Installing the BSPS Symptom Hardware Installation Guide Possible Cause Remedy between any two modules). • Rectifier(s) are not properly adjusted. • Re-adjust the voltage of the problematic rectifier(s). Battery backup time is too low • Battery is too small for the application. • Increase battery capacity • Charging voltage is too low • Weak battery 7-28 • Raise the system output voltage using the “VOLT ADJ.
Part II Installing WipLL Customer Premises Equipment Part II describes the procedures for installing the WipLL equipment located at the subscriber’s premises.
This page is intentionally left blank.
8 Installing the SPR This chapter describes the installation of the WipLL Subscriber Premises Radio (SPR) at the subscriber's premises.
Installing the SPR Hardware Installation Guide 8.1. Overview The SPR receives and transmits data from and to the base station. The SPR connects to the subscriber’s network through the SDA. The SDA is an Ethernet hub/LAN switch (depending on SDA model) that provides the SPR with DC power, lightening protection, and Ethernet (10Base-T and/or 100Base-T )connectivity to the subscriber’s PCs/network (up to four PCs depending on SDA model). The SPR connects to the SDA by a CAT-5 cable.
Hardw are Installation Guide Installing the SPR RF link CAT-5e Subscriber Premises Radio (SPR) located on the roof PC Subscriber Data Adapter (SDA) located inside Figure 8-1: Typical SPR and SDA location and connections at subscriber's premises Warning: As the system emits microwave radiation, a minimum distance of 200 mm must be maintained from the front of the SPR.
Installing the SPR Hardware Installation Guide Note: The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Hardw are Installation Guide Installing the SPR 8.2. Physical Dimensions and Basic Design The SPR is encased in a chassis and provides access to the SPR’s communication port at the front panel. The SPR’s bottom panel provides holes for mounting the SPR to, for example, a pole or wall (see Figure 8-3).
Installing the SPR Hardware Installation Guide 8.3. Cable Guidelines The following lists cable installation guidelines at the subscriber's premises: ! To prevent tripping, a wiring duct is to be provided at the subscriber's premises to house data cables. Wiring channel type, location, and methods of securing are to be discussed with the subscriber. ! Cables not housed in wiring channel must be dressed in a manner to avoid a trip hazard. Avoid trailing wires across passageways.
Hardw are Installation Guide Installing the SPR 8.4. Mounting the SPR The SPR can be mounted on a wall or pole. The SPR is mounted using the mounting holes located on the SPR’s bottom panel (see Figure 8-3), and the mounting bracket (provided). The mounting brackets for wall- and pole-mounting are different from one another. Mounting holes Figure 8-3: SPR bottom panel providing holes for mounting 02030311-05 Airspan Networks Ltd.
Installing the SPR Hardware Installation Guide 8.4.1. Minimum Distance between SPRs A minimum of 3-meter separation is required between mounted SPRs and existing customer radio equipment when not transmitting on the same sector (see Figure 8-4). 3.0 metres Figure 8-4: SPR separation when not transmitting on the same sector A 1-meter separation is required between SPRs when on the same sector and transmitting to the same BSR without requiring shielding (see Figure 8-5). 1.
Hardw are Installation Guide Installing the SPR 8.4.2. Wall-Mounting SPR wall mounting is performed in two chronological stages: ! Attaching the mounting bracket to the SPR’s mounting holes. ! Attaching the mounting bracket (attached to the SPR) to the wall. To mount the SPR on a wall: 1. Attach the mounting bracket to the SPR using two stainless steel bolts, as shown in Figure 8-6.
Installing the SPR Hardware Installation Guide 8mm 58mm 99mm . Figure 8-7: SPR mounting bracket dimensions for the four fixing holes Note: Airspan does not provide screws for attaching the mounting bracket to the wall. The screw size depends on the structure of the building to which the bracket is to be attached. When selecting screw sizes, consideration must be given to the weight of the SPR and load that may be induced in windy conditions. 8-10 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SPR 3. Adjust the horizontal positioning of the SPR, and then fasten tight the two stainless-steel bolts. Rotation is restricted to the horizontal plane only. The permissible rotation is shown in Figure 8-8. Figure 8-8: Horizontal rotation of the SPR Note: A thread-locking compound is to be used to prevent the bolts working loose. 02030311-05 Airspan Networks Ltd.
Installing the SPR Hardware Installation Guide 8.4.3. Pole-Mounting The SPR can be mounted on a pole (see Figure 8-9). Pole mounting allows the SPR to be adjusted in the horizontal as well as the vertical plane. The pole-mounting bracket assembly is designed to support the SPR on a round pole of 45 mm in diameter. Figure 8-9: Mounted SPR 8-12 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SPR To mount the SPR on a pole: 1. Attach the mounting bracket to the SPR using two stainless steel bolts. Locking Holes BSR mounting Bracket Clamping Bracket Pivot Hole ‘U’ Bolt Figure 8-10: SPR mounting bracket assembly 2. Attach the clamping bracket to the mounting bracket using two M8 stainless bolts. 3.
Installing the SPR Hardware Installation Guide 4. Adjust the vertical position of the SPR. Lock the SPR at the desired position by inserting the locking bolt in the desired position. Once the correct angle has been set both bolts must be tightened to lock the SPR bracket in place. 5. Adjust the horizontal position of the SPR by rotating the SPR about the pole, and then tighten the U-bolt. SPR positioning is obtained in two planes by adjustment of the mounting bracket assembly a shown in Figure 8-11.
Hardw are Installation Guide Installing the SPR 8.5. Connecting a Third-Party External Antenna (Optional) The SPR model with an N-type connector can be connected to an external antenna. The addition of an external antenna allows greater RF sector coverage than the standard SPR internal antenna models (i.e., 60°).
Installing the SPR Hardware Installation Guide To connect the SPR to an external antenna: ! Attach an N-type male connector of the third-party antenna to the N-type receptacle located on the SPR’s front panel. Figure 8-13: SPR model with N-type connector for attaching an external antenna Note: Airspan supplies unterminated cables for N-type connectors. Refer to Appendix B, “Cable Crimping" for N-type cable crimping. 8-16 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SPR 8.6. Connecting to the SDA The SPR connects to the subscriber’s PCs/network through the SDA. To connect the SPR to the SDA, you need to connect the SPR’s 15-Pin D-type port to the SDA’s 15-pin D-type port by a CAT-5e cable. The SPR-to-SDA cable connection configurations is as follows: ! Connectors: ! SPR: 15-pin D-type male (only 8 pins are used) ! SDA: 15-pin D-type male (only 8 pins are used) Note: Airspan supplies unterminated CAT-5e cables.
Installing the SPR Hardware Installation Guide Notes: - Pins 9 through 15 of the 15-pin D-type connector are not used. - The wire color-coding described in the table is WipLL's standard for wire color-coding. However, if you implement your company's wire color-coding scheme, ensure that the wires are paired and twisted according to the pin functions listed in Table 8-2 (e.g., Rx+ with Rx-).
Hardw are Installation Guide Installing the SPR Notes: 1) The wires are twisted together in pairs, for example, blue/white with blue, and orange/white with orange. This prevents electrical interference between the transmitter pins. For example, pin 3 (Tx+; orange / white) is paired and twisted with pin 4 (Tx-; orange). 2) The SDA connector pinouts are the same for all SDA models (SDA-1, SDA4H, SDA-4S, SDA-4S/VL, SDA-4S/Vltag, SDA-4S/1H3L, and SDA4S/VL/1H3L).
Installing the SPR Hardware Installation Guide Figure 8-15: SPR-to-SDA cable connections Note: The maximum cable length permissible between the SPR and SDA is 100 meters. 8-20 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SPR 8.7. Connecting to a PC for Serial Configuration To configure an SPR, you need to connect a PC running the WipLL network management system (WipConfig) to the SPR. The SPR’s 15-pin D-type port provides serial interface to a PC for SPR initial configuration. This port uses 9 of its 15 pins for serial interface; the remaining pins are used for interfacing with the SDA with which the SPR remains connected. To connect the SPR to the management station (i.e.
Installing the SPR Hardware Installation Guide ! Connector pinouts: Table 8-3: Y-cable SPR-to-SDA connector pinouts SPR 15-pin D-type male SDA Pin Function Pin Function 1 0 VDC 1 +48 VDC 2 +48 VDC 2 -48 VDC 3 Ethernet Tx+ 3 Rx+ 4 Ethernet Tx- 4 Rx- 5 Ethernet Rx+ 5 Tx+ 6 Ethernet Rx- 6 Tx- 7 Hop Sync+ 7 Sync.+ 8 Hop Sync- 8 Sync.
Hardw are Installation Guide Installing the SPR The Y-cable connector pin assignments are displayed shematically in Figure 8-17. Figure 8-17: Y-cable connector pin assignment To connect the SPR to a PC for serial configuration: 1. Connect the 15-pin D-type male connector (P1), at the one end of the Y-cable, to the SPR, as displayed in Figure 8-18. 2. Connect the 15-pin D-type male connector (J1), at the other end of the Y-cable, to the SDA, as displayed in Figure 8-18. 3.
Installing the SPR Hardware Installation Guide Figure 8-18: SPR cable connections for serial configuration Note: For performing SPR initial configuration using WipLL’s management applications, refer to Airspan’s WipConfig User’s Guide or WipConfig PDA User’s Guide. 8-24 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SPR 8.8. Connecting the RSS LED Adapter The WipLL RSS LED adapter indicates the received signal strength (RSS) between the SPR and the BSR. This allows you to accurately position the SPR during installation for optimal radio frequency signal reception. The RSS LED adapter is connected between the SPR and SDA CAT 5 cable connection. The RSS LED adapter provides two 15-pin D-type ports: one for the SPR side; and the other for the SDA side.
Installing the SPR Hardware Installation Guide To connect the RSSI LED adapter: 1. Connect the 15-pin D-type male connector, at one end of the straight-through cable, to the SPR, as displayed in Figure 8-19. 2. Connect the 15-pin D-type female connector, at the other end of the straightthrough cable, to the RSS LED adapter, as displayed in Figure 8-19. 3.
Hardw are Installation Guide Installing the SPR Figure 8-19: Connecting the RSS LED adapter 02030311-05 Airspan Networks Ltd.
Installing the SPR Hardware Installation Guide Note: You can connect the RSS LED adapter’s 15-pin male port directly to the SPR’s 15-pin port, instead of using a cable. Table 8-5 describes the LEDs on the RSS LED adapter.
Hardw are Installation Guide Installing the SPR 8.9. Connecting Power The SPR receives, through its 15-pin D-type port, its power supply from the SDA. In turn, the SDA connects to an external power adapter from where it receives power. The SDA provides 48 VDC nominal power to the SPR (minimum of 30 VDC: maximum of 55 VDC). Warning: If you are using an external antenna, ensure that you connect the antenna before connecting the SPR to the power source.
9 Installing the SDA This chapter describes the installation of the WipLL Subscriber Data Adapter (SDA) at the subscriber's premises.
Installing the SDA Hardware Installation Guide 9.1. Overview The SDA is an Ethernet hub/LAN switch that provides the SPR with DC power, lightening protection, and Ethernet connectivity to the subscriber’s PCs/network. The SDA connects to the SPR by a CAT-5 cable. The SDA provides 10/100BaseT connectivity (depending on the SDA model) to the subscriber’s PCs or network (up to four PCs depending on the SDA model).
Hardw are Installation Guide Installing the SDA ! SDA-4S/VL: Provides VLANs between its ports and the SPR, ensuring privacy between users of different ports (i.e., multi-tenant VLAN security). For example, all users connected to Port 1 do not “see” users connected to Port 2. ! SDA-4S/VLtag: This model is ideal for multi-tenant applications where traffic engineering and privacy is required. SDA-4S/VLtag assigns the traffic from each of its four ports with a different VLAN ID.
Installing the SDA Hardware Installation Guide RF link CAT-5e Subscriber Premises Radio (SPR) located on the roof PC Subscriber Data Adapter (SDA) located inside Figure 9-1: Typical SPR and SDA location and connections at subscriber's premises 9-4 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SDA 9.2. Physical Dimensions and Basic Design The SDA is encased in a chassis. The chassis front panel provides access to the SDA’s communication ports. The left-side of the chassis provides a power connector port for connection to an external power adapter. The SDA’s bottom panel provides holes for mounting the SDA on a wall Figure 9-2 displays the SDA-4S models and the SDA-4H.
Installing the SDA Hardware Installation Guide Figure 9-3 displays the SDA-1 model. 15-Pin D-type port Power connector port RJ-45 port (10BaseT) Figure 9-3: SDA-1 (front, side, and top panels) The SDA’s physical dimensions are described in Table 9-1 Table 9-1: SDA physical dimensions Parameter 9-6 Value Height 200 mm (7.87 inches) Width 150 mm (5.9 inches) Depth 40 mm (1.57 inches) Weight 0.53 kg Airspan Networks Ltd.
Hardw are Installation Guide Installing the SDA 9.3. Mounting the SDA The SDA can be wall or desk mounted. 9.3.1. Desktop-Mounting For desk mounting (horizontal mounting), the chassis’ bottom panel provides four rubber feet on each corner. Warning: For desk mounting, do not place the SDA on a carpeted surface where airflow is restricted and a fire hazard may result. Mounting brackets Rubber feet Figure 9-4: SDA - rear panel 02030311-05 Airspan Networks Ltd.
Installing the SDA Hardware Installation Guide 9.3.2. Wall-Mounting For SDA wall mounting, two mounting hooks are molded into the chassis’ bottom panel (see Figure 9-4). The dimensions of the SDA’s wall-mounting hooks, located on the chassis bottom panel, are displayed in Figure 9-5.
Hardw are Installation Guide Installing the SDA 9.4. Connecting to the SPR The SDA’s 15-pin D-type port connects to the SPR’s 15-pin D-type port by a CAT5 cable. Note: For a detailed description on connecting the SDA to the SPR, see Chapter 8, “Installing the SPR”. 9.5. Connecting to the Subscriber’s Ethernet Network The SDA provides RJ-45 port(s) for Ethernet connectivity to the subscriber’s PCs/network. The number of Ethernet ports and the speed of the Ethernet connection depend on the SDA model.
Installing the SDA Hardware Installation Guide The following list describes the location of the Ethernet ports for the various SDA models: ! SDA-1: one RJ-45 port (see Figure 9-6) RJ-45 port Figure 9-6: SDA-1 with one Ethernet port ! SDA-4H: four RJ-45 ports (see Figure 9-7). Note: The left-most port (J5) is a crossover port.
Hardw are Installation Guide Installing the SDA ! SDA-4S models (SDA-4S, SDA-4S/VL, SDA-4S/Vltag, SDA-4S/1H3L, and SDA-4S/VL/1H3L): four 10/100BaseT RJ-45 ports. These ports support 10/100 Mbps autonegotiation, and MDI/MDI-X automatic crossover. This allows you to connect straight-through or crossover CAT-5 cables to these ports. 10/100BaseT RJ-45 ports Figure 9-8: SDA-4S RJ-45 Ethernet Ports 02030311-05 Airspan Networks Ltd.
Installing the SDA Hardware Installation Guide 9.5.1. Connecting to PCs The SDA connects to the subscriber’s PC(s) through the SDA’s Ethernet port (RJ-45). Note: To avoid electrical or fire hazard, ensure that the data connections to the SDA is made prior to connecting the power supply.
Hardw are Installation Guide Installing the SDA Figure 9-9: SDA-to-PC Cable Connections Note: The SDA-4S RJ-45 ports support MDI/MDI-X automatic crossover. This means that straight-through or crossover CAT-5 cables can be connected to these ports. 02030311-05 Airspan Networks Ltd.
Installing the SDA Hardware Installation Guide 9.5.2. Connecting to a Hub The SDA-4S models and SDA-4H can be connected to another hub (for example, for daisy chaining). The ports of the SDA-4S models support MDI/MDI-X automatic crossover, allowing connection of straight-through or crossover cables. However, for the SDA-4H model, only the left-most RJ-45 port (J5) is a crossover port (see Figure 9-7).
Hardw are Installation Guide Installing the SDA Figure 9-10: SDA-4H crossover cable connections to hub 02030311-05 Airspan Networks Ltd.
Installing the SDA Hardware Installation Guide Figure 9-11: SDA-4S crossover/straight-through cable connections to hub Note: The SDA-4S RJ-45 ports support MDI/MDI-X automatic crossover. Therefore, crossover CAT-5 cables can be connected to any of the ports. 9-16 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SDA 9.5.3. Connecting to a VoIP Network The SDA-4S/1H3L and SDA-4S/VL/1H3L model’s left-most RJ-45 Ethernet port assigns high priority to VoIP trafic. This port is used to connect to the subscriber’s VoIP network. This port assigns high priority to VoIP traffic, as opposed to the other RJ-45 ports, which assigns lower priority.
Installing the SDA Hardware Installation Guide Figure 9-12: Connecting VoIP RJ-45 Port (for SDA-4S/1H3L and SDA-4S/VL/1H3L) 9-18 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SDA 9.6. Connecting AC Power The SDA receives AC power by connecting to a standard 110–240 VAC wall outlet. In turn, the SDA provides 48 VDC nominal power to the SPR (minimum of 30 VDC: maximum of 55 VDC). Table 9-3 lists the SDA power supply specifications. Table 9-3: SDA Power Supply Specifications Power parameter Units Voltages 110-240 VAC Frequency 50/60 Hz Amps 0.3-0.7A The following lists the cable connection between the SDA and the power outlet:.
Installing the SDA Hardware Installation Guide Power port Figure 9-14: Location of SDA-1 power port Power port Figure 9-15: Location of SDA-4S model’s and SDA-4H power port 9-20 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SDA Warning: Ensure that plugs fitted to mains power leads for subscriber premises equipment are compatible with AC mains sockets. Do not replace plugs on power leads to suit local requirements without first verifying grounding practice for the country and equipment in question. Careful consideration must be given to issues including local wiring requirements, cable color-coding, safety grounding, and circuit protection requirements.
Installing the SDA Hardware Installation Guide Figure 9-16: SDA power cable connections 9-22 Airspan Networks Ltd.
Hardw are Installation Guide Installing the SDA 9.7. LED Display The SDA-4H and SDA-4S models provide LED indicators that indicate network connection, traffic status, and power. These LEDs are located on the top panel of the chassis. 9.7.1. SDA-4H Figure 9-17 displays the location of the SDA-4H LED indicators. Ethernet LEDs (2, 3, and 4) (straight-through) CROSS (5) LED UPLINK (1) LED POWER LED Figure 9-17: SDA-4H LED indicators 02030311-05 Airspan Networks Ltd.
Installing the SDA Hardware Installation Guide Table 9-4 describes the SDA-4H LED indicators.
Hardw are Installation Guide Installing the SDA 9.7.2. SDA-4S Models Table 9-5 describes the SDA-4S model’s LED indicators.
10 Installing the IDR This chapter describes the installation of the WipLL Indoor Data Radio (IDR), which is installed at the base station.
Installing the IDR Hardware Installation Guide 10.1. Overview The IDR device is an optional WipLL device that combines the functionality of the SPR and SDA devices. The IDR has a built-in antenna that provides an interface for transmission with the base station. In addition, the IDR provides an interface for 10Base-T Ethernet with the subscriber's network. However, unlike the SDA, a separate power supply unit (power adapter) powers the IDR.
Hardw are Installation Guide Installing the IDR Warning: To avoid electrical or fire hazard, ensure that all connections to the IDR are performed prior to connecting the power supply. Note: The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Installing the IDR Hardware Installation Guide 10.2. Physical Dimensions and Basic Design The IDR is encased in a chassis providing access to the IDR's communication port at the front panel. TNC-type connector for 3rd party external antenna Chassis cover bolt LEDs RJ-11 serial port RJ-45 10Base-T port Molex 6-pin power port Figure 10-2: IDR front panel with cover removed exposing ports The IDR's physical dimensions are described in Table 10-1.
Hardw are Installation Guide Installing the IDR 10.3. Mounting the IDR The IDR may be mounted in the following ways: ! Desk ! Pole ! Wall Note: Before mounting or attaching any brackets to the IDR, ensure that all cables are securely attached and that the unit functions correctly in the proposed location. 10.3.1. Desk Mounting The IDR may be mounted on a desk in one of the following ways: ! Vertically ! Horizontally 02030311-05 Airspan Networks Ltd.
Installing the IDR Hardware Installation Guide 10.3.1.1. Vertical-Desk Mounting A base plate is provided to mount the unit vertically on the desk, i.e., in standing position. The base plate is designed to fit in one position only. To desk mount the IDR in a vertical position: ! Insert the IDR into the base and press firmly until the tabs click into place. See Figure 10-3. Deskmounting plate Figure 10-3: IDR vertical desk mounting 10-6 Airspan Networks Ltd.
Hardw are Installation Guide Installing the IDR 10.3.1.2. Horizontal-Desk Mounting To position the IDR horizontally on the desk, four rubber pads, supplied with the unit, must be fitted to avoid damage to mounting surfaces. mTo desk mount the IDR in a horizontal position: ! Secure the rubber pads to the posts provided on the rear of the IDR using four self-tapping screws. See Figure 10-4.
Installing the IDR Hardware Installation Guide 10.3.2. Wall and Pole Mounting The IDR may be mounted to a wall or to a 5-cm diameter pole. Wall and pole mounting both use the same mounting brackets and wall hanger plate. 10.3.2.1. Assembling the Bracket and Hanger Plate The wall hanger plate secures the IDR to a wall or pole. The wall bracket and hanger plate allows positioning the IDR in the correct orientation.
Hardw are Installation Guide Installing the IDR 4. Attach the wall bracket assembly to wall hanger using an M4 socket-head bolt and nut as shown in Figure 10-6. The bolt is only to be hand tightened at this stage. Wall Hanger M-4 nut Screw Mounting bracket assembly Figure 10-6: Wall hanger fixing method Figure 10-7: Wall hanger & mounting bracket assembly 02030311-05 Airspan Networks Ltd.
Installing the IDR Hardware Installation Guide 5. Once assembled, the IDR mounting bracket assembly may be secured to the rear of the IDR using the 4-off self-tapping screws supplied in the unit fixing kit. See Figure 10-8. Self tapping Screws Figure 10-8: Mounting bracket assembly secured to IDR 10-10 Airspan Networks Ltd.
Hardw are Installation Guide Installing the IDR 10.3.2.2. Pole Mounting Prior to mounting the IDR to a pole the wall mounting bracket assembly must be fitted as described in the previous section. To pole mount the IDR: 1. Offer up the IDR assembly to the pole as shown in Figure 10-9. 2. Insert 2-off M10 bolts through the holes in the wall hanger. 3. Slide the clamp-holder into position and secure using washers, spring-washers and nuts as illustrated in Figure 10-10. Finger-tighten the fasteners. 4.
Installing the IDR Hardware Installation Guide Figure 10-10: IDR secured to a pole To set the correct IDR inclination: 1. Loosen the 2-off M4 socket head screws on the mounting bracket tilt-arm 2. Position the IDR at the desired angle. 3. Re-tighten the 2 off socket screws on the tilt arm. 10-12 Airspan Networks Ltd.
Hardw are Installation Guide Installing the IDR 10.3.2.3. Wall Mounting Warning: Prior to drilling holes in a wall ensure that there are no hidden services such as electricity cables or water pipes. A stop must be used on the power drill to ensure that bored holes do not exceed 35 mm. To mount the IDR on a wall: 1. Loosen the 2-off M4 socket head screws on the mounting bracket tilt-arm and remove the wall hanger. 2. Offer up the wall hanger to the wall and scribe through the mounting hole locations. 3.
Installing the IDR Hardware Installation Guide 10.4. Connecting a Third-Party External Antenna The IDR provides a TNC-type connector for connecting a third-party antenna to the IDR. This antenna can be placed on the subscriber’s windowsill to provide better RF signal reception with the BSR. Note: Airspan supplies unterminated cables for N-type connectors. Therefore, refer to the cable crimping procedures for N-type connectors detailed in Appendix B, “Cable Crimping".
Hardw are Installation Guide Installing the IDR Figure 10-11: Connecting a third-party antenna Warning: It is the responsibility of the person installing the WipLL system to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), that only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance with FCC rules CFR47 part 15.204.
Installing the IDR Hardware Installation Guide 10.5. Connecting to an Ethernet Network The IDR provides one Ethernet interface for the subscriber’s Ethernet network. This port is located on the front panel, and labeled Ethernet. ! Connector: 8-Pin RJ-45 ! Cable: CAT-5 ! Connector pinouts: Pin 1 2 3 4 5 6 7 8 Function Rx+ RxTx+ Not Connected Not Connected TxNot connected Not connected To connect IDR to the subscriber’s Ethernet network: 1.
Hardw are Installation Guide Installing the IDR Figure 10-12: Connecting IDR to a client PC 02030311-05 Airspan Networks Ltd.
Installing the IDR Hardware Installation Guide 10.5.1. Ethernet LED Indicator The IDR provides one LED that indicates an Ethernet connection. This LED is labeled Ethernet and is located on the IDR’s top panel. Table 10-2: Description of Ethernet LEDs LED Ethernet Color Orange Status Indicates On Physical link between IDR and Ethernet network Off No physical link between IDR and Ethernet network Blinking Data is flowing through the Ethernet port 10.6.
Hardw are Installation Guide Installing the IDR Figure 10-13: IDR LED indicators To position the IDR for optimum RF signal: ! Position the IDR until all three RF signaling strength indicator LEDs are lit. Refer to Section 10.3.2, “Wall and Pole Mounting” page 10-8 for details on adjusting IDR wall and pole mounting position. For desk-top mounting, the IDR can be simply relocated to obtain the strongest signal. 02030311-05 Airspan Networks Ltd.
Installing the IDR Hardware Installation Guide 10.7. Connecting to PC for Serial Configuration To perform IDR initial configuration, you need to connect the IDR’s RJ-11 port to the serial port of a PC running the WipLL network management application (i.e., WipConfig). The IDR’s RJ-11 port labeled Serial, located on the front panel, connects to the serial port of a PC via a cable with an RJ-11 connector on the one end, and a 9-Pin D-type connector on the other (i.e., a direct serial cable connection-DCC).
Hardw are Installation Guide Installing the IDR ! Connector pinouts: Crossover cable Straight-through cable 6-Pin RJ-11 Pin 1 2 3 4 5 6 Function Rx Not connected NC NC GND Tx 2 5 3 - 9-Pin D-type female 9-Pin D-type male 9-Pin D-type male Pin Pin Pin 4 1 3 - 3 5 2 - To connect the IDR to the WipLL management station (PC): 1. Connect the 6-Pin RJ-11 connector to the IDR’s RJ-11 port (labeled Serial) located on the IDR’s front panel (see Figure 10-14). 2.
Installing the IDR Hardware Installation Guide Figure 10-14: IDR-to-PC Serial Cable Connections 10-22 Airspan Networks Ltd.
Hardw are Installation Guide Installing the IDR 10.8. Connecting Power The IDR is powered by an external power supply (Triple Output External Adapter). The IDR connects to the power adapter via the IDR's power port located on the IDR’s front panel.
Installing the IDR Hardware Installation Guide ! There is no physical sign of damage to the power outlet. ! There should not be any visible sign of water or dampness on or around the power outlet. ! The plug and socket assemblies are to be firmly secured. ! The power outlet shall be checked using a proprietary plug tester such as a ‘Martindale Ze’ type. Checks are required to verify the earth loop impedance value and the presence of phase, neutral and earth connections.
Hardw are Installation Guide Installing the IDR Figure 10-15: Connecting power to the IDR 02030311-05 Airspan Networks Ltd.
Installing the IDR Hardware Installation Guide 10.8.1. Power LEDs The IDA provides a power LED indicator, labeled Power, which indicates whether a power supply exists. The Power LED is located on the front panel of the IDR chassis. Table 10-5: Description of Power LEDs LED Power 10-26 Color Red Status Meaning On The SDA receives power supply Off No power received Airspan Networks Ltd.
A Glossary AC Alternating Current BNC Bayonet Neill Concelman (Connector type) BSDU Base Station Distribution Unit BSPS Base Station Power System BSR Base Station Radio CEP Common Earth Point DC Direct Current DCC Direct Serial Cable Connection GPS Global Positioning Satellite HSP Hop Synchronisation Process HSPP Hop Synchronisation Process Pulse IDR Indoor Data Radio IP Internet Protocol LED Light Emitting Diode mA Milliamperes MCB Miniature Circuit Breaker Mbps Mega Bits P
Glossary Hardware Installation Guide SDA Subscriber Data Adaptor SME Small and Medium Enterprises SOHO Small Office/Home Office SPR Subscriber Premises Radio UPS Un-interrupted Power Supply UPVC Unplasticized Poly-Vinyl Chloride WAN Wide Area Network WipLL Wireless internet protocol -Local Loop A-2 Airspan Networks Ltd.
B Cable Crimping This chapter describes the procedure for crimping cables for 15-Pin D-type and Ntype connectors that are used in BSR/SPR-to-BSDU/SDA and BSR-to-GPS connections, respectively. The opposite ends of these cables are un-terminated, thereby providing length flexibility for connecting these WipLL units.
Cable Crimping Hardware Installation Guide B.1. Crimping CAT-5e Cable for 15-Pin D-Type Connectors This section describes the cable stripping and crimping of CAT-5e cables for 15-Pin D-type connectors used for BSR/SPR-to-BSDU/SDA connections. Airspan recommends the "ITT Canon DB15" (code number ‘DAW15P’) subminiature type. This connector is an Insulation Displacement Connector (IDC) which crimps and secures the cable at the connection point.
Hardw are Installation Guide Cable Crimping The major features of the crimper are described in the following table: Table B-1: Main features of crimping tool Tool feature Terminating Head Wire Inserter Function Guides and supports the connector. • Cuts wire to be terminated. • Forces conductors into 2 slotted beams of the contact. Anti-backup locator Prevents connector from moving out of position for accurate termination. Feed Slide Automatically advances the connector after each termination.
Cable Crimping Hardware Installation Guide B.1.1. Stripping the Cable Before crimping the cables, you need to strip 50 mm of the cable. Before using the tool, ensure that the tool is correctly adjusted. Correct adjustment is obtained when the blade cuts the outer insulation without damage to the insulation of inner conductors. To strip the cable: 1. Cut the cable to length using cable shears (Airspan code 1PAC10333AKJ). 2. Strip 50 mm of the sheathing using stripping tool. 3.
Hardw are Installation Guide Cable Crimping 5. Use a steel rule (1PAC10042AAV) to verify the stripped dimension. 6. Inspect the cut for evidence of damage, i.e. has the braid been cut? If so cut off cable and reset tool. B.1.2. Crimping the Cable Once you have stripped 50 mm of the cable, you can begin crimping the cable to the 15-Pin D-type connector. Note: For 15-Pin D-type connector pinouts, see the relevant chapter on the specific WipLL equipment. To crimp the cable: 1.
Cable Crimping Hardware Installation Guide Wire Slot Connector advances in this direction Figure B-3: Crimping tool 8. When finished, remove the connector from the right side of connector slot. Note: The connector must be inserted into the crimper from the left hand side only. Should the connector jam in the terminating position, excessive force must not be used: the spigot between the tool handles should be used to release the ratchet mechanism.
Hardw are Installation Guide Cable Crimping Note: The purpose of the barrel is to prevent the wire from being lifted from the contact. It is not necessary to have the barrel wrapped tightly around the insulation. ! Ensure that the contact cavity has not been deformed ! Confirm integrity by holding the connector in one hand and pulling lightly on the cable. Figure B-4 shows points to be observed during quality inspection. Correct Termination 0.
Cable Crimping Hardware Installation Guide B.1.4. Housing the Connector For outdoor cable installations, the connector is to be protected in a waterproof housing assembly as shown in Figure B-5. Note: The housing, cable seal, and clamping nut are to be slid onto the cable prior to crimping the connector in place. To assemble the connector in a waterproof housing: 1. Insert the connector into the waterproof housing ensuring that a "click" is heard. 2.
Hardw are Installation Guide Cable Crimping To assemble the un-housed connector: 1. Insert the connector terminal block into the connector body. 2. Secure the cable onto the connector body using the cable clamp. Ensure that the cable outer sheath is within the connector body. 3. Snap the top section of the connector body into place. 4. Ensure that the connector is secure within the housing by applying a light pull on the cable. 02030311-05 Airspan Networks Ltd.
Cable Crimping Hardware Installation Guide B.2. Crimping N-type Connectors This section describes the cable stripping and crimping Multipair Overall Shielded (22 AWG) cables for N-type connectors used for BSR/SPR connections to external antennas. Airspan recommends using the following tools for crimping of N-type connectors: ! Crimp tool: Erma 29020 with die set 29207. ! Stripping tool: Maxi Corex, fitted with the 9.0 to 11.5mm cable clamp (blue) and the 9.5 to 3.2 blade cassette (green). B.2.1.
Hardw are Installation Guide Cable Crimping 7. Clamp the tool around the cable and lock in position. 8. Holding the cable in the left hand and stripping tool in the right hand (index finger through finger hole) rotate tool in a clockwise direction for 10 turns. 9. Move slide mechanism to number 3. 10. Rotate tool in a clockwise direction for 10 turns. 11. Move slide mechanism to number 1. 12. Rotate tool in a clockwise direction for 10 turns. 13. Unlock the tool to remove cable then lock shut.
Cable Crimping Hardware Installation Guide B.2.2. Assembling the Connector Once you have stripped the cable, you can house the cable: To house the cable: 1. Fit an insulating boot if required, over the cable, cutting enough of the pointed end to enable the cable to go through the resulting hole with a fairly tight grip. Push ferrule over the stripped section of cable. 2.
Hardw are Installation Guide Cable Crimping 3. Trim the centre conductor back to 5.5 mm from the end of the dielectric. Use the cable shears provided and not the side cutters. 4. Fit centre pin on to the centre conductor. The centre conductor should be seen through the inspection hole (see Figure B-7). Ensure that the shoulder of the pin is butted up to the cable’s dielectric. Figure B-7: Fitting center pin onto center conductor B.2.3. Crimping To crimp the GPS connector: 1.
Cable Crimping Hardware Installation Guide 5. Crimp the ferrule using the large aperture of the 29207 die. When offering up the tool the die should be positioned so as it aligns with the braid and not the outer sheath of the cable. 6. Connectors with nylon washers, the crimp is to be made with the dies held firmly against the washers face. B-14 Airspan Networks Ltd.
Hardw are Installation Guide Cable Crimping B.3. Crimping GPS Cable Connectors Airspan recommends the following tools for crimping for N-type connectors: ! Crimping tool—Daniels AFM8 (M22520/2-01). Figure B-8: Crimping tool – Daniels AFM8 Once you have housed the stripped cable, you can now crimp the cable to an N-type connector. Note: The crimper cannot be opened without completing the cycle. To crimp the cable: 1. Ensure that the crimper is in the open position. 2.
Cable Crimping Hardware Installation Guide 6. Insert the contact and prepared cable into the indenter opening from the side opposite the Positioner. 7. Squeeze crimper handles together until the ratchet releases. The handle will return to the open position. 8. Remove crimped contact and cable. B-16 Airspan Networks Ltd.
C Technical Specifications This appendix lists the technical specifications for the following WipLL units: ! WipLL Base Station equipment: ! Base Station Radio (BSR) ! Point-to-Point Radio (PPR) ! Base Station Distribution Unit (BSDU) ! Base Station Power Supply (BSPS) ! GPS antenna ! WipLL Customer premises equipment: ! Subscriber Premises Radio (SPR) ! Subscriber Data Adapter (SDA) ! − SDA-1 − SDA-4H − SDA-4S models Indoor Data Radio (IDR) 02030311-05 Airspan Networks Ltd.
Technical Specifications Hardware Installation Guide C.1. Base Station WipLL Equipment The following sub-sections list the specifications of the following WipLL Base Station equipment: ! Base Station Radio (BSR) ! Point-to-Point Radio (PPR) ! Base Station Distribution Unit (BSDU) ! Base Station Power Supply (BSPS) C-2 Airspan Networks Ltd.
Hardw are Installation Guide Technical Specifications C.1.1. Base Station Radio (BSR) Table C-1: BSR and MAC Specifications Parameter Operating frequency range Value Comment • 2.4 GHz • ISM band • 3.x GHz, MMDS, 2.8 GHz • Licensed band • 5.8 GHz • Unlicensed band • 900 MHz • Unlicensed band *Other ranges available for trial Spectrum spreading method Frequency hopping Duplex method • Time Division Duplex (TDD) - 2.4 GHz, 2.8 GHz, 3.x GHz, MMDS, 900 MHz, and 5.
Technical Specifications Hardware Installation Guide Table C-2: BSR EMC and Radio Standards Compliance Parameter Value Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec • ETSI ETS 300 826 EMC • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 Table C-3: BSR Agency Certification Parameter Value Emissions / Immunity EN 300 339 EN 300 386-2 ETS 300 328 Safety EN / IEC 60950 Environmental ETS 300 019-2-x Table C-4: BSR Network S
Hardw are Installation Guide Technical Specifications Table C-6: BSR Environmental Conditions Parameter Value Operating temperature of outdoor units (BSR and SPR) -30ºC to +60ºC Storage temperature -40ºC to +80ºC Comment Optional range of -40ºC to +70ºC Table C-7: BSR Network Interface Parameter Value Ethernet Network UTP EIA/TIA Standards Compliance ANSI/IEEE 802.
Technical Specifications Hardware Installation Guide C.1.2. Point-to-Point Radio (PPR) Table C-9: PPR Radio Specifications Parameter Operating frequency bands Value • 2,400 to 2,500 MHz • 3,400 to 3,800 MHz • 5,725 to 5,875 MHz Duplex method • Time Division Duplex (TDD) for all bands • Frequency Division Duplex (FDD) for 3.4 to 3.
Hardw are Installation Guide Technical Specifications C.1.3.
Technical Specifications Hardware Installation Guide C.1.4. Base Station Power Supply (BSPS) Table C-15: BSPS Rectifier Specifications Parameter Input Output General Value Voltage 90VAC to 270VAC Current (nominal) 3.2A @ 230V / 4.3A @ 115V Frequency 47Hz to 63Hz Power factor (nominal line/load) Greater or equal to 0.993 Voltage (default) 53.5VDC Regulation (line & load) ±0.
Hardw are Installation Guide Technical Specifications Table C-16: BSPS DC Distribution Specifications Parameter Input Output General 02030311-05 Value Voltage 90VAC to 270VAC Current (at full load) N =Number of rectifier modules • N*3.2A @ 230V Frequency 47 Hz to 63 Hz Power factor (at full load) Greater or equal to 0.993 Voltage (programmable) 42 to 60VDC ± 0.5VDC Default float and boost voltage 54 and 57VDC respectively Regulation (line, load, sharing) ±1% Current N*12A (48A max.
Technical Specifications Hardware Installation Guide Parameter EMC Value According to: • EN300-386-2 SUB 7.2.3 • EN55022 class B • IEC1000-4-2 • IEC1000-4-3 • IEC1000-4-4 • IEC1000-4-5 • IEC1000-4-6 • IEC1000-4-11 • IEC1000-3-2 • IEC1000-3-3 LVLD (optional) C-10 Safety According to: IEC950 Maximum current withstand 2x70A Trip voltage level Disconnect default: 43± 0.5 VDC, user programmable Re-connect: with AC recovery Airspan Networks Ltd.
Hardw are Installation Guide Technical Specifications C.1.5. GPS antenna Table C-17: SPR Power Requirements Parameter Value Voltage Input 36 VDC Consumption 1.
Technical Specifications Hardware Installation Guide C.2. Customer Premises WipLL Equipment The following sub-sections list the specifications of the following WipLL CPE equipment: ! Subscriber Premises Radio (SPR) ! Subscriber Data Adapter (SDA) ! Indoor Data Radio (IDR) C.2.1. Subscriber Premises Radio (SPR) Table C-21: SPR and MAC Specifications Parameter Value Comment • 2.4 GHz • ISM band • 3.x GHz, 2.8 GHz, MMDS • Licensed band • 5.
Hardw are Installation Guide Technical Specifications Table C-22: SPR EMC and Radio Standards Compliance Parameter Value Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec • ETSI ETS 300 826 EMC • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 Table C-23: SPR Agency Certification Parameter Value Emissions / Immunity EN 300 339, EN 300 386-2, ETS 300 328 Safety EN/IEC 60950 Environmental ETS 300 019-2-x Comment Table C-24:
Technical Specifications Hardware Installation Guide Table C-26: Environmental Considerations Parameter Value Operating temperature -30ºC to +60ºC Storage temperature -40ºC to +80ºC Table C-27: Network Interface Parameter Value Ethernet Network UTP EIA / TIA Standards Compliance ANSI/IEEE 802.3 and ISO/IEC 8802-3; 10BaseT compliant Serial Port RS-232 Comment Category 5 Table C-28: SPR Physical Dimensions (w/o High Gain Antenna) Parameter Value Height 311 mm (12.
Hardw are Installation Guide Technical Specifications C.2.2. Subscriber Data Adapter (SDA) C.2.2.1. SDA-1 Table C-30: SDA-1 Physical Dimensions Parameter Value Height 200 mm Width 150 mm Depth 40 mm Weight 47 kg Table C-31: SDA Power Requirements Parameter Value Output Voltage -48VDC nominal Power supply 110-240 VAC, 50/60Hz, 0.3-0.
Technical Specifications Hardware Installation Guide C.2.2.2. SDA-4H Table C-34: SDA-4-H Physical Dimensions Parameter Value Height 200mm Width 150mm Depth 40mm Weight 53 kg Table C-35: SDA-4H Power Requirements Parameter Value Output Voltage -48VDC nominal Power supply 110-240 VAC, 50/60Hz, 0.3-0.
Hardw are Installation Guide Technical Specifications C.2.2.3. SDA-4S Models Table C-38: SDA-4S Physical Dimensions Parameter Value Height 200 mm (7.87 inches) Width 150 mm (5.9 inches) Depth 40 mm (1.57 inches) Weight 53 kg Table C-39: SDA-4S Power Requirements Parameter Value Output Voltage -48VDC nominal Power supply 110-240 VAC, 50/60 Hz, 0.3-0.
Technical Specifications Hardware Installation Guide C.2.3. Indoor Data Radio (IDR) Table C-42: IDR Radio and MAC Specifications Parameter Operating frequency Value Comment • 2.4 GHz • 3.45 GHz • 3.5 GHz • 900 MHz Spectrum spreading method Frequency hopping Duplex Method • Time Division Duplex (TDD) at 2.4 GHz and 900 MHz (Per ETSI ETS 300 328) ARIB-STD-T66 • Frequency Division Duplex (FDD) at 3.5 GHz and 3.
Hardw are Installation Guide Technical Specifications Table C-43: IDR EMC and Radio Standards Compliance Parameter Value Radio Standards Compliance • ETSI EN 300 328-1 • ETSI EN 301 253 • FCC part 15 • RSS139 • Telec • ETSI ETS 300 826 EMC • ETSI EN 300 385 • ETSI EN 300 386-2 • ETSI ETS 300 132-2 • FCC part 15 Table C-44: IDR Agency Certification Parameter Value • VCCI Class A Emissions / Immunity • ARIB-STD-T66 • ETSI 300 386-2 Safety EN/IEC 60950 Environmental ETS 300 019-2-x Table C-45: I
Technical Specifications Hardware Installation Guide Table C-47: IDR Environmental Considerations Parameter Value Operating temperature 0-50ºC Operating Humidity +30Cº 93% Storage temperature -40 – 70ºC Comment Maximum humidity Table C-48: IDR Network Interface Parameter Value Ethernet Network UTP EIA / TIA Standards Compliance ANSI/IEEE 802.
D Summary of Connector Pinouts This appendix provides a summary of the connector pinouts for the WipLL devices. D.1. BSR/SPR-to-BSDU/SDA CAT 5 Connector Pinouts Table D-1 describes the 15-pin D-type connector pinouts for the CAT 5 cable that connects the BSR's/SPR's 15-pin D-type port to the BSDU's/SDA's 15-pin D-type port.
Summary of Connector Pinouts Hardware Installation Guide Notes: - Pins 9 through 15 of the 15-pin D-type connector are not used. - The wire color-coding described in the table is WipLL's standard for wire color-coding. However, if you implement your company's wire color-coding scheme, ensure that the wires are paired and twisted according to the pin functions listed in Table D-1 (e.g., Rx+ with Rx-).
Hardw are Installation Guide Summary of Connector Pinouts D.2. SPR Serial Connector Pinouts For BSR and SPR serial connections, a Y-cable is used. The Y-cable connects the BSR and SPR to the BSDU and SDA, respectively, as well as to the PC running the WipLL management application. Figure D-2 displays the Y-cable used to split the BSR/SPR 15-pin D-type port into two.
Summary of Connector Pinouts Hardware Installation Guide Table D-3: Y-cable SPR-to-PC connector pinouts Straight-through Y-cable SPR 15-pin D-type male Pin PC Function Pin Function 12 GND 5 GND 14 RS232 Rx 3 Rx 15 RS232 Tx 2 Tx 9-pin D-type female The Y-cable connector pin assignments are displayed shematically in Figure D-3. Figure D-3: Y-cable connector pin assignment D-4 Airspan Networks Ltd.
Hardw are Installation Guide Summary of Connector Pinouts D.3. BSR Serial Connector Pinouts The BSR provides a serial port for RS-232 serial interface to a PC. This serial communication connection allows you to perform BSR initial configuration.
Summary of Connector Pinouts Hardware Installation Guide D.4. BSDU Connector Pinouts D.4.1. BSDU Daisy Chaining Table D-5: BSDU daisy chaining connector pinouts Crossover cable 8-pin RJ-45 Pin Description 8-pin RJ-45 Name Pin 1 Tx+ Transmit Data+ 3 2 Tx- Transmit Data- 6 3 Rx+ Receive Data+ 1 6 Rx- Receive Data- 2 D.4.2.
Hardw are Installation Guide Summary of Connector Pinouts ! Sync OUT Table D-7: BSDU synchronization (Sync OUT) connector pinouts Straight-through cable 8-pin RJ-45 male Pin Name Description 1 TD+ Transmit data to GPS 2 TD- Transmit data from GPS 3 Tx+ Transmit Data (hop synchronization) 4 RD+ Receive Data (from GPS) 5 RD- Receive Data (to GPS) 6 Tx- Transmit Data (hop synchronization) 7 1PPS+ GPS pulse per second 8 1PPS- GPS pulse per second D.4.3.
Summary of Connector Pinouts Hardware Installation Guide D.4.4. BSDU PC Network Management For BSDU network management, you can connect the BSDU’s two 10BaseT ports (i.e., loop the ports) to one another by a crossover cable, then connect the PC to one of the BSDU’s 100BaseT ports. If the two BSDU 10BaseT ports are not connected to one another, then you need to connect the PC to the BSDU’s right-most 10BaseT port (labeled 10Base-T 2).
Hardw are Installation Guide Summary of Connector Pinouts D.4.5. BSDU 100Base-T Table D-11: BSDU 100Base-T LAN/WAN connector pinouts Straight-through cable 8-pin RJ-45 Pin Name Description 1 Tx+ Transmit Data+ 2 Tx- Transmit Data- 3 Rx+ Receive Data+ 6 Rx- Receive Data- D.5. GPS-to-BSDU Connector Pinouts The following table lists the connector pinouts for the cable connecting the GPS antenna to the BSDU.
Summary of Connector Pinouts Hardware Installation Guide D.6. Connector Pinouts for BSPS Serial Management via BSDU Table D-13: BSPS serial management connector pinouts BSDU 9-pin D-type female BSPS Pin Function Pin Function 2 Rx 6 Tx 3 Tx 3 Rx 5 GND 5 GND 8-pin RJ-45 D.7. IDR Connector Pinouts D.7.1. Serial Management Connection Serial connection of the IDR to a PC is performed by connecting the IDR's RJ-11 port to the serial port (9-pin D-type) of the PC.
Hardw are Installation Guide Summary of Connector Pinouts D.7.2. Ethernet LAN Connection The table below describes the connector pinouts for the Ethernet cable (CAT 5) that connects the IDR’s Ethernet port to the PC’s LAN port, using an 8-pin RJ-45 connector. Table D-15: BSPS Ethernet LAN connector pinouts 8-pin RJ-45 Pin 1 2 3 6 02030311-05 Function Rx+ RxTx+ Tx- Airspan Networks Ltd.
Summary of Connector Pinouts Hardware Installation Guide D.8. SDA Ethernet LAN Connector Pinouts ! For SDA-1, SDA-4H (J2, J3, J4), and SDA-4S models (also for VoIP networks): Table D-16: SDA Ethernet LAN connector pinouts Straight-through cable 8-pin RJ-45 male Pin 1 2 3 6 ! Function +RX -RX +TX -TX For J5 port on the SDA-4H: Table D-17: SDA Ethernet LAN connector pinouts Crossover cable 8-pin RJ-45 male Pin 1 2 3 6 D-12 Function +Tx -Tx +Rx -Rx Airspan Networks Ltd.