AEOTEC User Manual User Manual Door/Window Sensor 7 Pro
AEOTEC User Manual REVISION RECORD Version Date Brief description of changes 0.1 2021.10.08 First revision.
AEOTEC User Manual Table of Content 1 OVERVIEW ..................................................................................................................................................................... 1 2 SPECIFICATIONS ............................................................................................................................................................. 2 3 4 2.1 Structural .............................................................................................
AEOTEC User Manual 1 OVERVIEW The AEOTEC Door/Window Sensor 7 Pro is a sensor, which detects if your window is opened, closed or tilted. The sensor is easily retrofittable. Furthermore, the AEOTEC Door/Window Sensor can include other sensors by being connected with other binary sensors like NTC contacts, microswitches or flood sensors. Thanks to its slim design the AEOTEC Door/Window Sensor 7 Pro can be installed unflashy on every window. The sensor just has to be installed on the window casement.
AEOTEC User Manual 2 SPECIFICATIONS 2.1 Structural Parameter Value Product Identifier ZW012 Dimensions 28x95x35mm Weight Main Sensor: 20g Magnet Sensor: 3g Color White Usage For indoor use. Operating Temperature 32~104°F (0~40°C) Relative Humidity 8%~80% 2.
AEOTEC User Manual Association Support. Refer to Section 4.7 Association Group Info. Factory Reset Support. Refer to Section 3.7 How to factory reset. Power-down Memory Support. All command settings will stay unchanged even power down. Sensor State Report Support. Send out notification via Group 1 when Magnet is away or near. Control other product Support. Control other Z-Wave product directly via Group 2 when Magnet is away or near .
AEOTEC User Manual 3 QUICK START 3.1 Important safety information Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions.
AEOTEC User Manual 3.5 How to remove the product 1. Open the housing. 2. Press the tamper on the side of the appliance three times quickly. 3.6 How to manually trigger Wake Up 1. A single click on the button will wake up the device. 2. Repower on will wake up the device.
AEOTEC User Manual Screw Terminal The product must support the interconnection of external binary sensors as well as actuators and drycontacts. The product allows interconnection with external sensors/actuators via 3-pin screw terminals with the following pinout: • #1: Ground • #2: Digital Input • #3: VCC (direct battery supply) VCC + Ground terminals can be used to externally power the sensor with a 3.6V battery or special power adapter (which is not included in the scope of delivery).
AEOTEC User Manual 4 SOFTWARE FUNCTION DEFINITION 4.1 User Behavior Interaction User behavior Out of the Z-Wave network In the Z-Wave network Power OFF Cut the power. Cut the power. Power ON Send Inclusion Requests for SmartStart Learn Mode. LED will flash red 5 times, which means it’s out of the Z-Wave network. Send Wake Up Notification. LED will become flash green once, and device will wake up for 15 seconds.
AEOTEC User Manual The device will issue a Device Reset Locally Command via its Lifeline to notify the Lifeline destination that the device has been reset to its factory default state. And it will perform the reset operation regardless of whether or not the delivery of the Device Reset Locally Notification is successful. 4.
AEOTEC User Manual Product ID 1 0x00 Product ID 2 0x0C 4.6 Version Parameter Value Z-Wave Protocol Library Type 0x03 Z-Wave Protocol Version 0x07 Z-Wave Protocol Sub Version 0x0C Firmware 0 Version 0x01 [Z-Wave Chip Firmware Version] Firmware 0 Sub Version 0x00 [Z-Wave Chip Firmware Sub Version] Hardware Version 0x01 Number of firmware targets 0x00 4.
AEOTEC User Manual Tilt 0x0B 0x00 / 0xFF tilt event 4.10 CENTRAL SCENE When activated by configuration parameter #14 the device can perform as a scene controller. Digital + VCC is used to connect the scene button.
FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.