11 SPECIFICATIONS
Refer to Table 2-6 for the Digivance SMR 20 Watt System nominal specifications. All
specifications apply after a five minute warm-up period.
Table 2-6. SMR 20 Watt System Nominal Specifications
PARAMETER SPECIFICATION REMARKS
Optical - Host and Remote Unit
Fiber type 9/125, single-mode
Number of fibers required
Direct
With WDM
2
1
The wavelength division multi-
plexer (WDM) is an accessory.
Forward path wavelength 1550 nm
Reverse path wavelength 1310 nm
Optical transmit power output
Host Unit
Remote Unit
0 dBm
–3 dBm
Optical budget 17 dB
For optical BER of 10
–6