Document Title 700MHz TRDU B12 User Manual PAGE: 1 DATE: 11-30-2012 NOTE: APPROVAL ON THIS PAGE SIGNIFIES THE ENTIRE DOCUMENT APPROVED. 700MHZ B12 TRDU USER MANUAL 1.0 DCP-xxxxxx 11-30-2012 Initial Release D. Fisher REV DCO NO. DATE CHANGE INFORMATION AUTHOR DOCUMENT NO.: 43-G07CRH-48-01B-U-00016 PAGE NO.
Document Title 700MHz TRDU B12 User Manual 1.0 Initial release 11-30-2012 REVISION HISTORY DOCUMENT NO.: 43-G07CRH-48-01B-U-00016 TITLE:700MHz TRDU B12 User Manual PAGE: 2 DATE: 11-30-2012 D.
Document Title 700MHz TRDU B12 User Manual PAGE: 3 DATE: 11-30-2012 Table of Contents 1.0 Introduction ...................................................................................................................................................................................... 4 2.0 System Specifications ......................................................................................................................................................................... 5 4.0 Interfaces .......
Document Title 700MHz TRDU B12 User Manual PAGE: 4 DATE: 11-30-2012 1.0 Introduction MTI’s G07CRH-48-01B is a 2x67W LTE TRDU which has two RF transmitters, two receivers and double duplexer filter. It is packaged in a single shelf-mounted module and is deployed in CPRI-compliant basestation networks.
Document Title 700MHz TRDU B12 User Manual 2.0 System Specifications Table 1: MECHANICAL/ENVIRONMENTAL SPECIFICATIONS PARAMETER TARGET SPECIFICATIONS Unit Dimensions 360.0 mm by 367.0 mm by110.0 mm=14.53 liter Unit Weight 14.5 Kg DC Power in -37V to -57VV (Nominal -48Vdc) Operational Temperature Range -40°C to +55°C Storage/Transportation Temperature Range -55ºC to +70ºC Enclosure Class IP20 Safety and Grounding EN 60950-1, IEC 60950, UL 60950-1 Storage ETSI EN 300 019-1-1 class 1.
Document Title PAGE: 7 DATE: 11-30-2012 700MHz TRDU B12 User Manual 4.0 Interfaces 4.
Document Title PAGE: 8 DATE: 11-30-2012 700MHz TRDU B12 User Manual 4.1.4 DC Power Connector DC Power Connector: Mini Fit Junior PIN # PIN Name 1 2 +24V +24V RTN Function +24V DC supply input +24V DC supply return 4.1.5 AISG Connector 8-pin AISG PIN # Max Current Capability Designation 1 +12 V DC Nominal 2 not used 3 RS485 B 4 RS485 GND 5 RS485 A 6 +24V Nominal 7 DC Return 8 N/C 1.0 A Current Clamp 1.
Document Title 700MHz TRDU B12 User Manual 5.
Document Title 700MHz TRDU B12 User Manual 6.0 Photographs 6.
Document Title 700MHz TRDU B12 User Manual 6.
Document Title 700MHz TRDU B12 User Manual 6.
DRAFT Product conformance statements Page - 14 United States .................................................................................................................................................................................................................................... Indoor applications This equipment is intended for installation in restricted access locations where access is controlled or where access can only be gained by service personnel with a key or tool.
Product Conformance Statements - United States Introduction The statements that follow are the product conformance statements that apply to the 9412 eNodeB when deployed in the United States. Federal Communications Commission . FCC Part 15 This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.
DRAFT • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help. FCC Part 68 This Part does not applicable Technical Support Services, within the United States: +1 630 224 4762, prompt 2 RF approval This equipment complies with Part 2, Subpart J - Equipment Authorization Procedures, of the FCC Rules.