EX3300 SERIES EXCITERS INSTALLATION & CONFIGURATION GUIDE
Disclaimer The information and know-how included in this document are the exclusive property of STANLEY Healthcare and are intended for the use of the addressee or the user alone.
EX3300 Series Exciter Installation & Configuration Guide Table of Contents Introduction .........................................................................................................4 EX3300 Features ...................................................................................................5 Supported Dispenser Models ...............................................................................6 Installing the Exciters ..................................................................
EX3300 Series Exciter Installation & Configuration Guide Introduction The EX3300 Series Embedded Exciters are key components of STANLEY Healthcare’s Hand Hygiene Compliance Monitoring Solution. Together with STANLEY Healthcare’s suite of enterprise visibility solutions, the EX3300 Exciters provide robust and sophisticated RFID detection and monitoring capabilities. The EX3300 Exciters are designed specifically to be embedded in touch free or automated Hand Hygiene dispensers.
EX3300 Series Exciter Installation & Configuration Guide EX3300 Features Hand Hygiene Dispenser Integration EX3300 Exciters are designed to be embedded in specific touch free or automated GoJo or Ecolab dispensers. The embedded Exciter reacts to dispenser activation and triggers the tag, in range, to transmit a message. Configurable Transmission Range EX3300s have a range of up to2 meters (6.5 ft.) which can be configured using the Exciter Manager Tool.
EX3300 Series Exciter Installation & Configuration Guide Supported Dispenser Models The EX3300 Exciters are designed for integration in the following GoJo and EcoLab dispensers.
EX3300 Series Exciter Installation & Configuration Guide Installing the Exciters This chapter describes how to install the EX3300 Exciters in the different dispenser models. Each dispenser model is compatible with a specific EX3300 Exciter model. Note The EX-3300 Exciter must only be installed in the EcoLab Hand Sanitizer Dispenser or the GoJo Hand Sanitizer Dispensers. Installing the EX3300 Exciter in an EcoLab Next Gen Dispenser To open the dispenser: 1.
EX3300 Series Exciter Installation & Configuration Guide To attach the Exciter Connector Cable: 3. Connect the black connector of the connector cable into the Exciter. 4. Remove the entire internal dispenser mounting assembly from the dispenser casing by depressing the holding clip on the top of the assembly. 5. Route the cable over the top of the assembly ensuring the cable is not snagged or twisted. 6. Apply the connector wire retaining tape to the top of the mounting assembly.
EX3300 Series Exciter Installation & Configuration Guide 7. Connect the white connector in the socket provided on the back of the mounting assembly. 8. Replace the dispenser mounting assembly in the case.
EX3300 Series Exciter Installation & Configuration Guide To Install the Soap Container: The soap dispenser is installed with the offset dispensing nozzle on the bottom of the container positioned facing forwards. 1. Remove the protective cap covering the dispensing nozzle 2. On the dispenser tilt the white cylindrical nozzle mount forwards. 3. In the tilted position align and insert the dispenser nozzle in the cylindrical mount. 4.
EX3300 Series Exciter Installation & Configuration Guide Installing the EX3300 in an EcoLab NEXA Dispenser To open the dispenser: 1. Simultaneously press the two buttons situated on both sides of the dispenser. This releases the front of the dispenser's outer casing, allowing it to open forwards. To Install the EX3300 Exciter: 2. Remove the tape from the double sided Velcro on the back of the Exciter casing. 3.
EX3300 Series Exciter Installation & Configuration Guide Figure 2: Exciter placement in NEXA standard (right) and NEXA Compact (left) To attach the Exciter Connector Cable: 1. Connect the black connector of the connector cable to the Exciter. 2. Remove the soap container if needed. 3. Insert the white connector into the socket provided on the front of the dispenser. A protective rubber cover may need to be removed from this socket before inserting the connector.
EX3300 Series Exciter Installation & Configuration Guide 4. After replacing the soap container, close the dispenser casing and test both the dispensing mechanism and Exciter operation.
EX3300 Series Exciter Installation & Configuration Guide Installing the EX3300 in a GOJO TFX Dispenser To open the dispenser: 1. Open the dispenser by pressing the large button situated on the bottom of the dispenser. This releases the (bottom) hinged outer casing of the dispenser, from the back panel, allowing it to open forwards. Note Approach from the side, being careful to not activate the dispensing mechanism. To install the Exciter: 1. Remove the soap container if needed. 2.
EX3300 Series Exciter Installation & Configuration Guide Exciter 4. Re-insert the battery into the dispenser. 5. Reinstall the soap container back into the dispenser. 6. Close the dispenser casing. 7. Test the Exciter and dispenser operation.
EX3300 Series Exciter Installation & Configuration Guide Installing the EX3300 in a GOJO LTX Dispenser To open the dispenser: Simultaneously press the two buttons situated on both sides of the dispenser. This releases the front of the dispenser's outer casing, allowing it to open forwards. To install the Exciter: 1. Remove at least one of the batteries of the dispenser to cut the power to it. 2. Snap the Exciter into its customized compartment in the front side of the dispenser.
EX3300 Series Exciter Installation & Configuration Guide Audio jack Exciter 4. Insert the battery/s that was removed back into the dispenser. 5. Insert the soap container back into the dispenser. 6. Close the dispenser casing. 7. Test the Exciter and dispenser operation.
EX3300 Series Exciter Installation & Configuration Guide Adding the Exciters to the Engine Manager Follow these steps: 1. 2. Do one of the following: • In a Cisco-based configuration using MSE 7.4 or below, add Exciters via the Cisco NCS/PI when, Consult Cisco documentation for further information • In a non Cisco environment or when using Cisco MSE 7.
EX3300 Series Exciter Installation & Configuration Guide Note If the ID is already in use by another Exciter, and the Exciter is reachable (not offline), the system automatically switches IDs between the two Exciters. If the Exciter is unreachable, change the ID manually. g. Click OK. h.
EX3300 Series Exciter Installation & Configuration Guide Advanced Configuration Advanced configuration of the EX3300 Exciter is done via the Exciter Manager. The Exciter Manager Tool enables configuring the Exciter's maximum transmission range and Exciter ID. EX3300 Exciters are configured using a customized serial cable via the Exciter Manager Tool. The cable is not supplied with the Exciters and must be ordered separately.
EX3300 Series Exciter Installation & Configuration Guide Figure 5: Customized EX3300 Serial Cable for GOJO LTX and TFX Dispensers (CAB-3300LTX) Replacing a Malfunctioning Exciter If an embedded EX3300 Exciter is identified as malfunctioning or damaged it can be replaced on site by performing the following tasks: 1. Open the dispenser and remove the EX3300 Exciter. 2.
EX3300 Series Exciter Installation & Configuration Guide EX3300 Series Exciter Models and Cables Summary Vendor SKU EX-3300-ELB Name EX3300 Hand Hygiene Exciter for EcoLab Next Gen Dispensers Dispenser Type Dispenser Image Next Gen Part Number Exciter Image 92021121 eKey Configuration Cable N/A CAB-3300-CN N/A CAB-3300-CN Cable Image Long Cable EcoLab EX-3300-NEXA EX3300 Hand Hygiene Exciter for EcoLab NEXA Dispensers NEXA 92021188 (large) 92021184 (small) Short Cable GOJO EX-3300-L
EX3300 Series Exciter Installation & Configuration Guide EX3300 Specifications Physical and Mechanical for the GoJo TFX Exciter (including housing) • Dimensions: 80 x 48 mm x 45 mm (3.2 in. x 1.9 in. x 1.8 in.) • Weight: 30 g (1.1 oz.) Physical and Mechanical for the GoJo LTX Exciter (including housing) • Dimensions: 80 x 48 mm x 20 mm (3.2 in. x 1.9 in. x 0.8 in.) • Weight: 30 g (1.1 oz.) Physical and Mechanical for the EcoLab Exciters (including housing) • Dimensions: 62 x 63 mm x 13 mm (2.4 in.
EX3300 Series Exciter Installation & Configuration Guide Certifications • • EMC Certifications o US standard: FCC part 15 o European standard: ETSI 300.328, 300.330, ETSI 301.
WARNING: Insertion of an EX-3300 Exciter into any host other than the EcoLab Hand Sanitizer Dispenser or the GoJo Hand Sanitizer Dispenser invalidates the FCC ID authorization and Industry Canada certification of the EX-3300 Exciter. WARNING: This device complies with Part 15 of the FCC Rules and RSS-210 of Industry and Science Canada.
About STANLEY Healthcare STANLEY Healthcare provides over 5,000 acute care hospitals and 12,000 long-term care organizations with enterprise solutions that transform safety, security and operational efficiency. The STANLEY Healthcare solution set enables customers to achieve organizational excellence and superior care in five critical areas: Security & Protection, Safety, Environmental Monitoring, Clinical Operations & Workflow, and Supply Chain & Asset Management.