Warning Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. Certifications (regional): Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the United States and other countries FCC ID: XBAFT100-D MULTISENSOR Model: FT100-D Version: 501010000001-AA www.aeotec.com View the expanded manual: http://aeotec.
THIS EQUIPMENT.SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation.
intellectual property rights arising from or in connection with the products, except to the extent that such infringement exists as a result of Aeon Labs' manufacturing processes. IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war, strikes, fires, other catastrophes, misuse, misapplication, storage damage, negligence, electrical power problems, or modification to the Products or its components. Aeon Labs does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein.
3V, 1500mAh). Operating Temperature: 0 C to 40 C. Measured Temperature Range: -10 C to 50 C. Accuracy: ±0.5 C . Humidity Range: 20%RH to 80%RH. Accuracy: ±5%RH (at 25 C ). Lighting: 0 LUX to 1000 LUX. Motion Sensitivity: 3 meters to 5 meters. Water Proofing: IP20. Wireless Range: Up to 500feet/150 metres outdoors. 6 Warranty.
For a battery powered installation; 1. Remove the rear part of your sensor as shown in the previous step 1. 2. Insert CR123A batteries oriented according to the picture below. Your MultiSensor is now powered on. Security or Non-security feature of your MultiSensor in Z-wave network. If you want your MultiSensor as a non-security device in your Z-wave network, you just need to press the Action Button once on MultiSensor when you use a controller/gateway to add/include your MultiSensor.
Parameter 111-113 [4 byte decimal] can be configured through your gateway in case the default settings of your MultiSensor are not what you desire. Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will set the interval for Group 2 (parameter 102), and parameter 113 will set the interval for Group 3 (parameter 103). As an example, you have set parameter 101 to 227 which will report all of the sensors, and you want to report it every 1800 seconds.
seconds, then inclusion has been successful. If the LED blinks when the button is pressed, the inclusion has been unsuccessful and you should repeat the above steps. 5. Press any button on your Minimote to return it to standard operating mode. Selecting a location for your MultiSensor. MultiSensor can bring its intelligent readings to many locations of your home which includes outside of your home.
For example, this parameter setting is initially set to 240 which is the delay time in 4 minutes or 240 seconds.You may set the value to the desired Motion Sensor delay time to any amount of seconds as you like. So if you want the time out to be 5 minutes after the Motion Sensor is triggered, set this parameter to the value of 300. Setting the sensitivity of your MultiSensor.
For optimal performance, your MultiSensor should NOT be mounted directly on or near metal framing or other large metallic objects. Large metal objects may weaken the Z-Wave wireless signal. If selecting an outdoor location, it’s important to position your MultiSensor in a sheltered location. It is best if your MultiSensor is not directly exposed to rain, and is important that the humidity venting on your MultiSensor never is. Physically install your MultiSensor.
Battery Holder 1. If your Z-Stick is plugged into a gateway or a computer, unplug it. 2. Take your Z-Stick to your MultiSensor. 3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release. 4. Press the Action Button on your MultiSensor. 5. If your MultiSensor has been successfully removed from your network, its LED will blink when you press the Action Button on the MultiSensor.
Advanced functions. Lock Changing batteries. Your MultiSensor has built in battery level detection. It will automatically report its battery level to the associated controller/ gateway throughout its life until the battery is fully drained and needs replacing. The battery status will often be displayed in the user interface of the controller/gateway. Unlock Screw hole 5.