Installation Instructions

- INSTRUCTIONS -
The RY-1824L door release relay module is an interface between the door release contact on the Aiphone master station
or CEU and the actual release mechanism. The contact closure directly from the master station or CEU has limited voltage
and current capacity. Use the RY-1824L to ensure that the contact rating will be sufficient for the electric strike or magnetic
lock used. The relay’s contact rating supports a majority of door release hardware available. This relay is recommended
for all AX, KB, JF, JO, and JP Series systems when using door release and will protect the built-in contact from possible
surge damage.
(Note: Use the RY-3DL when releasing more than two doors in a JP Series, or more than one door in a JF or KB Series).
RY-1824L
Form C Door Release Relay for AX, KB, JF, JO, and JP Series
WIRING DIAGRAMS:
Page 1
INSTALLATION:
1. Install near the power source for the door release mechanism, or behind the master station or CEU.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length.
4. Trim the unused contact wire so the bare strands are not exposed.
RED: (+) Pos.
BLK: (-) Neg.
BRN: Common
ORG: N/O
YEL: N/C
RY-1824L COLOR CODE:
Input of Relay:
Red: (+) Positive
Black: (-) Negative
Output of Relay:
Brown: Common
Orange: N/O contact
Yellow: N/C contact
(See contact rating specs on page 4)
1A1
1A2
M(Out)
2A1
2A2
PS-2420UL
+
-
Door #1
JP-DV
A1
A2
3A1
3A2
4A1
4A2
DOOR 1DOOR 2
DOOR 3DOOR 4
Blk
Brn
Org
Yel
RY-1824L
Red
LOCK
POWER
Door
Release
#1
Brn
Org
Yel
RY-1824L
Door
Release
#2
Blk
Red
MAGNETIC LOCK
WIRING METHOD:
(Normally Closed contact)
+
-
LOCK
POWER
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Door #2
JP-DV
A1
A2
COM
N/O
N/C
NOTE: The door release contacts on the station are rated at 24V AC/DC, 500mA. The RY-1824L should be used in any
application where the strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the
master station could occur.
JP Series Wiring
19310 0519
L1
L1
L2
L2
JP-4MED
RY-1824L