AirHarmony‐4200 DC Installation Guide Internal Filters Part Number: UGD-D01196
AirSynergy3 Equipment Installation Guide System Release: 16.
© Copyright by Airspan Networks Ltd., 2018‐2019. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary, privileged and intended only for the recipient. As such, the information is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Ltd. rights in the aforesaid information.
Table of Contents Document Information ....................................................................................... 1 Abstract ................................................................................................................................. 1 Revision History ..................................................................................................................... 1 Warnings and Cautions ..................................................................................
AirHarmony‐4200 DC (Internal Filters) Installation Guide Antenna System .................................................................................................................. 13 External Antenna ................................................................................................................. 13 About This Document ....................................................................................... 15 Purpose ...................................................................
AirHarmony‐4200 DC (Internal Filters) Installation Guide 4.1 Connecting the GPS Antenna ...................................................................................... 29 4.2 Pole/Wall Mount Assembly ......................................................................................... 30 Mounting on a Pole ................................................................................................................ 30 Mounting on a Wooden Pole ..................................................
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 6: Attaching GPS antenna to unit............................................................................................... 29 Figure 7: Pole/Wall mounting plate (w/o bolt) ..................................................................................... 30 Figure 8: Mounting plate mounted ....................................................................................................... 32 Figure 9: Pole/Wall mounting plate ......
AirHarmony‐4200 DC (Internal Filters) Installation Guide Document Information Abstract This document details procedures for installing the Airspan’s AirHarmony‐4200 DC, with internal filters, a mini‐Macro class eNodeB variant and its place in the Airspan product suite. This document is intended for qualified personnel with a working knowledge of LTE. Revision History Revision Details Date Summary of Changes Rev 0.1, 0.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The AirHarmony‐4200 DC Internal Filters antennas should be operated from a minimum safe distance of 90 Cm (35.43 inches). Radio Interference The AirHarmony‐4200 DC Internal Filters generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
AirHarmony‐4200 DC (Internal Filters) Installation Guide L’équipement ne peut pas être vendu en grande distribution ou par commande via email à destination du public. Il doit être vendu aux opérateurs de télécommunications. Son installation doit être contrôlée Son Installation doit être effectuée par des professionnels autorises selon FCC 96.39. Son installation requiert une formation spécifique du personnel.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Safety 1. Read this guide and follow all operating and safety instructions. 2. Keep all product information for future reference. 3. Static sensitive components inside ‐ do not remove the lid or base: No user serviceable parts inside. 4. Position the power cord to avoid possible damage, do not overload circuits. 5. Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 6.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 8. L’unité ne doit pas être située trop près de lignes électriques ou autres circuits de puissance, avec lesquels il pourrait entrer en contact. 9. L’émetteur radio doit être correctement relie a la terre afin de le protéger contre les surtensions ou accumulation d’électricité statique. L’utilisateur est tenu responsable de l’installation du produit conformément aux règles électrique en vigueur localement. 10.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Adherence to European Directive 2014/53/EU European Council Recommendation 2014/53/EU details basic restrictions and reference levels on human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these recommended restrictions and reference levels should provide a high level of protection as regards the established health effects that may result from exposure to electromagnetic fields.
AirHarmony‐4200 DC (Internal Filters) Installation Guide UL Information ‐ The equipment must be properly grounded according with NEC and other local safety code requirements. ‐ Reminder to all the BWA system installers: Attention to Section 820‐40 of the NEC which provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as is practical.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Outdoor Ethernet Cabling ‐ Ethernet cable connected to should be outdoor grade with UV protection. ‐ Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors. ‐ In order to protect the indoor unit, install surge protection circuits on all copper cables on their entrance to the building. ‐ Surge protection circuit must use a minimum 16AWG grounding cable.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Con la presente Airspan dichiara che questa unità è conforme ai requisiti essenziali e alle altre disposizioni pertinenti stabilite dalla direttiva 2014/53 / UE. Latvian: Ar šo Airspan paziņo, ka vienība atbilst Direktīvas 2014/53 / ES būtiskajām prasībām un citiem attiecīgajiem noteikumiem; Lithuanian: Šis „Airspan“ pareiškia, kad šis įrenginys atitinka esminius Direktyvos 2014/53 / ES reikalavimus ir kitas nuostatas.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Airspan lýsir hér með yfir að þessi eining uppfylli grunnkröfur og aðrar kröfur tilskipunar 2014/53 / ESB. Norsk: Airspan erklærer herved at utstyrsenheten oppfyller grunnleggende krav og andre relevante krav i direktiv 2014/53 / EU. Român: Airspan declarăm pe propria răspundere că produsul produsului respectă cerințele esențiale și alte prevederi aplicabile din Directiva 2014/53 / UE.
AirHarmony‐4200 DC (Internal Filters) Installation Guide GPS Compliance The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Power Consumption - Supply and Current AirHarmony‐4200 DC Internal Filters supports direct connection to DC power source. DC Power Source requirements are: Operational Voltage Range: ‐40.5 to ‐57 VDC Max, 8A Max Safety approved (certified) according to IEC/EN/UL 60950‐1 Transient Voltage: +150V (ETR283) The use of other power sources may impair safety AC power feed is also available, using an AC/DC power converter offered by Airspan.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Antenna System AirHarmony‐4200 DC comes in a range of frequency variants that can be mounted with different antenna options and formats. A typical installation will have a cross‐polar sector or dual slant antenna connected to the approprate RF port of the AirHarmony‐4200 DC variant unit. Various antennas are designed specifically for AirHarmony‐4200 DC deployments; specifications are available from Airspan separately.
AirHarmony‐4200 DC (Internal Filters) Installation Guide UGD‐D01196 Airspan Commercial and Internal Use 14
AirHarmony‐4200 DC (Internal Filters) Installation Guide About This Document Purpose This guide provides the workflow and step‐by‐step procedures for installing the Airspan’s AirHarmony‐4200 DC Internal Filters Macro‐class eNodeB variant.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Convention Element Warning Signifies a hazardous situation—if not avoided—can cause death or serious personal injury. Describes how to avoid it. Caution Signifies a hazardous situation—if not avoided—can void the product warranty, and cause property damage. Describes how to avoid it. Important Provides necessary information to explain a task. Note Provides additional information. Tip Provides helpful hints.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e‐mails to Customer Care Help Desk.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirHarmony‐4200 DC Internal Filters a Macro‐class eNodeB variant and its place in the Airspan product suite. This document is intended for readers with LTE working knowledge. All information in this document is for general information only, and is subject for change without notice. 1.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 1.2 Deployment A highly flexible and scalable 4G Base Station, the AirHarmony‐4200 DC Internal Filters is capable of supporting LTE profiles across multiple frequency bands. Note: AirHarmony‐4200 DC Internal Filters must be properly grounded (16AWG minimum) according to NEC and other local safety code requirements. Warning: Required ‐ circuit breaker for AC power source (when used) ‐16A for EU installation and 20A for US installation.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 1.3 Related AirHarmony 4200 DC Internal Filters Variants This document is related to AirHarmony 4200 DC Internal Filters variants. The following table lists the relevant variants: Table 6: AirHarmony 4200 DC Variants Band Product Code 42 Description DL Freq. UL Freq. Duplex Max Channel Dual Tx/Rx Filters/ (MHz) (MHz) Mode BW (MHz) Carrier Conf.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 2 Getting Started 2.1 Workflow of Installation The Workflow to install the AirHarmony‐4200 DC Internal Filters is displayed in the following diagram: Figure 3: Workflow Caution: Antennas must be connected and attached before AirHarmony‐4200 DC Internal Filters unit is powered on.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 2.2 AirHarmony-4200 DC Internal Filters Installation Checklist Plan the installation of the AirHarmony‐4200 DC by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide. 3 Verifying Prerequisites Prior to installing the AirHarmony‐4200 DC Internal Filter unit, verify the required safety, power, tools, parts and components.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Verify the Parts and Kits Note: Verify your order and requirements to ensure the correct unit type is being installed. Table 8. Parts & Kits Installation Kit / Part Part No. Airspan No. Consisting of: AirHarmony 4200 3.5GHz (B42) HAR42‐CN‐ U42‐B06DP TBD AirHarmony 4200 3400 ‐ 3600MHz (B42), Connectorized w Internal Filters 2x Fiber + 2x Copper, PoE, DC AirHarmony 4200 3.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Installation Kit / Part Part No. Airspan No. Consisting of: Type‐IC DC Power Cable ‐ 50m ‐ special order Type‐IC DC Power Cable ‐ 75m ‐ special order PWR‐50‐INST‐2 N/A Type‐IC DC Power Cable PWR‐75‐INST‐2 N/A Type‐IC DC Power Cable Image Full AXS SM Fiber Cable Full AXS SM Fiber Cable 5m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 7.5m, Outdoor LC/DPX to LC, IP67 FIB‐FA‐5‐LC‐SM‐ 1 686‐00‐016 FIB‐FA‐7.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Installation Kit / Part Part No. Airspan No.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Panels The following figures display the AirHarmony‐4200 DC Internal Filters bottom and top panels. The following displays the AirHarmony‐4200 DC’s bottom panel.
AirHarmony‐4200 DC (Internal Filters) Installation Guide The following displays the AirHarmony‐4200 DC’s Internal Filters unit top panel. Figure 5: AirHarmony‐4200 DC Internal Filters Unit, Top panel Physical Dimensions AirHarmony‐4200 DC Internal Filters unit is in an all outdoor enclosure. Table 9: AirHarmony‐4200 DC Physical Dimensions Variant Dimensions (H x W x D) AirHarmony‐4200 DC Internal Filters 509 x 236 x 210 mm / 20.0 x 9.3 x 8.3 in. Weight Main Unit 20 Kg / 44 Lbs.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Environmental AirHarmony‐4200 DC Internal filters unit meets the following environmental requirements: GR‐63 Storage and Transportation ETSI EN 300‐019‐1‐4 Operational (non‐weather protected equipment) ETSI EN 300‐019‐1‐1 Storage (weather protected, non‐temperature controlled locations) ETSI EN 300‐019‐1‐2 Transportation Table 10: AirHarmony‐4200 DC Environment Compliance Type Details Standard Compliance Operating temperature ‐40°C to
AirHarmony‐4200 DC (Internal Filters) Installation Guide 4 Installing AirHarmony-4200 DC Note: Proper clearance is required for proper placement of the AirHarmony unit on pole or wall. 500 mm clearance on bottom, 300 mm clearance on top and 100 mm clearance on sides and back from other objects in the vicinity. Install the AirHarmony‐4200 DC eNodeB by pole/wall mount. AirHarmony‐4200 DC is mounted on a pole or wall in close proximity to its external antenna (connectorized variant).
AirHarmony‐4200 DC (Internal Filters) Installation Guide connections. 4.2 Pole/Wall Mount Assembly Install the AirHarmony‐4200 DC eNodeB by pole/wall mount. AirHarmony‐4200 DC is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony‐4200 DC. Mounting on a Pole The following images show the pole mount assembly on a pole.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 4. Tighten the clamp bands with large flat screwdriver.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 8: Mounting plate mounted Mounting on a Wooden Pole Airspan provides an additional mounting alternative specifically for a wooden pole. The following images show the pole mount assembly on a wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 1. Select the location on the pole to mount the AirHarmony‐4200 DC. You can attach the AirHarmony‐4200 DC to any pole from 1‐7/8 to 16 inches (47.6 to 406.4 mm) in diameter. 2. Determine where to position the mounting plate on the pole and mark where to drill for insertion of the 3/8‐16 through‐bolt. Note: Threaded rod and necessary hardware are not supplied by Airspan and are the responsibility of the installer. 3.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 11: Through‐bolt & Mounting plate Mounting plate is installed and ready for AirHarmony‐4200 DC mounting. Mounting on a Wall The following images show the wall mount assembly. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. 1. Position mounting plate against the wall with mounting pins facing up.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 12: Mounting Plate on Wall UGD‐D01196 Airspan Commercial and Internal Use 35
AirHarmony‐4200 DC (Internal Filters) Installation Guide 4.3 Securing AirHarmony-4200 DC to the Mounting Plate Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony‐4200 DC on pole or wall. To mount AirHarmony‐4200 DC to the mounting plate, perform the following: 1. Lift up the AirHarmony‐4200 DC unit and hook the slotted holes onto the mounting pins (studs) on the top of the mounting plate.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 2. Lean the bottom of the unit into the mounting plate until the six (6) holes are aligned with the six (6) M8 clinch‐nuts on the mounting plate. There are two (2) on the top, near the mounting pins and two (2) on either side of the mounting plate for a total of six (6) . 3. Once aligned insert the supplied M8x20 Hex head bolt with a split washer and a flat washer into each clinch‐nut. 4. Check and tighten all six (6) M8x20 Hex head bolts.
AirHarmony‐4200 DC (Internal Filters) Installation Guide The following displays the AirHarmony‐4200 DC mounted on a wooden pole.
AirHarmony‐4200 DC (Internal Filters) Installation Guide The following displays the AirHarmony‐4200 DC mounted on a wall.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 5 AirHarmony-4200 DC Connections This section describes grounding procedure, cable preparation and connections and external antenna assembly. 5.1 Grounding The AirHarmony‐4200 DC requires a secure ground connection. The ground cable should be connected with the grounding screw fitted with a flat washer and lock washer to the bottom of the chassis clearly marked with the universal ground symbol as shown below.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 1. Attach, connect and secure the RF cable between the external antenna and the appropriate RF connection on the top of the External Duplexers. Caution: Antennas must be connected and attached before AirHarmony is powered on. Caution: Power down AirHarmony prior to disconnecting antenna. Note: First Sector/Carrier antenna should be connected to the top antenna ports. Second Sector/Carrier antenna should be connected to the top antenna ports.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 19: Gland connector ‐ copper 1. Remove the Gland connector by unscrewing the body from the AirHarmony‐4200 DC, using the (supplied) Gland wrench. 2. Pass the prepared Ethernet cable through the tail nut, gland seal, body and front seal of the connector casing as shown below. Do not tighten the tail nut. Figure 20: Ethernet Cable through connector 3. Seat the RJ45 connector plug securely into the body cavity of the AirHarmony‐4200 DC 4.
AirHarmony‐4200 DC (Internal Filters) Installation Guide module which eliminates the need to open the unit and expose its contents to hazardous weather conditions. Note: Airspan recommends using the Finisar ‐ FTLF1318P3BTL 1000BASE‐LX which has been tested and approved by Airspan. Available from Airspan if required. SFP Cable Connection Figure 21: LC duplex cable assembly 1. Remove the protective dust cap from the connector housing assembled on the unit. 2.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 23: Slide on inner housing Note: Check that there no space between the inner housing and mounting flange. Check and remove any debris that might interfere with the connection. 6. Slide the outer shell over the inner housing and turn the outer bayonet shell 1/4 turn clockwise, until it clicks into place. Figure 24: Slide over and click Note: The shell should be hand tightened only. Do NOT use tools to tighten the shell.
AirHarmony‐4200 DC (Internal Filters) Installation Guide 5.5 Connecting the DC Power Cable to AirHarmony4200 DC Danger: Hazardous voltage! Before working, ensure that the power is removed from the power connection cables. When the system is powered on, do not touch the power terminals. Tip: It is good practice to label both ends of the cable to identify which AirHarmony‐4200 DC unit it is connected to. Tip: It is good practice to leave a spare loop of cable (approximately 0.5m).
AirHarmony‐4200 DC (Internal Filters) Installation Guide Figure 26: Power Connector – Bottom Panel Connecting the DC Power Cable to AirHarmony 1. 2. Plan the position of the DC power cable run from the AirHarmony unit to the power supply unit. The DC power cable is offered in various lengths, to fit different deployments. Uncoil the cable and secure the connector just below the AirHarmony unit.
AirHarmony‐4200 DC (Internal Filters) Installation Guide UGD‐D01196 Airspan Commercial and Internal Use 47
AirHarmony‐4200 DC (Internal Filters) Installation Guide AC/DC Power Converter – Optional This section provides a description of the external AC/DC Power converter – Optional, available from Airspan. The third‐party external AC/DC Power Converter is an optional unit that connects to the AirHarmony‐4200 DC in the event there is no ‐48VDC availability at the site. Note: Airspan recommends using the AC/DC Power Converter for the AirHarmony‐4200 DC. Available from Airspan if required.
AirHarmony‐4200 DC (Internal Filters) Installation Guide A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirHarmony‐4200 DC installation.
AirHarmony‐4200 DC (Internal Filters) Installation Guide B Abbreviations Term Expansion 3GPP 3rd Generation Partnership Project, responsible for LTE ABS Almost Blank Subframes ACS Adjacent Channel Selectivity is a measurement of a receiver's ability to process a desired signal while rejecting a strong signal in an adjacent frequency channel.
AirHarmony‐4200 DC (Internal Filters) Installation Guide Term Expansion LED Light Emitting Diode LTE Long Term Evolution MAC Medium Access Controller – responsible for several functions such Error Correction, Packet (De)Multiplexing, etc… MBSFN Multicast‐Broadcast Single Frequency Network is an LTE feature designed to deliver services such as Mobile TV using the LTE infrastructure, and is expected to be a competitor to DVB‐H‐based TV broadcast MCS Modulation and Coding Scheme MME Mobility Manag