SYN-UG-007 Rev 1 AirSynergy Equipment Installation Guide
AirSynergy Equipment Installation Guide Copyright © Copyright by Airspan Networks Inc., 2011. All rights reserved worldwide. The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Inc. rights in the aforesaid information.
AirSynergy Equipment Installation Guide Table of Contents Copyright ................................................................................................................................................. 2 Table of Contents .................................................................................................................................... 3 Summary of Figures ...........................................................................................................................
AirSynergy Equipment Installation Guide 6.1 Mount Front antenna to the AirSynergy unit ......................................................................... 18 6.2 Secure AirSynergy and Antenna to pole mount plate ........................................................... 20 6.3 Install GPS Antenna .............................................................................................................. 23 6.4 Install GPS antenna for AirSynergy ..............................................
AirSynergy Equipment Installation Guide Summary of Figures Figure 1 – Typical AirSynergy with sun shield mounted on street pole ................................................. 9 Figure 2 – Workflow of AirSynergy Installation ..................................................................................... 10 Figure 3 – AirSynergy connectorised unit with sunshield ..................................................................... 15 Figure 4 – AirSynergy unit with front sector antenna fitted ......
AirSynergy Equipment Installation Guide Summary of Tables Table 1 - AirSynergy installation tools ................................................................................................... 13 Table 2 – AirSynergy installation parts and kits ....................................................................................
AirSynergy Equipment Installation Guide 1 About This Guide This section discusses the purpose, intended audience, conventions, referenced documentation and organisation for this guide. 1.1 Purpose This guide provides the workflow and step-by-step procedures for Installation of the AirSynergy equipment. These procedures include: Verify Prerequisites Install the AirSynergy Radio equipment Install the PSU equipment Connect and manage cables 1.
AirSynergy Equipment Installation Guide 1.
AirSynergy Equipment Installation Guide 2 Introduction This section provides a descriptive overview of the product. 2.1 General Overview AirSynergy equipment comes in a range of frequency variants that can be mounted with different antenna options Figure 1 – Typical AirSynergy with sun shield mounted on street pole 2.1.1 Sector Antenna arrangement A typical sector installation will have a cross- polar sector antenna fitted directly to the front of the AirSynergy main unit.
AirSynergy Equipment Installation Guide 3 Get Started 3.
AirSynergy Equipment Installation Guide 3.2 Installation Checklist Plan the installation of the AirSynergy Unit by using the Installation Checklist in Appendix A.
AirSynergy Equipment Installation Guide 4 Verify Prerequisites 4.1 Verify Site Requirements To set up the AirSynergy for connection to Netspan, a PC will be required. 4.2 Verify Safety Requirements Read and follow all warning notices and instructions marked on the product or included in this manual. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed.
AirSynergy Equipment Installation Guide 4.3 Verify Installation Requirements 4.3.1 Verify the Tools Table 1 - AirSynergy installation tools Tools Small flat blade Screwdriver Large Flat Bladed Screwdriver 20mm wrench or small Pipe wrench 10mm wrench Wire strippers Wire cutters Small cross-head screwdriver Ring terminals crimp tool Tilt-meter (if accurate downtilt needs to be set) Krone punch-down tool 4.3.
AirSynergy Equipment Installation Guide Connecting cables CAT5e External grade 25m with Weather hood pre-fitted Earthing cable M6 Lug at each end Table 3 - AirSynergy additional items Additional items (not provided by Airspan) Cable ties Self amalgamating tape Black PVC tape Ring terminal for earth strap, M6 Earth strap cable (4mm), yellow and green cable Table 4 – Antenna and feeder kits Installation Kit / Part Antenna / Feeder (not always provided by Airspan) Note Antenna and feeder Short feeder t
AirSynergy Equipment Installation Guide 4.3.
AirSynergy Equipment Installation Guide 5 Install the AirSynergy mounting plate 5.1 Mount the AirSynergy Universal Mounting Plate The AirSynergy is normally mounted on a pole (in close proximity to its external antenna if not using the AirSynergy front mounted Antenna. Take care to install the mounting plate the correct way up so that the AirSynergy unit will fit with the PoE connector pointing downwards.
AirSynergy Equipment Installation Guide Figure 8 – Tighten clamps with large flat blade screwdriver Figure 7 – AirSynergy mounting plate installed (large diameter concrete pole) Page 17 Commercial in Confidence SYN-UG-007 Rev 1
AirSynergy Equipment Installation Guide 6 Fit Front sector antenna to AirSynergy The AirSynergy unit can be used either with a sector antenna mounted directly on the front or with a remotely attached RF antenna. 6.
AirSynergy Equipment Installation Guide Figure 10 – AirSynergy Front mount antenna connections – applying self amalgamating tape Apply a layer of self amalgamating tape and a layer of electrical tape to the weather-exposed RF connector. Figure 12 – AirSynergy antenna connections – applying PVC tape Ensure the RF connector is completely sealed from the weather.
AirSynergy Equipment Installation Guide 6.2 Secure AirSynergy and Antenna to pole mount plate To mount the AirSynergy to the universal mounting plate, perform the following steps: 1. Hook the studs into the top slots of the mounting plate. With the studs engaged in the top slots raise the unit slightly until the bottom studs also drop into their respective slots. Secure the flange nuts (4 positions).
AirSynergy Equipment Installation Guide Figure 16 – Gently lift the AirSynergy body until the bottom studs engage in the bottom slots Figure 17 – AirSynergy body engaged in the bottom slots 2. The slot arrangement at the top allow the AirSynergy and front mounted antenna to be downtilted by a few degrees to provide real downtilt or to compensate for the taper angle on the pole.
AirSynergy Equipment Installation Guide 3. The downtilt angles are not marked by the adjustment slots so a tiltmeter is required to set a specific angle and then tighten the flange nuts ith a 10mm wrench on each stud (4 positions) Figure 13 – Tighten flange nuts (4 poitions) once the required mounting angle is set 4. There is an option to connect an earthing cable to the M6 screw fixing point at the bottom of the main body casting.
AirSynergy Equipment Installation Guide . 6.3 Install GPS Antenna 6.4 Install GPS antenna for AirSynergy Note: AirSynergy units without a factory fitted Switching antenna all require a GPS antenna which comes in a kit with a mounting bracket and a 25cm cable. A prime consideration for a GPS antenna is a clear view of the sky, preferably 360 degrees Install the GPS antenna bracket to the AirSynergy unit using the M6 threaded hole near the top of the main using the fixing.
AirSynergy Equipment Installation Guide 7 Connect to Power System Caution: Hazardous voltage! Before working, ensure that the power is removed from the power connection cables. When the system is powered on, do not touch the power terminals. 7.1 Connect PSU Output to PoE injector 7.
AirSynergy Equipment Installation Guide 8 Appendix A 8.
AirSynergy Equipment Installation Guide Network configuration information for the SDR blade. This shall include the following information for the front panel and the backplane. o IP Address: Should only be set if Management IP Mode is set to Static IP Address. See below for Management IP Mode parameter. o Netmask: Should only be set if Management IP Mode is set to Static IP Address. See below for Management IP Mode parameter.
AirSynergy Equipment Installation Guide 9 Appendix C – Glossary of Terms AAA Authentication, Authorization and Accounting ARQ Application Function ASN Automatic Repeat reQuest ASN GW Access Service Network ASN Gateway BS Base Station BWA Broadband Wireless Access CPE Customer Premises Equipment FDD Frequency Division Duplex GUI Graphical User Interface HO Handover/Handoff IP Internet Protocol MAC Media Access Control MIMO Multiple Input Multiple Output MS Mobile Station NLOS No
AirSynergy Equipment Installation Guide 10 Appendix D – Checklist The Checklist below gives the high-level steps in the Workflow for this procedure. Detach or print this page to use as a job-aid for completing the actions this procedure requires. Table 3 - Checklist for Procedure Procedure Actions Outcome 1. Verify Prerequisites Verify site requirements All requirements are in place for a successful installation Verify safety requirements Verify installation requirements 2.
AirSynergy Equipment Installation Guide 11 Appendix E 11.1 Revision History Revision Originator Date 1 J. Forrester 07-2011 Description Customer Service Help-Desk for customer service emergency Airspan Networks have introduced the Airspan Tracker application to enable prompt and efficient Customer Support services. If you do not have an Airspan Tracker account, please obtain login credentials by filling-in the form in the main page at www.airspan.com/Support Register New Account.