Engineering Specification Temperature Humidity Sensor Engineering Specification
Engineering Specification Table of Content 1 Overview ....................................................................................................................................................................... 1 2 Specifications ................................................................................................................................................................. 2 3 2.1 Structural Characteristics ...................................................................
Engineering Specification 1 Overview The Temperature Humidity Sensor measures the three air quality parameters temperature, humidity and dew point and reports them to a central controller. Besides this, the device can directly control groups of other Z-Wave™ devices on over- and undershooting a set temperature and/or humidity parameter.This can be used to establish control loops for temperature and humidity. This product supports Security 2 Command Class.
Engineering Specification 2 Specifications 2.1 Structural Characteristics Parameter Value Product Identifier ZW027 Dimensions 34x34x16 mm Color White IP Class IP 20 Usage Indoor 2.2 Hardware Characteristics Parameter Value Z-Wave Module ZGM130S Z-Wave TX Power Max:13dBm Z-Wave Antenna Distance 40m(Indoor)/150m(outdoor) Indicator Light 2 red ,2 green Battery Type 1*CR2477 Work Current 15mA(wake up), 20mA(Semd message) Standby Current 4uA 2.
Engineering Specification 3 Quick Start 3.1 How to add the product The following will step you through adding the product to your Z-Wave network. Note: When powered, the product will indicate Z-Wave status with the LED: • Red LED blink 5 seconds and then off - the product is not added to any Z-Wave network. • Green LED light on 1 second - the product is already added to the Z-Wave network. 3.1.1 Classic inclusion 1. Power the product. 2.
Engineering Specification 1. Make sure the product is powered. 2. Press and hold the button for at least 10s, and then Factory Reset is performed. The product will issue a Device Reset Locally Command via its Lifeline to notify the Lifeline destination that the product has been reset to its factory default state. And it will perform the reset operation regardless of whether or not the delivery of the Device Reset Locally Notification is successful.
Engineering Specification 4 Software Function Definition 4.1 Supported Command Classes In order to increase interoperability with legacy controlling nodes, this device can reply to Manufacturer Specific Get Commands received non-securely if it was granted the S0 network key as its highest Security Class.
Engineering Specification Installer Icon Type 0x0C00 (ICON_TYPE_GENERIC_SENSOR_NOTIFICATION) User Icon Type 0x0C10 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_WEATHER_ALARM) 4.4 Manufacturer Specific Parameter Value Manufacturer ID 1 0x03 Manufacturer ID 2 0x71 Product Type ID 1 0x00(EU), 0x01(US), 0x02(AU) Product Type ID 2 0x02(PRODUCT_TYPE_ID_SENSOR) Product ID 1 0x00 Product ID 2 0x09 4.
Engineering Specification 4.7 Notification Notification Type Notification Events Heat Alarm 0x04 Power Management 0x08 Weather Alarm 0x10 4.8 Description State Idle 0x00 Issured when overheat or underheat alram removed. Overheat detected 0x02 Issured when detect temperature is higher than set value by Configuration parameter 5 . Underheat detected 0x06 Issured when detect temperature is lower than set value by Configuration parameter 6.
Engineering Specification 0 Disable 1~100 0.1~10 degree Parameter 0x02 (2) Name Minimum humidity change to report Info Trigger humidity report to lifeline. Properties Size 1 Min Value 0 Format Unsigned Integer Max Value 20 Read-only False Default Value 5 Altering capabilities False Advanced False Description The check interval time is set by configuration parameter 3.
Engineering Specification Properties Size 2 Min Value 0 Format Unsigned Integer Max Value 1000 Read-only False Default Value 0 Altering capabilities False Advanced False Description Value Function 0 Disable 1~1000 0.1~100 degree Parameter 0x06 (6) Name Temperature Lower Watermark value Info Below value send BASIC Set to Group3.
Engineering Specification Description Value Function 0 Disable 1~90 1%~90% Parameter 0x09 (9) Name Low Temperature Trigger BASIC Set Send Info Set BASIC Set value send to Group3.
Engineering Specification Properties Size 1 Min Value 0 Format Unsigned Integer Max Value 255 Read-only Fasle Default Value 0 Altering capabilities Fasle Advanced Fasle Description Value Function 0~255 Basic Set Value Parameter 0x0D (13) Name Offset value for Mould danger alarm Info Increase the humidity threshold.
Engineering Specification Format Unsigned Integer Max Value 255 Read-only False Default Value 15 Altering capabilities False Advanced False Description Value Function 1~255 1~255 minutes Parameter 0x40 (64) Name Temperature Scale Info Set the temperature scale.
Engineering Specification 1431655765 Factory Reset the product and remove it from the network. other Reset Configuration Parameter to factory setting. FCC Caution. a. 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation b.15.