EX5210R RUGGED EXCITER INSTALLATION & CONFIGURATION GUIDE DRAFT 1: Updated 2018/10/10
Disclaimer The information and know-how included in this document are the exclusive property of STANLEY Healthcare and are intended for the use of the addressee or the user alone.
EX5210R Exciter Installation & Configuration Guide Table of Contents Introduction .................................................................................................. 5 Exciter Applications and Industry Examples .............................................. 6 Theft Prevention ..................................................................................................6 Process Control .....................................................................................................
EX5210R Exciter Installation & Configuration Guide Resetting the Exciter IP Address................................................................ 24 Mounting the Exciter .................................................................................. 25 Fixing the Exciter to a Wall/Ceiling.................................................................... 25 Mounting the Exciter to a Poll...........................................................................
EX5210R Exciter Installation & Configuration Guide Introduction The EX5210R Rugged Exciter is a component of the STANLEY Healthcare suite of enterprise-level visibility solutions based on standard Wi-Fi wireless communications for location- based applications. The EX5210R Exciter is designed for outdoor mounting, providing robust and sophisticated RFID detection capabilities. The EX5210R Exciter triggers tags as they pass through a chokepoint or as they approach the Exciter.
EX5210R Exciter Installation & Configuration Guide Exciter Applications and Industry Examples Theft Prevention Healthcare organizations or enterprises with expensive and mission-critical equipment can tag valuable assets that are intended to remain within a specified area. The AeroScout System can track the location of such items and trigger an alert when they pass through an exit point or enter a restricted area.
EX5210R Exciter Installation & Configuration Guide Exciter Features RFID Detection of STANLEY Healthcare Tags The Exciter triggers Tags to transmit as they pass through a defined area, within a range of up to 6.5 meters (21.3 feet)*. This is typically enough to cover door or gate areas. The Exciter also supports a chained configuration, thus enabling an increased RFID detection range for larger areas. *In an outdoor environment, the Exciter’s actual LF coverage range is a maximum of 3meters (9.
EX5210R Exciter Installation & Configuration Guide Message Programming Functions The Exciter can store messages on the Tag for subsequent transmission. The stored messages can subsequently be triggered by other Exciters, enabling sophisticated process control functions.
EX5210R Exciter Installation & Configuration Guide LED Status Indicators The EX5210R has a single LED that changes color based on the Exciter's status as follows: Green (continuous): The Exciter is transmitting and functioning correctly Green (Blinking) During Firmware upgrade the Exciter blinks green until the upgrade is complete Red (Blinking) During IP reset the Exciter blinks red Red (continuous): Error 9
EX5210R Exciter Installation & Configuration Guide Exciter Connector Panel The EX5210R Exciter connection panel is housed in the sealed compartment at the back of the Exciter. Exciter Mounting Plate 8 Mounting Plate Screws Sealed Connector Compartment Unscrew the 8 mounting plate screws and remove the plate.
EX5210R Exciter Installation & Configuration Guide The Exciter has four connectors and two switches inside the back panel: 5 4 3 2 1 6 Figure 3: EX5210R Connector Wiring (#1) Ethernet LAN Connection: RJ-45 connector. In a configuration with a physical Ethernet cable connection to the LAN, the network cable is attached here. Permanent connection to a wired network is not mandatory. However, you must have a wired connection to configure the Exciter.
EX5210R Exciter Installation & Configuration Guide Wiring the Exciter When wiring the Exciter, all cables must be pushed through the removable cable rubber plug and then connected to the required port. Use the cable holder to keep the cables in-line with the rubber’s holes. Cable Holder Cable Rubber Plug TB-L IN OUT TB-R PWR LAN / PoE Once the cables are connected correctly, place and screw in the mounting panel.
EX5210R Exciter Installation & Configuration Guide LF Coverage The EX5210R has an adjustable coverage range between 0.5m (1.6 ft.) and 6.5m (21.3 ft.) in intervals of 0.5 m (1.6 ft.). LF Coverage varies according to location* *Indoor LF Coverage is around 6.5 meters (21.3 feet). Outdoor LF Coverage is around 3 meters (9.8 feet). The LF coverage pattern set at 4m is displayed in Figure 5.
EX5210R Exciter Installation & Configuration Guide Network and Power Connections The following is a brief summary of available powering and networking options: Usage Option Description Single EX5210R– not connected to a network EX5210R can be used as standalone device that functions independently without any network connection. In this case, you only need to connect the Exciter to the power supply. Using the AeroScout Engine Manager (AEM), set the device as “not connected to the network.
EX5210R Exciter Installation & Configuration Guide Direct Power Supply To connect to the power supply, connect a 110/220 VAC to 48 VDC power Adaptor to the Exciter’s power jack. Figure 5: 110/220 VAC to 48 VDC Adaptor Note The EX5210R requires approximately 6W of power. When connecting an Exciter to a direct power source, verify that the power level is sufficient.
EX5210R Exciter Installation & Configuration Guide 110/220 VAC to 48 VDC PoE Single-Port Injector The PoE Single Port Injector converts 110/220 VAC to 48 VDC. In addition, it can receive a network connection and you can run a single cable to the Exciter’s LAN connector, thus supplying both power and network connectivity. When using this injector, the Exciter power jack is not used. Figure 6: 110/220 VAC to 48VDC PoE Single-Port Injector The injector’s IN connector is connected to the network.
EX5210R Exciter Installation & Configuration Guide Power Connection Summary The following table summarizes the power connection options: Power Supply Input Output Maximum Available Maximum # Current of Exciters Power with One Source PoE single port injector 100-240 VAC, 5060 Hz 48 VDC 0.32 A(1) 15.4 W Two Standard PoE 802.3af – switch port(2) 48 VDC 0.32 A(1) 15.4 W Two External power Adaptor 48 VDC > 0.
EX5210R Exciter Installation & Configuration Guide Chaining EX5210R Exciters In an area where the required LF coverage exceeds the capacity of one Exciter, you can extend the coverage by chaining several Exciters. For example, a large entrance with two sets of double doors too wide for a single Exciter might require two Exciters chained together. The system treats Chained Exciters as a single device with a single ID. Transmissions do not interfere with one another.
EX5210R Exciter Installation & Configuration Guide 4. The Termination Switch of the Primary Exciter and the last Chained Exciter in the chain must be set to On (o-o). On the other Chained Exciters, it must be set to Off (-o o-). 5. The Primary/Chaining configuration is set via AeroScout Engine Manager. Chained Exciters inherit the Primary Exciter ID and LF configuration. Transmission range is configurable. See Configuring Chained Exciters.
EX5210R Exciter Installation & Configuration Guide • Under Exciter Modules (General > Settings tab), make sure Enable is checked. • Under Chaining and External Connections (General > Settings tab), check Slave Exciter. 4. Under IP Configuration, uncheck Connected to Network. 5. Click OK. 6. Connect the Chained Exciter to the Primary Exciter.
EX5210R Exciter Installation & Configuration Guide Configurations for Engine 5.3 and above 1. Connect the Chained Exciter directly to the network via the LAN port. 2. In the General Settings tab, under Network Configuration, make sure Connected to Network is checked. 3. Select the LF General tab and configure the following parameters: • 4. Under General LF Parameters select LF Chaining as Chained. Select the Internal LF tab and configure the following: • 5.
EX5210R Exciter Installation & Configuration Guide 6. Click OK. 7. Connect the Chained Exciter to the Primary Exciter.
EX5210R Exciter Installation & Configuration Guide DHCP Exciters with firmware version 314.54 and above support Dynamic IP (DHCP) and Static IP configurations. Static: The IP address and connection settings are specified manually. Dynamic (DHCP): The DHCP server automatically assigns an available IP every time the device connects to the network. Exciters with firmware version 314.54 and above will be set to DHCP by default.
EX5210R Exciter Installation & Configuration Guide Resetting the Exciter IP Address You can reset the Exciter’s IP address to the factory default value. The default IP address is 192.168.1.178. To do so, press the IP Reset button with a ballpoint pen for 5 seconds. After a successful IP reset, a flashing red LED indication appears for three seconds.
EX5210R Exciter Installation & Configuration Guide Mounting the Exciter Position and mount each EX5210R Exciter in the site according to the site survey recommendations. The EX5210R Rugged Exciter is designed for outdoor mounting using a specifically designed mounting plate. Mounting options include: Walls Ceilings Polls Fixing the Exciter to a Wall/Ceiling 1. Using the mounting plate as a template, place and hold the mounting plate to a wall or ceiling surface. 2.
EX5210R Exciter Installation & Configuration Guide 5. Align the Exciter with the attachment hooks on the mounting plate. Exciter attachment hooks Exciter attachment hooks 6. Place the Exciter into the mounting plate and press the Exciter down until it locks into place.
EX5210R Exciter Installation & Configuration Guide 7. When the Exciter is correctly locked into place, the mounting plate’s security flange will align with the Exciter’s side screw holes. Mounting plate security flange Exciter side screw holes 8. Screw in the Exciter to the mounting plate’s security flanges. Mounting the Exciter to a Poll The mounting plate can be mounted to a poll using a U-Bolt mounting kit.
EX5210R Exciter Installation & Configuration Guide Appendix A: Exciter and Accessories Product SKU Description EX5210R Exciter EX-5210R M/N: EX-5200R EX5210R Exciter includes 48 VDC input, Ethernet and PoE interface. Wall mounting plate included. Power supply not included. Exciter Power Supply APD-047-U (US) AC/DC Adaptor 45W 48 V/1.0A 90-264VAC APD-047-E (Europe) for EX2000B, EX4210, EX5000, EX5200 and EX5210R Exciters.
EX5210R Exciter Installation & Configuration Guide Appendix B: Exciter Specifications Product Model SKU: EX-5210R M/N: EX-5200R Physical and Mechanical Dimensions: 232mm X 262mm X 102mm (9.1in x 10.3in x 4in) Weight: 1.8 kg (4lbs) Housing: Reinforced Polycarbonate with 10%GF (Lexan 503R from Sabic) Coverage Adjustable coverage range between 0.5m (1.6 ft.) and 6.5m (21.3 ft.) by intervals of 0.5 m (1.6 ft.).
FCC Compliance Statement This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception.
About STANLEY Healthcare STANLEY Healthcare provides over 5,000 acute care hospitals and 12,000 long-term care organizations with enterprise solutions that create a safe, secure and efficient healthcare experience across life’s stages. The STANLEY Healthcare solution set enables customers to achieve organizational excellence and superior care in critical areas: Patient/Resident Safety, Security & Protection, Environmental Monitoring, Clinical Operations & Workflow and Supply Chain & Asset Management.