Annex No.
Stand Alone READER ST100 Users Interface Description ADVANCED ID ASIA ENGINEERING CO.LTD. 116 M.3 T.Maekhue, A. Doisaket, Chiangmai, Thailand 50220 Tel: +66 53 387316-7 Fax: +66 53 387319 Website : WWW.AAE.CO.
Contents : 1. 2. 3. 4. 5. Pictures of UHF RFID Stand Alone Reader ST100........................................... 3 Pre-installation Precautions ............................................................................... 3 Abstract.............................................................................................................. 4 General description ........................................................................................... 4 Operation ......................................
1. Pictures of UHF RFID Stand Alone Reader ST100 Package Contents Front of Stand Alone Reader and components Antenna 1. Stand Alone Reader ST100 (please see left pictures) DB9 connector 2. Switching Power supply DC power connector 3. Support CD Status LED 2.
3. Abstract This document describes the user interface of the Stand Alone RFID reader ST100 for release 1.03 and further. 4. General description The Stand Alone reader ST100 is a robust, long read range, multi-protocol UHF RFID reader for outdoor and indoor use. It employs Advanced ID’s state of the art technology that combines high performance and reliability with ease of use.
5.2 Writing data to Tag Some kinds of tags have an internal memory that can be written with user data. Please check the tag characteristics with the manufacturer. Data can be written into the Tags with PC application (see Support software) in 2 formats as; • ASCII : normal text • EPC : the EPC data must according to EPC Tag Data Standards. (Automotive Industry Action Group’s (AIAG) B-11 RFID Item Identification Standard.) 5.
• 6.5 Read ID and Data – Reader will read Tag ID and also data in the same time. Communication mode You can set Communication mode with PC application (see Support software) in 2 modes as follow; • Send records only if required while reader is connecting to PC if reader read some Tag ID, reader will send records to PC only when you click on “Load Data” button. • Send record when data was stored while reader is connecting to PC, reader will send records every time if reader read some Tag ID. 6.
7.1 Dot Net Frame work 2 (manual installation) This step is required if your PC does not already have .Net Framework v1 (only) already installed. If it does, setup software will skip to next section. To install Dot Net Framework 2.0 - double click the Dot Net Framework 2.0.exe icon (as left picture) - follow the instructions in dialogue boxes until installation is finish. (as lower picture) 7.
7.2.2 Start RFID Note To start RFID Note - connect the Unit to PC with USB communication cable. (male side connect to unit and female side connect to pc) - switch “ON” the unit - double click on RFID Note icon (as a left picture) - then RFID Note starting window (see lower picture) and Connection tab window will appear. 7.2.3 Connection tab Ready connection Connection tab (checking Reader connection) This is the first and most important tab in RFID Note you will see.
7.2.4 Download tab Download tab Download button Grouping area This tab is use for management the data from the unit. For example; - download tag ID read by unit. (you can download all the data or select from the specific address ) - download data from SD card. - make a online(real time) communication between unit an pc. - edit tag data, etc. To download all data from the unit; - click on Download button. - then all data read by unit will be downloaded into your pc automatically.
7.2.5 Reader Setting tab This tab is allow you to change configuration and set up the unit with firmware 5.00 and further. Some commands will erase all data and failure to follow instructions correctly may cause severe damage to the unit’s memory and may permanently erase your data. 7.2.5.
7.2.6 Write EPC tag tab This tab is use for command unit to write data into EPC tag. Set data address and Data length need your confirmation because these operations will erase all data in the unit’s memory. (see left picture) 7.2.6.1 Set data length and start address First of all you need to set data length and start address to match EPC data format.
7.2.7 Write ISO tag tab This tab is use for command unit to write data into ISO tag. Set data address and Data length need your confirmation because these operations will erase all data in the unit’s memory. (see left picture) 7.2.7.1 Set data length and start address First of all you need to set data length and start address to match EPC data format.
7.2.8 Tag Note Tab 7.2.9 You can add more tag details which you read by unit in this tab and the tag data will be stored in database. You can access to this tab by double click on any row of Tag ID when you are in Download tab. Help tab This tab contains Users Interface Description documents, RFID Note software details others support software descriptions, and Firmware support details.
FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: “This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.