CAM Pressure Remote Gen 2 User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 Cylinder Asset Monitor (CAM) Pressure Remote Gen 2 (Model # CAM-PR2) User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 February 2021 DISCLAIMER Information contained in this document is offered for use by technically qualified personnel at their discretion and risk.
CAM Pressure Remote Gen 2 User Manual Contents DISCLAIMER 1 Safety Information 3 General Warnings 3 Hazardous Location Use Warnings 3 Hazardous Location Use Instructions 3 Product Users 3 Personal Protective Equipment (PPE) 3 Cylinder / Vessel Handling 4 Safety Precautions 4 Electrical Hazards 4 Overview 5 General Specifications 5 Getting Started 6 CAM Wi-Fi Concentrator Installation 6 Connecting CAM Wi-Fi Concentrator to Wi-Fi 6 Max Gateway Installation 7 CAM Pressure Remot
CAM Pressure Remote Gen 2 User Manual 1. Safety Information Please read and understand the User Manual completely before installing and operating a Cylinder Asset Monitor (CAM) Pressure Remote, including all local safety procedures and policies. See Regulatory Statements at the end of this document for more information. 1.1. General Warnings The warnings in this manual supplement the safety policies of the user’s company and local authorities.
CAM Pressure Remote Gen 2 User Manual wearing hand and eye protection be used when handling or servicing CAM devices. ● ● 1.6. Cylinder / Vessel Handling When used with cylinders, the user should observe cylinder / vessel handling precautions. Cylinders or other vessels may contain hazardous liquids or gases under high pressure. Improper handling could release hazardous material to the environment and cause dangerous projectiles. Only properly trained personnel should handle cylinders and other vessels.
CAM Pressure Remote Gen 2 User Manual 2. Overview Thank you for selecting the Airgas CAM system. The CAM system will help to streamline the process of measuring, reporting metrics, local temperature and manage no-runout delivery of high-pressure cylinders. This CAM Pressure Remote is intended to be used on a pressurized system. This device helps to provide a management tool by providing 24 / 7 remote monitoring.
CAM Pressure Remote Gen 2 User Manual 4. Getting Started Doc. No. AG-USM-02-A100 Rev. 0.00.04 illustrate sequence screens of CAM Wi-Fi Concentrator during power up: This section outlines how to setup and configure a CAM Pressure Remote with a CAM Wi-Fi Concentrator or Max Gateway. Please see the user manual for your specific device for details before installation and use. Once your CAM instrument package is received, remove the packing list and verify that you have received all components.
CAM Pressure Remote Gen 2 User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 will see the SSID of the AP you selected displayed on the LCD. Otherwise, repeat the from the beginning to retry. Also, please see the WiFi Concentrator’s user manual for details. 4.3. Max Gateway Installation The Max Gateway is a pre-configured cellular plug and play device. Once the Max gateway is plugged into the AC power outlet, there is no further set up steps required.
CAM Pressure Remote Gen 2 User Manual 1. 2. Open the CAM Pressure Remote by removing the 4 screws on the front cover of the CAM Pressure Remote using the provided screwdriver. Insert two Lithium primary batteries into the battery compartment. Doc. No. AG-USM-02-A100 Rev. 0.00.04 Once the CAM Pressure Remote has been set up. Please contact Airgas Retail Solutions to provision the CAM System with your CAM Pressure Remote Media Access Control ID (MAC ID) (See Figure 12).
CAM Pressure Remote Gen 2 User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 5. Operating Procedure 4.6.2. CAM Pressure Remote Installation with a Helium Regulator There is no operation and interaction required for the CAM Pressure remote. Please apply precautionary safety procedures during installation. This involves the following steps: 1. If not already installed, attach CAM Pressure Remote to the regulator per instructions above 2. Attach helium regulator to cylinder.
CAM Pressure Remote Gen 2 User Manual 6. Product Dimensions 6.1. CAM Pressure Remote with 1/4NPT Transducer (CAM-PRx-x1 & CAM-PRx-x2) Doc. No. AG-USM-02-A100 Rev. 0.00.04 6.3. CAM Pressure Remot with 1/4VCR Transducer (CAM-PRx-x5) (Measurements in mm) (Measurements in mm) 6.2.
CAM Pressure Remote Gen 2 User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 7. General Maintenance & Contacting Airgas 3. Preventative maintenance, when properly performed, will help to ensure that the system continues to operate properly. The system should be inspected periodically so that defects can be corrected before they result in failure. 7.3.
CAM Pressure Remote Gen 2 User Manual 8. Regulatory Statements & Labels 8.1. Product Labels Doc. No. AG-USM-02-A100 Rev. 0.00.04 However, there is no guarantee that interference will not occur in a particular installation.
CAM Pressure Remote Gen 2 User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 RSS-210 Warning Statement – The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb. RSS-GEN. ISSUE 4, SECTION 8.4 – This device complies with Industry Canada’s license-exempt RSSs.
CAM Pressure Remote Gen 2 User Manual Doc. No. AG-USM-02-A100 Rev. 0.00.04 9. Troubleshooting Guide All users must read and understand this manual before attempting any operation or service of the CAM system. All users must be instructed in the proper use of all required personal protective equipment (PPE).