About This Manual Thank you for choosing the Akuvox C313W indoor monitor. This manual is intended for the administrators who need to properly configure the indoor monitor. This manual applies to the 213.30.6.53 version, and it provides all the configurations for the functions and features of the C313W indoor monitor. Please visit the Akuvox website or consult technical support for any new information or the latest firmware.
Introduction of Icons and Symbols Warning: Always abide by this information in order to prevent the persons from injury. Caution: Always abide by this information in order to prevent the damages to the device. Note: Informative information and advice from the efficient use of the device. Tip: Useful information for the quick and efficient use of the device.
Related Documentation You are advised to refer to the related documents for more technical information via the link below: https://knowledge.akuvox.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Table of Contents 1. Product Overview ...................................................................................... 1 2. Change Log ............................................................................................... 2 3. Model Difference ....................................................................................... 3 4. Introduction to Configuration Menu .......................................................... 4 5. Access the Device ...........................................
9.2.4. Contact Display .........................................................................31 9.2.5. Contacts Import and Export on the Web Interface ................. 32 10. Network Setting .................................................................................... 33 10.1. Device Network Configuration ..........................................................33 10.1.1. Configuring Network Connection on the Device ...................33 10.1.2.
14.2. Alarm and Arming Configuration ......................................................63 14.2.1. Configure Alarm and Arming on the Device .......................... 64 14.2.2. Configure Alarm and Arming on the Web Interface .............. 66 14.2.3. Configure Location-based Alarm on the device screen ....... 67 14.2.4. Configure Location-based Alarm on the Web Interface .......68 14.2.5. Configure Alarm Text ..............................................................69 14.2.6.
22. Password Modification ..........................................................................99 22.1. Modify Device Advanced Setting Password .................................... 99 22.2. Modify Device Web Interface Password .......................................... 99 23. System Reboot&Reset .........................................................................101 23.1. Reboot ..............................................................................................101 23.1.1.
C313W Indoor Monitor Administrator Guide 1.Product Overview It can be connected with the Akuvox door phone for audio/video communication, unlocking, and monitoring. Residents can communicate with visitors via audio/video call, and it supports unlocking the door remotely. It is more convenient and safer for residents to check the visitor’s identity through its video preview function. C313W are often applied to scenarios such as villas, apartments, and buildings. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 2.Change Log The change log will be updated here along with the changes in the new software version. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 3.Model Difference Model Feature C313W OS Display Linux 7 inch (176 mm) diagonal Resolution Wi-Fi Ethernet Power Supply POE Alarm Input Relay Output Installation Operation Temperature Operation Humidity Dimensions (W x H x D) 800*480 IEEE802.11 b/g/n, @2.4GHz 2xRJ45, 10/100Mbps adaptive 12V DC connector 802.3af Power-over-Ethernet 8 1 Wall mounting 0°C ~ +45°C AKUVOX SMART INTERCOM 10~90% 200*132*17.5mm www.akuvox.
C313W Indoor Monitor Administrator Guide 4.Introduction to Configuration Menu Status: This section gives you basic information such as product information, Network Information, and account information, etc. Account: This section concerns SIP account, SIP server, proxy server, transport protocol type, audio&video codec, DTMF, session timer, etc. Network: This section mainly deals with DHCP&Static IP setting, RTP port setting, and device deployment, etc.
C313W Indoor Monitor Administrator Guide the device will be issued automatically from the cloud. If users decide to use Akuvox SmartPlus, please contact Akuvox technical support, and they will help you configure the related settings before using them. SDMC mode: SDMC (SIP Device Management Controller) is a simple and comprehensive software for building management.
C313W Indoor Monitor Administrator Guide 5.Access the Device Akuvox indoor monitor system settings can be either accessed on the device directly or on the device web interface. 5.1. Device Start-up Network Selection Akuvox indoor monitor system settings can be either accessed on the device directly or on the device's web interface. After the device boots up initially, you are required to select the network connection for the device.
C313W Indoor Monitor Administrator Guide 5.2. Device Home Screen Type Selection Akuvox indoor monitor supports two different home screen display modeCall list Mode, Nine Square Mode. To configure home page mode on the device web Phone->Key/Display, choose one suitable mode for your scenarios. 5.3. Accessing the Device Setting on the Device 5.3.1.Accessing Device Basic Setting. You can access the device's basic setting and advance setting where you can configure different types of functions as needed.
C313W Indoor Monitor Administrator Guide 5.3.2.Accessing Device Advanced Setting To access the advanced setting, press Setting then press Advance icon. Press password 123456 (by default) to enter the advanced setting. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 5.4. Access the Device Setting on the Web Interface You can also enter the device IP address on the web browser in order to log in the device web interface by user name and password admin/admin where you can configure and adjust parameter etc. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Tip: You can also obtain the device IP address using the Akuvox IP scanner to log in the device web interface. Please refer to the URL below for the IP scanner application instruction: http://wiki.akuvox.com/doku.php?id=tool:ip_scanner&s[]=ip&s[]=sca nner Note: Google Chrome browser is strongly recommended. The Initial user name and password are “admin” and please be case-sensitive to the user names and passwords entered. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 6.Language and Time Setting 6.1. Language Setting When you first set up the device, you might need to set the language for your need or you can do it later if needed. And the language can either be set up directly on the device or on the device web interface according to your preference. 6.1.1.
C313W Indoor Monitor Administrator Guide 6.1.2. Language Setting on the Web Interface. To configure the language display on the device web Phone > Time/Lang interface. You can either setup the device display language or device web interface language on device web. 6.2. Time Setting Time setting can be set up on the device and on the device web interface in terms of time zone, date and time format etc. 6.2.1.Time Setting on the Device To set up time setting on the device More > Setting > Time screen.
C313W Indoor Monitor Administrator Guide Parameter Set-up: NTP: NTP is switched on by default, which allows the date& time to be automatically set up and synchronized with the default time zone and the NTP server (Network Time Protocol). You can also set it up manually by ticking the check box and then enter the time and date you want and press the Save tab to save the setting. Set Date: Enter the date when it is in manual mode. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Set Time: Enter the time when it is in manual mode. NTP server1&2: enter the NTP server you obtained in the NTP server field. Time Zone: select the specific time zone depending on where the device is used. The default time zone is GMT+0.00. Date Format: select the date format as you like among the three format options. The six formal options are Y-M-D, Y/M/D, D-M-Y, D/M/Y, M-D-Y, M/D/Y.
C313W Indoor Monitor Administrator Guide 6.2.2.2. Daylight Saving Time Setting In addition to time settings, you can also configure daylight saving time on the same interface. Modify the time parameters to achieve longer evening or day time, especially in summer. Parameter Set-up: AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Active: To enable or disable the daylight saving time. You can also configure to make C313W to adjust the daylight saving time automatically. Offset: To set the offset value, it is 60 mintues as default, setting the clocks an hour ahead of the standard time. By Date: To set the date schedule for daylight saving time. By Week: To set the schedule for daylight saving time according to the week and month. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 7.Screen Display Configuration C313W indoor monitor allow you to enjoy a variety of screen displays to enrich your visual and operational experience through the customized setting to your preference. 7.1. Screen Display setting on the Device You can configure a variety of features of the screen display in terms of brightness and screen saver, etc. You can do this configuration on device More > Setting > Display screen.
C313W Indoor Monitor Administrator Guide set it as 1 minute then the screen will be turned off if there is no operation on the device for 1 minute. However, if you turn on the function, then the device screen will not be turned off until screen saver display reaches its configured time duration. Screen Locker: tick the screen locker if you want to lock the screen after the screen is turned off (turn to dark).
C313W Indoor Monitor Administrator Guide Screen Saver Options: select screen saver type among seven options: SDMC, Local Album, SDMC+Local Album. Details for the screen saver types are shown below: NO . Screen Saver Type Type Description 1 SDMC Pictures Display pictures from SDMC as the screen saver. 2 Local Pictures Display picture uploaded to the indoor monitor as the screen saver. 3 SDMC+Loca Display pictures from SDMC and the indoor monitor in l Pictures rotation as the screen saver.
C313W Indoor Monitor Administrator Guide 7.4. Upload Device Booting Image You can upload the booting image to be displayed during the device’s booting process if needed on device web interface Phone > Album > Logo. Note: The pictures uploaded should be in .png or .zip format. 7.5. Upload Web interface logo You can upload the logo image to be displayed on web interface if needed on device web interface Phone > Album > Logo. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Note: The pictures uploaded should be in .png format with 50k maximum. 7.6. Icon Screen Display Configuration C313W indoor monitor allow you to customize icon display on the home screen and More screen for the convenience of your operation on device web Phone > Key/Display interface. This article helps you to set up the icon display properly on the screens according to your preference. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Type: click to select among sixteen icon options: “DND”, “Message”,” Contact”, “Call”, “ Display” ,”Status” ,” Setting”, “ Sound”, “Arming”, “ SOS”, “Relay”, ”Lift”, “Smart Living”, “ Unlock”, “N/A” is selected, the icon display in the corresponding area will disappear. Label: click to rename the icon if need, while DND icon can not be renamed.
C313W Indoor Monitor Administrator Guide Note: You can configure 8 icons on the More screen. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 8.Sound and Volume Configuration Akuvox C313W indoor monitors provide you with various types of ringtone and volume configuration ranging from Mic volume, Ring volume, Talk volume, Tone volume and Media volume. You can configure them on the device directly or on the web interface. 8.1. Volume Configuration 8.1.1. Configure Volume on the Device To set up the volumes on the device screen More > Setting > Sound.
C313W Indoor Monitor Administrator Guide Ring Volume: adjust the incoming call ringtone volume. Talk Volume: adjust the speaker volume during the call. Mic Volume: adjust the volume of your voice to be heard. Touch Sound: To enable sound when you press screen. 8.1.2.Configure Volume on the Web Interface You can configure the tones and customize your doorbell sound by uploading the audio file to your preference on device web interface Phone > Ringtones.
C313W Indoor Monitor Administrator Guide 9.Phone Book Configuration 9.1. Phone Book Configuration on the Device You can configure the contacts list in terms of adding and modifying contact groups or contacts on the device More > Contacts directly. 9.1.1.Add Contacts Parameter Set-up: Contact Name: enter the name and save. Number: enter the IP or SIP number to save. Ring Tone: Select ring tone for this contact. Group: select Default or any other groups that have been created.
C313W Indoor Monitor Administrator Guide Account: select which account to use to dial out, Account 1 or Account 2. 9.1.2.Edit Contacts Select the exiting contact and click Edit to modify. 9.1.3.Blocklist Settings on the Device you can choose from the contact list the contact you want to add to the block list AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Note: You can delete contacts regardless of whether it is on the All Contacts screen or the Blocklist screen. 9.2. Phone Book Configuration on the Web Interface 9.2.1. Contact Configuration To conduct contact configuration on web Contacts > Local Contacts interface. The new contact will be shown in the below list after it is added. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Name: enter the contact name to be saved. Number: enter the contact number ( SIP or IP number ) to be saved. Group: select Default or Blocklist group. Account: select Account1 or Account2. 9.2.2. Contact Management You can search, display, edit, and delete the contacts in your contacts list on web Contacts > Local Contacts interface. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide You can dial out a number using the contact phone number on web Contacts > Local Contacts interface. 9.2.3. Block List Setting on the Web Interface You can set the blocklist directly in the contact list on the web Contacts > Local Contacts > Local Contacts List interface or set it when editing a contact. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Note: If you want to remove the contact from the blocklist on the web interface, you can change the group to the "Default" when editing the contact. 9.2.4.Contact Display You can configure the contact display order and control whether to display the discovery device on the device. Parameters Set-up: Contacts Sort By: There are three modes Default, ASCII code and Created time mode for showing the contact list.
C313W Indoor Monitor Administrator Guide 9.2.5.Contacts Import and Export on the Web Interface When the contact becomes so many that you can not afford to manage each contact one by one manually, you can import and export the contacts in batch on the device web Contacts > Local Contacts interface. Note: The contact file can only be imported or exported in .xml or .csv format. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 10. Network Setting 10.1.Device Network Configuration You can check for the C313W network connection info and configure the default DHCP mode (Dynamic Host Configuration Protocol) and static IP connection for the device either on the device or on the device web interface. 10.1.1. Configuring Network Connection on the Device To check and configure the network connection on the device screen More > Setting > Advance > Network.
C313W Indoor Monitor Administrator Guide mode is selected, then the IP address, subnet mask, default gateway, and DNS servers address have to be manually configured according to your actual network environment. IP Address: set up the IP Address if the static IP mode is selected. Subnet Mask: set up the subnet Mask according to your actual network environment. Gateway: set up the gateway according to the IP address of the default gateway.
C313W Indoor Monitor Administrator Guide To check and configure network connection on the device web Network > Basic interface. Parameter Set-up: DHCP: select the DHCP mode by checking the DHCP box. DHCP mode is the default network connection. If the DHCP mode is selected, then the indoor monitor will be assigned by the DHCP server with IP address, subnet mask, default gateway, and DNS servers address automatically. Static IP: select the Static IP mode by checking off the DHCP square box.
C313W Indoor Monitor Administrator Guide 10.2.Device Deployment in Network Akuvox C313W indoor monitors should be deployed before they can be properly configured in the network environment in terms of their location, operation mode, address and extension numbers as opposed to other devices for device control and the convenience of the management. To deploy the device in the network on web Network > Advanced > Connect Setting interface.
C313W Indoor Monitor Administrator Guide 10.3. Device NAT Setting NAT (Network Address Translation) allows hosts in an organization’s private intranet to transparently connect to hosts in the public domain. There is no need for internal hosts to have registered Internet addresses. It is a way to translate the internal private network IP address into a legal network IP address technology. To set up NAT, you can do it on web Account > Advanced > NAT interface.
C313W Indoor Monitor Administrator Guide 10.5.VLAN Setting VLAN (Virtual Local Area Network) is a logical grouping of two or more nodes which are not necessarily on the same physical network segment but which share the same logical IP domain. To be specify, the purpose of VLAN is to separate layer 2 broadcast domain. Within trunk links, the tagged packet will only be send to those ports with same VLAN ID. This is usually achieved by switch or router.
C313W Indoor Monitor Administrator Guide containing the specified VLAN-ID (VID). Packets containing the specified VID are marked with the priority level configured for the VID classifier. VLAN ID: Set the same VLAN ID as Switch or Router. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 11. Intercom Call Configuration 11.1.IP call & IP Call Configuration IP calls can be made directly on the intercom device by entering the IP number on the device. And you can also disable the direct IP call if you allow no IP call to be made on the device. To configure the IP call feature and port on the device web Phone > Call Feature > Others interface. Parameter Set-up: Direct IP Call: tick the check box to enable the direct IP call.
C313W Indoor Monitor Administrator Guide 11.3.SIP Account Registration Akuvox C313W indoor monitors support two SIP accounts that can all be registered according to your applications. For example, you can switch between the two SIP accounts. The SIP account can be configured on the device and on the device interface. To configure the SIP account on the device screen More > Setting > Advance > SIP Account.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Status: check to see if the SIP account is registered or not. Account: select Account1 or Account2. Account Enabled: check to active the registered SIP account. Display Label: configure the device label to be shown on the device screen. Display Name: configure the name, for example, the device’s name to be shown on the device being called to.
C313W Indoor Monitor Administrator Guide Registration Period: set up SIP account registration time pan. SIP re-registration will start automatically if the account registration fails during the registration time span. The default registration period is “1800”, ranging from 30-65535s. 11.5.
C313W Indoor Monitor Administrator Guide 11.6.SIP Call Configuration DND (Do not disturb) setting allows you not to be disturbed by any unwanted incoming SIP calls. You can set up DND related parameters properly on the device web Phone > Call Feature > DND interface to block SIP calls you do not intend to answer. In the meantime, you can also define the code to be sent to the SIP server when you want to reject the call. Parameter Set-up: DND: check Whole Day or Schedule to enable the DND function.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Starting RTP Port: enter the Port value in order to establish the start point for the exclusive data transmission range. Max RTP port: enter the Port value in order to establish the end point for the exclusive data transmission range. 11.8.
C313W Indoor Monitor Administrator Guide also the server port. Moreover, SRV can also be used to configure the priority and the weight of the server address. 11.9.Call Setting 11.9.1. Call Auto-answer Configuration C313W will auto answer all incoming calls if call auto-answer is enabled and receive live stream if live stream is enabled. To enable or disable on web Account > Advanced > Call > Auto Answer interface.
C313W Indoor Monitor Administrator Guide SIP/IP numbers can be imported to or exported out of the indoor monitor in batch on web Phone > Call Feature > Import/Export interface. Note: SIP/IP number files to be imported or exported must be in either .xml or .csv format. SIP/IP number must be set up in the phone book of the indoor monitor before they can be valid for the auto-answer function AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 11.10. Intercom Call Configuration If you want to see the image at the door station before answering the incoming call, you can enable the intercom preview function on web Phone > Intercom > Intercom Preview interface. Parameter Set-up: Intercom Preview: select enable to enable the incoming call preview function. Note: Group call is not available when you enable intercom preview function. 11.11.
C313W Indoor Monitor Administrator Guide Parameters Set-up: Prevent SIP Hacking: enable to active this feature during using sip call. This feature is only available for SIP call, not IP call. 11.12. Emergency Call Setting Emergency call is used to call out three emergency contacts when you are in urgent status. Especially for the elders and children. Press SOS key, the phone will automatically initiate the target SOS numbers. 11.12.1.
C313W Indoor Monitor Administrator Guide 11.12.2. SOS Number Settings on web Interface To set up SOS numbers on device web Phone > Intercom. Parameter Set-up: Call Number: to set up 3 SOS numbers. Once users press SOS key on the home screen (SOS display key shall be set on the web manually), indoor monitors will call out the number in order. Call Timeout: set up the timeout for each number.
C313W Indoor Monitor Administrator Guide 11.13. Multicast Configuration C313W allows you to conduct one-to-many broadcasting via multicast function on web Phone > Multicast interface. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Multicast Setting: to set the indoor monitor in one of the groups or disable this function. Multicast List: to fill in the parameters of multicast group. Indoor monitor will establish multicast calls to other indoor monitors which are set in multicast group. Listen List: to fill in the parameters of listen group. Indoor monitor will receive multicast calls if some indoor monitors call the listen group.
C313W Indoor Monitor Administrator Guide 11.14.1. Call Forwarding Configuration on the Device To do the configuration on the device screen More > Setting > Advance > Direct IP. Parameter Set-up: No Answer Forward: To enable no answer forwarding function; incoming calls will be forwarded to a specific number if phone is not answered. Forward Target: To enter the specific forward number if C313W enables No Answer Forwarding.
C313W Indoor Monitor Administrator Guide 11.14.2. Call Forwarding Configuration on the Web Interface To set up forward function on web Phone > Call Feature > Forward Transfer interface. Parameter Set-up: Account: To choose which account shall implement call forwarding feature. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 12. Intercom Message Setting You can read, create, and delete messages on the Message screen. 12.1.Manage Text Messages You can check, create and clear messages as needed on the indoor monitor screen Message > Text Message. Parameter Set-up: New: press this icon to create a new message Delete: press this icon to clear the messages that have been selected. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 12.2.Manage Voice Message You can create, delete and view the audio messages of family members recorded in device screen Message > Family MSG. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 13. Audio& Video Codec Configuration for SIP Calls 13.1.Audio Codec Configuration Akuvox indoor monitor supports four types of Codec (PCMU, PCMA, G729, G722) for encoding and decoding the audio data during the call session. Each type of Codec varies in terms of sound quality. You can select the specific codec with different bandwidth and sample rate flexibly according to the actual network environment.
C313W Indoor Monitor Administrator Guide 13.2.Video Codec Configuration C313W supports H264 codec. To do the configuration on web Account > Advanced > Video Codecs interface. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 14. Security 14.1.Monitor and Image 14.1.1. Monitor Setting You can configure the monitor setting on the web interface Phone > Monitor > Door phone. Parameter Set-up: Device Number: To enter the IP address or SIP number of the corresponding camera. Device Name: To enter the device name of doorphone, which could be set by users. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Destination URL: To set RTSP URL for the doorphone. The RTSP format of Akuvox doorphone is rtsp://device IP/live/ch00_0 User Name: To enter the user name if required. Password: To enter the password if required. Display in Call: Enable or Disable to display this monitor during the call. If enabled, when there is an incoming call from the monitor, the video will be displayed. You can also import or export the monitor list in batch in the same interface.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Device Name: To enter the name of third party camera. Destination URL: To set the RTSP URL for third party camera You can also import or export the monitor list in batch in the same interface. Import file can only support .xml format. 14.1.3. Video Image Capturing To capture video image by pressing Capture during monitor or a video call. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide You can also disable capture function on device web interface Phone > Key/Display > Others. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 14.2.Alarm and Arming Configuration Alarm feature is used to connect some alarm detection devices to protect your home safety. Akuvox indoor monitors support 8 alarm connectors which means you can connect 8 different alarm sensors in different rooms of your house. For example, connecting a smoker sensor in your kitchen to detect if AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide the gas is leaking, the indoor monitor will ring and send the alarm message to the target, like community property. Before checking Alarm feature on the device screen, you need to setup the Arming icon on the home page or more page on device web Phone > Key/Display interface. 14.2.1. Configure Alarm and Arming on the Device To set up a location-based alarm sensor on device screen More > Setting > Advance > Zone Settings. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Location: set up the location according to where the alarm sensor is stalled. You can select among ten location types: “Bedroom”, “Gate”, “Door” “ Guest room” ,“ Hall” ,“Window”, “ Balcony” ,“Kitchen”, “ Study” and "Bathroom”. Zone Type: set up the alarm sensor types. You can select among four sensor types: “Infrared”, “Drmagnet”, “Smoke”, “Gas”, “Urgency”.
C313W Indoor Monitor Administrator Guide 14.2.2. Configure Alarm and Arming on the Web Interface To set up a location-based alarm sensor on the device web interface Arming> Zone Setting > Zone Setting. Parameter Set-up: Location: set up the location according to where the alarm sensor is stalled. You can select among ten location types: “Bedroom”, “Gate”, “Door” “Guest room” ,“ Hall” ,“Window”, “ Balcony” ,“Kitchen”, “ Study” and "Bathroom”. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Zone Type: set up the alarm sensor types. You can select among four sensor types: “Infrared”, “Drmagnet”, “Smoke”, “Gas”, “Urgency”. Trigger Mode: set sensor trigger mode between “NC” and “NO” according to your need. Status: set the alarm sensor status among three options: “Enable”, “Disable”,”24H”. Select “Enable” if you want to enable to the alarm, however you are required to set the alarm again after an alarm is disarmed.
C313W Indoor Monitor Administrator Guide Parameters set up: Location: to display which location the detection device is located. Zone type: to display the type of detection device. Defence delay: it means when users enable the arming mode, there will be 90 seconds delay time for the alarm mode to be activated. Alarm delay: it means when the sensor triggered, there will be 90 seconds delay time to announce the notification.
C313W Indoor Monitor Administrator Guide 14.2.5. Configure Alarm Text After the alarm sensor is set up, you are allowed to customize your alarm text shown on the screen when an alarm is triggered on web Arming> Zone Setting > Customized Alarm interface. Enter the alarm text for the alarm at each location according to your need. 14.2.6. Configure Arming mode To switch arming mode, disarm the alarm on Arming screen by pressing their respective icons. Press Disarm icon if you want to clear the Arming Mode.
C313W Indoor Monitor Administrator Guide 14.2.7. Alarm Action Configuration The triggering of the alarm sensor can be accompanied by the actions you configured in forms of HTTP command, SIP Message, Call, Local Relay for different security purposes. 14.2.7.1. Select Alarm Action Types To select and set up actions on web Arming > Alarm Action interface.
C313W Indoor Monitor Administrator Guide SIP Message: enable SIP message if you want the SIP message to be sent to a designated SIP account as an action Call: enable Call if you want you a call to go to a designated SIP or IP number. Local relay: enable local relay if you want to trigger local relay as an action. 14.2.7.2.
C313W Indoor Monitor Administrator Guide 14.2.7.3. Configure Alarm Action via SIP Message To set up the SIP message action receiver on the same web interface. Enter the SIP account to which you want to send the configured SIP message as an action when the alarm is triggered. 14.2.7.4. Configure Alarm Action via SIP Call To set up the call action, you can enter the SIP or IP number of the device to be called as an action, then enable Alarm Siren for arming zone as needed. AKUVOX SMART INTERCOM www.
C313W Indoor Monitor Administrator Guide 14.2.8. Check Alarm Log To check alarm log on device Arming > Alarm Log screen. To delete the existing alarm log by clicking the top right corner delete AKUVOX SMART INTERCOM www.akuvox.com icon.
C313W Indoor Monitor Administrator Guide 14.3.Screen Unlock Setting You can enable screenlocker function directly on the device More > Setting > Display screen. The device screen will be locked over the sleep time. You are required to wake up the device through the password. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 14.3.1. Screen Unlock by PIN Code You can unlock device screen by entering the pre-configured PIN code when the screen is locked. Note: Default unlock PIN is 123456. 14.4.Client Certificate Setting Certificates can ensure communication integrity and privacy when deploying Akuvox IP phone. So, when user needs to establish SSL protocol, it is necessary to upload corresponding certificates for verification.
C313W Indoor Monitor Administrator Guide Web Server Certificate: it is the certificate that send to client for authentication when client require an SSL connection with Akuvox IP Phone. Currently, the format of certificate can be accepted by Akuvox IP Phone is *.PEM file. Client Certificate: When Akuvox IP Phone required an SSL connection with server, the phone must verify the server to make sure it can be trusted. and the server will send its certificate to the Akuvox IP Phone.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Index: Select the desired value from drop-down list of Index. If select Auto value, the uploaded certificate will be displayed by numeric order. If select value from 1 to 10, the uploaded certificate will be displayed according to the value that user selected. Select File: Click Choose file browse local drive, and locate the desired certificate. (*.
C313W Indoor Monitor Administrator Guide 14.5.Power Output Setting You can enable power output function for PON interface on device web interface Device Setting > Basic > Power Output Setting. Note: When the Power Output function is set to enabled, and the PON interface is connected with some particular exchangers, it may cause the device reboots repeatedly. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 15. Door Access Control Configuration 15.1.Relay Switch Setting 15.1.1. Local Relay Setting Local relays in Akuvox indoor monitor can be used to trigger the door access or Chime bell through local relay connector. You can do this configuration on web interface Phone > Relay > Relay Setting > Local Relay. Parameter set-up: DTMF: Set the DTMF code for local relay. Relay Interval: set the relay delay time after the relay is triggered.
C313W Indoor Monitor Administrator Guide Parameter Set-up: DTMF Code: To set DTMF code for the remote relay, which is “#” by default. 15.2.Web Relay Setting In addition to the relay that is connected to indoor monitor, you can also control the door access using the network-based web relay. To do this configuration on web Phone > Relay > Web Relay interface. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide Parameter Set-up: IP address: enter the web relay IP address. User Name: enter the User name provided by the web relay manufacturer. Password: enter the password provided by the web relay manufacturer. The passwords is authenticated via HTTP and you can define the passwords using “http get” in Action. Web Relay Action: enter the specific web relay action command provided by the web manufacturer for different actions by the web relay. 15.3.
C313W Indoor Monitor Administrator Guide How to Notify DTMF: select among four options: “Disable” “DTMF” “DTMF-Relay” “Telephone-Event” according to your need. DTMF Payload: select the payload 96-127 for data transmission identification. Note: Please refer to the chapter Relay Switch Setting for the specific DTMF code setting. Intercom devices involved must be consistent in the DTMF type, otherwise DTMF code cannot be applied. 15.3.2.
C313W Indoor Monitor Administrator Guide Parameter Set-up: IP/SIP: To configure IP address or SIP account to trigger a certain remote relay of doorphone by sending HTTP message. Username: Enter the device username to be used as a part of HTTP command to trigger the local relay. Password: Enter the device password to be used as part of HTTP command to trigger the local relay. Please refer to the following example: http://192.168.35.
C313W Indoor Monitor Administrator Guide AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 16. Device Integration with Third Party Device 16.1.Lift Control You can summon lift at home via lift control feature. 16.1.1. Configure Lift Control To enable and set the display status Lift icon on device web Phone > Lift> Lift Control interface. Parameter set-up: Status: click to enable or disable the lift1 button. Icon: click to select icon for the button. Label: enter the title for the button.
C313W Indoor Monitor Administrator Guide 16.1.2. Configure Lift Control Prompt When the lift controller receives the HTTP command, it will feedback the current lift status with a prompt. To do this configuration on web Phone > Lift> Hints interface. Edit the HTTP Status Code, feedback code from Lift control board. If there are huge amounts of prompts need to be add, you can click Export tab to export a template, after editing to import/export. 16.2.
C313W Indoor Monitor Administrator Guide Parameter Set-up: Status: Enable or Disable this button. If disable, the button won’t be appeared on home control page. Icon: Select On or Off. If On is selected, the icon display as yellow button. Select Off, the icon is white button. Label: It is used to custom the button display name. HTTP command: Setup the http command to trigger the sensor. Note: To configure Smart Living button on Phone > Key/Display. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 17. Firmware Upgrade Firmware of different versions for indoor monitor can be upgraded on the device web Upgrade > Basic interface. Note: Firmware files should be .rom format for upgrade. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 18. Backup Configuration files can be imported to or exported out of the device to your local PC on the device web Upgrade > Advanced > Others interface if needed. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 19. Auto-provisioning 19.1.Provisioning Principle Auto-provisioning is a feature used to configure or upgrade the devices in batch via third party servers. DHCP, PNP, TFTP, FTP, HTTPS are the protocols used by the Akuvox intercom devices to access the URL of the address of the third-party server which stores configuration files and firmware, which will then be used to update the firmware and the corresponding parameters on the door phone.
C313W Indoor Monitor Administrator Guide 19.2.Introduction to the Configuration Files for Auto-Provisioning Configuration files have two formats for the auto-provisioning. one is the general configuration files used for the general provisioning and other one is the MAC-based configuration provisioning.
C313W Indoor Monitor Administrator Guide 19.3.Autop Schedule Akuvox provides you with different Autop methods that enable the indoor monitor to perform provisioning for itself in a specific time according to your schedule. To set up the schedule on device web Upgrade > Advanced > Automatic Autop interface. Please see the picture below: Parameter Set-up: Power On: select “Power on”, if you want the device to perform Autop every time it boots up.
C313W Indoor Monitor Administrator Guide 19.4.Static Provisioning Configuration You can manually set up a specific server URL for downloading the firmware or configuration file on device web Upgrade > Advanced > Automatic Autop interface. If an autop schedule is set up, the indoor monitor will perform the auto provisioning on a specific timing according to autop schedule you set up.
C313W Indoor Monitor Administrator Guide Note: AES is one type of encryption, it should be configured only when the config file is encrypted with AES, otherwise leave the field blank. Note: server Address format: TFTP: tftp://192.168.0.19/ FTP: ftp://192.168.0.19/ (allows anonymous login) ftp://username:password@192.168.0.19/(requires a user name and password) HTTP: http://192.168.0.19/ (use the default port 80) http://192.168.0.
C313W Indoor Monitor Administrator Guide Note: The general configuration file for the in-batch provisioning is with the format “cfg” taking C313W as an example “r000000000313.cfg (9 “zeros” in total while the MAC-based configuration file for the specific device provisioning is with the format” MAC_Address of the device.cfg, for example “0C110504AE5B.cfg.” AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 20. Call Log If you want to check on the calls inclusive of the dial-out calls, received calls, and missed calls in a certain period of time, you can check and search the call log on the device web Contacts > Call Logs interface and export the call log from the device if needed. Parameter Set-up: Call History: select call history among four options: “All”, “Dialed” “Received”, “Missed”, “Forwarded” for the specific type of call log to be displayed.
C313W Indoor Monitor Administrator Guide 21. Debug 21.1.System Log for Debugging System log in the indoor monitor can be used for debugging purpose. If you want to export the system out to a local PC or to a remote server for debugging, you can set up the function on the web Upgrade > Advanced > System Log interface. Parameter Set-up: LogLevel: select log levels from 1 to 7 levels. You will be instructed by Akuvox technical staff about the specific log level to be entered for debugging purpose.
C313W Indoor Monitor Administrator Guide 21.2. PCAP for Debugging PCAP in Akuvox indoor monitor is used to capture the data package going in and out of the devices for debugging and troubleshooting purpose. You can set up the PCAP on the device web Upgrade > Advanced > PCAP interface properly before using it. Parameter Set-up: Specific Port: select the specific ports from 1-65535 so that only the dat a packet from the specific port can be captured. You can leave the field bl ank by default.
C313W Indoor Monitor Administrator Guide 22. Password Modification 22.1.Modify Device Advanced Setting Password This password is used to enter the advanced settings of the device, including password settings, account numbers, SOS numbers, network settings, etc. To modify the advanced setting password on device screen More > Setting > Advance > Password. The default password is 123456. 22.2.
C313W Indoor Monitor Administrator Guide Note: There are two accounts, one is admin, its password is admin, the other is user, its password is user. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 23. System Reboot&Reset 23.1.Reboot 23.1.1. Reboot on the Device If you want to reboot the system setting of the device, you can operate it directly on the device setting screen or on the device web interface. To reboot to the system setting on device Settings >Reboot screen. 23.1.2. Reboot on the Web Interface If you want to reboot the device system, you can operate it on the device web Upgrade > Basic interface as well.
C313W Indoor Monitor Administrator Guide To set up the device reboot schedule on web Upgrade > Advanced > Reboot Schedule interface. 23.2. Reset 23.2.1. Reset on the Device If you want to reset the whole device system to the factory setting, you can operate it directly on the device screen More > Setting > Advance > Reset. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 23.2.2. Reset on the Web Interface Device system can also be reset on device web Upgrade > Basic interface without approaching the device. If you only want to reset to the configuration file to the factory setting, you can click Reset Config To Factory Setting on the same page. AKUVOX SMART INTERCOM www.akuvox.
C313W Indoor Monitor Administrator Guide 24.
C313W Indoor Monitor Administrator Guide PCMU: Pulse Code Modulation µ-Law PCAP: Packet Capture PNP: Plug and Play RFID: Radio Frequency Identification RTP: Real-time Transport Protocol RTSP: Real Time Streaming Protocol MPEG: Moving Picture Experts Group MWI: Message Waiting Indicator NO: Normal Opened NC: Normal Connected NTP: Network Time Protocol NAT: Network Address Translation NVR: Network Video Recorder ONVIF: Open Network Video Interface Forum SIP: Session Initiation Protocol SNMP: Simple Network M
C313W Indoor Monitor Administrator Guide 25. FAQ Q1: How to obtain IP address of C313W A1: You can use the display screen to get the IP information, just check the IP address at More > Status. You can also use Akuvox IP Scanner to search Akuvox devices in the same LAN network. Q2: Do Akuvox devices support opus codec? A2: For now, only Akuvox Android video IP phone R48G can support Opus audio codec. Door phone and indoor monitor still not supports.
C313W Indoor Monitor Administrator Guide 26. Contact US For more information about the product, please visit us atwww.akuvox.com or feel free to contact us by Sales email: sales@akuvox.com Technical support email: support@akuvox.com Telephone: +86-592-2133061 ext.7694/8162 We highly appreciate your feedback about our products. AKUVOX SMART INTERCOM www.akuvox.