Specifications

COMMUNICATING SYSTEM
R
616 51 1003 01 7/8/2015
Specifications subject to change without notice.
Color Touch-screen Communicating Wall Control
For use in Single or Multi-Zone Installations
EASIER TO SELL
Supports Observer System communicating equipment multistage Heating and Cooling
operation, including modulating gas furnaces (version 4.02 and later) and inverter
compressor sections (version 5.01 and later). NOTE: The TSTAT0101SC wall control is
NOT compatible with inverter outdoor units.
Model TSTAT0201CW features Remote Access via home Wi-Fi
R
network; See www .MyObserverComfort.com
for more information and access to iOS and Android mobile apps.
High definition full color touch-screen display
Simplified programming with options for 4 daily periods during individual days,
all days same, or weekday/weekend schedule; California Title 24 compliant
Two hold options, including indefinite hold and timed override hold
Selectable constant fan speed option – Low, Medium, High
(with compatible indoor equipment)
Selectable screen backlight brightness, including 30%/Off
Screen cleaning function (disables touch-screen for 30 seconds)
Adjustable/resettable filter and service reminders
Touch-screen lockout option
When installed as part of a complete Observer Zoning System,
the TSTAT0101SC and TSTAT0201CW can be used as a Zone Sensor option
for Zones 2 through 6.
EASIER TO INSTALL
4wire (or 2/3 wire depending on the communicating outdoor unit used) installation
from each compatible component in the system
Communication with all compatible components in the system
Self configuration with all compatible components in the system
Option to use NAXA00101DB Daughter Board for connection with
non-communicating system components (Single or Multi-Zone Installations)
Supports up to 4 stages Heat, 2 stages Cool for noncommunicating equipment
True Dual Fuel compatible
Full humidity control (with compatible equipment)
Outdoor temperature automatically received from compatible outdoor component,
or use accessory OD temp sensor with non-communicating equipment and daughter board
QWERTY keyboard for data entry
Selectable brand logo (or no logo)
EASIER TO SERVICE
Non-volatile memory with 8+ hour clock retention, holds program
settings indefinitely without power
Text based diagnostics viewable on screen
Up to last 10 diagnostic fault messages viewable on service screens
Enter dealer name and contact info for display during a fault
Physical Characteristics
Dimensions H x W x D inch(mm) Appearance
3.9 x 5.2 x .97 (99 x 132 x 25) Plastic, white color, textured
Electrical Characteristics / Communication
Input Volts/Amps 24VAC, 500ma maximum
Each device in the Observer Communicating System has a four-pin
connector labeled DX+, DX-, R, C
It is recommended that the color code be used when wiring each
device
DX+ = Green = Data A
DX- = Yellow = Data B
C = White = 24VAC (Com)
R = Red = 24VAC (Hot)
Wiring Requirements Wall Control
Power Supply Wiring Material (field supplied)
24VAC, 12 VA maximum, 50/60 Hz, via indoor equipment DX+ DX-
C R Connector
Standard thermostat wire, 18 AWG recommended
Environmental Requirements Wall Control and Accessories
Operating Temp./ Relative Humidity Storage Temp./ Relative Humidity Setpoint Specifications
Wall Control and all sensors: 32F to 104F /
0C to 40C, 95% rh non-condensing
Wall Control: -40°F to 134°F / -40°C to 57°C,
95% rh non-condensing
Temperature set point range: 40°F to
90°F / 4°C to 32°C
All trademarks are the property of their respective owners. WiFi
is a registered trademark of WiFi Alliance Corporation.
®
TSTAT0201CW
Product Specifications

Summary of content (3 pages)