OPERATING MANUAL SESAM 800 K3, RX DIN USA 946415-000-A0
Table of Contents 1 2 Introduction_______________________________________ 3 Scope____________________________________________ 3 2.1 Safety Considerations______________________________________4 2.2 Warnings________________________________________________6 3 4 Technical specifications_____________________________ 7 Description of the system ___________________________ 8 4.1 Receiver_________________________________________________8 4.
Introduction 1 3 (16) Introduction This manual only covers the installation of the Sesam radio remote door opening system. The Sesam System is not a complete door opening system: it provides only the set of outputs that are driven according to the actions performed by the operator of the transmitter. The way the set of outputs is used for controlling the doors depends on the specific installation and is outside the scope of the Sesam.
Scope 2.1 4 (16) Safety Considerations 1. The safety guidelines in this manual are not intended to replace any rules or regulations or any applicable local, state, or federal governing laws. The following information is intended to be used in conjunction with other rules or regulations already in existence. It is important to read all safety information before operating any wireless radio remote control system. 2.
Scope 5 (16) 7. Radio controlled operators should always position themselves for the best view of the equipment they are controlling. The equipment should never be operated blindly. The operator should always remain at a safe distance, without losing line of sight with the equipment. 8. Transmitter switches should never be mechanically blocked ON or OFF for any equipment motion. 9. After daily operation, a secure storage space should be designated for the transmitter unit especially when not in use.
Scope 2.2 6 (16) Warnings 1. Read this manual carefully before operating and installing this product. 2. Due to the complex nature of equipment, it is necessary to read the entire manual before installation. 3. Only authorized personnel should service this equipment. Unauthorized work on this unit will void the warranty. 4. This manual is for reference only; please call your distributor or Åkerströms Björbo if further assistance is required. 5.
Technical specifications 3 7 (16) Technical specifications Table 1. Technical Specifications, Sesam 800 K3 & RX DIN System Specifications Operating frequency: 926.
Description of the system 8 (16) 4 Description of the system 4.1 Receiver This document covers receiver model Sesam 800 RX DIN 4.2 • 3 Single Pole Double Throw relays. • Memory capacity: up to 100 transmitters. • Designed for DIN rail Transmitter This document covers transmitter model Sesam 800 Keyring K3: 5 Figure 1. • Miniature 3 button transmitter. • Suitable for controlling 3 non-response time critical functions.
Installation of the receiver 6 9 (16) Installation of the receiver The permanent installation of the receiver must include fuses that protect the equipment and wiring from overcurrent and short-circuit. In detail the power supply of the receiver and all relay contacts must be fused. All fuses are used as disconnecting devices. The fuses shall be easily accessible, must submit a contact gap of at least 3.0 mm and have to be placed in the line pole. Note that the fuse must be compatible with IEC 60127-2/V.
Installation of the receiver 6.2 10 (16) Antenna connector The antenna connector on the receiver may not be used and are therefor blocked. 6.3 Connections on the receiver The receiver is equipped with connections for relays and power (see fig. 1). The connections for power connection are, from left to right: • Line (L) • Neutral (N) The connections for each relay are, from left to right: • Common terminal • Normally opened (NO) • Normally closed (NC) L 1 (C) N 2 3 (NO) (NC) R1 Figure 3.
Indicators on the receiver 7 11 (16) Indicators on the receiver The Sesam 800 RX DIN model has three LED indicators that is displaying system information (see fig. 1 for positions of the LEDs). The indications on the LEDs are as follows: 1. LED 5 Squelch: Indicates a detected signal on the operating frequency band. 2. LED 6 Status: Indicates that information from a transmitter associated with the receiver has been received. 3. LED 7 Learn: Indicates if the transmitter is in Learn Mode.
Configuration of the receiver 8.2 12 (16) Advanced configuration This configuration allows the user to determine which button activates a specific relay. 1. Open the lid on the receiver, see basic configuration. 2. Press the Learn/Erase button until LED 7 is ON. The Learn Mode will be active for 10 seconds. a. Press the Learn/Erase button once in order to select relay one (the status LED will flash once). b.
Description of Sesam 800 K3 transmitter 9 13 (16) Description of Sesam 800 K3 transmitter 1 2 Figure 4. 9.1 The Sesam 800 K3 transmitter indicators and buttons 1. Status LED 2. Buttons 1..3 Indications on the transmitter Normal operation Quick flashing RED = Sending message. Continuous GREEN = Relay activated in the receiver (Feedback information from receiver). Fault indications 3 long RED flashes = Battery depleted, transmitter can not send commands.
Replacing batteries in the transmitter 14 (16) 10 Replacing batteries in the transmitter 10.1 Replacing batteries in Sesam K3 If the indication LED on the transmitter indicates low battery, replace the batteries promptly. Before changing the batteries note that changing of batteries must take place in a clean environment free from static electricity. The batteries are changed as follows: 1. Open the battery cover by unscrewing the 3 screws on the backside of the transmitter housing (see fig. 5). 2.
Error codes, Sesam 800 RX DIN 11 15 (16) Error codes, Sesam 800 RX DIN Any of the below error states is displayed with ten quick flashes on the Status LED (LED 6) regardless of fault. ID already programmed Memory full Memory card mismatch during power up Memory card write error. Maybe memory card has been removed during operation. Memory card copy to verify error Internal errors. The unit needs service Line power unstable Table 2. 12 Error codes Sesam 800 RX DIN Measure for Sesam 800 RX DIN 72.
Åkerströms Björbo AB Box 7, SE-785 21 Gagnef, Sweden street Björbovägen 143 SE-785 45 Björbo, Sweden Phone +46 241 250 00 Fax +46 241 232 99 E-mail sales@akerstroms.com www.akerstroms.