WIRING DIAGRAMS 24.11 AISLE SENSORS CONNECTION 128 The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l. These materials and information are intended solely for the purpose designated and may not be used otherwise. It is not permitted to disclose or reproduce them in whole or in part without express written permission.
WIRING DIAGRAMS 24.12 SPEED SENSOR CONNECTION The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l. These materials and information are intended solely for the purpose designated and may not be used otherwise. It is not permitted to disclose or reproduce them in whole or in part without express written permission.
WIRING DIAGRAMS 24.13 SHOCK SENSOR CONNECTION 130 The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l. These materials and information are intended solely for the purpose designated and may not be used otherwise. It is not permitted to disclose or reproduce them in whole or in part without express written permission.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25 DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.1 SENSOR Code PLX SAFEMOVE SENS 4 The Sensor is positioned around the vehicle, and generates 2 alarm/detection zones around the vehicle: Pre-Warning up to 50 m Warning up to 5 m The sensor also detects the presence of other vehicles in the Pre-Warning area up to 100 m. This function is enabled only after activating the SOFTWARE LICENCE and purchasing the Vehicle-vehicle Module.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.2 HUB Code PLX SAFEMOVE HUB 4 The HUB is the device in charge of managing the sensors. It has a communication connection towards the CPU and 3 connections towards the sensors. The number of sensors managed can be extended up to 8 with suitable expansion devices. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE 12-24 V MAXIMUM POWER (1-4 sensors) 20W MAXIMUM POWER (5-8 sensors) 40W OPERATING TEMPERATURE -20°C +60°C DEGREE OF PROTECTION IP65 WEIGHT 0.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.3 WEARABLE TAG Code PLX TAGSAFETY 3T Clip for band Slot for strap Snap fastener Use the screws supplied: 2.2 X7 Use the screws supplied: 2.2 X6 Use the screws supplied: 2.2 X7 With the wearable Tag, pedestrian workers can be detected by the EGOpro Safe MOVE 4.0 system either in Pre-Warning or in Warning. The Tag is powered by a lithium button cell battery that is easy to replace. The case is ergonomic and its upper cover is made of rubber.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.4 HELMET TAG Code PLX TAGSAFETY 3TH The helmet Tag has the same functions as the wearable Tag, but it has been designed to be affixed to safety helmets. It uses two-antenna architecture for Pre-Warning located inside flexible wings fitted with suitable adhesive for polyethylene and HD polyethylene, the material with which safety helmets are made. It is powered by a 2450 button cell battery that is easy to replace.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.5 CONTROL UNIT Code P LX SAFEMOVE CPU The CPU of the EGOpro Safe Move 4.0 system is the core of the system. All devices must be connected to a CPU via a Data Bus. It manages everything related to configurations, data logging and the activation of other functions compatible with the system (e.g., speed reduction).
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.6 DISPLAY Code P LX SAFEMOVE DIS By means of visual and sound alarms, the Display warns the driver, in real time, about the presence and position of pedestrian workers/vehicles with an active Tag entering the danger areas around a vehicle in motion. The display is connected to the control unit by means of a sole 2.5m-long cable that has a bayonet connector at its end. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE 12-24 V MAX.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.7 INHIBITOR Code P LX FILTER SENS The inhibitor (P LX FILTER SENS) is a device used to delimit a zone within which, in accordance with the client's safety needs defined, the Tags are temporarily disabled. This device is found in the cabin of the vehicle; in this way, the driver can wear the Tag while driving. When the TAG is outside the range of action of the device, it is reactivated after 3 seconds so that the driver is safe when outside the vehicle.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.8 SPLITTER Code P LX SPLITMOVE04 The splitter is an element of the system if more than three sensors are to be fitted on the vehicle. TECHNICAL SPECIFICATIONS 138 SUPPLY VOLTAGE 12-24 V MAXIMUM POWER 0.6W OPERATING TEMPERATURE -20°C +60°C DEGREE OF PROTECTION IP65 WEIGHT 0.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.9 INDOOR SPEED SENSOR Code P LX SEN AD The indoor speed sensor is a radar module to measure vehicle speed, even if there is no GPS signal. With the speed sensor, the speed signal is also received indoors since an external signal is not necessary for operation. Please, keep in mind that the speed sensor does not supply data about the vehicle position, only the speed. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE 12-24 V MAXIMUM POWER 0.
DATA SHEET OF THE COMPONENTS OF THE SYSTEM 25.10 SHOCKS SENSOR Code P LX SEN SK The indoor speed sensor is a radar module to measure vehicle speed, even if there is no GPS signal. With the speed sensor, the speed signal is also received indoors since an external signal is not necessary for operation. Please, keep in mind that the speed sensor does not supply data about the vehicle position, only the speed. TECHNICAL SPECIFICATIONS SUPPLY VOLTAGE 12-24 V MAXIMUM POWER 0.
The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l. These materials and information are intended solely for the purpose designated and may not be used otherwise. It is not permitted to disclose or reproduce them in whole or in part without express written permission.
Exclusively to the following activities: research, development, design, manufacturing, maintenance and after-sales service of electronic systems Advanced Microwave Engineering S.r.l. Via Lucca 50-54, 50142 Florence, Italy Tel.: +39 055 73921 E-mail: info@ameol.it Website: www.ameol.it 142 The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l.