7368 Intelligent Services Access Manager CPE 7368 ISAM CPE A-240Z-A Product Guide 3FE-46615-AAAA-TCZZA Issue: 01 Nokia — Proprietary and confidential Use pursuant to applicable agreements
7368 ISAM CPE A-240Z-A Product Guide Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners. The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein. © 2017 Nokia.
7368 ISAM CPE A-240Z-A Product Guide Preface 1 Preface This preface provides general information about the documentation set for CPEs. 1.1 Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release. 1.
Preface 7368 ISAM CPE A-240Z-A Product Guide 1.6 Nokia quality processes Nokia’s CPE quality practices are in compliance with TL 9000 requirements. These requirements are documented in the Fixed Networks Quality Manual 3FQ-30146-6000-QRZZA. The quality practices adequately ensure that technical requirements and customer end-point requirements are met. The customer or its representatives may be allowed to perform on-site quality surveillance audits, as agreed upon during contract negotiations 1.
7368 ISAM CPE A-240Z-A Product Guide Procedure 2 Preface To access individual documents Individual PDFs of customer documents are also accessible through the Nokia Customer Support website. 1.9 1 Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. 2 From the Technical Content for drop-down menu, choose the product.
Preface 7368 ISAM CPE A-240Z-A Product Guide 1.9.1 Procedures with options or substeps When there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals. Procedure 3 Example of options in a procedure At step 1, you can choose option a or b. At step 2, you must do what the step indicates. 1 2 Procedure 4 This step offers two options. You must choose one of the following: a This is one option.
368 ISAM CPE A-240Z-A Product Guide 1.10 Preface Multiple PDF document search You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a common term. Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file. Note — The PDF files in which you search must be in the same folder. Procedure 5 To search multiple PDF files for a common term 1 Open Adobe Acrobat Reader.
Preface 8 7368 ISAM CPE A-240Z-A Product Guide 3FE-46615-AAAA-TCZZA Issue: 01
7368 ISAM CPE A-240Z-A Product Guide Table of contents 1 Preface................................................................................................. 3 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.9.1 1.10 Scope ..............................................................................................................3 Audience .........................................................................................................3 Required knowledge ............................................
7368 ISAM CPE A-240Z-A Product Guide 1 4 ANSI CPE safety guidelines ...........................................................29 4.1 4.1.1 4.1.2 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.3 4.3.1 4.3.2 4.3.3 4.4 4.5 Safety instructions ....................................................................................... 29 Safety instruction boxes in customer documentation ................................ 29 Safety-related labels ...................................................................................
7368 ISAM CPE A-240Z-A Product Guide Issue: 01 7.4 7.5 7.6 Recommended tools.................................................................................... 53 Safety information ........................................................................................ 54 Procedure .....................................................................................................54 8 Configure an A-240Z-A CPE ......................................................... 57 8.1 8.2 8.2.1 8.2.2 8.2.3 8.
7368 ISAM CPE A-240Z-A Product Guide 12 3FE-46615-AAAA-TCZZA Issue: 01
7368 ISAM CPE A-240Z-A Product Guide List of figures 2 ETSI CPE safety guidelines ............................................................17 Figure 1 PSE certification ......................................................................................... 19 3 ETSI environmental and CRoHS guidelines .................................23 Figure 2 Figure 3 Figure 4 Products below MCV value label ............................................................... 24 Products above MCV value label .....
7368 ISAM CPE A-240Z-A Product Guide Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 14 MAC filter window ........................................................................................ 92 IP filter window ..............................................................
7368 ISAM CPE A-240Z-A Product Guide List of tables Issue: 01 2 ETSI CPE safety guidelines ............................................................17 Table 1 Safety labels ................................................................................................ 18 4 ANSI CPE safety guidelines ............................................................29 Table 2 Safety labels ................................................................................................
7368 ISAM CPE A-240Z-A Product Guide Table 41 Table 42 Table 43 Table 44 Table 45 Table 46 Table 47 16 Password parameters................................................................................ 111 Device management parameters............................................................. 113 Dongle management parameters ............................................................ 115 RG Troubleshooting Counters parameters ..............................................
7368 ISAM CPE A-240Z-A Product Guide ETSI CPE safety guidelines 2 ETSI CPE safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of CPEs. 2.1 Safety instructions This section describes the safety instructions that are provided in the CPE customer documentation and on the equipment. 2.1.1 Safety instruction boxes The safety instruction boxes are provided in the CPE customer documentation.
ETSI CPE safety guidelines 7368 ISAM CPE A-240Z-A Product Guide The following is an example of the Caution box. Caution 1 — Possibility of service interruption. Caution 2 — Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box. Note — Information of special interest.
7368 ISAM CPE A-240Z-A Product Guide Figure 1 ETSI CPE safety guidelines PSE certification Warning This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. 19841 2.
ETSI CPE safety guidelines 2.2.3 7368 ISAM CPE A-240Z-A Product Guide Environmental standard compliance The CPE equipment complies with the EN 300 019 European environmental standards. 2.2.4 Resistibility requirements compliance The CPE equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to over voltage and overcurrents. 2.2.
7368 ISAM CPE A-240Z-A Product Guide 2.3.2 ETSI CPE safety guidelines Cabling The following are the guidelines regarding cables used for the CPE equipment: • All cables must be approved by the relevant national electrical code. • The cables for outdoor installation of CPEs must be suitable for outdoor use. • POTS wiring run outside the subscriber premises must comply with the requirements of local electrical codes. In some markets, the maximum allowed length of the outside run is 140 feet (43 m).
ETSI CPE safety guidelines 7368 ISAM CPE A-240Z-A Product Guide During operation in the supported temperature range, condensation inside the CPE caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Nokia recommends: • The door of the CPE not be opened until temperature inside and outside the enclosure has stabilized.
7368 ISAM CPE A-240Z-A Product Guide ETSI environmental and CRoHS guidelines 3 ETSI environmental and CRoHS guidelines This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of CPEs. This chapter also includes environmental operation parameters of general interest. 3.
ETSI environmental and CRoHS guidelines Figure 2 7368 ISAM CPE A-240Z-A Product Guide Products below MCV value label 18986 3.1.2.2 Products containing hazardous substances above Maximum Concentration Value (MCV) label Figure 3 shows the label that indicates a product is above the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products).
7368 ISAM CPE A-240Z-A Product Guide Figure 3 ETSI environmental and CRoHS guidelines Products above MCV value label 18985 Together with major international telecommunications equipment companies, Nokia has determined it is appropriate to use an EFUP of 50 years for network infrastructure equipment and an EFUP of 20 years for handsets and accessories.
ETSI environmental and CRoHS guidelines 3.3 7368 ISAM CPE A-240Z-A Product Guide Other environmental requirements Observe the following environmental requirements when handling the P-OLT or CPE equipment. 3.3.1 CPE environmental requirements See the CPE technical specification documentation for more information about temperature ranges. 3.3.2 Storage According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in Class 1.1, weather-protected, temperature-controlled locations. 3.3.
7368 ISAM CPE A-240Z-A Product Guide 3.3.6 ETSI environmental and CRoHS guidelines Material content compliance European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium, and certain flame retardants in electrical and electronic equipment.
ETSI environmental and CRoHS guidelines 7368 ISAM CPE A-240Z-A Product Guide At the end of their life, the OLT and CPE products are subject to the applicable local legislations that implement the European Directive 2012/19EU on waste electrical and electronic equipment (WEEE). There can be different requirements for collection and treatment in different member states of the European Union.
7368 ISAM CPE A-240Z-A Product Guide ANSI CPE safety guidelines 4 ANSI CPE safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of CPEs in the North American or ANSI market. 4.1 Safety instructions This section describes the safety instructions that are provided in the CPE customer documentation and on the equipment. 4.1.
ANSI CPE safety guidelines 7368 ISAM CPE A-240Z-A Product Guide The following is an example of the Caution box. Caution 1 — Possibility of service interruption. Caution 2 — Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box. Note — Information of special interest.
7368 ISAM CPE A-240Z-A Product Guide Figure 5 ANSI CPE safety guidelines Sample safety label on the CPE equipment Tested to Comply with FCC Standards FOR HOME OR OFFICE USE c ® COMMUNICATION SERVICE EQUIPMENT US LISTED 27FY Type 3R Enclosure - Rainproof This device complies with Part 15 of the FCC Rules.
ANSI CPE safety guidelines 7368 ISAM CPE A-240Z-A Product Guide This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
7368 ISAM CPE A-240Z-A Product Guide 4.3 ANSI CPE safety guidelines Electrical safety guidelines This section provides the electrical safety guidelines for the CPE equipment. Note — The CPEs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards. 4.3.1 Power supplies The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia.
ANSI CPE safety guidelines 7368 ISAM CPE A-240Z-A Product Guide During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD. Nokia recommends that you prepare the site before you install the CPE equipment. In addition, you must control relative humidity, use static dissipating material for furniture or flooring, and restrict the use of air conditioning. 4.
7368 ISAM CPE A-240Z-A Product Guide A-240Z-A unit data sheet 5 A-240Z-A unit data sheet Issue: 01 5.1 A-240Z-A part numbers and identification 5.2 A-240Z-A general description 5.3 A-240Z-A software and installation feature support 5.4 A-240Z-A interfaces and interface capacity 5.5 A-240Z-A LEDs 5.6 A-240Z-A detailed specifications 5.7 A-240Z-A functional blocks 5.8 A-240Z-A standards compliance 5.
A-240Z-A unit data sheet 5.1 7368 ISAM CPE A-240Z-A Product Guide A-240Z-A part numbers and identification Table 3 provides part numbers and identification information for the A-240Z-A CPE. Table 3 Identification of A-240Z-A CPEs Ordering part number Provisioning number Description CLEC CPR ECI/ Bar code 3FE 46615 AA 3FE 46615 AA CPE with 1 GE uplink, 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and 802.11ac 4x4 and 802.11n 2x2 WiFi radio with on/off switch. This CPE has 2 USB 2.
7368 ISAM CPE A-240Z-A Product Guide A-240Z-A unit data sheet Ordering part number Provisioning number Description CLEC CPR ECI/ Bar code 3FE 46614 DA 3FE 46615 AC CPE with 1 GE uplink, 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and 802.11ac 4x4 and 802.11n 2x2 WiFi radio with on/off switch. This CPE has 2 USB 2.0 ports. — — — This CPE has integrated ZigBee and Z-Wave (AUS band) chip sets for use in wireless home automation systems. Includes power supply with AUS plug.
A-240Z-A unit data sheet 7368 ISAM CPE A-240Z-A Product Guide Additional information about Smart Home configuration, including instructions for the Nokia Digital ONU mobile application, can be found by visiting: https://resources.nokia.com/asset/200375. The A-240Z-A is a compact CPE that can easily fit on a desk or shelf. For dimensions, see section 5.6. Figure 6 shows the A-240Z-A in its stand.
7368 ISAM CPE A-240Z-A Product Guide A-240Z-A unit data sheet • WPA2, WPA2-PSK/AES • support for multiple SSIDs (private and public instances); contact your Nokia • • • • • • • • • • • • • • • • 5.2.1 representative for further details. LED on/off button (on back of ONT) WPS LED buttons for 2.
A-240Z-A unit data sheet 5.2.3 7368 ISAM CPE A-240Z-A Product Guide TR-104 parameter extension support for voice service A proprietary attribute has been added to the TR-104 Voice Service object structure to enable the ACS to configure the name of the embedded GSIP XML file to be selected. The TR-104 Voice Service Object is: InternetGatewayDevice.Services.VoiceService.{i}.Capabilities.SIP. The proprietary attribute is: X_ALU-COM_XML_File_Name_Path. 5.
7368 ISAM CPE A-240Z-A Product Guide 5.4.1 A-240Z-A unit data sheet A-240Z-A connections and components Figure 7 shows the physical connections for A-240Z-A CPEs. Figure 7 A-240Z-A CPE physical connections ON/OFF TEL1 TEL2 WAN LAN1 LAN2 LAN3 LAN4 USB USB ON/OFF button TEL1 and TEL2 POTS ports (RJ-11) WAN port (RJ-45) LAN ports (4) (RJ-45) USB 2.
A-240Z-A unit data sheet 5.5 7368 ISAM CPE A-240Z-A Product Guide A-240Z-A LEDs Figure 8 shows the A-240Z-A CPE LEDs. Figure 8 A-240Z-A CPE LEDs Power POWER Internet INTERNET LAN 1 to 4 LAN1 LAN2 LAN3 LAN4 Tel1 Tel2 VoIP TEL1 TEL2 VOIP WPS WLAN WLAN 2.4G 2.4G 5G WPS 2.4G WLAN 2.4G WLAN 5G 26019 Table 7 provides LED descriptions for A-240Z-A CPEs.
7368 ISAM CPE A-240Z-A Product Guide A-240Z-A unit data sheet Indicator LED color and behavior LED behavior description TEL 1 to 2 Green solid Green flashing Off Telephone on POTS port has been provisioned and phone is off hook Telephone on POTS port is in ‘call in’ or ‘talking’ condition, or battery is low Telephone on POTS port is on hook, or battery missing or no power to CPE VOIP WPS 2.
A-240Z-A unit data sheet 7368 ISAM CPE A-240Z-A Product Guide Table 10 A-240Z-A CPE environmental specifications Mounting method Temperature range and humidity Altitude On desk or shelf Operating: 23F to 113F (-5C to 45C) ambient temperature 5% to 85% relative humidity, non-condensing Contact your Nokia technical support representative for more information Storage: -4F to 158F (-20C to 70C) 5.
7368 ISAM CPE A-240Z-A Product Guide 5.8 A-240Z-A unit data sheet A-240Z-A standards compliance A-240Z-A CPEs are compliant with the following standards: • • • • • IEEE 802.1D (QoS), 802.1p (bridging), 802.1q (VLAN) IEEE 802.3 (2012) (Ethernet standard) IEEE 802.11ac 4x4 (WiFi 5G) and 802.11b/g/n 2x2 (WiFi 2.4G) G.711, G.722, G.723, G.726, G.729 A, B (voice) ITU-T 1.552 for POTS ports Figure 10 shows the US safety label for the A-240Z-A CPE.
A-240Z-A unit data sheet Figure 12 7368 ISAM CPE A-240Z-A Product Guide A-240Z-A Australian (AU) safety label A-240Z-A Label location 5.8.1 Responsible party Table 11 lists the party in the US responsible for this CPE. Table 11 5.8.2 Responsible party contact information Legal Company name Nokia USA Inc. Address 2301 SUGAR BUSH RD.
7368 ISAM CPE A-240Z-A Product Guide A-240Z-A unit data sheet requirements and other relevant provisions of Directive 2009/125/EC together with Commission Regulation (EC) No 1275/2008 and Commission Regulation (EC) No 801/2013. The A-240Z-A CPES qualify as equipment with high network availability (HiNA) functionality. Since the main purpose of A-240Z-A CPEs is to provide network functionality with HiNA 7 days /24 hours, the modes Off/Standby, Power Management, and Networked Standby are inappropriate.
A-240Z-A unit data sheet 7368 ISAM CPE A-240Z-A Product Guide à 5 725 MHz doit être conforme à la limite de la p.i.r.e; iii. for devices with detachable antenna(s), the maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p.
7368 ISAM CPE A-240Z-A Product Guide 5.8.4 A-240Z-A unit data sheet FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
A-240Z-A unit data sheet 5.9.1 7368 ISAM CPE A-240Z-A Product Guide Wi-Fi service A-240Z-A CPEs feature Wi-Fi service as well as voice and data services. Wi-Fi is a wireless networking technology that uses radio waves to provide wireless HSI and network connections. This CPE complies with the IEEE 802.11 standards, which the Wi-Fi Alliance defines as the basis for Wi-Fi technology. 5.9.1.
7368 ISAM CPE A-240Z-A Product Guide Install an A-240Z-A CPE 6 Install an A-240Z-A CPE 6.1 Purpose 6.2 General 6.3 Prerequisites 6.4 Recommended tools 6.5 Safety information 6.6 Procedure 6.1 Purpose This chapter provides the steps to install an A-240Z-A CPE. 6.2 General The steps listed in this chapter describe mounting and cabling for an A-240Z-A CPE. 6.3 Prerequisites You need the following items before beginning the installation: • all required cables 6.
Install an A-240Z-A CPE 6.5 7368 ISAM CPE A-240Z-A Product Guide Safety information Read the following safety information before installing the unit. Danger 1 — Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits. Danger 2 — Make sure all sources of power are turned off and have no live voltages present on feed lines or terminals.
7368 ISAM CPE A-240Z-A Product Guide 6.6 Install an A-240Z-A CPE Procedure Use this procedure to install an A-240Z-A CPE. 1 Place the CPE unit on a flat surface, such as a desk or shelf. Note — The A-240Z-A cannot be stacked with another CPE or with other equipment.
Install an A-240Z-A CPE 7 7368 ISAM CPE A-240Z-A Product Guide If applicable, install the power supply according to manufacturer specifications. Note — Observe the following: • 8 Power up the CPE unit by using the power switch. 9 Verify the CPE LEDs and voltage status; see the 7368 Hardware and Cabling Installation Guide. 10 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide. 11 If necessary, reset the CPE.
7368 ISAM CPE A-240Z-A Product Guide Replace an A-240Z-A CPE 7 Replace an A-240Z-A CPE 7.1 Purpose 7.2 General 7.3 Prerequisites 7.4 Recommended tools 7.5 Safety information 7.6 Procedure 7.1 Purpose This chapter provides the steps to replace an A-240Z-A CPE. 7.2 General The steps listed in this chapter describe mounting and cabling for an A-240Z-A CPE. 7.3 Prerequisites You need the following items before beginning the installation: • all required cables 7.
Replace an A-240Z-A CPE 7.5 7368 ISAM CPE A-240Z-A Product Guide Safety information Read the following safety information before replacing the unit. Danger 1 — Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits. Danger 2 — Make sure all sources of power are turned off and have no live voltages present on feed lines or terminals.
7368 ISAM CPE A-240Z-A Product Guide Replace an A-240Z-A CPE RTRV-CPE::CPE-1-1-1-1-1; ii If the CPE is in service, place the CPE in OOS state. Example: ED-CPE::CPE-1-1-1-1-1; 2 Figure 14 Power down the unit by using the on/off power switch. See Figure 14 for the connections on the A-240Z-A CPE. A-240Z-A CPE connections ON/OFF TEL1 TEL2 WAN LAN1 LAN2 LAN3 LAN4 USB USB ON/OFF button TEL1 and TEL2 POTS ports (RJ-11) WAN port (RJ-45) LAN ports (4) (RJ-45) USB 2.
Replace an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide 9 Connect the power cable to the power connector. 10 If applicable, install the power supply according to manufacturer specifications. Note — Observe the following: • 11 Power up the unit by using the power switch. 12 Verify the CPE LEDs and voltage status; see the 7368 Hardware and Cabling Installation Guide. 13 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide. 14 If necessary, reset the CPE.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE 8 Configure an A-240Z-A CPE 8.1 General 8.2 GUI configuration 8.3 IOT application software package download 8.1 General Please refer to the configuration information provided with your OLT for the software configuration procedure for an A-240Z-A CPE. For HTTP configuration procedures, please refer to the 7368 ISAM CPE Configuration, Management, and Troubleshooting Guide. 8.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide The default user name is admin. The default password is a random number, which is included in the CPE kit. Figure 15 Web login window Caution — Pressing the Reset button for less than 10 seconds reboots the CPE; pressing the Reset button for 10 seconds resets the CPE to the factory defaults.
7368 ISAM CPE A-240Z-A Product Guide • • • • • • Procedure 7 Configure an A-240Z-A CPE WAN status WAN status IPv6 dongle status home networking information statistics voice information Device information retrieval 1 Select Status > Device Information from the top-level menu in the Ethernet Gateway window, as shown in Figure 16. Figure 16 Device Information window Table 13 describes the fields in the Device Information window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description Boot version Boot version of the CPE Software version Software version of the CPE Chipset Chipset of the CPE Lot Number Production date of the CPE Device Running Time Amount of time the device has run since last reset in hours, minutes, and seconds (2 of 2) 60 2 Click Refresh to update the displayed information. 3 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Procedure 8 Configure an A-240Z-A CPE LAN status retrieval 1 Select Status > LAN Status from the top-level menu in the Ethernet Gateway window, as shown in Figure 17. Figure 17 LAN status window Table 14 describes the fields in the LAN status window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description SSID Name Name of each SSID Wireless Encryption Status Encryption type used on the wireless connection Wireless Rx Packets Number of packets received on the wireless connection Wireless Tx Packets Number of packets transmitted on the wireless connection Wireless Rx Bytes Number of bytes received on the wireless connection Wireless Tx Bytes Number of bytes transmitted on the wireless connection Power Transmission
7368 ISAM CPE A-240Z-A Product Guide Procedure 9 Configure an A-240Z-A CPE WAN status retrieval 1 Select Status > WAN Status from the top-level menu in the Ethernet Gateway window, as shown in Figure 18. Figure 18 WAN status window Table 15 describes the fields in the WAN status window. Table 15 WAN status parameters Field Description WAN connection list Drop-down menu listing all WAN connections. The connection shown is the connection for which WAN status will be shown.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description WAN Link Status Whether the WAN link is up or down BRAS Connection Status Whether the BRAS is connected or disconnected IPv4 Address IPv4 address Netmask Netmask Gateway IPv4 gateway address Primary DNS Primary Domain Name Server Second DNS Secondary Domain Name Server Ethernet Link Status Whether the PON link is up or down Tx Packets Number of packets transmitted on the WAN connection Rx Packets Number o
7368 ISAM CPE A-240Z-A Product Guide Procedure 10 Configure an A-240Z-A CPE WAN status IPv6 retrieval 1 Select Status > WAN Status IPv6 from the top-level menu in the Ethernet Gateway window, as shown in Figure 19. Figure 19 WAN status IPv6 window Table 16 describes the fields in the WAN status IPv6 window. Table 16 WAN status IPv6 parameters Field Description WAN connection list Drop-down menu listing all WAN connections.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description Primary DNS Primary Domain Name Server Second DNS Secondary Domain Name Server Ethernet Link Status Whether the PON link is up or down Tx Packets Number of packets transmitted on the WAN connection Rx Packets Number of packets received on the WAN connection Tx Dropped Number of packets dropped on the transmit WAN connection Rx Dropped Number of packets dropped on the receive WAN connection Err Packets Number
7368 ISAM CPE A-240Z-A Product Guide Procedure 11 Configure an A-240Z-A CPE Dongle status retrieval 1 Select Status > Dongle Status from the top-level menu in the Ethernet Gateway window, as shown in Figure 20. Figure 20 Dongle Status window Table 17 describes the fields in the Dongle Status window.
Configure an A-240Z-A CPE Table 17 7368 ISAM CPE A-240Z-A Product Guide Dongle Status parameters Field Description USB Dongle Displays the USB dongle information: • USB Dongle Status • IMEI • Access Technology • Network in Use • SIM card Displays the SIM card information Status IMSI ICCID • • • • Statistics 68 RSSI (dBm) MSISDN Displays the number of bytes, sent and received, and the packet sent and received 2 Click Refresh to update the displayed information. 3 STOP.
7368 ISAM CPE A-240Z-A Product Guide Procedure 12 Configure an A-240Z-A CPE Home networking information retrieval 1 Select Status > Home Networking from the top-level menu in the Ethernet Gateway window, as shown in Figure 21. Figure 21 Home networking information window Table 18 describes the fields in the Home networking window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description Access Point Hexadecimal address of the wireless access point Local Devices Table entry Each entry indicates the status (active or inactive), connection type, device name, IP address, hardware address, and IP address allocation of each connected local device. (2 of 2) 2 Click Delete to delete a particular local device connection. 3 Click Refresh to update the displayed information. 4 STOP.
68 ISAM CPE A-240Z-A Product Guide Figure 22 2 Issue: 01 Configure an A-240Z-A CPE LAN ports statistics window STOP. This procedure is complete.
Configure an A-240Z-A CPE Procedure 14 7368 ISAM CPE A-240Z-A Product Guide Voice information retrieval 1 Select Status > Voice Information from the top-level menu in the Ethernet Gateway window, as shown in Figure 23. Figure 23 Voice Information window Table 19 describes the fields in the Voice Information window.
7368 ISAM CPE A-240Z-A Product Guide 2 Click Refresh to update the displayed information. 3 STOP. This procedure is complete. 8.2.3 Configure an A-240Z-A CPE Network configuration A-240Z-A CPEs also support network configuration, including: • • • • • • • • • • Issue: 01 LAN LAN IPv6 WAN WAN DHCP Wireless 2.
Configure an A-240Z-A CPE Procedure 15 7368 ISAM CPE A-240Z-A Product Guide LAN networking configuration 1 Select Network > LAN from the top-level menu in the Ethernet Gateway window, as shown in Figure 24. Figure 24 LAN network window Table 20 describes the fields in the LAN network window.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE Field Description Primary DNS Primary domain name server Secondary DNS Secondary domain name server Static DHCP MAC Address MAC address to associate to the LAN Static DHCP IP Address IP address to associate to the bound MAC address (2 of 2) Issue: 01 2 Configure the LAN. 3 Click Save. 4 Bind a MAC address to the LAN by entering the MAC and IP addresses in the Static DHCP Entry fields and then clicking Add.
Configure an A-240Z-A CPE Procedure 16 7368 ISAM CPE A-240Z-A Product Guide LAN IPv6 networking configuration 1 Select Network > LAN_IPv6 from the top-level menu in the Ethernet Gateway window, as shown in Figure 25. Figure 25 LAN IPv6 network window Table 21 describes the fields in the LAN IPv6 network window. Table 21 LAN IPv6 network parameters Field Description DNS Server Choose a DNS server from the drop-down menu.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE Field Description DHCP Start IP Address Enter the starting DHCP IP address. DHCP End IP Address Enter the ending DHCP IP address. Whether the address info through DCHP Select this checkbox to enable address information retrieval through DHCP. Whether other info obtained through DHCP Select this checkbox to enable retrieval of other information through DHCP.
Configure an A-240Z-A CPE Procedure 17 7368 ISAM CPE A-240Z-A Product Guide WAN networking configuration 1 Select Network > WAN from the top-level menu in the Ethernet Gateway window, as shown in Figure 26. Figure 26 WAN network window Table 22 describes the fields in the WAN network window.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE Field Description VLAN PRI Enter the VLAN PRI WAN IP Mode Choose an IP mode from the drop-down menu Manual DNS Enter a DNS (2 of 2) 2 Configure a specific WAN connection. 3 Click Save. 4 STOP. This procedure is complete. Procedure 18 WAN DHCP configuration 1 Select Network > WAN DHCP from the top-level menu in the Ethernet Gateway window, as shown in Figure 27.
Configure an A-240Z-A CPE Table 23 80 7368 ISAM CPE A-240Z-A Product Guide WAN DHCP parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu DHCP Option 50 persistent Select this checkbox to enable DHCP Option 50 Enable DHCP Option 60 Select this checkbox to enable DHCP Option 60 (vendor class identifier) Vendor Class Identifier 60 Enter the identifier for the vendor class Enable DHCP Option 61 Select this checkbox to enable DHCP Option 61 (client iden
7368 ISAM CPE A-240Z-A Product Guide Procedure 19 Configure an A-240Z-A CPE Wireless 2.4G networking configuration 1 Select Network > Wireless 2.4GHz from the top-level menu in the Ethernet Gateway window, as shown in Figure 28. Figure 28 Wireless 2.4GHz network window Table 24 describes the fields in the Wireless 2.4GHz network window. Table 24 Wireless 2.
Configure an A-240Z-A CPE Field Mode 7368 ISAM CPE A-240Z-A Product Guide Description Choose a Wi-Fi mode from the drop-down menu: auto (b/g/n) b g n • • • • • b/g Channel Choose a channel from the drop-down menu or choose Auto to have the channel automatically assigned Bandwidth Choose 20 MHz or 40 MHz from the drop-down menu.
7368 ISAM CPE A-240Z-A Product Guide 4 Click Save. 5 STOP. This procedure is complete. Procedure 20 Configure an A-240Z-A CPE Wireless 5G networking configuration 1 Select Network > Wireless 5GHz from the top-level menu in the Ethernet Gateway window, as shown in Figure 29. Figure 29 Wireless 5GHz network window Table 25 describes the fields in the Wireless 5GHZ network window.
Configure an A-240Z-A CPE Table 25 7368 ISAM CPE A-240Z-A Product Guide Wireless 5GHz network parameters Field Description Enable Select this checkbox to enable WiFi Bandwidth Choose from: 20 MHz 40 MHz • • • 80 MHz Channel Choose a channel from the drop-down menu or choose Auto to have the channel automatically assigned Transmitting Power Choose a percentage for the transmitting power from the drop-down menu: • Low (20%) • Medium (40%) • High (60%) • Maximum (100%) WMM Select this checkb
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE 2 Configure the Wireless connection. 3 If you have enabled and configured WPS, click WPS connect. 4 Click Save. 5 STOP. This procedure is complete. Procedure 21 Wireless scheduling 1 Select Network > Wireless Schedule from the top-level menu in the Ethernet Gateway window, as shown in Figure 30. Figure 30 Wireless Schedule window 2 Select the Schedule Function checkbox to turn the wireless signal off for the configured period.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide 4 Enter a start time and end time for the period in which you want the wireless signal off. 5 Choose Everyday or Individual Days from the drop-down menu. 6 If you chose Individual Days, select the checkboxes for the desired days. The Recurrence Pattern shows the rules created to date. 7 If desired, click the plus sign (+) to add more rules. 8 Click Save Changes. 9 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE Table 26 describes the fields in the Routing network window.
Configure an A-240Z-A CPE Procedure 23 7368 ISAM CPE A-240Z-A Product Guide DNS configuration 1 Select Network > DNS from the top-level menu in the Ethernet Gateway window, as shown in Figure 32. Figure 32 DNS network window Table 27 describes the fields in the DNS network window.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE 3 If required, associate an origin domain with a new domain, click Add. 4 STOP. This procedure is complete. Procedure 24 TR-069 configuration 1 Select Network > TR-069 from the top-level menu in the Ethernet Gateway window, as shown in Figure 33. Figure 33 TR-069 network window Table 28 describes the fields in the TR-069 network window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description Password Password used to log in to the CPE Connect Request Username Username used to log in to the auto-configuration server Connect Request Password Password used to log in to the auto-configuration server (2 of 2) 2 Configure TR-069 by entering the required information. 3 Click Save. 4 STOP. This procedure is complete. 8.2.
7368 ISAM CPE A-240Z-A Product Guide Procedure 25 Configure an A-240Z-A CPE Firewall configuration 1 Select Security > Firewall from the top-level menu in the Ethernet Gateway window, as shown in Figure 34. Figure 34 Firewall window Firewall security applies only to services provided by the CPE. Internet access from the LAN side is not affected by this firewall. Three security levels are available: Low, Medium, and High.
Configure an A-240Z-A CPE Table 29 7368 ISAM CPE A-240Z-A Product Guide Firewall parameters Field Description Security level Choose the security level from the drop-down menu: low, medium, or high Attack Protect (Protection against DoS or DDoS attacks) Choose enable or disable attack protect from the drop-down menu The default is disable 2 Configure the firewall. 3 Click Save. 4 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Table 30 MAC filter parameters Field Description Enable MAC filter Select this checkbox to enable the MAC filter MAC Address Select a MAC address from the drop-down menu or enter the address in the text field MAC Filter Mode Choose the MAC filter mode from this drop-down menu: Blocked or Allowed 2 Click Refresh to update the information. 3 Configure a MAC filter. 4 Click Add. 5 STOP. This procedure is complete.
Configure an A-240Z-A CPE Table 31 7368 ISAM CPE A-240Z-A Product Guide IP filter parameters Field Description Enable IP Filter Select this checkbox to enable an IP filter Mode Choose an IP filter mode from the drop-down menu: • Drop for upstream • Internal Client Choose an internal client from the drop-down menu: Customer setting - uses the IP address input below • • 94 Drop for downstream IP - uses the connecting devices' IP to the CPE Local IP Address Local IP address Source Subnet Mask
7368 ISAM CPE A-240Z-A Product Guide Procedure 28 Configure an A-240Z-A CPE URL filter configuration 1 Select Security > URL Filter from the top-level menu in the Ethernet Gateway window, as shown in Figure 37. Figure 37 URL Filter window Table 32 describes the fields in the URL Filter window.
Configure an A-240Z-A CPE Procedure 29 7368 ISAM CPE A-240Z-A Product Guide Parental control 1 Select Security > Parent Control from the top-level menu in the Ethernet Gateway window, as shown in Figure 38. Figure 38 Parental Control window Table 33 describes the fields in the Parental Control window.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE 4 Configure the parental control policy. 5 Click Enable to activate the policy. 6 STOP. This procedure is complete. Procedure 30 DMZ and ALG configuration 1 Select Security > DMZ and ALG from the top-level menu in the Ethernet Gateway window, as shown in Figure 39. Figure 39 DMZ and ALG window Table 34 describes the fields in the DMZ and ALG window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description WAN Connection List Choose a WAN connection from the drop-down menu Enable DMZ Select this checkbox to enable DMZ on the chosen WAN connection DMZ IP Address Choose Customer Setting and enter the DMZ IP address or choose the IP address of a connected device from the drop-down menu (2 of 2) 98 2 Configure ALG. 3 Click Save ALG. 4 Configure DMZ. 5 Click Save DMZ. 6 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Procedure 31 Configure an A-240Z-A CPE Access control configuration This procedure describes how to configure the access control level (ACL). Note 1 — ACL takes precedence over the firewall policy. Note 2 — The trusted network object will be shared for all WAN connections; it is not applied individually to a WAN connection. 1 Select Security > Access Control from the top-level menu in the Ethernet Gateway window, as shown in Figure 40.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description ICMP, Telnet, SSH, HTTP, TR-069, HTTPS Select an access control level for each protocol: Source IP Start Enter a start IP address for the new subnet trusted network Source IP End Enter an end IP address for the new subnet trusted network WAN side: Allow, Deny, or Trusted Network Only LAN side: Allow or Deny (2 of 2) 2 Select a WAN connection from the drop-down menu. 3 Click to enable or disable Trusted Network.
7368 ISAM CPE A-240Z-A Product Guide Procedure 32 Configure an A-240Z-A CPE Port forwarding configuration 1 Select Application > Port forwarding from the top-level menu in the Ethernet Gateway window, as shown in Figure 41. Figure 41 Port forwarding window Table 36 describes the fields in the port forwarding window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide 2 Configure port forwarding. 3 Click Add. 4 STOP. This procedure is complete. Procedure 33 Port triggering 1 Select Application > Port Triggering from the top-level menu in the Ethernet Gateway window, as shown in Figure 42. Figure 42 Port Triggering window Table 36 describes the fields in the Port Triggering window.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE Field Description Triggering Port Enter the triggering port range Expire Time Enter the expiration time in seconds Open Protocol Choose the open port protocol from the drop-down menu: • TCP • UDP • Trigger Protocol TCP/UDP Choose the triggering port protocol from the drop-down menu: • TCP • UDP • TCP/UDP Enable Triggering Select this checkbox to enable port triggering WAN Connection List Choose a WAN connection from the drop-do
Configure an A-240Z-A CPE Procedure 34 7368 ISAM CPE A-240Z-A Product Guide DDNS configuration 1 Select Application > DDNS from the top-level menu in the Ethernet Gateway window, as shown in Figure 43. Figure 43 DDNS window Table 38 describes the fields in the DDNS window.
7368 ISAM CPE A-240Z-A Product Guide 3 Click Save. 4 STOP. This procedure is complete. Procedure 35 NTP configuration 1 Select Application > NTP from the top-level menu in the Ethernet Gateway window, as shown in Figure 44. Figure 44 Issue: 01 Configure an A-240Z-A CPE NTP window 2 Select the Enable NTP Service checkbox. 3 Click Save. 4 STOP. This procedure is complete.
Configure an A-240Z-A CPE Procedure 36 7368 ISAM CPE A-240Z-A Product Guide USB configuration 1 Select Application > USB from the top-level menu in the Ethernet Gateway window, as shown in Figure 45. A USB printer that is connected to the ONT is available to all LAN devices. Figure 45 USB window Table 39 describes the fields in the USB window.
7368 ISAM CPE A-240Z-A Product Guide Configure an A-240Z-A CPE Field Description Re-enter Password Password for SFTP server Enable Samba server Select this checkbox to enable using a Samba server Workgroup Enter the name for the Samba work group Samba Username Username for Samba server Samba Password Password for Samba server Re-enter Samba Password Password for Samba server Enable Printer Sharing Select this checkbox to enable printer sharing Printer sharing is disabled by default Connect
Configure an A-240Z-A CPE Procedure 37 UPnP and DLNA configuration 1 Select Application > UPnP and DLNA from the top-level menu in the Ethernet Gateway window, as shown in Figure 46. Figure 46 108 7368 ISAM CPE A-240Z-A Product Guide UPnP and DLNA window 2 Select the Enable UPnP checkbox to enable UPnP. 3 Click Save/Apply. 4 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Procedure 38 Configure an A-240Z-A CPE Voice setting 1 Select Application > Voice Setting from the top-level menu in the Ethernet Gateway window, as shown in Figure 47. Figure 47 Voice setting window Table 40 describes the fields in the Voice Setting window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description Register Server Enter the register server Register Port Enter the register port User Agent Domain Enter the user agent domain DTMF Mode Choose InBand, rfc2822, Info, or Auto from the drop-down menu FaxT38 Choose False or True from the drop-down menu Line Choose a line from the drop-down menu Enable Choose Enabled or Disabled from the drop-down menu Directory Number Enter a directory number AuthUserName Ente
7368 ISAM CPE A-240Z-A Product Guide Procedure 39 Configure an A-240Z-A CPE Password configuration 1 Select Maintenance > Password from the top-level menu in the Ethernet Gateway window, as shown in Figure 48. Figure 48 Password window Table 41 describes the fields in the password window.
Configure an A-240Z-A CPE Procedure 40 7368 ISAM CPE A-240Z-A Product Guide WAN speed test 1 Select Maintenance > Speed Test from the top-level menu in the Ethernet Gateway window, as shown in Figure 49. Figure 49 2 Speed Test window Click Start to start the speed test. Enter the URL for the test server in the pop-up window. 3 112 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Procedure 41 Configure an A-240Z-A CPE Device management 1 Select Maintenance > Device Management from the top-level menu in the Ethernet Gateway window, as shown in Figure 50. Figure 50 Device management window Table 42 describes the fields in the Device management window.
Configure an A-240Z-A CPE Procedure 42 Uplink management 1 Select Maintenance > Uplink Management from the top-level menu in the Ethernet Gateway window, as shown in Figure 51. Figure 51 114 7368 ISAM CPE A-240Z-A Product Guide Uplink Management window 2 Select a Work Mode: Ethernet Only or Ethernet with 3G/4G Dongle Backup. 3 Click Save. 4 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Procedure 43 Configure an A-240Z-A CPE Dongle management 1 Select Maintenance > Dongle Management from the top-level menu in the Ethernet Gateway window, as shown in Figure 52. Figure 52 Dongle management window Table 42 describes the fields in the Dongle management window.
Configure an A-240Z-A CPE 4 Configure the SIM card. 5 Click Save. 6 Configure the access point. 7 Click Save. 8 STOP. This procedure is complete. Procedure 44 Backup and restore 1 Select Maintenance > Backup and Restore from the top-level menu in the Ethernet Gateway window, as shown in Figure 53. Figure 53 2 116 7368 ISAM CPE A-240Z-A Product Guide Backup and Restore window Click Select File and choose the backup file.
7368 ISAM CPE A-240Z-A Product Guide 3 Click Import Config File to restore the CPE to the saved backup or click Export Config File to export the current CPE configuration to the backup file. 4 STOP. This procedure is complete. Procedure 45 Upgrade firmware 1 Select Maintenance > Firmware Upgrade from the top-level menu in the Ethernet Gateway window, as shown in Figure 54. Figure 54 Issue: 01 Configure an A-240Z-A CPE Firmware upgrade window 2 Click Select File and choose the firmware file.
Configure an A-240Z-A CPE Procedure 46 Reboot CPE 1 Select Maintenance > Reboot Device from the top-level menu in the Ethernet Gateway window, as shown in Figure 55. Figure 55 118 7368 ISAM CPE A-240Z-A Product Guide Reboot window 2 Click Reboot to reboot the CPE. 3 STOP. This procedure is complete.
7368 ISAM CPE A-240Z-A Product Guide Procedure 47 Configure an A-240Z-A CPE Restore factory defaults 1 Select Maintenance > Factory Default from the top-level menu in the Ethernet Gateway window, as shown in Figure 56. Figure 56 Factory default window Note — A factory reset also removes the IoT software image that was installed separately; see “IOT application software package download”. Issue: 01 2 Click Factory Default to reset the CPE to its factory default settings. 3 STOP.
Configure an A-240Z-A CPE Procedure 48 Diagnose connections 1 Select Maintenance > Diagnostics from the top-level menu in the Ethernet Gateway window, as shown in Figure 57. Figure 57 120 7368 ISAM CPE A-240Z-A Product Guide Diagnostics window 2 Choose a WAN connection to diagnose from the drop-down menu. 3 Enter the IP address or domain name. 4 Select the test type: ping, traceroute, or both. 5 Enter the number of ping attempts to perform (1 - 1000); the default is 4.
7368 ISAM CPE A-240Z-A Product Guide 8 Click Start Test. Results will be displayed at the bottom of the window. 9 Click Cancel to cancel the test. 10 STOP. This procedure is complete. Procedure 49 View log files 1 Select Maintenance > Log from the top-level menu in the Ethernet Gateway window, as shown in Figure 58.
Configure an A-240Z-A CPE 2 Choose a write level from the drop-down menu to determine which types of events are recorded in the log file: • • • • • • • • 3 7368 ISAM CPE A-240Z-A Product Guide Emergency Alert Critical Error Warning Notice Informational Debug Choose a reading level from the drop-down menu to determine which types of events to display from the log file: • • • • • • • • Emergency Alert Critical Error Warning Notice Informational Debug 4 The log file is displayed at the bottom of the
7368 ISAM CPE A-240Z-A Product Guide Figure 59 Configure an A-240Z-A CPE RG Troubleshooting Counters window Table 44 describes the fields in the RG Troubleshooting Counters window.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide Field Description DS Packet Loss The number of downstream packages lost Internet Status Whether the broadband connections is active (UP) or not (DOWN) Latency This test is used to determine the lowest round-trip time in milliseconds by pinging the target server multiple times Click Latency Test to specify the time for the test The default is weekly, performed at idle to a public server DNS Response Time This test is used to determine
7368 ISAM CPE A-240Z-A Product Guide Figure 60 Configure an A-240Z-A CPE Smart Home Status window Table 45 describes the fields in the Smart Home Status window.
Configure an A-240Z-A CPE Table 45 7368 ISAM CPE A-240Z-A Product Guide Smart Home Status parameters Field Description IOT Gateway Firmware Status Filename Firmware name Description Firmware description Download Status Download status: success or failure Download Failure Reason Failure reason (if applicable) IOT Gateway Information IOT GW version IOT gateway identifier JVM version Java Virtual Machine identifier Zwave Firmware version Zwave firmware identifier (if applicable) Zigbee Firm
7368 ISAM CPE A-240Z-A Product Guide Figure 61 Configure an A-240Z-A CPE Smart Home Configuration window Table 46 describes the fields in the Smart Home Configuration window.
Configure an A-240Z-A CPE Procedure 53 7368 ISAM CPE A-240Z-A Product Guide Smart Home maintenance 1 Select Smart Home>Maintenance from the left menu in the Ethernet Gateway window. The Smart Home Maintenance window appears; see Figure 62. Figure 62 Smart Home Maintenance window Table 47 describes the fields in the Smart Home Maintenance window.
7368 ISAM CPE A-240Z-A Product Guide 2 Configure the Smart Home maintenance. 3 STOP. This procedure is complete. 8.3 Configure an A-240Z-A CPE IOT application software package download The A-240Z-A CPE supports IOT. This section describes how to download the IOT application software package from the Auto Configuration Server (ACS) to the CPE and to activate the software. The filename for the IOT application software package is 3FE46043XXXXXX.
Configure an A-240Z-A CPE 7368 ISAM CPE A-240Z-A Product Guide This will start the IOT application. 6 130 STOP. This procedure is complete.
Customer document and product support Customer documentation Customer Documentation Welcome Page Technical Support Customer Documentation Technical Support Documentation feedback Customer Documentation Feedback
Copyright 2017 Nokia.