ADXV DAS User Manual Version 1.
Information in this document is subject to change without notice. Advanced RF Technologies, Inc. 1996-2015. All rights reserved. Please send comments to: E-Mail: Phone: Fax: info@adrftech.com (818) 840-8131 (800) 313-9345 (818) 840-8138 Address: Advanced RF Technologies, Inc. Attention: Technical Publications Department 3116 Vanowen St. Burbank, CA 91505 USA www.adrftech.com Advanced RF Technologies, Inc.
Revision History Version 0.1 0.9 1.0 1.1 1.3 1.31 1.4 1.5 Author YH Ko YH Ko CK CHO CK CHO CK CHO CK CHO CK Cho CK Cho Descriptions Date Initial Release VU, WCS, BRS, PS78 added VU External Filter, Frequency Range Change Update Add Warning Statement Add 600MHz Band Revision Update BTF Add 900MHz Band 03/07/2016 07/05/2017 07/25/2017 01/18/2018 01/26/2018 11/28/2019 07/03/2020 Change List Version Change list Advanced RF Technologies, Inc.
Table of Contents 1. Introduction ......................................................................................................................................................11 1.1 Highlights ...................................................................................................................................................11 1.2 ADXV DAS Quick View ................................................................................................................................
3.2.2.3 LED ............................................................................................................................................34 3.2.3 PSU (ADXV-R-PSU) ..............................................................................................................................34 3.3 3.2.3.1 Port ...........................................................................................................................................34 3.2.3.2 LED ...........................
7.2.4 Help ....................................................................................................................................................54 7.2.5 Logout .................................................................................................................................................55 7.3 Guest Mode ...............................................................................................................................................55 8.
Figures Figure 2-1 Figure 2-2 Figure 2-1 Figure 3-1 Figure 3-2 Figure 3-3 Figure 3-4 Figure 3-5 Figure 3-6 Figure 3-7 Figure 3-8 Figure 3-9 Figure 3-10 Figure 3-11 Figure 3-12 Figure 3-13 Figure 3-14 Figure 3-15 Figure 3-16 Figure 3-17 Figure 3-18 Figure 3-19 Figure 3-20 Figure 3-21 Figure 3-22 ADXV DAS HE Quick View (Front and Rear) ........................................................................................12 ADXV DAS RU Quick View (Front and Rear) ............................................
Figure 7-13 Figure 7-14 Figure 7-15 Figure 7-16 Figure 7-17 Figure 9-1 Figure 9-2 Figure 9-3 Figure 9-4 Change Password ................................................................................................................................53 User Log ..............................................................................................................................................54 System update ............................................................................................
Tables Table 2-1 Table 3-1 Table 3-2 Table 3-3 Table 3-4 Table 3-5 Table 7-1 Table 7-2 Table 7-3 Table 7-4 Table 7-5 ADXV-DAS Scalability ..........................................................................................................................19 NMS LED Specifications ......................................................................................................................22 NMS AAI Specifications .................................................................................
UL Uplink VSWR Uplink The path covered from the subscribers’ service area to the Base Transceiver Station (BTS) via the repeater Voltage Standing Wave Ratio Advanced RF Technologies, Inc.
1. INTRODUCTION Currently the ADXV supports 700 MHz (Lower A, Lower B, Lower C, and Upper C), SMR800/Cellular, PCS, AWS, WCS, BRS, PS700, PS800, 900P,VHF and UHF band. 1.1 Highlights Modular Structure (HE) - Supports multi bands service in one body Supports up to 12 slot available for POI, ODU, CHC card, etc.
1.
RU Quick View UL IN ADXV-R-ORU DL IN UL OUT DL IN UL OUT SERVICE SERVICE SERVICE SERVICE CPL(-30dB) CPL(-30dB) CPL(-30dB) CPL(-30dB) CPL(-30dB) SERVER SERVER SERVER SERVER SERVER ALARM SERVICE ADXV-R-3XX ADXV-R-3XX DC IN ADXV-R-3XX ADXV-R-3XX DC IN DC IN ADXV-R-PSU ALARM GUI ORU PSU ALARM RU5 DC IN RU4 DC IN ADXV-R-3XX FAN OFF – AC - ON Figure 2-2 UL OUT AC IN 110V RU1 RU2 RU3 BATTERY Ground Terminal Optical Remote Unit (ORU) DL IN SERVICE DC IN Remote Module
RF EXPOSURE & ANTENNA PLACEMENT Guidelines Actual separation distance is determined upon gain of antenna used. Please maintain a minimum safe distance of at least 30 cm while operating near the donor and the server antennas. WARRANTY Opening or tampering the ADXV DAS will void all warranties. Lithium Battery: CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO INSTRUCTIONS. Ethernet Instructions: This equipment is for indoor use only.
FCC Part 20 WARNING. THIS is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Laser Safety Fiber optic ports of the ADXV DAS emit invisible laser radiation at the 1310, 1550nm wavelength window.
Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only restrictions is prohibited. Any changes or modifications not expressly approved by the party responsible for compliance could avoid the user's authority to operate this equipment. Home/ personal use are prohibited Only 50 ohm rated antennas, cables and passive equipment shall be used with this remote.
RSS-102 RF Exposure L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 30 cm entre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur. Advanced RF Technologies, Inc.
2. BLOCK DIAGRAM 2.1 ADXV DAS Block Diagram HE TX Common RX 900P POI DL UL DL IN V/UHF(136~512) DL IN (698~2690) TX Common RX DL UL OUT V/UHF(136~512) UL UL OUT (698~2690) TX Common RX S8C POI UL TX Common RX 700L POI UL TX Common RX UL PCS POI 700U POI CHC ODU#1 DL DL CHC DL RU ORU RF 7F RM Duplexer RF S8C RM Duplexer RF PCS RM Duplexer RF 900P RM Duplexer PSU Figure 2-1 Advanced RF Technologies, Inc.
2.2 ADXV-DAS Scalability Table 2-1 Unit Scalability POI 700F, Cellular, AWS, PCS, SMR800, PS78, VU(VHF, UHF), BRS FDD, BRS TDD, WCS, 900P No limitation in 12 slots except NMS NMS 1 CHC No limitation in 12 slots except NMS Optic Unit No limitation in 12 slots except NMS In case of Aux, No limit in 8 Aux ports RU 64 Supported band HE RU PSU (RU) ADXV-DAS Scalability Adaptor type 19” rack mount (AC or DC) Advanced RF Technologies, Inc.
3. ADXV OVERVIEW 3.1 Head End The head end unit always has to be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. Specifications Size: 19.0 x 19.7 x 7inches (482 x 500 x 178 mm) Weight: 64.
3.1.1 NMS (Network Management System) Functions and features - Supports SNMP v1, v2, and v3 (get, set & trap) and web-based GUI Interface. Monitors alarms and status Provides control interfaces with all subordinate modules Provides overall DAS structure via the auto tree update function ADXV-H-NMS-DC is for DC type ADXV-H-NMS-AC is for AC type HE’s battery backup option is available only in ADXV-H-NMS-AC - Size: 19.0 x 12.1 x 1.7inches Weight: 3.
ADXV-H-NMS-AC LAN0 HOST REMOTE LAN0 LAN1 LINK SERVICE BATTERY OFF - AC - ON AC IN 110V Figure 3-3 ADXV-H-NMS-AC Front View 3.1.1.1 LEDs NMS has LEDs on the front panel as shown in Figure 3-4. POWER LINK Figure 3-4 Table 3-1 NMS LED NMS LED Specifications ADXV DAS-NMS POWER LINK Solid Green OFF Solid Red Solid Green Specifications NMS power is ON NMS power is OFF HE Link Fail alarm exists in the system No HE Link Fail alarms are present in the system 3.1.1.
01 02 03 04 05 N(-) P(+) Figure 3-5 NMS AAI NMS has 5 external alarms out interface pins on the front panel. Table 3-2 NMS AAI Specifications AAI Alarm Status Normal Alarm Output High Impedance (Open) Low Impedance (Short) 3.1.1.3 Ethernet Port The Ethernet port can be used to communicate directly with the ADXV DAS using a RJ-45 crossover cable or can also be used to connect the ADXV DAS to an external modem box. LAN0 LAN1 Figure 3-6 Ethernet Port 3.1.1.
LAN0 HOST REMOTE Figure 3-7 Host/Remote Switch Host IP: 192.168.63.1 (Fixed IP, unable to modify this IP address) Remote IP: 192.168.63.5 (Default IP, but can be modified in Host mode) 3.1.1.5 Power Connection For DC type(-48VDC) ADXV-H-NMS-DC has terminal block for DC power connection on the front panel. You should verify voltage and power polarity of each power line and should turn on the power after power connection necessarily. RTN -48V DC IN Advanced RF Technologies, Inc.
LAN0 HOST REMOTE LAN0 For AC type(AC 110V) LAN1 ADXV-H-NMS-AC has two push-lock connectors for battery backup and AC power connection on the front panel. You should verify voltage and should turn on the power after power connection necessarily SERVICE LINK BATTERY OFF - AC - ON AC IN 110V 3.1.1.
- Easily support additional frequency bands by adding a POI Reduces complexity and overall equipment size Specifications 3.1.2 Size: 1.3 x 17.0 x 6.85 (in) Weight: 6.
3.1.3 POIL-VU (ADXV-H-POIL-VU) ADXV-H-POIL-VU UL IN1 DL OUT1 UL IN2 DL OUT2 UL IN3 DL OUT3 SERVICE UL IN4 DL OUT4 UL UL IN5 DL OUT5 UL IN6 DL OUT6 UL DL UL IN7 DL OUT7 UL IN8 DL OUT8 DL ADXV-H-POIL-VU Figure 3-10 POIL-VU front View Functions and features - Supports VHF/UHF frequency band Provide RF interface with BTS Modular type and hot swappable Supports simplex TX and RX port Specifications - Size: 2.6 x 17.1 x 6.85 (in) Weight: 8.85 lbs 3.1.3.
POI Power Specifications Solid Green Solid Red Solid Yellow POI power is ON and POI/POIL is normal status POI power is ON and POI/POIL is hard fail alarm status POI power is ON and POI/POIL is soft fail alarm status 3.1.3.
- Size: 1.3 x 17.0 x 6.85 (in) Weight: 4.4lbs per CHC 3.1.4.1 RF ports 3.1.4.1.1 RF ports at the front panel (DL 1 to DL 8, UL 1 to UL 8) DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL OUT/UL IN Ports at the front panel of POI. Receive the downlink signal from each POI Split the uplink signal received from ODU to each POI 3.1.4.1.2 RF ports at the back panel (DL 1 to DL 8, UL 1 to UL 8) DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL IN/UL OUT Ports at the back panel of ODU.
The ADXV-H-ODU-4 has the following LEDs on the front panel as shown in Figure 3-14. PD1 PD2 PD3 PD4 LD PWR Figure 3-14 ADXV-H-ODU-4 LED Table 3-5 ODU LED Specifications ADXV DAS-Module PWR LD PD1 to PD4 Solid Green OFF OFF Solid Yellow Solid Green Solid Yellow Solid Green Specifications Module power is ON Module power is OFF ODU is not installed LD Fail alarm exists in the ODU No LD Fail alarm is present in the ODU PD Fail alarm exists No PD Fail alarm is present 3.1.5.
UL IN DL IN UL OUT DL IN UL OUT DL IN UL OUT SERVICE SERVICE SERVICE SERVICE CPL(-30dB) CPL(-30dB) CPL(-30dB) CPL(-30dB) CPL(-30dB) SERVER SERVER SERVER SERVER SERVER ALARM SERVICE LINK SERVICE E-DL SERVICE ADXV-R-3XX ADXV-R-3XX ADXV-R-3XX ADXV-R-3XX ADXV-R-3XX DC IN DC IN DC IN DC IN DC IN DC IN DC IN DC IN DC IN AC IN 110V ALARM GUI ORU PSU ALARM RU5 DC IN RU4 FAN AC IN 110V ALARM GUI ORU PSU ALARM RU5 DC IN RU4 DC IN ADXV-R-PSU FAN UL 6 UL OUT
3.2.1 Remote Module (RM, ADXV-R-3xx) DL IN UL OUT DC IN SERVICE CPL(-30dB) SERVER ADXV-R-3XX Figure 3-18 ADXV-R-3XX (RM) Front and Rear View Spec - Size: 2.3 x 13.8 x 6.85 (in) Weight: 9.92 lbs 3.2.1.1 RM ID numbering and RF line connection scheme RM ID right next to ORU is RM #1, RM 2nd next is RM #2 and the rest of RMs’ ID numbering is in the same order.
3.2.1.2 RF port DL IN/UL OUT connect to ORU’s DL port and UL port, it is necessary to connect UL’s port number equal to DL’s because of serial communication with ORU. CPL (-30dB): DL output 30dB coupling SERVER: DL output, UL input, Server Duplexer port 3.2.1.3 Power port DC IN: Port for power supply (+27VDC) and communication with Controller inside PSU. 3.2.1.
- VHF-DL/VHF-UL ports connect to the ADXV VHF/UHF RM - OPTIC port connects with optic line with waterproof optical connector (provided by ADRF) 3.2.2.2 Rear port - DC IN port connects to PSU’s ORU port. - PSU ALARM port connects to PSU’s ALARM port. - GUI port for connection to Lap- top. - FAN port for connection to FAN unit. 3.2.2.
- ALARM port connects to ‘PSU ALARM’ port of ORU - AC IN 110V port connects to AC 110V 3.2.3.2 LED LED ALARM LED color Green Yellow Green Yellow Red SERVICE Status Normal Link fail Normal Soft fail Hard fail 3.2.3.3 AC Switch The ADXV-RU is operated at 110 AC. (WARNING: The AC switch must be set to OFF before cable connection to avoid equipment damage and personal injury.) (WARNING: To avoid damage, be sure 110V AC for operation of ADXV-RU.) (CAUTION: DOUBLE POLE/NEUTRAL FUSING.
4. CABLE CONNECTION 4.
4.
5. MOUNTING METHOD 5.1 Head End 5.1.
5.2 RU 5.2.1 Rack Mount SD DL IN UL OUT DL IN UL OUT DL IN UL OUT DL IN UL OUT CPL(-30dB) CPL(-30dB) CPL(-30dB) CPL(-30dB) RU2 DC IN DC IN SERVER ADXV-R-3XX SERVER ADXV-R-3XX SERVER ADXV-R-3XX ADXV-R-PSU ORU ALARM AC IN 110V RU3 BATTERY SERVER ADXV-R-3XX OFF – AC - ON ADXV-R-3XX Figure 5-2 6.
6.2 ADXV DAS Installation Procedure 6.2.1 HE Installation Procedure CAUTION: ADXV DAS HE should be installed inside building only. 6.2.1.1 Installing a ADXV DAS HE in a rack The ADXV HE chassis mounts in a standard 19” (483mm) equipment rack. Allow clearance of 3” (76mm) at the front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required. Consideration: - Eight mounting holes are located on 4 corners of ADXV HE to attach it to the 19” rack.
Figure 6-1 Advanced RF Technologies, Inc.
6.2.2 RU Installation Procedure The ADXV RU chassis mounts in a standard 19” (483mm) equipment rack. Allow clearance of 3” (76mm) at the front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required. Consideration: - Eight mounting holes are located on 4 corners of ADXV RU to attach it to the 19” rack. The ADXV RU must be securely attached to a rack that can support the weight of the ADX.
Figure 6-2 Advanced RF Technologies, Inc.
The coaxial cables which are connected to antenna port of RU. Before connection, check the VSWR value of coaxial cable whether it is within specification using Sitemaster.. At this time, check if the Return loss have above 15dB or VSWR have below 1.5 The part of antenna connection fasten to port not to be loosed and not to be injected the dusty and insects The antenna connected to RU is only serviced in in-building 6.3 Grounding A ground cable is included in the box.
6.4 Optic Port Cleaning We recommend cleaning optic connector using a dry optical cleaning swab or tissue in a dry environment as needed. We recommend cleaning the optic connectors only if the expected optic loss is higher than the loss reported in the Web-GUI by 1.5dBo. (Figure 6-5) When optic connector are not in use, the port should be covered with a protective dust cap.
7. WEB-GUI 7.1 Web-GUI Setup The Web-GUI allows the user to communicate with the DAS system either locally or remotely. To connect to the DAS system locally, you will need a laptop with an Ethernet port and a RJ-45 crossover cable. To connect to the DAS system remotely, you will need to have an active internet connection and the ADXV system must have and external modem box connected to the ADX. 7.1.
7.2 Administrator/User Mode 7.2.1 Common 7.2.1.1 Navigation Tree The navigation tree located on the left hand side of the Web-GUI allows the user to switch between the various modules that are connected to the system.
Figure 7-2 ADXV DAS General Information Information: Displays the serial number, latitude/longitude, firmware version of selected module, and Web GUI version of the NMS. Location: Displays the address where the ADXV DAS is installed. Description: Displays the description of selected module. The description of each module can be edited from the Install tab. It is recommended to use the location of the module as the description.
7.2.2 Status Tab 7.2.2.1 Status – NMS The NMS Status page provides an overall view of how the system is performing. From the NMS Status page, the user can see what modules are connected to ADXV DAS. In addition, the user can see if any alarms are present in the system and also the commissioning status of each module. 7.2.2.1.
This section allows the user to input the latitude and the longitude of the repeater. Figure 7-4 Location Setting (Install – NMS) Select N or S from the dropdown menu for Latitude Select E or W from the dropdown menu for Longitude Input the first 3 numbers of the latitude/longitude in the text area after the “+” and before the “.” Input the last 6 numbers of the latitude/longitude in the text area after the “.” 7.2.2.1.
Figure 7-7 7.2.2.1.10 SNMP Agent False Alarm Test (Install – NMS) Location Info / Installer Info This section allows the user to specify the address of the repeater and also the information of the installer. Figure 7-8 Advanced RF Technologies, Inc.
7.2.2.1.11 Date & Time This section allows the user to specify the current date and time. Figure 7-9 7.2.2.1.12 Date & Time Setting (Install – NMS) Description This section allows the user to save the description of remote module. Figure 7-10 Description (Install-Remote Module) 7.2.
Figure 7-12 New Account 7.2.3.1.3 System: Account - Change Password The Change Password section allows the current user who is logged into the system to change their login credentials. Figure 7-13 Change Password 7.2.3.2 System: Logs 7.2.3.2.1 System: Logs - Event Log This section displays system events that have taken place. The Event Log displays who has made the changes, the time and date of when the event took place, and what changes were made to the system.
Figure 7-14 User Log 7.2.3.3 System: Update To perform a firmware update, click on the System:Update tab and the following screen will show up. Figure 7-15 System update Click on the ‘Browse’ button and locate the firmware file. Click on the Update button to perform the firmware update. Once the firmware update is complete, the following message will appear. Figure 7-16 Message after System update is complete 7.2.
Figure 7-17 Help 7.2.5 Logout Clicking the Logout button will log the current user off the system. 7.3 Guest Mode When logging into the system as a guest, the guest will only have read-only privileges and will not be able to make any changes to the system. Advanced RF Technologies, Inc.
8. SYSTEM-WIDE SPECIFICATION 1.1 700MHz/S8C/Ps78/PCS/.AWS/BRS/VU Specifications.
≤ 1.5:1 @ Internal interface port Optical Loss 0~5dBo System Delay < 2us Meet FCC rules, 3GPP TS 36.104, 3GPP2 C.S0010-C Spurious Head End 19 x 19.7 x 7.0 Chassis 1.3 x 17.0 x 6.85 POI/POIL Dimension (WXDXH, in) RU(Remote 2.6 x 17.0 x 6.85 19 x 15.0 x 7.0 Unit) Chassis RU Chassis 9.85 x 15.0 x 6.6 for PS78 and VU RU(Remote Unit) N4X RM(Remote 2.3 x 13.8 x 6.85 Module) Head End 20.9(including NMS-AC) Chassis 6.17/5.0 POI/POIL RU(Remote Weight(lbs) 8.85 15.
ADXV-R-PSU-AC: 100 to 240V, 50-60Hz with battery backup function RU ADXV-R-PSU-DC: -36V to -72V DC Network Management Ethernet(RJ45) System RF connector POI DIN (Female) | SMA (Female) | SMB (Female) POIL 4.3-10 (Female) | SMB (Female) Remote 4.3-10 (Female) | SMA (Female) Modules Weather Resistance IP66 (Remote Modules) "The Manufacturer's rated output power of this equipment is for single carrier operation.
Dimension POIL 1.31 x 6.86 x 17.02 inches (WXDXH) RM(Remote Module) 2.29 x 6.86 x 13.79 inches POIL 5.0 lbs Weight RM(Remote Module) 9.
9. MECHANICAL DRAWING 9.1 HE Figure 9-1 Advanced RF Technologies, Inc.
9.2 RU Figure 9-2 Advanced RF Technologies, Inc.
9.3 N4X RU for PS78 Figure 9-3 Advanced RF Technologies, Inc.
9.4 N4X RU for VU Figure 9-4 Advanced RF Technologies, Inc.