Installation Instructions

INSTALLATION INSTRUCTIONS
MODELS TS-2T, TS-3T, TS-4T, TS-5T
UL FILE SA32686
TERMINAL BLOCK WIRING (ALL MODELS)
Terminals Designation Notes
JP3 Power Input Power
12 to 24 Volts
AC or DC
60 mA maximum
JP1 (COM) Common Contact
Timed Contacts rated 2A @ 35VDC JP1 (NC) N/C Contact
JP1 (NO) N/O Contact
JP2 (+)
Positive Voltage
Terminal for
Pushbutton LED
Illumination
LED Current Draw -
12 VDC @ 7mA
24 VDC @ 18mA
JP2 (-)
Negative Voltage
Terminal for
Pushbutton LED
Illumination
Time Adjustment -
Turn pot clockwise for maximum time (45 seconds).
Turn pot counter-clockwise for minimum time (2 seconds).
Note: Timer activates when button is depressed. Subsequent depression will re-start the timer.
Alarm Controls
Phoenix, AZ 85044
(800) 645-5538
www.alarmcontrols.com
Mount Wallplate in a Vertical Position
in a 1.5 inch deep Electrical Box
Doc D-011 Rev. A
TS-3T, TS-5T PLATE LED WIRING
Colored Lead Designation Notes
Red +24V Positive Input Power Lead
LED Current Draw -
12 VDC @ 9mA
24 VDC @ 19mA
White +12V Positive Input Power Lead
Black Negative Input Power Lead