Installation Instructions

FlexGuard® 5853 Wireless Glassbreak Detector – Installation Instructions
5853 Glassbreak Detector Internal Parts
CR-123A
Mounting Hole
Mounting Hole
Battery
Front Tamper Switch
LED Indicators
Microphone
Sensitivity Switches
Wall Tamper (behind battery)
Test Mode pads (on PCB)
Front Cover
Latch
Break out flash
for cover screw
2
1
ON
OFF
5853-1_001-V0
Connect Battery
Remove pull tab to connect battery.
NOTE: Constant exposure to high or low temperature or high
humidity may reduce battery life.
BATTERY
5853-1_002-V2
Select Mounting Location
For the best detector performance, select a mounting
location that is:
within 7.6 m (25 feet) of the protected glass;
within clear view of the protected glass;
at least 2 m (6.5 feet) from the floor;
at least 1 m (3.3 feet) from forced air ducts;
at least 1 m (3.3 feet) from sirens or bells greater
than 5 cm (2 inches) in diameter.
between the protected glass and any heavy
window coverings that may be present.
Alternatively, when heavy window coverings are
present, the detector can be mounted on the frame of
the window.
Avoid mounting the detector on the same wall as the
protected glass, on free-standing posts or pillars, or in
rooms with noisy equipment (air compressors, bells,
power tools, etc.), if this equipment is operated when
the detector is armed.
Wall Mount
(Top View)
WallMnt-001-V0
CeilingMnt-001-V0
Ceiling Mount: (Side View)
NOTE: If the device is ceiling mounted, the end with the
hole (Microphone end) should face the protected glass.
Set Sensitivity (Range)
SENS2
SENS1
5853-1_004-V2
ON
OFF
SENS1 & SENS2 configure sensitivity
SENSITIVITY
RANGE
SENS1
SENS2
MAX 7.6m (25 ft)
OFF
OFF
MEDIUM 4.6m (15 ft)
ON
OFF
LOW 3m (10 ft)
OFF
ON
LOWEST 1.5m (5 ft)
ON
ON
NOTE: Ranges are approximate and vary with each
room’s acoustic properties. Always verify range with a
FlexGuard FG-701 Glassbreak Simulator.
Enroll Detector
Refer to text and control panel's installation
instructions.
When programming the transmitter, specify:
Input Type = 3 (Supervised RF)
Loop Number = 1
Mount Detector
Use mounting holes as a template to mark
mounting locations on ceiling or wall.
If using the optional back tamper, remove the
battery, then mark the wall tamper location
through its mounting hole.
Mount detector using appropriate hardware.
NOTE: A screw capture feature designed to
make ceiling mounting easier will cause some
resistance when inserting the screw into the
plastic.
Close detector cover when finished.
CR-123A
SENS2
SENS1
5853-1_003-V2
(Screw not supplied.)
3.5 mm x 38 mm
(#6 x 1-1/2")
3.5 mm x 38 mm
(#6 x 1-1/2")
#6 (3.5 mm) screw for
Optional Rear Tamper
*3.5 mm (#6)
screws works best
with the screw
retention feature.
To work properly, the back tamper
screw must be screwed into a
framing stud or a heavy-duty
hollow-wall anchor, such as a
#8 self-tapping anchor. This type
of back tamper is not suitable for
use on acoustic ceiling tile.
*The screw retention feature simplifies installation: A
rib in the screw cavity lightly holds the screw in place
when installing the detector.
Test Detector Installation
Enter Test Mode using a FlexGuard FG-701
Glassbreak Simulator (see Testing the Detector on the
next page). To enter Test Mode manually, short the
Test Mode pads (as shown below).
SENS2
SENS1
5853-1_005-V2
TEST
TEST
Install Cover Screw (optional)
5853_006-V1
2.9 mm (#4) screw, 
6 mm (1/4-in.) long