and recalling data. This is similar to your PC when the Hard Drive gets full. When you clear the reader it doesn’t actually remove the data so you can retrieve it if you accidentally have cleared the reader.
Aleis ISO9060 Series MENU Memory Status Reader Information System Setup Read Setup Session 9060 Series Menu Tree Turn Unit ON 3.
No RF Signal being received. Two very quick beeps (every 30 seconds) Aleis ISO9060 Series No Charge—unit will turn off Half Charged Fully Charged Legend for LCD Visual Displays. Battery Level Indicator (Solid) Connected BATTERY LOW Page 18 of 43 (Flashing) Flashes as unit is about to turn off. 6 Auxiliary LEDs – 3 each side of the screen No Signal—no IDs will be sent. Signal at 2/3 Strength Signal at Full Strength RF Signal Indicator Current RFID number, eg.
Aleis ISO9060 Series Operational Manual 5.0 Menu Main Menu (Reader selection choices) 5.1 Session ew New Session From Template Blank Same Fields Data Entry Setup - Sets up Data Entry Fields Data Entry Locking - Sets up Data Entry Locking Fields Templates Session Template Save Template Default Template Send to PC Send to PC Current Session All Sessions Clear Clear Current Session All Sessions Change ame - Changes Sessions Name Select - Selects Session number and count.
Aleis ISO9060 Series Operational Manual 5.2 Read Setup Load/Save Profile: Load Profile Save Profile Load defaults – (Resets Read Setup to factory defaults.
Aleis ISO9060 Series Operational Manual 5.3 System Setup Communications Interface Select Interface Serial RF Modem Bluetooth Protocol Select Protocol: Tiris Aleis Combined (Tiris/Aleis) Allflex USA Serial Baud 9600 38400 57600 115200 Tag Format ISO 26 Digit ISO 27 Digit 16 Digit Scale Interface No Scales Ruddweigh Thunderbird Tru-Test Display Backlight Threshold (Select required lighting Eg 1 = always bright. 16 = will come on when very dark.
Aleis ISO9060 Series Operational Manual Read Timer Read Timer 3 Seconds 5 Seconds 10 Seconds Continuous Load Defaults Load Defaults 8030/50 Series 9030/50/60 Series Set Date/Time -Sets Date and Time 5.4 Reader Information (This is for technical assistance only & product identification.) Reader Info: Hardware: Hardware Version. Software: Software Version. Date: Software Date Serial o: Reader Serial Number. Reader Type: Aleis Reader Model. 5.
Aleis ISO9060 Series Operational Manual 6.0 Battery Charging ( ISO9162 only) The batteries in the unit should only be charged by using the 9-pin connector on the side of the unit. 6.1 Battery Charging Requirements • Charge unit using supplied charger only. • Aleis suggests a form of transient protection unit be used while charging the reader to help prevent power surges/spikes. • Do not use Reader while it is being charged.
Aleis ISO9060 Series Operational Manual 6.3 Battery Charging Options An optional Car Cigarette Lighter Battery Charger is available. 6.4 Alternative Recharging Methods Contact Aleis for alternative methods of charging. 7.0 The Clock The clock on the 9060 Reader is what will put the date and time stamp on each RFID that is read by the reader. To reset or change the date and time on the clock, simply plug the 9060 Reader into your computer, turn the reader on, and then open Aleis DataLink.
Aleis ISO9060 Series Operational Manual Aleis DataLink Software 9.0 Aleis DataLink Software IMPORTA T Must be read prior to using software This software has been purposefully designed to download the RFID’s and/or respective data relating to those RFID’s from the Aleis 7000 8030/50 and 9030/50/60 Series Readers. Aleis accepts no responsibility for any form of improper use, negligent or otherwise, resulting in the loss of RFID’s with the use of this software.
Aleis ISO9060 Series Operational Manual 9.1 Aleis DataLink Installation To install DataLink: 9.2 1. Place the DataLink CD into the CD drive; the program will automatically begin installation. If not Go to My Computer Double click on the CD Rom Drive Browse the CD and Double click on the icon called DataLink 2. Follow the installation prompts, and click on Finish when installation is complete.
Aleis ISO9060 Series Operational Manual 9.
Aleis ISO9060 Series Operational Manual 9.4 Producer Transfer (Australia Only) This opens the NLIS Transfer Wizard, using the selected fields in the current session(s). This button is used for Producer to Producer transfers. For further information please use the help feature in Aleis DataLink. Producer Transfer Steps Step 1 Click on the "Producer Transfer" button.
Aleis ISO9060 Series Operational Manual Step 3 After completing the form Click on "Next" If you choose to tick the Upload Later box the Transfer will not be completed but you can complete the transfer at any time by resuming the upload from the Upload Centre. The PIC From PIC To and Vendor Dec/Waybill No. can be loaded straight into the form if the fields PI1, PI2 and VEN were used as Data entry on Data entry readers.
Aleis ISO9060 Series Operational Manual Step 4 Click on the "Start" box On a successful or unsuccessful transfer you will get a message in the status box.
Aleis ISO9060 Series Operational Manual 9.5 3rd Party Transfer (Australia Only) This opens the NLIS Transfer Wizard, using the selected fields in the current session(s). This button is used for Third Party transfers with or without written permission. For further information please use the help feature in Aleis DataLink 3rd Party Transfer Steps Step 1 Click on the "3rd Party Transfer" button.
Aleis ISO9060 Series Operational Manual Step 3 After completing the form Click on "Next" If you choose to tick the Upload Later box the Transfer will not be completed but you can complete the transfer at any time by resuming the upload from the Upload Centre. The PIC From PIC To and Vendor Dec/Waybill No. can be loaded straight into the form if the fields PI1, PI2 and VEN were used as Data entry on Data entry readers.
Aleis ISO9060 Series Operational Manual Step 4 Click on "Yes" You have to accept this agreement to finish the transaction You will then be presented with the following Box Step 5 Click on the "Start" Box On a successful or unsuccessful transfer you will get a message in the status box.
Aleis ISO9060 Series Operational Manual 9.6 Retrieve Tag Bucket (Australia Only) This opens the NLIS Transfer Wizard, to retrieve all RFID and NLIS ID tag numbers that match a specific PIC from the NLIS database. You can also retrieve the Lifetime Traceability (LT), EU Status (EU), Last Transfer Date (TFR) and the Issue Date (ISS) For further information please use the help feature in Aleis DataLink Retrieve Tag Bucket Steps Step 1 Click on the "Retrieve Tag Bucket" button.
Aleis ISO9060 Series Operational Manual Step 2 After completing the form Click on "Next" You will then be presented with the following Box Step 3 Click on "Start" The Tag Bucket will be loaded into the main screen of DataLink.
Aleis ISO9060 Series Operational Manual 9.7 Tag Replacement (Australia Only) This opens the NLIS Tag Replacement Request form using the selected tags in the current session. This button is used for replacing defective RFID tags. For further information please use the help feature in Aleis DataLink Tag Replacement Steps Step 1 Click on the "Tag Replacement" button.
Aleis ISO9060 Series Operational Manual Step 2 Type in the Replacement tag and the Broken tag in the boxes below Step 3 Click on the "Add Request" Box and the tags will be inserted into the box below.
Aleis ISO9060 Series Operational Manual You will be presented with the following Box Step 5 After completing the form Click on "Next" You will be presented with the following Box Step 6 Click on "Start" On a successful or unsuccessful tag replacement you will get a message in the status box Aleis ISO9060 Series Page 38 of 43
Aleis ISO9060 Series Operational Manual 9.8 LIS Upload Centre (Australia Only) This opens the Upload Centre screen, which displays all transactions with the NLIS database. Both successful and unsuccessful transactions are displayed and information regarding the transaction.
Aleis ISO9060 Series Operational Manual 10.0 Rail Measurements for Fixed Race System Antenna Mounting Measurements Bottom of Antenna to be mounted 300 mm from ground where animal actually stands. Antenna bolt hole spacings are marked on diagram above. Holes are pre-drilled in antenna. DO NOT DRILL HOLES IN ANTENNA YOURSELF. Aleis ISO9060 Series 10.10.
Aleis ISO9060 Series Operational Manual 11.0 Aleis Conditions of Sale In these conditions: (1) `Vendor' means Aleis Pty Ltd ACN 130 754 826 of the Cnr Old Rosevale & Jandowae/Kingaroy Rds, Jandowae, Queensland, 4410 which is the seller of the goods (2) ‘Factory’ means the Vendor’s principal place of business at the Cnr Old Rosevale & Jandowae /Kingaroy Rds, Jandowae, Queensland 4410. (3) Purchaser' means the customer(s) described overleaf which is the purchaser of the goods.
Aleis ISO9060 Series Operational Manual 12. (3) Vendor shall not be liable for and purchaser releases vendor from any claims in respect of faulty or defective design of any goods supplied unless such design has been wholly prepared by vendor and the responsibility for any claim has been specifically accepted by vendor in writing and in any event vendor's liability hereunder shall be strictly limited to the replacement of defective parts in accordance with para 11(1) of these conditions.
Aleis ISO9060 Series Operational Manual 24. If the Vendor has not paid for any goods on the due date specified in this Agreement, without prejudice to any other right or remedy, all outstanding money shall bear interest on daily balances until paid at the rate of 1.5% per month and such money together with all interest shall be recoverable forthwith from the Purchaser.