About This Manual Thank you for choosing Akuvox A03S access control terminal. This manual is intended for the administrators who need to properly configure the access control terminal. This manual applies to 103.30.2.23 version, and it provides all the configurations for the functions and features of A03S access control terminals. Please visit Akuvox forum or consult technical support for any new information or the latest firmware.
Introduction of Icons and Symbols Warning: Always abide by this information in order to prevent the persons from injury. Caution: Always abide by this information in order to prevent the damages to the device. Note: Informative information and advice from the efficient use of the device. Tip: Useful information for the quick and efficient use of the device.
Related Documentation You are advised to refer to the related documents for more technical information via the link below: https://knowledge.akuvox.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Table of Contents 1. Product Overview ...................................................................................... 1 2. Change Log ............................................................................................... 2 3. Model Specification .................................................................................. 3 4. Introduction to Configuration Menu .......................................................... 4 5. Access the Device .............................................
18. Auto-provisioning ................................................................................. 29 18.1. Provisioning Principle ....................................................................... 29 18.2. Configuration Files for Auto-provisioning ....................................... 30 18.3. AutoP Schedule ................................................................................. 30 18.4. DHCP Provisioning Configuration .................................................... 31 18.5.
A03S Access Control Admin Guide 1.Product Overview Akuvox Access control terminals A03S incorporate door controller and a RIFD reader in one standalone device, thus saving your solution costs. Equipped with a card reader (125kHz and 13.56MHz) which is capable of handling a majority of cards in wide use currently. A03S is designed to provide you with greater flexibility and security than those traditional access control systems.
A03S Access Control Admin Guide 2.Change Log The change log will be updated here along with the changes in new software version. AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide 3.Model Specification A03S Model & Feature Housing Material Front panel: Toughened Glass Frame: Aluminum Alloy Relay Out Input Wiegand PoE RAM ROM Card Reader Wi-Fi Bluetooth IP Rating LTE USB 1 2 √ √ 128M 128M 13.56MHz&125KHz X √ IP65 X X External SD Card X Wall Mounting √ Flush Mounting √ Desk Mounting X AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide 4.Introduction to Configuration Menu Status: this section gives you basic information such as product information, Network Information etc. As well as log related configurations such as access log. Directory: this section includes access schedule management and user management. Hardware: this section includes input type setting, relay setting, card setting, Wiegand and LED setting, volume setting.
A03S Access Control Admin Guide 5.Access the Device Before configuring Akuvox A03S, please make sure the device is installed correctly and connect a normal network. Using Akuvox IP scanner tool to search the device IP address in the same LAN. Then use the IP address to login in the web browser by user name and password admin and admin. Tip: Please refer to the URL below for the IP scanner application instructions: https://knowledge.akuvox.
A03S Access Control Admin Guide 6.Time Setting Time setting on the web interface allows you to set up time and date manually while allowing you to use NTP server address that you obtained to automatically synchronize your time and date. And when your time zone is selected, the device will automatically notify the NTP server of its time zone so that the NTP server can synchronize the time zone setting in your device. To configure the configuration on the device web System > Time interface.
A03S Access Control Admin Guide 7.LED Setting 7.1. Brightness Setting If you want to brighten up the brightness in order to see the card reader at greater ease in an environment with higher light intensity, you need to set up the related parameters in web Hardware > LED interface. Parameter Set-up: Backlight Intensity: adjust the backlight intensity, the bigger value, the brighter backlight. Backlight Enabled: tick the check box if want to enable the card reader LED lighting and vice versa.
A03S Access Control Admin Guide 8.Volume and Tone Configuration Volume and tone configuration in A03S access control terminal refers to tamper alarm volume, voice prompt volume and open-door tone configuration. Moreover, you can upload the tone you like to enrich your personalized user experience. 8.1.1. Volume Configuration You can configure the Mic volume according to your need for open-door notification.
A03S Access Control Admin Guide 9.Network Setting You can configure the default DHCP mode (Dynamic Host Configuration Protocol) and static IP connection. Moreover, you can set up IP address, Subnet Mask, Default Gateway, LAN DNS1 & LAN DNS2. To configure the configuration on web System > Network > LAN Port interface. Parameter Set-up: DHCP: select the DHCP mode by checking off the DHCP box. DHCP mode is the default network connection.
A03S Access Control Admin Guide 10. Relay Setting You can configure the relay switch(es) for the door access on the web interface. 10.1.1. Relay switch setting To configure the configuration on web Hardware > Relay > Relay interface. Parameter Set-up: Trigger Delay (Sec): set the relay trigger delay timing (Ranging from 1-10 Sec.) For example, if you set the delay time as “5” sec. then the relay will not be triggered until 5 seconds after you press “unlock” tab.
A03S Access Control Admin Guide 10.2.Web Relay Setting In additional to the relay that is connected to the access control terminal, you can also control the door access using the network-based web relay on the device and on the device web interface. 10.2.1. Configure Web Relay on the Web Interface Web relay needs to set up on the web interface where you are required to fill in such information as relay IP address, password, web relay action etc. Before you can achieve the door access via web relay.
A03S Access Control Admin Guide User Name: enter the User name provided by the web relay manufacturer. Password: enter the password provided by the web relay manufacturer. The password is authenticated via HTTP and you can define the passwords using “http get” in Action. Web Relay Action: enter the specific web relay action command provided by the web manufacturer for different actions by the web relay. http://admin:admin@192.168.1.2/state.xml?relayState=2.
A03S Access Control Admin Guide 11. Door Access Schedule Management You are required to configure and make schedule for the user-based door access via RF card. 11.1. Configure Door Access Schedule You can create door access schedules so that they can be later conveniently applied to the door access control intended for individual user or a group of users created. Moreover, you can edit your door access schedule if needed. 11.1.1.
A03S Access Control Admin Guide Click + Add to create a weekly schedule, select Schedule Mode as Weekly. Click + Add to create a longer period schedule, select Schedule Mode as Normal. 11.1.2. Import and Export Door Access Schedule In addition to creating door access schedule separately, you can also conveniently import or export the schedules in order to maximize your door access schedule management efficiency. To configure the configuration on web Directory > Schedule interface.
A03S Access Control Admin Guide Note: It only supports .xml format file for importing and exporting the schedule. AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide 12. Door Unlock Configuration A03S access control terminal offer you three types of door access via RF card. You can configure them on web interface. Moreover, you can import or exporting the user configured files including access control information. 12.1.Configure RF Card for Door Unlock 12.1.1. Configure RF Card on the Web Interface To configure the configuration on web Directory > User > RF Card interface. You need to click +Add tab to turn to RF Card interface.
A03S Access Control Admin Guide Parameter Set-up: IC/ID Card Display Mode: select the card format for the ID Card for the door access among five format options: 8H10D; 6H3D5D(W26); 6H8D; 8HN; 8HR. The card code format is 8HN by default in the access control terminal. 12.1.2. Unlock by NFC NFC(Near Field Communication) is popular way for door access. It uses radio waves for data transmission interaction. A0X supports to be unlocked by NFC.
A03S Access Control Admin Guide Parameter Set-up: Enable: enable the HTTP command unlock function by clicking on Enable field. User Name: enter the user name of the device web interface, for example: “Admin”. Password: enter the password for the HTTP command. For example: “12345”. Please refer to the following example: http://192.168.35.
A03S Access Control Admin Guide Parameter Set-up: Trigger Electrical Level: select the trigger electrical level options between “High” and “Low” according to the actual operation on the exit button. Action to execute: set actions to be triggered by the input. Email and HTTP URL actions are supported. HTTP URL: to set HTTP URL. Action Delay: set the action delay timing (Ranging from 1-300 Sec.) For example, if you set the delay time as “5”.
A03S Access Control Admin Guide You can enable BLE on Hardware>BLE. Parameter Set-up: Enabled: this feature is enabled by default. You can disabled it if it is unnecessary. Open Door Interval(Sec): select the time interval between the every two Bluetooth door accesses. Authentcation Code Valid Time: for the security, you can setup the authentication code valid time to avoid codes being paired indefinitely. The time can be set up from 1h to 24h.
A03S Access Control Admin Guide 13. Security 13.1.Tamper Alarm Setting Tamper alarm function serves as a protection against any unauthorized removal of the devices by triggering off the temper alarm on the device. To configure the configuration on web System > Security > Tamper Alarm interface. Parameter Set-up: Enable: tick the check box to enable the tamper alarm function. When the tamper alarm goes off, you can press the Disarm tab beside the check box to clear the alarm.
A03S Access Control Admin Guide 13.2.Security Notification Setting 13.2.1. Email Notification Setting If you want to receive the security notification via email, you can configure the Email notification on the web interface properly. To configure the configuration on web Services > Action > Email Notification interface. Parameter Set-up: Sender’s Email Name: enter the name of the email sender.
A03S Access Control Admin Guide SMTP password: configure the password of SMTP service, which is same with sender’s email address. Email subject: enter the subject of the email. Email content: compile the emails contents according to your need. AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide 14. Logs 14.1.Access Log If you want to search and check on door access history, you can search and check the door logs on the device web Status > Access Log interface. Parameter Set-up: Save Door Log Enabled: Tick the check box to turn on or turn off the door log function. Status: select between “Success” and “Failed” options to search for successful door accesses or Failed door accesses.
A03S Access Control Admin Guide 15. Debug 15.1.System Log for Debugging System log in the access control terminal can be used for debugging purpose. If you want to export the system out to a local PC or to a remote server for debugging, you can set up the function on the web System > Maintenance > System Log interface. Parameter Set-up: Log Level: select log levels from 1 to 7 levels. You will be instructed by Akuvox technical staff about the specific log level to be entered for debugging purpose.
A03S Access Control Admin Guide 15.2.PCAP for Debugging PCAP in A03S access control terminal is used to capture the data package going in and out of the devices for debugging and troubleshooting purpose. You can set up the PCAP on the device web System > Maintenance > PCAP interface properly before using it. Parameter Set-up: Specific Port: select the specific ports from 1-65535 so that only the data packet from the specific port can be captured. You can leave the field blank by default.
A03S Access Control Admin Guide 16. Firmware Upgrade Firmware of different versions for A03S access control terminal can be upgraded on the device web System > Upgrade interface. Note: Firmware files should be .rom format for upgrade. AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide 17. Backup Configuration files can be imported to or exported out of the device to your local PC on the device web System > Maintenance > Others interface if needed. AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide 18. Auto-provisioning Configurations and upgrading on A03S access control terminal can be done on the web interface via one-time auto-provisioning and scheduled autoprovisioning via configuration files, thus saving you from setting up configuration needed one by one manually on the access control terminal. 18.1.Provisioning Principle Auto-provisioning is a feature used to configure or upgrade the devices in batch via third party servers.
A03S Access Control Admin Guide 18.2. Configuration Files for Auto-provisioning Configuration files have two formats for the auto-provisioning. one is the general configuration files used for the general provisioning and other one is the MAC-based configuration provisioning.
A03S Access Control Admin Guide Parameter Set-up: Power On: select “Power on”, if you want the device to perform Autop every time it boots up. Repeatedly: select “Repeatedly”, if you want the device to perform autop according to the schedule you set up. Power On + Repeatedly: select “Power On + Repeatedly” if you want to combine Power On mode and Repeatedly mode that will enable the device to perform Autop every time it boots up or according to the schedule you set up.
A03S Access Control Admin Guide Note: The custom Option type must be a string. The value is the URL of TFTP server. Parameter Set-up: Custom Option: enter the DHCP code that matched with corresponding URL so that device will find the configuration file server for the configuration or upgrading. AKUVOX SMART INTERCOM www.akuvox.
A03S Access Control Admin Guide DHCP Option 66: If none of the above is set, the device will automatically use DHCP Option 66 for getting the upgrade server URL. This is done within the software and the user does not need to specify this. To make it work, you need to configure the DHCP server for the option 66 with the update server URL in it. DHCP Option 43: If the device does not get an URL from DHCP Option 66, it will automatically use DHCP Option 43.
A03S Access Control Admin Guide Parameter set-up: URL: set up tftp, http, https, ftp server address for the provisioning. User Name: set up a user name if the server needs an user name to be accessed to otherwise leave it blank. Password: set up a password if the server needs a password to be accessed to otherwise leave it blank. Common AES Key: set up AES code for the intercom to decipher general Auto Provisioning configuration file.
A03S Access Control Admin Guide Note: Server Address format: TFTP: tftp://192.168.0.19/ FTP: ftp://192.168.0.19/ (allows anonymous login) ftp://username:password@192.168.0.19/(requires a user name and password) HTTP: http://192.168.0.19/ (use the default port 80) http://192.168.0.19:8080/ (use other ports, such as 8080) HTTPS: https://192.168.0.19/ (use the default port 443) Tip: Akuvox do not provide user specified server. Please prepare TFTP/FTP/HTTP/HTTPS server by yourself.
A03S Access Control Admin Guide 19. Integration with Third Party Device 19.1.Integration via Wiegand If you want to integrate the access control terminal with the third-party devices via Wiegand, you can configure the Wiegand on the web Hardware > Wiegand interface. Parameter Set-up: Wiegand Display Mode:select Wigand Card code format among 8H10D; 6H3D5D; 6H8D; 8HN; 8HR; RAW. Wiegand Card Reader Mode: set the Wiegand data transmission format among three options: Wiegand 26, Wiegand 34, Wiegand 58.
A03S Access Control Admin Guide the established data transmission format. 19.2. Integration via HTTP API HTTP API is designed to achieve an network-based integration between the third party device with the Akuvox intercom device. You can configure the HTTP API function on the web Services > HTTP API interface for the integration. Parameter set-up: HTTP API: select “Enable” or “ Disable “ to enable or disable the HPTT API function for the third party integration.
A03S Access Control Admin Guide 20. Password Modification 20.1.Modify the Password On the device web interface, you can set and change password for accessing the web System > Security > Web Password Modify interface. In addition, you can also select the user role when setting passwords. 20.2.Web Interface Automatic Log-out You can set up the web interface automatic log-out timing, requiring re-login by entering the user name and the passwords for the security purpose or for the convenience of operation.
A03S Access Control Admin Guide 21. System Reboot and Reset 21.1.Reboot If you want to restart the device, you can operate it on the device web System > Upgrade > Basic interface as well. Moreover, you can set up schedule for the device to be restarted. To set up the device restart schedule on web System > Auto Provisioning > Reboot Schedule interface. 21.2.Reset If you want to reset the device system to the factory setting, you can it on the web System > Upgrade interface.
A03S Access Control Admin Guide 22.
A03S Access Control Admin Guide PCMA: Pulse Code Modulation A-Law PCMU: Pulse Code Modulation µ-Law PCAP: Packet Capture PNP: Plug and Play RFID: Radio Frequency Identification RTP: Real-time Transport Protocol RTSP: Real Time Streaming Protocol MPEG: Moving Picture Experts Group MWI: Message Waiting Indicator NO: Normal Opened NC: Normal Connected NTP: Network Time Protocol NAT: Network Address Translation NVR: Network Video Recorder ONVIF: Open Network Video Interface Forum SIP: Session Initiation Protoc
A03S Access Control Admin Guide 23. FAQ Q1: How to obtain IP address of access control terminal? A1: Using Akuvox IP Scanner to search Akuvox devices in the same LAN network. Q2: What is the supported temperature range for A03S ? A2: Working Temperature: -20°C ~ +55°C Storage Temperature: -30°C ~ +70°C Q3: Do Akuvox devices support Modbus protocol? A3: No.
A03S Access Control Admin Guide 24. Contact Us For more information about the product, please visit us at www.akuvox.com or feel free to contact us by Sales email: sales@akuvox.com Technical support email: support@akuvox.com Telephone: +86-592-2133061 ext.7694/8162 We highly appreciate your feedback about our products. AKUVOX SMART INTERCOM www.akuvox.