EPOCH-M1C USER MANUAL Version 1.1 2607 Colorado Blvd. Los Angeles, CA 90041 USA Tel: 323-254-8131 Fax: 323-254-4928 www.adrftech.
Epoch-M1C RF Repeater User Manual V1.1 Version 1.1 (Released September 27, 2006) Information in this document is subject to change without notice. Advanced RF Technologies, Inc. 2002-2006. All rights reserved. Please send comments to: E-Mail: info@adrftech.com Phone: (323) 254-8131 Fax: Address: (800) 313-9345 (323) 254-4928 Advanced RF Technologies, Inc. Attention: Technical Publications Department 2607 Colorado Blvd., Suite 100 Los Angeles, CA 90041 USA www.adrftech.
Epoch-M1C RF Repeater User Manual V1.1 TABLE OF CONTENTS 1. Introduction of Epoch-M1C ................................................................................5 1.1 Overview ......................................................................................................5 1.1.1 1.1.2 1.1.3 Highlights ......................................................................................5 Special Features..............................................................................
Epoch-M1C RF Repeater User Manual V1.1 5 4.2 Common Installation Problems ...................................................................31 Warranty and Repair Policy.................................................................................32 5.1 General Warranty ........................................................................................32 5.2 Limitations of Warranty...............................................................................32 5.3 Limitation of Damages ......
Epoch-M1C RF Repeater User Manual V1.1 1. Introduction of Epoch-M1C 1.1 Overview Epoch-M1C series repeaters enhance in-building wireless coverage in the most effective and cost efficient way. For its intelligent design and versatility, EpochM1C series repeaters are the ideal choice for indoor wireless coverage problems. An Epoch-M1C series repeater can be used as a stand-alone repeater with passive antennas connected to it or it can also be used as a feeder repeater to a DAS (Distributed Antenna System).
Epoch-M1C RF Repeater User Manual V1.1 1. Server Antenna Port One end of the coax cable will connect to the “Server Antenna Port” of Epoch-M1C while the other end of the cable will connect to the server antenna which is pointing towards the intended coverage area. 2. Power LED The Power LED will be lit Green if the power is turned on and will be not lit if the power is turned off. 3. Wireless Modem Access You can manually place or take off the wireless modem. 4.
Epoch-M1C RF Repeater User Manual V1.1 No. NAME Description 1 Cable Connection Active Low 2 External Alarm 1 Active Low 3 External Alarm 2 Active Low 4 External Alarm 3 Active Low 5 External Alarm 4 Active Low 6 GND GND 7 GND GND 8 Open Open 9 Open Open Table 1 – Pin Assignment for AAI 1.1.3 Available Models Epoch-M1C is available in all 850 MHz cellular band combinations.
Epoch-M1C RF Repeater User Manual V1.1 1.2 Warnings and Hazards WARNING! ELECTRIC SHOCK Opening the Epoch-M1C could result in electric shock and may cause severe injury. WARNING! EXPOSURE TO RF Working with the repeater while in operation, may expose the technician to RF electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF electromagnetic fields.
Epoch-M1C RF Repeater User Manual V1.1 WARRANTY Opening or tampering with the Epoch-M1C will void all warranties. NOTE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Epoch-M1C RF Repeater User Manual V1.1 1.3 Epoch-M1C Parts List The Epoch-M1C repeater system includes: PART ID a. Epoch-M1C Repeater b. Screws c. **CD EPOCHMICXX SC01 M100OMS V1.XX01 d. USB Cable USB01 e. Power Cable PWRC01 QUANTITY 1 4 1 1 1 ** CD includes: (1) Software; (2) User Manual; (3) Epoch-M1C Quick Start Guide; & (4) Software & USB Driver Setup Guide. 1.4 Epoch-M1C Software Installation and Requirements 1.4.
Epoch-M1C RF Repeater User Manual V1.1 1.5 Pre-Installation using Epoch-M1C Software Prior to the Epoch-M1C installation, ensure that: a. The USB cable has been connected and proper communication has been established. b. The donor and server antennas are in place. c. The TX and RX communication status LEDs are lit green and blinking periodically on the Status Menu. ** The TX and RX LEDs should blink every 1 second only in the Status Menu.
Epoch-M1C RF Repeater User Manual V1.1 1.6 Step by Step Instructions for Installation 1.6.1 Repeater Setup Figure 2 – Front & Right Side Views of the Repeater 1. Connect the Power Source Make sure that the power switch on the right side of the repeater is turned off before connecting the power cable. Connect the power cable to the AC/DC Power Port as shown in Figure 3.
Epoch-M1C RF Repeater User Manual V1.1 the Epoch-M1C’s USB port (located on the right side of the repeater) and the other end to the PC’s USB port as shown in Figure 2. ** Install the USB driver and the Epoch-M1C Manager Software prior to installation. 5. Turn On the Power for Epoch-M1C Make sure that the donor and server antennas and the power cable are securely connected to the correct ports. located on the right side of the repeater. Turn on the power switch, 6.
Epoch-M1C RF Repeater User Manual V1.1 ** If a wireless modem is not connected, skip steps 12 through 13 and proceed to step 14. 9. Provide SNMP Information Type in the Site ID and the Manager IP address as given to you by the Wireless Provider. Once both the parameters are typed in, you must click “Set” for it to be executed. 10. Check the Modem Connection Verify that the Auto Connection box is checked. 11. Click on Install After the first three steps, click on “Install.
Epoch-M1C RF Repeater User Manual V1.1 CONGRATULATIONS!! The Epoch-M1C Installation Process is Complete. Advanced RF Technologies, Inc.
Epoch-M1C RF Repeater User Manual V1.1 2 User Manual V1.0 using Epoch-M1C Software 2.1 Menu Structure 2.1.1 Window Overview Status Control Install you to monitor the current you to change or adjust the through an automated The Status Window allows settings and status of the Epoch-M1C. The Control Window enables Epoch-M1C’s parameters and settings. The Install Window guides you installation of the Epoch-M1C repeater.
Epoch-M1C RF Repeater User Manual V1.1 2.1.2 Status Window The Status Window is the monitoring window of the Epoch-M1C Software. This window enables the user to monitor the status and settings of the Epoch-M1C. In other words, no parameters can be changed in the Status Window. Window.
Epoch-M1C RF Repeater User Manual V1.1 2.1.3 Control Menu 2.1.3.1 General Setting Window Figure 7 - General Setting Window of the Epoch-M1C Software AGC Mode AGC (Auto Gain Control) adjusts the variable gain of the repeater to ensure a constant specified output power of 20 dBm.
Epoch-M1C RF Repeater User Manual V1.1 Uplink Tracking/Offset Modes Uplink tracking mode enables or disables the Uplink Tracking ON feature that sets the gain in the uplink equaling to the gain in the downlink. The tracking gain offset is the difference between the uplink and downlink gains. For example, if the downlink gain is 80 dB, the Uplink Tracking ON is checked, and the Uplink Tracking Gain Offset is set to 3 dB, the uplink gain would be 77 dB.
Epoch-M1C RF Repeater User Manual V1.1 2.1.3.2 Alarm Setting Window Figure 8 - Alarm Setting Window of the Epoch-M1C Software Heartbeat The Heartbeat is a periodic message sent out to Wireless Provider’s NOC only if the repeater comes with a wireless modem. Control Item Action Setting Value Heartbeat ON/OFF Set Heartbeat Mode ON/OFF Periodic Time Set Heartbeat Time 1 ~ 60 min @ 1 min step Table 4 - Heartbeat Mode and Time Range Heartbeat Mode The Heartbeat ON box is checked by default.
Epoch-M1C RF Repeater User Manual V1.1 Alarm Setting RSSI The RSSI alarm is the minimum RSSI value that the Epoch-M1C requires to ensure optimal coverage. The RSSI alarm will go off when the RSSI is lower than the threshold value (refer to the RSSI value in the Alarm Setting Window). The threshold RSSI value can also be adjusted manually @ 0.5 dB step (range is shown in Table 5 on page 20).
Epoch-M1C RF Repeater User Manual V1.1 2.1.4 Install Window At the time of installation, the installer needs to go to the Install Window of the Epoch-M1C Software. The Install Window will guide the installer through a step by step process to properly install the Epoch-M1C repeater. For setup or installation of Epoch-M1C, go to the Install Window. Figure 9 - Install Window of the Epoch-M1C Software Band As shown on Figure 9, simply click on the desired band. To uncheck a band, click on it again.
Epoch-M1C RF Repeater User Manual V1.1 Repeater Click the “Install” button and the repeater will setup automatically. For information regarding the use of the Epoch-M1C Software during installation, refer to Section 1.7.1 on page 11, “Repeater Installation” (starting at number 9). 2.1.5 System Menu 2.1.5.1 Info Window The Info Window displays the Model Number, Serial Number and Firmware Version of the Epoch-M1C repeater.
Epoch-M1C RF Repeater User Manual V1.1 2.1.5.2 Upgrade Window In order to download the latest repeater firmware, click on the Upgrade Window. The firmware file will be provided by the technical support group from Advanced RF Technologies, Inc. Once the firmware file has been saved on the PC, you would connect the Epoch-M1C repeater to the PC via the USB cable provided. Click on “Open” and locate the firmware file and click on ‘Download.
Epoch-M1C RF Repeater User Manual V1.1 2.2 Using the Epoch-M1C Software 2.2.1 Changing Parameters In changing the parameters of the repeater using the Epoch-M1C Software, note that the values entered into the Epoch-M1C Software are limited to the ranges and modes specified in the Menu Structure section as explained in Section 2.1 on page 15. The chart below shows the parameters that can be changed and the location of each parameter in the Control Menu Structure.
Epoch-M1C RF Repeater User Manual V1.1 Figure 13 - All Alarm Parameters Supported by Epoch-M1C In the event of a hard fail alarm, the control board will shut down the HPA (both uplink & downlink) for 30 seconds and then turn on the HPA to check for a repeated hard fail occurrence. If the hard fail alarm persists for up to four consecutive occurrences, the control board will shut down the HPA for 20 minutes (total of five consecutive hard fails).
Epoch-M1C RF Repeater User Manual V1.1 2.3.2 Downlink (Forward) Uplink (Reverse) Downlink/Uplink Alarms Alarm List Soft Fail Hard Fail Remark RSSI O - Alarms will turn on if the Input Power Overload O - limits specified in the Over Power* O O RSSI O - Input Power Overload O - Over Power* O O value is not within operable Control Alarm Setting Window. Note: The Over Power parameter is fixed and cannot be modified by the user.
Epoch-M1C RF Repeater User Manual V1.1 2.4.2 Default Alarm Setting Setting Value Control Item Downlink Uplink RSSI -95 dBm -110 dBm Input Overload -35 dBm -35 dBm Heartbeat On/Off ON Heartbeat Time 20 minutes Table 10 - Default Alarm Parameter Values of the Epoch-M1C Software Advanced RF Technologies, Inc.
Epoch-M1C RF Repeater User Manual V1.1 3 Maintenance Guide for Epoch-M1C 3.1 Periodic Inspection Checklist Check for loose connections to the repeater and antennas. If connections are loose, make sure that all connections are tightly fastened. Cables and connectors are in good condition. Ensure that the repeater brackets are in good condition and that the repeater is securely fastened. 3.2 Preventive Measures for Optimal Operation 3.2.1 • 3.2.
Epoch-M1C RF Repeater User Manual V1.1 4 Troubleshooting 4.1 Tx & Rx LEDs Tx Rx Blinking Blinking GREEN GREEN Blinking Solid GREEN GREEN Explanation Successful Connection. The Epoch-M1C Software and the repeater are communicating successfully. The repeater is not receiving any commands from the software. In this state, the repeater is either processing or executing a command. Wait for a few seconds for the Rx LED to blink periodically.
Epoch-M1C RF Repeater User Manual V1.1 4.2 Common Installation Problems Problem USB port is not being recognized The power green LED on the front panel is not lit. GUI Software & Laptop - No Communication Status Window – Weak Signal or Possible Solution You would need to install the driver for the USB cable which can be found with the CD that comes with the repeater. Check if the power switch is turned on. Also verify if the power cord is securely connected to the repeater.
Epoch-M1C RF Repeater User Manual V1.1 5 Warranty and Repair Policy 5.1 General Warranty The Epoch-M1C carries a Standard Warranty period of two (2) years unless indicated otherwise on the package or in the acknowledgment of the purchase order. 5.2 Limitations of Warranty Your exclusive remedy for any defective product is limited to the repair or replacement of the defective product. Advanced RF Technologies, Inc. may elect which remedy or combination of remedies to provide in its sole discretion.
Epoch-M1C RF Repeater User Manual V1.1 5.6 Return Material Authorization (RMA) No product may be returned directly to Advanced RF Technologies, Inc. without first getting approval from Advanced RF Technologies, Inc. If it is determined that the product may be defective, you will be given an RMA number and instructions on how to return the product. An unauthorized return, i.e., one for which an RMA number has not been issued, will be returned to you at your expense.
Epoch-M1C RF Repeater User Manual V1.1 Appendix A: Specifications ELECTRICAL SPECIFICATIONS PARAMETERS Frequency Range SPECIFICATIONS DL 869 to 894 MHz UL 824 to 849 MHz Epoch-M1C-FF Epoch-M1C-AF COMMENTS Model 1: Cellular Full Band Model 2: A” + A + A’ Band Sub Band Filtering Epoch-M1C-BF Epoch-M1C-AP Epoch-M1C-BP Operating Frequency Programmable Frequency Error ≤ +/- 0.
Epoch-M1C RF Repeater User Manual V1.1 MECHANICAL SPECIFICATIONS PARAMETERS SPECIFICATIONS Housing (W x H x D) 8.27 x 11.03 x 3.57 inches Housing Material Aluminum & Plastic Weight ≤ 13.22 lbs Connector Type Antenna N-Type (Female) Dry Contact RS-232 (Female) NMS Control USB) Cooling COMMENTS External Convection POWER SPECIFICATIONS PARAMETERS SPECIFICATIONS COMMENTS Main AC Power 100 to 240 VAC Power Adapter shall AC Frequency 45 to 65 Hz Adaptor Voltage & Current 6 VDC / 4.
Epoch-M1C RF Repeater User Manual V1.1 Appendix B: Button Operation Normal Operation Normal Operation Power Off Power On 16 sec Booting Time POWER (off) VFD ALARM (off) Initializing.... 6 sec POWER (Green) VFD ALARM (Red) Display Cycle* The VFD display will disappear 30 minutes after VFD button is pressed. POWER (Green) VFD ALARM (off) If the VFD button is pressed, the display will come up again.
Epoch-M1C RF Repeater User Manual V1.1 Soft Fail Alarm Operation Soft Alarm Operation Power Off Power On 16 sec Booting Time POWER (off) VFD ALARM (off) Initializing.... 6 sec POWER (Green) VFD ALARM (Red) Display Cycle* 4 sec 4 sec POWER (Green) VFD ALARM (Red) Until the condition clears. SOFT FAIL ALARM DOWNLINK RSSI POWER (Green) VFD ALARM (Red) The VFD display will disappear 30 minutes after VFD button is pressed. If the VFD button is pressed, the display will come up again.
Epoch-M1C RF Repeater User Manual V1.1 Hard Fail Alarm Operation Hard Alarm Operation SYSTEM ALARM CHECKING Power Off Power On 20 min POWER (Green) VFD ALARM (Red) 4 sec 16 sec Booting Time SYSTEM HALT POWER (off) VFD ALARM (off) Initializing....