User Manual for LEO-S Cold Chain Management (TREK-120 & USM-S62) V1.
Contents Contents .............................................................................................................................. 2 Chapter 1 General Information........................................................ 1 1.1 Introduction .................................................................................................... 2 1.2 General Specification ..................................................................................... 2 1.3 Installation flowchart ..........
Chapter 1 General Information 1
1.1 Introduction Advantech Cold Chain Management offer a full function of Temperature and Humidity control analysis in supply chain. This LEO-S CCM Kit can apply in many environments such as hypermarket, food factory, museum, warehouse, medical management, etc. For use with us in-vehicle gateway, our LEO-S can achieve Uninterrupted Real-time Cold Chain Management.
1.
Chapter 2 System Setup 4
2.1 A Quick Tour of the LEO-S CCM Hardware Kit – TREK-120G2 2.1.1 Outlook Battery Cover Power/Status LED Start/Status Button Mounting Alarm LED NFC Antenna Sensor Figure 2 Back View of TREK-120G2 Figure 1 Front View of TREK-120G2 2.1.2 LED behavior Standby Recording Low Battery Over Critical Power/Status LED Green Green Red Green Alarm LED N/A Green N/A Red 2.1.
2.1.4 Battery Replacement Step 1. Step 2. Step 3. Step 4.
2.2 A Quick Tour of LEO-S CCM Hardware Kit – USM110-S62 2.2.1 Outlook 12.0V⎓2.0A Adapter socket RJ-45 Network Socket LTE/Wi-Fi Conductor LTE/Wi-Fi Conductor Figure 5 USM-S62 LTE/Wi-Fi Antenna Side View USB 2.
2.2.2 LED behavior Figure 8 LED Behavior of USM-S62 Power On Initializing Ready Left LED Green Green Orange Cross Orange Right LED Blue N/A N/A 2.2.
Chapter 3 Software Demo Utility Setup 9
3.1 USM-S62 EdgeX-Go installation EdgeX-Go Overview Before we run EdgeX-Go on USM-S62 we must prepare at least 4GB memory size micro SD card. And stored three files into the micro SD card Edgex-go USM-S62 Edgex_installer Edgex-go provide an environment for USM-S62 program, and the program will collect MQTT data from Lo-Ra antenna, final upload to WISE-PaaS. Edgex_installer is a program for automatically start EdgeX service and USM-S62 program. After we insert micro SD card, and power on USM-S62 device.
And will show Ethernet configuration interface. Choose “Change adapter options”. Right click chooses “Properties”. Roll down “The connection uses the following items:”, will find Internet Protocol Version 4 (TCP/IPv4), then double click it.
Set IP address “172.0.0.XXX”, Subnet mask “255.255.255,0”, and click “OK” Download PuTTY from https://drive.google.com/file/d/1SQJit7bIxUo9gMa0CC7ZH_zzCWhD6yoN/view?usp=s haring, after installation, open putty executed file.
Open PuTTY Session with IP address 172.0.0.1 The login user name and password default is root and 1234 And we go to location /mnt/mmc, this location is where the micro SD card located. Syntax root@USM-S62:~# cd /mnt/mmc Display Now let’s executed edgex_installer. Syntax root@USM-S62: /mnt/mmc# ./edgex_installer Display Final, it will display two tips to point out install finish.
3.2 Web-GUI 3.2.1 Login Open your browser (Chrome/ IE/ Edge/ Firefox). Insert “172.0.0.1”, this IP is USM-S62 Mask address. The figure below is the Web-GUI default interface. Insert username and password, and click “Sign in”. Username: root Password:1234 3.2.2 Overview This Web-GUI will contain four parts in each subject on the left side. And each subject has related configure options.
A. Status a. Overview b. Backhaul B. Settings a. Backhaul Network b. DHCP Server c. Configuration d. Firmware upgrade e. Reboot C. LoRa a. Data and Charts b. Management c. LoRa Module F/W Upgrade d. Node Import D.
3.2.3 Firmware Check & Update Method 3.2.3.1 USM-S62 Firmware Version Check At first we get USM-S62 and Start Web-GUI we need to check USM-S62 Firmware version if it is newest. There are two methods to check the firmware, one when you start Web-GUI and login default page. We will see “Firmware Version”. Now is 1.0.2 (2020/9/9). The other method is click “Status” option on the left side.
And click “Overview”. 3.2.3.2 USM-S62 Firmware Update Method If the device firmware is not the newest or have some critical fix of firmware need to update, the new firmware file will upload to google drive and let end user download (Need Advantech related personnel permission). Choose Firmware Upgrade in Settings option.
Then we can select firmware file in the “Select File” subject. After you choose the firmware file that provide from Advantech, it will show file information on the page.
When you press Upload, the USM-S62 firmware will upgrade automatically. And the device will automatically reboot after upgrade. 3.2.3.3 LoRa Module Firmware Version Check In this part we continue from the previous part, we need to check LoRa module firmware version next. Let us check the left side of Web-GUI. There is an option named “LoRa” Click “LoRa” option, it will show four options. Click “LoRa Module F/W Upgrade”.
After click this option there will show an outline named “LoRa Module Firmware Management”, and we can check the firmware version. Now is R1.5.13 (2020/9/9). 3.2.3.4 LoRa Module Firmware Update Method If Lo-Ra module firmware is not the newest or have some critical fix of firmware need to update, the new firmware file will upload to google drive and let end user download (Need Advantech related personnel permission). Click “LoRa” option, it will show four options. Click “LoRa Module F/W Upgrade”.
When we choose Firmware Upload, this page will show the button to let us choose the file to upload. And after you choose the upload file this page will show this file information.
Press Upload button, then press Upgrade, USM-S62 will upgrade Lo-Ra module’s firmware automatically. After upgrade firmware this page will shows that checksum verification is “OK”, and the new firmware version. Just press “Done”.
3.2.4 USM-S62 Change Network ID (Unavailable feature) If customer have two or more gateways and each gateway manage different set of TREK-120G2, then we will need to know how to configure Lo-Ra Module Setting. As the figure above, if we don’t want Set A data connect to the USMS62 on the right side, all we need to do is change the Network ID in the Lo-Ra Gateway page from Lo-Ra management.
When we scrolling down the page, there is a “Database” subject. And we will also see a gear sign click the gear, and press “Edit”. We can change Network ID from this page TREK-120G2 also have own Network ID, gateway Network ID must as same as TREK-120G2. It will never connect if the ID is not the same. Now stage Advantech didn’t allow customer to change their Network ID of TREK-120G2 3.2.5 Insert Node List If we need to connect both TREK-120G2 and USM-S62.
After we prepared node list, now we’re going to insert it to USM-S62. Click “LoRa” option. Click “Node Import” And it will show “Import” outline at right side.
Click “Choose File”, choose the node list file where you download. This file must be “.json” file type. If you have previous node list inside your USM-S62, and we wish to keep that list inside, after choose file do not check “Overwrite” option, just click “Append” If we want to update whole node list, please check the “Overwrite” option, and click “Overwrite”.
Every time we change the configuration of Lo-Ra, Web-GUI will return back to LoRa/Management page, and we must reboot the LoRa module. 3.2.6 TREK-120 Connection Confirm After reboot and login, go to LoRa/Management page, and roll the script down will show us all LoRa node we insert to USM-S62. And wait 3~5 minutes, we will see the TREK-120G2 status below “Status” outline. 3.2.7 Cellular Network Setting (LTE version) 3.2.
3.3 LEO-S TREK-120G2 Configuration Tool (Need TREK-120-ANR) TREK-120G2 is wireless sensor with NFC feature, and we use configuration tool to set our TREK-120G2 and upload data backup data to WISE-PaaS. Connect NFC reader to your laptop or personal computer with Windows OS. Unzip “LeoSetting Tool 1.1.8.zip” (or later version), and open the folder, executed “LeoSettingTool.exe”. When the tool be executed will auto connect to COM port of NFC reader.
Put your TREK-120G2 on the reader, please make sure both “NFC mark” is aligned. NFC mark Click “Detect Sensor” on the upper right corner. After click the tool will show “Sensor detected, downloading information…”, after downloading this message will disappear automatically, please don’t click the “skip” button.
When finished detecting, this tool will show sensor’s information and function settings. Basic information Device ID This ID present sensor ‘s ID, each sensor have their own ID, and user can distinguish them with last 4 numbers. This ID can identify sensor type. APP ID Network ID Network name of gateway and sensor. FW Version This will show firmware version of this TREK120G2 Sensor Mode There are 3 modes of this Sensor mode information 1. Off: Factory default, in this mode user can’t start Sensor. 2.
3.3.1 Basic Settings When click “Export”, this tool can save Function Settings of this TREK120G2. Next time if user need previous setting, you can click “Import” and choose the “.ini” file which we export and save in our computer.
Every time you change “Function Settings” or “Import” function setting user must click “Save to Sensor” to save the setting in to TREK-120G2. When we need to stop TREK-120G2, user can stop the device through click “Stop” button. After click “Detect Sensor” again, and check “Sensor Mode”, will change Running mode to Ready mode.
3.3.2 Sensor Data Put TREK-120G2 on NFC reader, and click “Sensor Data” on the upper of left Into Sensor Data interface, user will see “Upload”, “Export”, “Clean” and “Detect Sensor”, at the upper of right side.
Click “Detect Sensor”, the tool will start to download data in TREK120G2. It’ll take few seconds. After download the blank space will show all data (5000 records) in TREK-120G2.
After detect sensor, you can click “Export” to make these data into .csv file and save it to where user wish to store.
And final you will get an excel report. Microsoft Excel might show ##### in cells when a column isn’t wide enough to show all of the cell contents. Formulas that return dates and times as negative values can also show as #####. To make a column wider to show cell contents in full, double-click the right edge of the column header, or drag it to the width you want.
3.3.3 Upload backup data to Dash board Under certain circumstances, Gateway LoRa module might loss signal and can’t receive data from TREK-120G2, so we made an “Upload” function for TREK-120G2 to make up WISE-PaaS missing data. Open your Setting Tool, and turn to “Sensor Data” page.
In this example, 2020/09/01 10:03:18 this data stored in sensor when gateway didn’t power on. So it didn’t upload to WISE-PaaS. And if you click “Upload” then you can make up this data to WISE-PaaS directly without gateway. 3.3.4 WISE-PaaS Setting 3.
Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.