User Manual

Interlogix part number:
Alarm.com part number: ADC-IS-300-LP
Alarm.com Image Sensor Version 3 - Interlogix Installation Guide
1 Copyright © 2017 Alarm.com. All rights reserved. Rev 3.5
PRODUCT SUMMARY & TECHNICAL SPECIFICATIONS
The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in
camera designed to capture images during alarm or non-alarm events when motion is
detected.
Product Features:
Communicates wirelessly to the security control panel
35 foot detection range with a 90 degree horizontal FOV-ALR
Configurable PIR sensitivity and pet immunity settings
Image: VGA 640x480 pixels
Color Images (except in night vision)
Night vision image capture with infrared flash (black & white)
Tamper detection, walk test mode, supervision
All systems can support up to three Image Sensors
UL 639 certified
Technical Specifications:
Alarm.com Model Number: ADC-IS-300-LP
Interlogix Part Numbers:
Power Source: Recommended 2 AA 1.5v Energizer Ultimate Lithium Batteries.
Batteries: Refer to the Batteries section for details
Operating Temperature Range: 32° to 110°F for non-pet applications, 60° to 110°F for
pet applications.
Weight: 3.1 oz. (with batteries and without mounting accessories)
Dimensions: 3.1’’ h x 1.8’’ w x 2.3’’ d
Supervisory Interval: 100 minutes (sensor), 3 hours (alarm hardwire)
Wireless Signal Range: Greater than 400 ft open air
Color: White
Recommended Mounting Height and Angle: Refer to the Recommended Install
Height and Angle Table
Motion Profiles & Sensor Range: Refer to the PIR Sensitivity Settings Table
HARDWARE COMPATIBILITY REQUIREMENTS – By Panel
Panel
Panel
Version
Module
Firmware
Extra Hardware Other
Simon
XT
V1.3+ Firmware 146+
Requires Image
Sensor
Daughterboard for
modules with
firmware 185 or
lower. Compatible
with all
daughterboard
versions.
Daughterboard
will take one
zone
Simon
XTi
V1.0+ Firmware 151+ No
Concord
4.0+
CDMA – v177+
HSPA – v183+
Requires
daughterboard with
v104.0+
All Image
Sensors must be
enrolled in same
partition.
OTHER FEATURE COMPATIBILITY
Two-Way Voice Compatibility - Images cannot be transmitted while a Two-Way Voice
call is in session. When the Image Sensor is installed on a system with Two-Way Voice
over the cellular network, image transmission during an alarm may be interrupted by the
two-way session. The image transmission resumes once the call has terminated.
Simon XT 2WTTS Compatibility - When using a Two Way Talking Touchscreen with the
Simon XT panel, Image Sensor activity during alarms is reported or visible on the
touchscreen. When alarms are tripped on an enrolled Image Sensor, the alarms are
reported and displayed on the 2WTTS through the sensor 39 hardwire zone. Periodic
activations on hardwire zone 39 will appear on the touchscreen as a result of the hardwire
supervisions.
PET IMMUNITY SETTINGS
Two parts to making the Image Sensor pet immune:
1. Set PIR sensitivity settings to “low”,
2. Mount set at a height of 6 ft, and install the sensor with the 6 degree mounting angle.
BATTERIES
Battery type: The Image Sensor uses 2 AA 1.5v Energizer Ultimate Lithium batteries (UL
compliant).
Expected Battery Life: Approximately 4 years with lithium batteries.
Voltage Thresholds: With lithium batteries, low battery alerts are issued at 3.05V. The
sensor cannot operate when the voltage reads below 2.30V.
Low Battery Notification: Panel will display a low battery alert for the sensor and/or
notifications are issued via the Alarm.com platform if the customer has subscribed to this
notification type.
Replacing batteries: To replace the sensor batteries, slide the front of the sensor up off
the sensor-back. Dispose of used batteries per the battery manufacturer instructions and
following local regulations.
Figure 1. Removing Sensor for Battery Replacement
CAMERA LED REFERENCE CHART
Camera LED Chart: Refer to this chart to understand the camera LED patterns.
Device Status or Error LED Pattern Duration of LED Pattern
Device & Network State
Sensor Power Up Red Blinking 3 seconds
Memory Check Red Solid 10 seconds
Searching for Unknown Network
Yellow Blinking 2 minutes
Searching for Known Network Green Blinking 2 minutes
Sensor Finds Network
Yellow Solid 5 seconds
Provisioning Yellow &
Green
Alternating
blinks
5-minute timeout
Connected and Provisioned
Green Solid 5 seconds
Device Reset
Network Reset Red
Blinking
(fast)
Hold the reset button for
ten seconds OR until the
LED flashes rapidly.
Hold Here