Modicon 512/612 Micro PLC Hardware User Manual 890 USE 145 00 Ver 1.
Contents General Hardware Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Hardware Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PLC Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Memory Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Memory Backup Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Hardware Characteristics Hardware Characteristics On-board CPU, memory, fixed I/O circuitry, and power supply 16 MHz CPU speed for handling I/O throughput A built-in time-of-day clock A parallel expansion port for up to three racks of A120 I/O modules 24 VDC high-speed inputs that can be configured to operate as dedicated hardware interrupts and/or a user-configurable counter/timer/interrupt input Two RS-232 ports, comm 1 and comm 2, for communication with programming devices and with ASCII input/di
PLC Operating Modes The PLCs can operate in any one of three modes: + -- As a single PLC—i.e., a stand-alone programmable control system As a parent PLC on an I/O expansion link—with the ability to access the fixed I/O resources of the PLC(s) in child operating mode on the link As a child PLC whose fixed I/O resources can be accessed by the parent on an I/O expansion link Note Whenever A120 I/O is used in a child PLC, the logic that controls the A120 I/O must be run in the child.
If you are using Flash RAM backup, save the changes you make in your program and/or system configuration at the end of each edit session. The Save to Flash command is issued from your panel software. Whenever PLC power is lost and then restored, the system firmware first attempts to restore any battery-backed memory.
General Hardware Overview Front View of a 512 PLC* Terminal block for fixed discrete and hardwired inputs Captive screw for the input terminal block Captive screw for the input terminal block Battery cover PLC status display with LED indicators Five terminal screws for external power connection J1 screw for signal ground-to-chassis ground J2 screw for 120 of the PLC Captive screw for the output terminal block W termination Captive screw for the output terminal block Terminal block for fixed discrete
Use a Philips #2 screwdriver to make the field wire connections to the terminal screws, then push the terminal blocks back on the PLC base. The J1 and J2 Screws Two factory-set screws are installed on the front of the unit. The J1 screw is located below the power connectors on the left front of the unit, and the J2 screw is located below the PLC status display on the right front of the unit.
The label affixed to the left front of the PLC indicates the power wiring scheme. Model 110CPU51200, 110CPU61200, 110CPU51203, 110CPU61204, and 110CPU61203 PLCs use a 24 VDC external power source, wired like this: 24 VDC Model 51202 PLCs use a 230 VAC external power source, wired like this: L 1 230 VAC 2 1 3 2 N 4 3 5 24 RET 4 The labels for the power source terminal connections are in red lettering.
PLC Status Display The display panel on the front of the Micro PLCs uses light-emitting diodes (LEDs) to indicate the health and status of the unit’s CPU, battery, communication ports, and fixed I/O points.
Bottom Isoview of the PLC comm 1 (RJ45) port comm 2 (RJ45) port I/O exp link (RJ11) port 30-pin A120 I/O expansion receptacle A120 I/O Expansion Port A dedicated A120 I/O parallel expansion port is located on the right side of the unit. It is a 30-pin, dual-row receptacle with locking tabs. It will accept the connector on the left side of a DTA 201 or DTA 202 rack, which houses the A120 I/O modules.
Fixed Analog I/O in the 612 Models The 110CPU61200, 62103 and 61204 PLCs have the additional feature of fixed analog inputs and outputs. The analog I/O is labeled across the lower left front of the unit assembly, the inputs labeled 21 ... 10 from left to right and the outputs labeled 9 ... 1 left to right.
Analog inputs 21 20 19 18 17 16 15 14 13 12 11 10 Analog outputs 9 8 7 comm 1 RS-232 port 6 5 4 3 comm 2 RS-232 port Exp. network RS-485 port 2 1 A Bottom View of a 612 CPU Unit Two analog connectors are provided with the 612 PLCs—a 12-pin analog input connector and a 9-pin analog output connector. Each pin number is displayed on the connector.
Base Unit Specifications Electrical Input voltages 120 VAC input 230 VAC input 24 VDC input 96 ... 132 V RMS, 47 ... 63 Hz 192 ... 264 V RMS, 47 ... 63 Hz 19.2 ... 30.0 VDC Output voltage 24 VDC output 20.5 ... 29.0 VDC @ .15 A maximum Output ripple and noise 24 VDC output 2.
Part Number I/O and CPU Description Base Unit 6 or less Outputs ON Base Unit Add if More than 6 Hand--Held Outputs ON is Used Add if PAB is Used 110CPU51200 DC Relay CPU 24V .30 .50 .05 .125 110CPU61200 DC Relay CPU 24V .30 .50 .05 .125 110CPU61204 DC Relay CPU 24V .30 .50 .05 .125 110CPU51203 DC/DC FET CPU 24V .25 .27 .05 .125 110CPU61203 DC/DC FET CPU 24V .25 .27 .05 .
Input Power Specifications (continued) (Values in VA) Part Number I/O and CPU Description Base Unit 6 or less Outputs ON Base Unit Add if More than 6 Hand--Held Outputs ON is Used Add if PAB is Used 110CPU51201 115VAC/Triac CPU 115V 21.0 23.1 2.1 5.25 110CPU51202 230VAC/Triac CPU 230V 21.0 23.1 2.1 5.25 Input voltage fuses AC inputs DC inputs Power for external devices for a programming panel for A120 I/O expansion 14 1/ 4 A SB in each primary input transformer 1.
Environmental Operating Temperature 0 ... 60 degrees C Storage Temperature --40 ... +85 degrees C Relative Humidity 95% noncondensing Altitude 3800 m (15,000 ft) Shock 30 g for 11 ms, 3 pulses/axis for up to 18 pulses Vibration 10 ... 62 Hz @ .075 mm displacement amplitude, 62 ... 500 Hz @ 1 g Duration: 23 min @ 2 sweeps/axis on 3 mutually orthogonal axes at a rate of 1 octave/min Dimensions Height (including I/O terminal blocks): Width: Depth: Weight 158.75 mm (6.
Optional Hardware Part Numbers RS-232 communication cable assemblies (with RJ45 connectors on both ends) 1 m (3 ft) 110XCA28201 3 m (10 ft) 110XCA28202 6 m (20 ft) 110XCA28203 RS-485 I/O expansion link cable assemblies (with RJ11 connectors on both ends) 61 cm (2 ft) 110XCA17101 3 m (10 ft) 110XCA17102 6 m (20 ft) 110XCA17103 16 1000 ft reels of flat cable Eight-position (for RS-232) Six-position (for RS-485) 490NAA00010 490NAA00020 RJ45 connectors (20/box) RJ11 connectors (20/box) 490NAD00010 490NAD00
Partial Sampling of Available A120 I/O Modules Discrete Input Modules 8 point 230 VAC 8 point 115 VAC 8 point 115 VAC 16 point 24 VDC (isolated) 16 point 24 VDC (non--isolated) 16 point 24 VDC Fast Response 16 point 115 VAC AS-BDEP-208 AS-BDEP-209 AS-BDEP-210 AS-BDEP-216 AS-BDEO-216 AS-BDEP-220 AS-BDEP-218 Discrete Output Modules 4 point Relay 8 point Relay 8 point 115 VAC 8 point 24-230 VAC 16 point 115 VAC 16 point 24 VDC (isolated) 16 point 24 VDC AS-BDAP-204 AS-BDAP-208 AS-BDAP-209 AS-BDAP-210 AS-BDA
Fixed I/O Specifications 110CPU51200/61200 Field Wiring (under 24 VDC power) Fixed Discrete I/O Topology I/O Type Number of I/O Points 24 VDC inputs Number of Groups 16 24 VDC user-selectable counter/interrupt 1 24 VDC dedicated high-speed interrupts 2 2 groups of 8 1 group of 3 Relay outputs 2 groups of 4 and 4 individually isolated 12 with Source-configured 24 VDC Inputs 24 V common Group B common 24 V common Group A common 24 VDC 24 VDC .
with Sink-configured 24 VDC Inputs Cnt/ Int 2 int Int 1 .16 A Fuse .
110CPU51201 Field Wiring (under 115 VAC power) Fixed I/O Topology I/O Type Number of I/O Points 115 VAC inputs Number of Groups 16 2 groups of 8 24 VDC user-selectable counter/interrupt 1 24 VDC dedicated high-speed interrupts 1 Triac outputs 8 2 groups of 4 4 individually isolated 1 group of 2 Relay outputs AC Hot AC Neutral In In In In In In 16 15 14 13 12 11 .
110CPU51202 Field Wiring (under 230 VAC power) Fixed I/O Topology I/O Type Number of I/O Points 230 VAC inputs Number of Groups 16 24 VDC user-selectable counter/interrupt 1 24 VDC dedicated high-speed interrupts 1 2 groups of 8 1 group of 2 Triac outputs 8 Relay outputs 4 2 groups of 4 individually isolated AC Hot AC Neutral AC Hot AC Neutral In In In In In In In In 16 15 14 13 12 11 10 9 .
110CPU51203/61203 Field Wiring (under 24 VDC Power) Fixed Discrete I/O Topology I/O Type Number of I/O Points 24 VDC inputs Number of Groups 16 24 VDC user-selectable counter/interrupt 1 24 VDC dedicated high-speed interrupts 2 24 VDC (FET) outputs 2 groups of 8 1 group of 3 12 3 groups of 4 with Source-configured 24 VDC Inputs 24V common +24V 24V common +24V Group B common .
with Sink-configured 24 VDC Inputs 24 V Common +24 V .16 A Cnt/ Int int 2 Int 1 24 V Common Group B common In In In In 16 15 14 13 22 21 In In In In 12 11 10 9 20 19 18 17 16 15 14 13 12 11 10 User-selectable Dedicated Counter or interrupts Cnt/int com interrupt .
115 VAC Inputs Electrical Characteristics ON level ON current @ 120 VAC OFF level 79 ... 132 VAC with a maximum source impedance of 6.2 kW @ 60 Hz 10 mA 0 ... 20 VAC Maximum OFF state input current Minimum ON state input current 1.7 mA @ 20 V 6.
230 VAC Inputs Electrical Characteristics ON level OFF level 164 ... 253 VAC with a maximum source impedance of 16 kW 0 ... 40 VAC ON state input OFF current 7 mA @ 230 VAC, 50 Hz 1.2 mA maximum @ 40 VAC Maximum OFF state current 1.2 mA @ 40 VAC Minimum ON state current 5.
24 VDC Inputs Electrical Characteristics for Source (True High) Inputs ON level 15 ... 30 VDC, source impedance < 1.5 kW OFF level 0 ... 5 VDC Minimum ON state input current 3.4 mA @ 15 VDC Maximum OFF current .6 mA @ 5 V Maximum input impedance 7.8 kW when OFF 3.
Electrical Characteristics for Sink (True Low) Inputs ON level Source ground to (source voltage -- 15 V) OFF level Source voltage to (source voltage -- 5 V) Minimum ON state input current 3.4 mA with 20 ... 30 V source Maximum OFF current .7 mA with 20 ... 30 V source Maximum input voltage 30 VDC Maximum input impedance 7.8 kW when OFF 3.
Circuit Characteristics Simplified schematic Field side 28 Logic side Isolation Method Channel-to-bus Group-to-group Opto-coupler 1780 VAC, 2500 VDC 1780 VAC, 2500 VDC Response time ON®OFF OFF®ON 2 ms 2 ms Maximum wire length 100 m Wire size 14 AWG 512/612 Modicon Micro PLCs 890 USE 145 00
User-selectable High-speed Counter/interrupt Inputs Electrical Characteristics ON level 15 ... 30 VDC OFF level 0 ... 5 VDC Minimum ON state input 6 mA @ 24 VDC Maximum OFF current 0.7 mA @ 5 V Input impedance 15.8 kW when OFF 1.95 kW when ON @ 24 VDC Current draw 12.3 mA @ 24 VDC Typical impedance curve 25 V INPUT VOLTAGE 20 V 15 V 10 V +5 V 0 mA 2 mA Note We recommend the use of three-wire proximity switches on these inputs.
Circuit Characteristics Simplified schematic Field side Logic side Interrupt/counter 5V Com Isolation Method Channel-to-bus Group-to-group Opto-coupler 500 VDC 500 VDC Addressing 1 register in Maximum cable length 50 m Response time OFF®ON ON®OFF 10 ... 20 ms 10 ...
Dedicated High-speed Interrupt Inputs Electrical Characteristics ON level 15 ... 30 VDC OFF level 0 ... 5 VDC Minimum ON state input 6 mA @ 15 VDC Maximum OFF current 0.3 mA @ 5 V Maximum input impedance 15.8 kW when OFF 1.95 kW when ON @ 24 VDC Current draw 12.3 mA @ 24 VDC Note We recommend the use of three-wire proximity switches on these inputs.
Relay Outputs Electrical Characteristics Working voltage range (for all Micro types) 24 ... 30 VDC 24 ... 250 VAC Maximum load current 2 A/channel Surge current 20 A for 1 cycle VA rating 500 VA (switching) Minimum load current 20 mA Maximum switching rate 5 Hz Required external fuse size User-installed 3 A fuse—e.g. Bussman GMA-V-3.
Circuit Characteristics Simplified schematic Logic side Field side 5V Varistor 280 VAC Isolation Channel-to-bus Group-to-group 1780 VAC, 2500 VDC 1780 VAC, 2500 VDC Mechanical operating cycles 20,000,000 Surge withstand capability 4 kV Response times ON®OFF OFF®ON 10 ms 10 ms Maximum wire length 100 m Wire size One wire Two wires 14 AWG 20 AWG Using Relay Outputs with Inductive Loads The mechanical relay outputs in Micro controllers must be provided with additional protection when connected
Inductive AC Load OUTPUT * 0.47 mf * 50 W 230 AC SOURCE COMMON *Minimum voltage rating of 400 VAC. OUTPUT Inductive DC Load Clamping Diode* + 24VDC SOURCE -- COMMON *Diode must be a minimum of 2A, continuous, and greater than two times the maximum rated load voltage.
Triac Outputs Electrical Characteristics Working voltage Continuous range 24 ... 132 VAC for the -01 Models 24 ... 250 VAC for the -02 Models 500 VAC for 1 cycle Maximum Frequency of operation 47 ... 63 Hz Maximum load current 0.5 A/channel Surge current 5 A for 1 cycle Minimum load current 50 mA Maximum OFF state leakage current 1.5 mA ON state voltage drop 1.5 V Maximum switching rate 20 Hz Static DV/DT 300 V/ms Required external fuse size User-installed 0.8 A fuse—e.g., Bussman GMA-V-.
Circuit Characteristics Simplified schematic Live Logic side Field side Load Varistor 280 VAC Group Common 36 Isolation Method Channel-to-bus Group-to-group Opto-coupler 1780 VAC, 2500 VDC 1780 VAC, 2500 VDC Response times ON®OFF OFF®ON 8 ms 8 ms Maximum wire length 100 m Wire size One wire Two wires 14 AWG 20 AWG 512/612 Modicon Micro PLCs 890 USE 145 00
24 VDC (FET) Outputs Electrical Characteristics Working voltage range Continuous Maximum 20 ... 30 VDC 32 V for 10 s 56 V for 1.5 ms ON current (@ 60 degrees C) 0.5 A / channel 2 A / group 6 A total Surge current 5 A for .5 ms @ 6 pulses / min Minimum load current 10 mA Maximum OFF leakage current 1 mA @ 30 V ON state voltage drop .4 V @ .5 A Maximum switching rate 4 Hz inductive Recommended external fuse size User-installed 1.5 A fuse—e.g., Bussman GMA-V-1.
Circuit Characteristics Simplified schematic Field side +24 V Power IN Logic side VCC To Load +24 REF 38 Isolation Channel-to-bus Group-to-group 1780 VAC, 2500 VDC 500 VAC Response times ON®OFF OFF®ON 1 ms 1 ms Maximum wire length 100 m Wire size 14 AWG 512/612 Modicon Micro PLCs 890 USE 145 00
Analog Inputs Electrical Characteristics Input channels Number Types 4 Current inputs, 20 mA full scale Voltage inputs, 10 V full scale Input ranges +10 V, 0 ... 10 V, 4 ... 20 mA Input filter Single-pole low-pass, --3 dB frequency of 10 Hz (+20%) Input resistance Current mode Voltage mode 250 W (+0.
Input Circuit Characteristics Simplified Schematic Field Connections Jumper Current Input Input 1 (+) Sense 1 4 ... 20 mA Input 1 (--) Input 2 (+) Sense 2 Input 2 (--) Voltage Input Input 3 (+) Sense 3 Input 3 (--) Input 4 (+) Sense 4 Input 4 (--) 10 11 250 W .
Analog Outputs Electrical Characteristics Output channels Number Types Group Isolation 2 Current outputs Voltage outputs 1000 VAC RMS (60 Hz), 1 min. maximum (Analog outputs are isolated from analog inputs, input power, discrete I/O, and communication ports.) 1000 VDC, 1 min. maximum Current range Loop supply voltage Maximum Minimum Max loop resistance Voltage range Output loads Conversion Resolution 4 ... 20 mA 30 V 12 V Vloop -- 7 V = Max. R .02 0 ... 10 V 10 mA maximum .
Output Circuit Characteristics Simplified Schematic Field Connections 1 0 ... 10V 2 ZL 3 DC 4 DC 5 D/A 6 W V REF 250 .1% ZL + 4 ... 20 mA 7 24V 8 -- 9 CPU D/A Isolation barrier W 250 .1% 1 = Channel 1, Volt out 2 = Channel 1 RTN * 3 = Channel 1 4 = Voltage monitor 5 = Channel 2, Volt out 6 = Channel 2 RTN * 7 = Channel 2 8 = Voltage monitor 4 ... 20 mA output 4 ... 20 mA output Note -- All RTN’S are common inside box. Therefore both outputs are referenced to same point.
Installation Guidelines The Model 512 and 612 PLCs offer a straightforward plug-and-play installation capability. bottom—to secure the unit to a flat surface such as a 1/4 in metal plate in a NEMA cabinet. To access these through-holes, remove the I/O terminal blocks at the top and bottom of the unit. The through-hole locations are shown in the dimension drawing below.
Unit Dimensions 76 mm (3 in) 158.75 mm (6.
Mounting Units on DIN Rail The PLC can be mounted on a DIN EN 50 022 carrier rail. The DIN rail can be attached to a flat mounting surface or hung on an EIA rack or in a NEMA cabinet. surface. 7.5 mm 15 mm If the PLC uses its A120 I/O expansion capability, the unit and the backplanes that house the A120 modules must be mounted on DIN rail. Mounted DIN Rail Profiles 35 mm DIN EN 50 022 Carrier Rail DIN rail may have either 7.
Installing a PLC on DIN Rail Step 1 Remove the output terminal block on the bottom of the PLC to gain access to the three clips shown in (1). Pull the clips down before placing the unit on the DIN rail. 4a 4b 1 Step 2 Place the clip on the top of the PLC housing over the top of the DIN rail and drop the unit into place. 2 Spacer Step 4 Push the three clips on the bottom of the unit up to lock the unit onto the DIN rail, then snap the output terminal block back into place.
135 mm (5.31 in) 940 mm (37 in) 225 mm (8.85 in) ~ 10 mm (.39 in) Modicon Micro PLC DTA 201 Backplane DTA 201 Backplane DTA 201 Backplane DIN Rail Length to Support A120 I/O Expansion on a Modicon Micro A DIN rail must be at least 255 mm (10.04 in) long to support a single PLC. To support a PLC with three DTA 201 five-slot backplanes, a DIN rail needs to be at least 940 mm (37 in) long. 39 mm (1.5 in) minimum 117 ... 195 mm (3 ...
Installing the Optional Battery or Battery Capacitor Memory backup may be provided by either a lithium battery assembly (110XCP98000) or a battery capacitor assembly (110XCP99000). Both assemblies include wire leads and a 3-position feed-thru receptacle connector. They may be ordered as options from Modicon or from your local distributor. Installing a Battery or Battery Capacitor Assembly Step 1 With a slotted screwdriver, remove the battery cover from the Micro PLC.
Serial I/O Expansion Link Up to five PLCs can be interconnected on a serial I/O expansion link. The link contains one parent PLC and from one ... four child PLCs. I/O Expansion Link Characteristics 2 ...
Front of the unit RJ11 Connector at the RS-485 Port Back of the unit RS-485 Port Location on the Bottom of a PLC Serial I/O expansion establishes a parent-child relationship between the units on the link. One Micro PLC acts as the parent—its I/O processor can access the fixed I/O resources of all the child PLCs on the link, and its CPU can perform all the logic-solving activities for the fixed I/O resources on the link. Each child PLC on the link must have a unique numerical address in the range 1 ...
A120 I/O Expansion On the right side of the PLC is a 30-pin connector that allows you to connect the unit to a secondary backplane (or rack) containing A120 I/O modules. This expansion capability can support up to 15 A120 I/O modules (depending on the modules’ combined power draw) in up to three DTA racks. A 512/612 PLC in any operating mode—single, parent, or child—can use A120 I/O expansion.
module, which draw 60 mA and 88 mA, respectively—you could expend most of your available power with a few modules in a single DTA rack. A120 I/O Expansion Racks The DTA 201 backplane is 213.4 mm wide x 142 mm high x 31 mm deep. It has an I/O expansion ribbon cable with 30-receptacle connector on its left side that connects it to the unit prior to it and a 30-pin expansion connector on its right side (the same as the one on the PLC) that enables extension to another backplane. The DTA 202 backplane is 91.
512/612 PLC DTA 202 Rack 1 Rack 2 512/612 PLC DTA 201 Rack 1 Rack 2 512/612 PLC DTA 201 DTA 202 Rack 1 Rack 2 Rack 3 512/612 PLC DTA 201 DTA 201 Rack 2 Rack 3 DTA 201 DTA 201 DTA 202 Rack 2 Rack 3 Rack 4 Rack 1 512/612 PLC Rack 1 512/612 PLC Rack 1 DTA 201 Rack 2 DTA 201 Rack 3 DTA 201 Rack 4 Linear A120 I/O Expansion Layouts 54 512/612 Modicon Micro PLCs 890 USE 145 00
Caution The connectors on the BXT 201 cable are polarized and must be connected properly—the A connector must be attached to the rightmost unit on the top DIN rail and the B connector must be attached to the rightmost unit on the bottom DIN rail. The racks may also be stacked on two DIN rails and connected by a BXT 201 bus extension cable. There may be either one or two racks mounted on each DIN rail.
PLC PLC A Rack 1 DTA 201 A Rack 1 BXT 202 DTA 201 BXT 202 DTA 201 B B Rack 2 PLC Rack 3 Rack 2 DTA 201 DTA 201 PLC A Rack 1 DTA 201 A Rack 1 Rack 2 Rack 2 BXT 202 DTA 201 B BXT 202 DTA 201 B Rack 3 Rack 4 Rack 3 Stacked A120 I/O Expansion Layouts 56 512/612 Modicon Micro PLCs 890 USE 145 00
Connecting the PLC to a Programming Panel A programming panel—for example, the 520VPU19200 Hand-held Programmer* (HHP) or a personal computer running Modsoft programming software—can be connected to the PLC at one of its two RS-232 ports, comm 1 or comm 2.
110XCA20300 9-pin Female Adapter Micro PC-AT Pinouts RJ45 Connector pin 1 1* pin 9 4--40 screw threads RJ45 jack (8x8) 9-pin D-shell 1 DCD TXD 3 2 RXD RXD 4 3 TXD DSR 2 4 DTR GND 5 5 GND 6 DSR CTS 7 7 RTS RTS 6 8 CTS 9 RI chassis ground 8 case of the connector * CAUTION: Pin 1 receives 5 V from the Micro 50.
Index Numbers 115 VAC input specifications, 24, 25 24 VDC (FET) output specifications, with 512/612, 37 24 VDC digital output specifications, 32, 35 512 controller A120 I/O expansion with, 51 base unit specifications, 13 fixed I/O specifications, 18 general hardware characteristics, 3 hardware overview, 6 installation, 43 optional battery/battery capacitor, 48 parent/child concept, 4 PLC status display, 9 serial I/O expansion link with, 49 612 controller A120 I/O expansion with, 51 base unit specifications,
O output specifications 115/230 VAC triacs, 35 24 VDC, 32, 35 24 VDC (FET), 37 relays, 32 P parent/child concept with 512/612, 4 with 512/612 serial I/O, 49 R relay output specifications, 32 S specifications base unit, 13 fixed I/O, 18 T triac output specifcations, 35 60 Index 890 USE 145 00 PR