R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners. The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein. © 2017 Nokia.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Preface 1 Preface This preface provides general information about the documentation set for optical network terminals (ONTs). 1.1 Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release. 1.
R05.07.00 | September 2017 | Edition 02 Preface 7368 ISAM ONT G-240W-F Product Guide 1.6 Nokia quality processes Nokia’s ONT quality practices are in compliance with TL 9000 requirements. These requirements are documented in the Fixed Networks Quality Manual 3FQ-30146-6000-QRZZA. The quality practices adequately ensure that technical requirements and customer end-point requirements are met.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Procedure 2 Preface To access individual documents Individual PDFs of customer documents are also accessible through the Nokia Customer Support website. 1 Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. 2 From the Technical Content for drop-down menu, choose the product.
R05.07.00 | September 2017 | Edition 02 Preface 7368 ISAM ONT G-240W-F Product Guide 1.9.1 Procedures with options or substeps When there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals. Procedure 3 Example of options in a procedure At step 1, you can choose option a or b. At step 2, you must do what the step indicates. 1 2 Procedure 4 This step offers two options.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 1.10 Preface Multiple PDF document search You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a common term. Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file. Note — The PDF files in which you search must be in the same folder.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Table of contents 1 Preface ........................................................................................... 3 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.9.1 1.10 Scope....................................................................................................... 3 Audience .................................................................................................. 3 Required knowledge .....................
R05.07.00 | September 2017 | Edition 02 3.3 Other environmental requirements.......................................................... 30 7368 ISAM ONT G-240W-F Product Guide Issue: 01 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 ONT environmental requirements ........................................................... 30 Storage .................................................................................................. 30 Transportation .............................................................
R05.07.00 | September 2017 | Edition 02 5.11 5.11.1 G-240W-F special considerations ........................................................... 61 Wi-Fi service........................................................................................... 61 7368 ISAM ONT G-240W-F Product Guide Issue: 01 5.11.1.1 5.11.1.2 5.11.1.3 5.11.2 Wi-Fi physical features............................................................................ 62 Wi-Fi standards and certifications ................................
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 7368 ISAM ONT G-240W-F Product Guide List of figures 2 ETSI ONT safety guidelines ........................................................ 17 Figure 1 Figure 2 Figure 3 Figure 4 PSE certification ..................................................................................... 19 Laser product label ................................................................................. 22 Laser classification label .............
R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide List of tables 2 ETSI ONT safety guidelines ........................................................ 17 Table 1 Safety labels ........................................................................................... 18 4 ANSI ONT safety guidelines ........................................................ 33 Table 2 Safety labels ...........................................................................................
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 16 Table 38 Table 39 Table 40 Table 41 Table 42 Table 43 Table 44 Table 45 Table 46 Table 47 Table 48 Table 49 Table 50 Table 51 Table 52 Table 53 Access control parameters.................................................................... 118 Port forwarding parameters................................................................... 120 Port triggering parameters .............................................................
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ETSI ONT safety guidelines 2 ETSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals (ONTs). 2.1 Safety instructions This section describes the safety instructions that are provided in the ONT customer documentation and on the equipment. 2.1.
R05.07.00 | September 2017 | Edition 02 ETSI ONT safety guidelines 7368 ISAM ONT G-240W-F Product Guide The following is an example of the Caution box. Caution 1 — Possibility of service interruption. Caution 2 — Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 1 ETSI ONT safety guidelines PSE certification Warning This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. 19841 2.
R05.07.00 | September 2017 | Edition 02 ETSI ONT safety guidelines 2.2.3 7368 ISAM ONT G-240W-F Product Guide Environmental standard compliance The ONT equipment complies with the EN 300 019 European environmental standards. 2.2.4 Laser product standard compliance For most ONTs, the ONT equipment complies with EN 60825-1 and IEC 60825-2 for laser products.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 2.3.1 ETSI ONT safety guidelines Power supplies The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use greatly increases the danger of damage to equipment or property. 2.3.
R05.07.00 | September 2017 | Edition 02 ETSI ONT safety guidelines 7368 ISAM ONT G-240W-F Product Guide Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system. Danger — There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam. Observe the following danger for laser hazard.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ETSI ONT safety guidelines Laser classification label Figure 3 CLASS 1 LASER PRODUCT PRODUCTO LASER CLASE 1 CLASE 1 DEL LASER LASER CLASSE 1 18992 Figure 4 shows a laser warning label and an explanatory label for laser products. Labels and warning may be provided in other languages.
R05.07.00 | September 2017 | Edition 02 ETSI ONT safety guidelines Figure 4 7368 ISAM ONT G-240W-F Product Guide Laser warning labels INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Wavelength(s): xxxx nm Normal output power: xx m W Max output power: yyy m W Laser Warning Label Laser Warning Label CLASS 1 LASER PRODUCT RAYONNEMENT LASER CLASSE 1 RAYONNEMENT LASER INVISIBLE EVITER TOUTE EXPOSITION AU FAISCEAU NE PAS DEMONTER.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 2.5.4 ETSI ONT safety guidelines Location class Use cable supports and guides to protect the receptacles from strain. 2.6 Environmental requirements See the ONT technical specification documentation for more information about temperature ranges. During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ETSI environmental and CRoHS guidelines 3 ETSI environmental and CRoHS guidelines This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of the optical line termination (OLT) and optical network termination (ONT) systems. This chapter also includes environmental operation parameters of general interest. 3.
R05.07.00 | September 2017 | Edition 02 ETSI environmental and CRoHS guidelines Figure 5 7368 ISAM ONT G-240W-F Product Guide Products below MCV value label 18986 3.1.2.2 Products containing hazardous substances above Maximum Concentration Value (MCV) label Figure 6 shows the label that indicates a product is above the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products).
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 6 ETSI environmental and CRoHS guidelines Products above MCV value label 18985 Together with major international telecommunications equipment companies, Nokia has determined it is appropriate to use an EFUP of 50 years for network infrastructure equipment and an EFUP of 20 years for handsets and accessories.
R05.07.00 | September 2017 | Edition 02 ETSI environmental and CRoHS guidelines 7368 ISAM ONT G-240W-F Product Guide 3.3 Other environmental requirements Observe the following environmental requirements when handling the P-OLT or ONT equipment. 3.3.1 ONT environmental requirements See the ONT technical specification documentation for more information about temperature ranges. 3.3.2 Storage According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in Class 1.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 3.3.6 ETSI environmental and CRoHS guidelines Material content compliance European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium, and certain flame retardants in electrical and electronic equipment.
R05.07.00 | September 2017 | Edition 02 ETSI environmental and CRoHS guidelines 7368 ISAM ONT G-240W-F Product Guide At the end of their life, the OLT and ONT products are subject to the applicable local legislations that implement the European Directive 2012/19EU on waste electrical and electronic equipment (WEEE). There can be different requirements for collection and treatment in different member states of the European Union.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ANSI ONT safety guidelines 4 ANSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals or units (ONTs or ONUs) in the North American or ANSI market. 4.1 Safety instructions This section describes the safety instructions that are provided in the ONT customer documentation and on the equipment. 4.1.
R05.07.00 | September 2017 | Edition 02 ANSI ONT safety guidelines 7368 ISAM ONT G-240W-F Product Guide The following is an example of the Caution box. Caution 1 — Possibility of service interruption. Caution 2 — Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ANSI ONT safety guidelines Description Label text Operation conditions This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
R05.07.00 | September 2017 | Edition 02 ANSI ONT safety guidelines 4.2.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 4.2.
R05.07.00 | September 2017 | Edition 02 ANSI ONT safety guidelines 4.2.5 7368 ISAM ONT G-240W-F Product Guide Resistibility requirements compliance The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to overvoltage and overcurrents. 4.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 10 ANSI ONT safety guidelines Laser product label 18455 Figure 11 shows a laser classification label. Laser classification labels may be provided in other languages. Figure 11 Laser classification label CLASS 1 LASER PRODUCT PRODUCTO LASER CLASE 1 CLASE 1 DEL LASER LASER CLASSE 1 18992 Figure 12 shows a laser warning label and an explanatory label for laser products.
R05.07.00 | September 2017 | Edition 02 ANSI ONT safety guidelines Figure 12 7368 ISAM ONT G-240W-F Product Guide Laser warning labels INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Wavelength(s): xxxx nm Normal output power: xx m W Max output power: yyy m W Laser Warning Label Laser Warning Label CLASS 1 LASER PRODUCT RAYONNEMENT LASER CLASSE 1 RAYONNEMENT LASER INVISIBLE EVITER TOUTE EXPOSITION AU FAISCEAU NE PAS DEMONTER.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 13 ANSI ONT safety guidelines Sample laser product safety label on the ONT equipment Model: MFG: MONTH: XX YEAR: XXXX ICS: XX MRev: XX 3FE55851ABAA MAC:XXXXXXXXXXXX SN:ALCLXXXXXXXX I.T.E FCC ID: XXXXXXXXXXX 12VDC 3A ASSEMBLED IN CHINA 2301 Sugar Bush Rd. Raleigh, NC 27612 CLASS 1 LASER PRODUCT PRODUIT LASER DE CLASSE 1 Intertek 4006119 This device complies with Part 15 of the FCC Rule.
R05.07.00 | September 2017 | Edition 02 ANSI ONT safety guidelines 7368 ISAM ONT G-240W-F Product Guide 4.4 Electrical safety guidelines This section provides the electrical safety guidelines for the ONT equipment. Note — The ONTs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards. 4.4.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ANSI ONT safety guidelines During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD. Nokia recommends that you prepare the site before you install the ONT equipment. In addition, you must control relative humidity, use static dissipating material for furniture or flooring, and restrict the use of air conditioning. 4.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide G-240W-F unit data sheet 5 G-240W-F unit data sheet 5.1 G-240W-F part numbers and identification 5.2 G-240W-F general description 5.3 G-240W-F software and installation feature support 5.4 G-240W-F interfaces and interface capacity 5.5 G-240W-F LEDs 5.6 G-240W-F detailed specifications 5.7 G-240W-F GEM ports and T-CONTs 5.8 G-240W-F performance monitoring statistics 5.9 G-240W-F functional blocks 5.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 3FE 46649 AA 3FE 46597 AC G-240W-F unit data sheet Package S GPON indoor ONT with two POTS ports, four 10/100/1000 Base-T Ethernet interfaces, and one 100 mW Wi-Fi radio with on/off switch. — — — This ONT features two USB 2.0 ports and supports SC/APC optics. Includes two 5dBI indoor multi-directional external WiFi antenna (not detachable), one 1.5m CAT-5E Ethernet cable with RJ-45 endpoint, and one 1.5m RJ-11 cable.
R05.07.00 | September 2017 | Edition 02 G-240W-F unit data sheet 7368 ISAM ONT G-240W-F Product Guide Ordering kit part number Provisioning part number Description CLEI CPR ECI/ Bar code 3FE 46649 AD Customer-specific 3FE 46597 AD Package S GPON indoor ONT with two POTS ports, four 10/100/1000 Base-T Ethernet interfaces, and one 100 mW Wi-Fi radio with on/off switch. — — — — — — — — — — — — This ONT features two USB 2.0 ports and supports SC/APC optics.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide G-240W-F unit data sheet Ordering kit part number Provisioning part number Description CLEI CPR ECI/ Bar code 3FE 46649 CA 3FE 46597 AA Package S GPON indoor ONT with two POTS ports, four 10/100/1000 Base-T Ethernet interfaces, and one 100 mW Wi-Fi radio with on/off switch. — — — — — — — — — This ONT features two USB 2.0 ports and supports SC/APC optics.
R05.07.00 | September 2017 | Edition 02 G-240W-F unit data sheet 7368 ISAM ONT G-240W-F Product Guide • • • • • • • • • • • • • • • • • 2 POTS connections 2 USB 2.0 ports; voltage rate: 5V, current rate: 500mA per port reset button LED indicators on/off button WLAN enable/disable button WPS enable/disable button UPnP IGD2.0 support 2.4 GHz wireless interface 2 5dBI indoor multi-directional external WiFi antenna (not detachable) MIMO support for up to 20 concurrent wireless connections 802.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide G-240W-F unit data sheet These are the same TR-069 object parameters that are supported in the GUI. For more information, see Tables 17 and 27 in the chapter “Configure a G-240W-F indoor ONT”. The ONT also supports TR-069 statistics and troubleshooting for LAN, WAN, and WiFi. 5.2.
R05.07.00 | September 2017 | Edition 02 G-240W-F unit data sheet 7368 ISAM ONT G-240W-F Product Guide The BRG supports the encapsulation of Ethernet frames from different bridges in the GRE tunnel to the access tunnel. Multiple bridges can map to the same GRE tunnel. Where encapsulated packets exceed the MTU (packet size), fragmentation is also supported. Upstream QoS can reserve bandwidth for public and private Wi-Fi bridges, based on profiles defined for the access uplink speed.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide G-240W-F indoor ONT interface connection capacity Table 4 ONT type and model G-240W-F G-240W-F unit data sheet Maximum capacity POTS 10/ 100 BASE-T 10/ 100/ 1000 BASE-T RF video (CATV) MoCA VDSL2 E1/T1 Local craft GPON SC/APC 2 — 4 — — — — — 1 (1) Note (1) The G-240W-F ONTs provide Wi-Fi service that is enabled and disabled using a Wi-Fi on/off switch. 5.4.
R05.07.00 | September 2017 | Edition 02 G-240W-F unit data sheet 7368 ISAM ONT G-240W-F Product Guide G-240W-F ONT Reset, LED, WLAN, and WPS buttons and fiber optic connection (bottom and side view) Figure 15 Connections (back) Antenna Antenna US B 1 US B 2 LA N 1 LA N 2 LA N 3 LA N 4 TE L 1 TE L 2 POWER ON/OFF Fiber raceway RE S E T LE D WLA N ON/OFF buttons (side) WP S Fiber optic port LEDs (front) 26032 Table 5 describes the physical connections for G-240W-F indoor ONTs.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide G-240W-F unit data sheet Connection (1) Description WPS The Wi-Fi Protected Setup (WPS) button, located on the side of the ONT, enables and disables WLAN data encryption. (Wi-Fi security button) PON This connection, on the bottom of the ONT, is provided through an SC/APC fiber optic connector.
R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide G-240W-F unit data sheet Table 8 lists the power consumption specifications for G-240W-F indoor ONT. Table 8 G-240W-F indoor ONT power consumption specifications Maximum power (Not to exceed) Condition Minimum power Condition 13.6 W 2 POTS off-hook, 4 10/100/1000 Base-T Ethernet, Wi-Fi operational 3.
R05.07.
R05.07.
R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 18 G-240W-F unit data sheet G-240W-F ONT hardware block POTS ports Control processor SoC DSP SoC Bridge Ethernet MACs GPON MAC Ethernet ports GPON 19421 ONT SoC technology consists of five key elements: • GPON MAC • • • • Issue: 01 The Gigabit Passive Optical Network Media Access Control (GPON MAC) element on the SoC terminates the GPON interface using an optical diplexer.
R05.07.00 | September 2017 | Edition 02 G-240W-F unit data sheet 7368 ISAM ONT G-240W-F Product Guide These ONTs can also interact with additional hardware components to support functionality not provided by the SoC technology. 5.10 G-240W-F standards compliance G-240W-F indoor ONTs are compliant with the following standards: • • • • • • • • • • • • • • • 802.1p QoS 802.1q VLANs 802.3 auto negotiation, flow control 802.11 b/g/n at 2.4 GHz Codec G.711 a/u, G.722, G.723, G.726, G.729 EN 300-328 v1.9.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 20 5.10.1 G-240W-F unit data sheet G-240W-F ONT safety label Energy-related products standby and off modes compliance Hereby, Nokia declares that the G-240W-F ONTs are in compliance with the essential requirements and other relevant provisions of Directive 2009/125/EC together with Commission Regulation (EC) No 1275/2008 and Commission Regulation (EC) No 801/2013.
R05.07.00 | September 2017 | Edition 02 G-240W-F unit data sheet 5.11.1.1 7368 ISAM ONT G-240W-F Product Guide Wi-Fi physical features G-240W-F indoor ONTs have the following physical features that assist in providing Wi-Fi service: • WLAN button for enabling and disabling Wi-Fi service • two external multi-directional antennae • Wi-Fi Protected Setup (WPS) push button for enabling and disabling wireless protective services 5.11.1.
R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Install a G-240W-F indoor ONT 6 Install a G-240W-F indoor ONT 6.1 Purpose 6.2 General 6.3 Prerequisites 6.4 Recommended tools 6.5 Safety information 6.6 Procedure 6.1 Purpose This chapter provides the steps to install a G-240W-F indoor ONT. 6.2 General The steps listed in this chapter describe mounting and cabling for G-240W-F indoor ONTs. 6.
R05.07.00 | September 2017 | Edition 02 Install a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide • drill and drill bits • paper clip 6.5 Safety information Read the following safety information before installing the unit. Danger 1 — Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Install a G-240W-F indoor ONT 6.6 Procedure Use this procedure to install a G-240W-F indoor ONT. 1 Place the indoor ONT unit: a On the flat surface, such as a desk or shelf; go to step 3. Note — The G-240W-F cannot be stacked with another ONT or with other equipment.
R05.07.00 | September 2017 | Edition 02 Install a G-240W-F indoor ONT iii 7368 ISAM ONT G-240W-F Product Guide Drill the two holes in the wall where the ONT will be mounted and then drive the mounting screws into the holes. The recommended length of mounting screw is 1.15 in. (3.8 cm). Do not drive the screw into the wall completely. Leave approximately 1/8 in. (6 mm) between the screw head and the wall surface.
R05.07.
R05.07.00 | September 2017 | Edition 02 Install a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 4 Connect the Ethernet cables to the RJ-45 ports; see Figure 22 for the location of the RJ-45 ports. 5 Route the POTS cables directly to the RJ-11 ports as per local practices. The POTS port to the left is labeled 1 for Line 1 while the port on the right is labeled 2 for Line 2, as shown in Figure 22.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 11 If used, enable the WPS. i Locate the WPS button on the side of the ONT; see Figure 23 for location of the WPS button. ii Press the WPS button to change the status of the WPS. 12 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. 13 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Replace a G-240W-F indoor ONT 7 Replace a G-240W-F indoor ONT 7.1 Purpose 7.2 General 7.3 Prerequisites 7.4 Recommended tools 7.5 Safety information 7.6 Procedure 7.1 Purpose This chapter provides the steps to replace G-240W-F indoor ONTs. 7.2 General The steps listed in this chapter describe mounting and cabling for G-240W-F indoor ONTs. 7.
R05.07.00 | September 2017 | Edition 02 Replace a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide • optical power meter • drill and drill bits 7.5 Safety information Read the following safety information before replacing the unit. Danger 1 — Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Replace a G-240W-F indoor ONT 7.6 Procedure Use this procedure to replace a G-240W-F indoor ONT. 1 Deactivate the ONT services at the P-OLT. If you are using the SLID feature, this step is not required. The ONT and the services can remain in service (IS). i Use the RTRV-ONT command to verify the ONT status and th associated services. Record the serial number or the SLID of the ONT displayed in the command output.
R05.07.00 | September 2017 | Edition 02 Replace a G-240W-F indoor ONT Figure 26 7368 ISAM ONT G-240W-F Product Guide G-240W-F indoor ONT connections (back view) Antenna USB ports (2) Antenna Ethernet ports (4) POTS ports (2) Power input On/off button 26031 76 4 Disconnect the POTS, Ethernet, and power cables from the ONT; see Figure 26 for the connector locations on the G-240W-F indoor ONT.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 27 Replace a G-240W-F indoor ONT G-240W-F indoor ONT fiber optic port (bottom view) Connections (back) Antenna Antenna US B 1 US B 2 LA N 1 LA N 2 LA N 3 LA N 4 TE L 1 TE L 2 POWER ON/OFF Fiber raceway RE S E T LE D WLA N ON/OFF buttons (side) WP S Fiber optic port LEDs (front) 26032 Danger — Fiber cables transmit invisible laser light.
R05.07.00 | September 2017 | Edition 02 Replace a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide The RJ-11 port to the left is labeled 1 for Line 1 while the port on the right is labeled 2 for Line 2. 9 If required, have approved service personnel who are trained to work with optic fiber clean the fiber optic connection. See the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide for more information about fiber optic handling, inspection, and cleaning.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 16 Replace a G-240W-F indoor ONT If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide for more information. Note — A new SLID or the old SLID may be used with the replacement ONT. If a new SLID is used, the new SLID must also be programmed at the P-OLT using TL1 or a network manager.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT 8 Configure a G-240W-F indoor ONT 8.1 General 8.2 HGU mode GUI configuration 8.3 SFU mode GUI configuration 8.4 Operator ID 8.1 General Please refer to the configuration information provided with your OLT for the software configuration procedure for a G-240W-F ONT. For HTTP configuration procedures, please refer to the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide. 8.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide The default gateway IP address is http://192.168.1.254. You can connect to this IP address using your web browser after connecting your PC to one of Ethernet ports of the ONT. The static IP address of your PC must be in the same subnet as the ONT. 2 Enter your username and password in the Log in window, as shown in Figure 28. The default user name is userAdmin.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT • optics module status • statistics • voice information Procedure 7 Device information retrieval 1 Select Status > Device Information from the top-level menu in the GPON Home Gateway window, as shown in Figure 29. Figure 29 Device Information window Table 16 describes the fields in the Device Information window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide Field Description Lot Number Production date of the ONT Device Running Time Amount of time the device has run since last reset in hours, minutes, and seconds (2 of 2) 2 Click Refresh to update the displayed information. 3 STOP. This procedure is complete.
R05.07.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 2 Click Refresh to update the displayed information. 3 STOP. This procedure is complete. Procedure 9 WAN status retrieval 1 Select Status > WAN Status from the top-level menu in the GPON Home Gateway window, as shown in Figure 31. Figure 31 WAN status window Table 18 describes the fields in the WAN status window.
R05.07.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Table 19 88 7368 ISAM ONT G-240W-F Product Guide WAN status IPv6 parameters Field Description WAN connection list Drop-down menu listing all WAN connections. The connection shown is the connection for which WAN status will be shown.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Procedure 11 Configure a G-240W-F indoor ONT Home networking information retrieval 1 Select Status > Home Networking from the top-level menu in the GPON Home Gateway window, as shown in Figure 33. Figure 33 Home networking information window Table 20 describes the fields in the Home networking window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 3 Click Refresh to update the displayed information. 4 STOP. This procedure is complete. Procedure 12 Optics module status retrieval 1 Select Status > Optics Module Status from the top-level menu in the GPON Home Gateway window, as shown in Figure 34. Figure 34 Optics module status window Table 21 describes the fields in the Optics module status window.
R05.07.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide If there are no WAN connections to display, the system displays a message to indicate that. 2 Procedure 14 STOP. This procedure is complete. Voice information retrieval 1 Select Status > Voice Information from the top-level menu in the GPON Home Gateway window, as shown in Figure 36. Figure 36 Voice Information window Table 22 describes the fields in the Voice Information window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description Register Status Registration status of the selected POTS port: registered or unregistered Register Error Code Error code for the unregistered POTS port Register Error Reason Error reason for the unregistered POTS port User Agent IP IP address of the user agent (2 of 2) Note (1) This field is only visible at the adminGPON level; it is not visible at the userAdmin level.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 15 7368 ISAM ONT G-240W-F Product Guide LAN networking configuration 1 Select Network > LAN from the top-level menu in the GPON Home Gateway window, as shown in Figure 37. Figure 37 LAN network window Table 23 describes the fields in the LAN network window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description Static DHCP MAC Address MAC address to associate to the LAN Static DHCP IPv4 Address IPv4 address to associate to the MAC address (2 of 2) Issue: 01 2 Select the mode for each port. 3 Click Save. 4 Enter the DHCP configuration information. 5 Click Save. 6 Bind a MAC address to the LAN by entering the MAC and IP addresses and then clicking Add.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 16 7368 ISAM ONT G-240W-F Product Guide LAN IPv6 networking configuration 1 Select Network > LAN_IPv6 from the top-level menu in the GPON Home Gateway window, as shown in Figure 38. Figure 38 LAN IPv6 network window Table 24 describes the fields in the LAN IPv6 network window. Table 24 LAN IPv6 network parameters Field Description DNS Server Choose a DNS server from the drop-down menu.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description Whether other info obtained through DHCP Select this checkbox to enable retrieval of other information through DHCP. Maximum interval for periodic RA messages Enter the maximum interval (in seconds) for periodic Router Advertisement messages. The interval range is from 4 to 1800.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 17 7368 ISAM ONT G-240W-F Product Guide WAN networking configuration 1 Select Network > WAN from the top-level menu in the GPON Home Gateway window, as shown in Figure 39. Figure 39 WAN network window Table 25 describes the fields in the WAN network window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description Manual DNS Enter a manual DNS (2 of 2) 2 Configure a specific WAN connection. 3 Click Save. 4 STOP. This procedure is complete. Procedure 18 WAN DHCP configuration 1 Select Network > WAN DHCP from the top-level menu in the GPON Home Gateway window, as shown in Figure 40. Figure 40 WAN DHCP window Table 26 describes the fields in the WAN DHCP window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Table 26 WAN DHCP parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu DHCP Option 50 persistent Select this checkbox to enable DHCP Option 50 persistent Enable DHCP Option 60 Select this checkbox to enable DHCP Option 60 (vendor class identifier) Enable DHCP Option 61 Select this checkbox to enable DHCP Option 61 (client identifier) 2 Configure a WAN DHCP option.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Table 27 describes the fields in the Wireless 2.4GHZ network window. Table 27 WiFi 2.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide Field Description WPA Key Enter the WPA key Enable WPS Enable or disable WPS from this drop-down menu (2 of 2) Notes (1) When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options are no longer available: WPA version, WPA encryption mode, WPA key, Enable WPS, WPS mode.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Procedure 20 Configure a G-240W-F indoor ONT Wireless scheduling 1 Select Network > Wireless Schedule from the top-level menu in the GPON Gateway window, as shown in Figure 42. Figure 42 Wireless Schedule window 2 Select the Schedule Function checkbox to turn the wireless signal off for the configured period. 3 Click the plus sign (+) to add a scheduling rule.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 8 Click Save Changes. 9 STOP. This procedure is complete. Procedure 21 IP Routing configuration 1 Select Network > IP Routing from the top-level menu in the GPON Home Gateway window, as shown in Figure 43. Figure 43 IP Routing network window Table 28 describes the fields in the IP Routing network window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description IPv4 Interface Choose a WAN connection previously created in the WAN network window from the drop-down menu Forwarding Policy Choose a forwarding policy from the drop-down menu (2 of 2) 2 Enter the routing information. 3 Click Add. 4 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Table 29 106 7368 ISAM ONT G-240W-F Product Guide DNS network parameters Field Description DNS Proxy Enabled Select the Enabled checkbox to enable DNS proxy Domain Name Enter the domain name IPv4 Address Enter the IPv4 address OriginalDomain Enter the original domain name New Domain Enter the new domain name 2 Select the Enabled checkbox and click Save to enable DNS proxy.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Procedure 23 Configure a G-240W-F indoor ONT TR-069 configuration 1 Select Network > TR-069 from the top-level menu in the GPON Home Gateway window, as shown in Figure 45. Figure 45 TR-069 network window Table 30 describes the fields in the TR-069 network window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 3 Click Save. 4 STOP. This procedure is complete. Procedure 24 QoS configuration 1 Select Network > QoS Config from the top-level menu in the Home Gateway window. Figure 46 shows the window for configuring QoS L2 (Layer 2 packet sizes). Figure 46 QoS Config window (L2) Table 31 describes the fields in the QoS Config window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description 802.1p Mark Enter the value for the 802.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 25 7368 ISAM ONT G-240W-F Product Guide Firewall configuration 1 Select Security > Firewall from the top-level menu in the GPON Home Gateway window, as shown in Figure 47. Figure 47 Firewall window Firewall security applies only to services provided by the ONT. Internet access from the LAN side is not affected by this firewall. Three security levels are available: Low, Medium, and High.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Table 32 Configure a G-240W-F indoor ONT Firewall parameters Field Description Security level Choose the security level from the drop-down menu: low, medium, or high Attack Protect (Protection against DoS or DDoS attacks) Choose enable or disable attack protect from the drop-down menu The default is disable 2 Configure the firewall. 3 Click Save. 4 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Table 33 MAC filter parameters Field Description Enable MAC filter Select this checkbox to enable the MAC filter Mac Address Select a MAC address from the drop-down menu or enter the address in the text field Mac Filter Mode Choose the MAC filter mode from this drop-down menu: Blocked or Allowed 2 Click Refresh to update the information. 3 Configure a MAC filter. 4 Click Add. 5 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Table 34 describes the fields in the IP filter window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 28 7368 ISAM ONT G-240W-F Product Guide URL filter configuration 1 Select Security > URL Filter from the top-level menu in the GPON Home Gateway window, as shown in Figure 50. Figure 50 URL Filter window Table 35 describes the fields in the URL Filter window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT You can configure up to 100 URL filters. 5 STOP. This procedure is complete. Procedure 29 Parental control 1 Select Security > Parent Control from the top-level menu in the EPON Home Gateway window, as shown in Figure 51. Figure 51 Parental Control window Table 36 describes the fields in the Parental Control window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 2 Select the Access Control checkbox. 3 Click the plus sign (+) to add a policy. A separate panel displays for configuring the policy name, IP address of the device, and dates and times for the policy. 4 Configure the parental control policy. 5 Click Enable to activate the policy. 6 STOP. This procedure is complete.
R05.07.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 31 7368 ISAM ONT G-240W-F Product Guide Access control configuration This procedure describes how to configure the access control level (ACL). Note 1 — ACL takes precedence over the firewall policy. Note 2 — The trusted network object will be shared for all WAN connections; it is not applied individually to a WAN connection.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description Source IP End Enter an end IP address for the new subnet trusted network (2 of 2) 2 Select a WAN connection from the drop-down menu. 3 Click to enable or disable Trusted Network. 4 Select an access control level for each of the seven protocols for both the WAN and the LAN side. 5 Click Save. 6 Optionally, add one or more subnet trusted networks.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 32 7368 ISAM ONT G-240W-F Product Guide Port forwarding configuration 1 Select Application > Port forwarding from the top-level menu in the GPON Home Gateway window, as shown in Figure 54. Figure 54 Port forwarding window Table 39 describes the fields in the port forwarding window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT 3 Click Add. 4 STOP. This procedure is complete. Procedure 33 Port triggering 1 Select Application > Port Triggering from the top-level menu in the GPON Gateway window, as shown in Figure 55. Figure 55 Port Triggering window Table 40 describes the fields in the Port Triggering window.
R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Table 41 describes the fields in the DDNS window. Table 41 Field Description WAN Connection List Choose a WAN connection from the drop-down menu Enable DDNS Select this checkbox to enable DDNS on the chosen WAN connection ISP Choose an ISP from the drop-down menu. Domain Name Domain name Username Username Password Password 2 Configure the DDNS. 3 Click Save. 4 STOP.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 2 Select the Enable NTP Service checkbox to enable NTP service. 3 Click Save. 4 STOP. This procedure is complete. Procedure 36 USB configuration 1 Select Application > USB from the top-level menu in the Ethernet Gateway window, as shown in Figure 58. A USB printer that is connected to the ONT is available to all LAN devices.
R05.07.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 37 UPnP and DLNA configuration 1 Select Application > UPnP and DLNA from the top-level menu in the GPON Home Gateway window, as shown in Figure 59. Figure 59 126 7368 ISAM ONT G-240W-F Product Guide UPnP and DLNA window 2 Select the Enable UPnP/DLNA checkbox to enable UPnP and DLNA. 3 Click Save/Apply. 4 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Procedure 38 Configure a G-240W-F indoor ONT Voice setting 1 Select Application > Voice Setting from the top-level menu in the EPON Home Gateway window, as shown in Figure 60. Figure 60 Voice setting window Table 43 describes the fields in the Voice Setting window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide Field Description Line Choose a line from the drop-down menu Enable Choose Enabled or Disabled from the drop-down menu Directory Number Enter a directory number AuthUserName Enter an authorized user name AuthPassword Enter a password for the user URL Enter the URL (2 of 2) 2 Configure voice setting. 3 Click Save. 4 STOP. This procedure is complete. 8.2.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide • • Configure a G-240W-F indoor ONT the password must contain at least two types of characters: numbers, letters, or special characters the same character must not appear more than 8 times in a row When the password meets the password rules, the application displays the message “Your password has been changed successfully”.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Table 44 Password parameters Field Description New Password New password (must adhere to the password rules described above) Re-enter password Must match the new password entered above exactly Prompt message Password prompt message 2 Configure the new password. 3 Click Save. 4 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 2 Configure a G-240W-F indoor ONT Click Start to start the speed test. Enter the URL for the test server in the pop-up window. 3 Procedure 41 STOP. This procedure is complete. LOID configuration 1 Select Maintenance > LOID Config from the top-level menu in the GPON Home Gateway window, as shown in Figure 63. Figure 63 LOID Config window Table 45 describes the fields in the LOID configuration window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 2 Configure the LOID. 3 Click Save/Apply. 4 STOP. This procedure is complete. Procedure 42 SLID configuration 1 Select Maintenance > SLID Configuration from the top-level menu in the GPON Home Gateway window, as shown in Figure 64. Figure 64 SLID configuration window Table 46 describes the fields in the SLID configuration window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Field Description SLID Mode Choose a SLID mode from the drop-down menu: HEX or ASCII In ASCII mode, the maximum number of characters is 10, for example: abcdefg123. In HEX mode, the maximum number of characters is 20, for example: 1234567890ABCDEF1234 (2 of 2) 2 Configure the new SLID. 3 Click Save. 4 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Table 47 Device management parameters Field Description Host Name Choose a host from the drop-down menu Host Alias Enter an alias for the chosen host 2 Configure an alias for a specific host. 3 Click Add. 4 STOP. This procedure is complete. Procedure 44 Backup and restore 1 Select Maintenance > Backup and Restore from the top-level menu in the GPON Home Gateway window, as shown in Figure 66.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 3 Click Import Config File to restore the ONT to the saved backup or click Export Config File to export the current ONT configuration to the backup file. 4 STOP. This procedure is complete. Procedure 45 Upgrade firmware 1 Select Maintenance> Firmware Upgrade from the top-level menu in the GPON Home Gateway window, as shown in Figure 67.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 46 Reboot ONT 1 Select Maintenance > Reboot Device from the top-level menu in the GPON Home Gateway window, as shown in Figure 68. Figure 68 136 7368 ISAM ONT G-240W-F Product Guide Reboot window 2 Click Reboot to reboot the ONT. 3 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Procedure 47 Restore factory defaults 1 Select Maintenance > Factory Default from the top-level menu in the GPON Home Gateway window, as shown in Figure 69. Figure 69 Issue: 01 Configure a G-240W-F indoor ONT Factory default window 2 Click Factory Default to reset the ONT to its factory default settings. 3 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 48 7368 ISAM ONT G-240W-F Product Guide Diagnose WAN connections 1 Select Maintenance > Diagnostics from the top-level menu in the GPON Home Gateway window, as shown in Figure 70. Figure 70 Diagnostics window 2 Choose a WAN connection to diagnose from the drop-down menu. 3 Enter the IP address or domain name. 4 Select the test type: ping, traceroute, or both.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide 9 Click Cancel to cancel the test. 10 STOP. This procedure is complete. Procedure 49 View log files 1 Select Maintenance > Log from the top-level menu in the GPON Home Gateway window, as shown in Figure 71.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 3 7368 ISAM ONT G-240W-F Product Guide Choose a reading level from the drop-down menu to determine which types of events to display from the log file: • • • • • • • • Emergency Alert Critical Error Warning Notice Informational Debug 4 The log file is displayed in the bottom panel of the window. 5 STOP. This procedure is complete. 8.2.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Figure 72 Configure a G-240W-F indoor ONT RG Troubleshooting Counters window Table 48 describes the fields in the RG Troubleshooting Counters window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 2 Configure the test times if desired. 3 Click Refresh to update the data. 4 STOP. This procedure is complete. 8.3 SFU mode GUI configuration Use the procedures below to use the web-based GUI for the G-240W-F in SFU mode. SFU customer premise devices are designed for single indoor residential applications.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT Web login window Figure 73 Caution — Pressing the Reset button for less than 10 seconds reboots the ONT; pressing the Reset button for 10 seconds resets the ONT to the factory defaults, except for the LOID and SLID. Note — If you forget the current username and password, press the reset button for 10 s and the default values for the username and password will be recovered at startup. 8.3.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT Procedure 52 7368 ISAM ONT G-240W-F Product Guide Device information retrieval 1 Select Status > Device Information from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 74. Figure 74 Device Information window Table 49 describes the fields in the Device Information window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT 2 Click Refresh to update the displayed information. 3 STOP. This procedure is complete. Procedure 53 Optics module status retrieval 1 Select Status > Optics Module Status from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 75. Figure 75 Optics module status window Table 50 describes the fields in the Optics module status window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide Field Description Lower (ONT ANI-ONT-Side Optical Measurements-Optical Threshold) Lower optical threshold, measured in dBm Upper (ONT ANI-ONT-Side Optical Measurements-Optical Threshold) Lower optical threshold, measured in dBm (2 of 2) 2 Click Refresh to update the displayed information. 3 STOP. This procedure is complete. 8.3.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT A separate panel displays for configuring wireless schedule rules. 4 Enter a start time and end time for the period in which you want the wireless signal off. 5 Choose Everyday or Individual Days from the drop-down menu. 6 If you chose Individual Days, select the checkboxes for the desired days. The Recurrence Pattern shows the rules created to date. 8.3.
R05.07.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT 3 Click Save. 4 STOP. This procedure is complete. Procedure 56 LOID configuration 1 Select Maintenance> LOID Config from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 78. Figure 78 LOID Authentication window Table 52 describes the fields in the LOID configuration window.
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 7368 ISAM ONT G-240W-F Product Guide 4 Click Save/Apply. 5 STOP. This procedure is complete. Procedure 57 SLID configuration 1 Select Maintenance > SLID Configuration from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 79. Figure 79 SLID configuration window Table 53 describes the fields in the SLID configuration window.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide Configure a G-240W-F indoor ONT 3 Click Save. 4 STOP. This procedure is complete. 8.4 Operator ID Use the procedure below to modify the operator ID for the G-240W-F. Procedure 58 Modifying the operator ID 1 Register the ONT with the OLT. 2 Check the original OPID. 3 Update the OntConfig.xml file by adding-the following content:
R05.07.00 | September 2017 | Edition 02 Configure a G-240W-F indoor ONT 8 7368 ISAM ONT G-240W-F Product Guide Use a TL1 command to disable further downloads: ED-ONT::ONT-1/1/3/1/19:::DLSW=DISABLED::IS; 9 152 STOP. This procedure is complete.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ONT configuration file over OMCI 9 ONT configuration file over OMCI 9.1 Purpose 9.2 Supported configuration file types 9.3 ONT configuration file over OMCI 9.1 Purpose This procedure describes how to use configuration files over OMCI to configure ONTs.
R05.07.00 | September 2017 | Edition 02 ONT configuration file over OMCI Table 54 7368 ISAM ONT G-240W-F Product Guide Supported configuration files File Index Description Details Supported ONTs/DPU PRE ONT pre-configuration file The XML-based PRECONFIG file controls the working mechanics of the ONT for various services. The default behavior of different ONTs may vary based on the factory settings.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ONT configuration file over OMCI File Index Description Details Supported ONTs/DPU GFT G.fast-related configuration file This text-based json script file controls the default behavior of the G.Fast ONT. HGU ONTs: G-240G-C,G-240W-F, G-240W-B, G-240W-C I-240W-A This file includes the provisioning parameters of the G.fast transports layer; it does not include VLAN or QoS provisioning.
R05.07.00 | September 2017 | Edition 02 ONT configuration file over OMCI Procedure 59 7368 ISAM ONT G-240W-F Product Guide Configuring an ONT using a configuration file via OMCI 1 Generate the TAR file to be uploaded to the OLT. Using the raw configuration file(s) provided by Nokia, generate the TAR file as follows: i On a Linux platform, rename the raw configuration file to adhere to the naming convention, as described in section 9.2.
R05.07.00 | September 2017 | Edition 02 7368 ISAM ONT G-240W-F Product Guide ONT configuration file over OMCI FILENAME2 will be downloaded and FILENAME2 will be made passive. An ONT reboot is not required. iv If pland-cfgfileX=FILENAME3 and dnload-cfgfileX= FILENAME 4, the OLT reports an error because the filenames are not the same.
R05.07.00 | September 2017 | Edition 02 FCC Regulations: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
R05.07.00 | September 2017 | Edition 02 Customer document and product support Customer documentation Customer Documentation Welcome Page Technical Support Customer Documentation Technical Support Documentation feedback Customer Documentation Feedback Copyright 2017 Nokia.