AEOTEC User Manual Table of Content 1 OVERVIEW ..................................................................................................................................................................... 1 2 SPECIFICATIONS ............................................................................................................................................................. 2 3 4 2.1 Structural .............................................................................................
AEOTEC User Manual 1 OVERVIEW The AEOTEC Water Sensor 7 Pro is a sensor, which detects water leakage, measures temperature and humidity. The sensor is easily retrofittable. Thanks to its slim design the AEOTEC Water Sensor 7 Pro can be installed in any bathroom, behind a kitchen sink or in any other tight space. The sensor just has to be installed on the wall and the sensor probe must be put on the floor.
AEOTEC User Manual 2 SPECIFICATIONS 2.1 Structural Parameter Value Product Identifier ZWA019 Dimensions 28x95x35mm Weight Main Part: 20g Water Probe: 3g Color White Usage For indoor use. Operating Temperature 32~104°F (0~40°C) Relative Humidity 8%~80% 2.
AEOTEC User Manual Association Support. Refer to Section 4.7 Association Group Info. Factory Reset Support. Refer to Section 3.7 How to factory reset. Power-down Memory Support. All command settings will stay unchanged even power down. Sensor State Report Support. Send out notification via Group 1 when Water Leakage Start or Stop. Control other product Support. Control other Z-Wave product directly via Association Group 2 when water leakage state change Start or Stop.
AEOTEC User Manual 3 QUICK START 3.1 Important safety information Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions.
AEOTEC User Manual 3.7 How to factory reset This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable. Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the GREEN LED blinks once. 3.8 Safety Warning for Batteries The product contains batteries.
AEOTEC User Manual 4 SOFTWARE FUNCTION DEFINITION 4.1 User Behavior Interaction User behavior Out of the Z-Wave network In the Z-Wave network Power OFF Cut the power. Cut the power. Power ON Send Inclusion Requests for SmartStart Learn Mode. LED will flash red 5 times, which means it ’s out of the Z-Wave network. Send Wake Up Notification. LED will become flash green once, and device will wake up for 15 seconds.
AEOTEC User Manual reset to its factory default state. And it will perform the reset operation regardless of whether or not the delivery of the Device Reset Locally Notification is successful. 4.
AEOTEC User Manual 4.6 Version Parameter Value Z-Wave Protocol Library Type 0x03 Z-Wave Protocol Version 0x07 Z-Wave Protocol Sub Version 0x0E Firmware 0 Version 0x02 [Z-Wave Chip Firmware Version] Firmware 0 Sub Version 0x00 [Z-Wave Chip Firmware Sub Version] Hardware Version 0x01 Number of firmware targets 0x00 4.
AEOTEC User Manual Binary Sensor 4.9 Sensor Value Description Water Sensor Type 0x06 0xFF Water leakage Detected Water 0x06 0x00 Water leakage does not detect 4.10 Multilevel Sensor Sensor Type Temperature Relative Humidity 0x01 0x05 Support Scale Measure Range Celcius (°C) -10 to 65°C (+- 1°C) Fahrenheit (°F) 14 to 146°F (+- 1.8°F) Percentage value (%) 0 to 80% RH +- 3% 4.