FCC ID: F8I-DLC0802A User Manual - Part 4 ADCP-75-150 • Preliminary Issue A • March 2003 • Section 3: Host Unit Installation HOST UNIT 1 HOST UNIT 2 NET IN NET OUT NET IN NET OUT HOST UNIT 3 NET IN NET OUT 16900-B CONTROLLER AREA NETWORK INTERFACE CABLES TO NEXT HOST UNIT (NOTE: LAST HOST HAS NO CONNECTION AT NET OUT) Figure 3-12.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 3: Host Unit Installation 10 EXTERNAL ALARM SYSTEM CONNECTIONS The alarm interface between the HU and an external alarm system is supported by a six-terminal plug (with screw-type terminals) that connects to a receptacle mounted on the HU front panel. The terminal plug provides connections to normally open (NO) and normally closed (NC) dry type alarm contacts for both major and minor alarms.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 3: Host Unit Installation 6. Connect the Major and Minor alarm wire pairs to the appropriate terminals on the external alarm system. 7. Dress and secure cable per standard industry practice. 11 DC POWER CONNECTIONS The HU is powered by ± 24 or ± 48 Vdc power. The power is fed to the HU through a screwdown type terminal strip located on the rear side of the unit.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 3: Host Unit Installation 6. Connect the power wires to the appropriate terminals as specified in the fuse panel user manual. 7. Dress and secure the power wiring at the fuse panel and the HU. The procedure for checking the voltage level and verifying that the HU is ready to power up is provided in SECTION 4: OPERATION. Page 3-17 © 2003, ADC Telecommunications, Inc.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 3: Host Unit Installation Blank Page 3-18 © 2003, ADC Telecommunications, Inc.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation SECTION 4: OPERATION Content 1 2 Page BEFORE STARTING OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 1.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 1.2 Readiness Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation 1.2 Readiness Check Before starting the turn-up process, inspect the complete Digivance system to verify that all components of the system are ready to be powered-up. This will ensure that no units of the system will be damaged during turn-up and that all existing systems will continue to function properly. 1.2.1 Host Unit Installation Checks Complete the following checks at the HU prior to starting the turn-up process: 1.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation 2.1 Turn-Up Procedure Use the following procedure to turn-up the system: 1. Temporarily disconnect the external alarm system or notify the alarm system provider that testing is in progress. 2. If turning-up multiple HU and RU systems that have not been configured for operation before, temporarily disconnect the CAN cables from the NET IN and NET OUT ports of each HU.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation Click to view drop down menu Figure 4-1. Digivance Element Management System Main Window 9. Open the View drop down menu and connect to the Host and Remote pair by selecting “NotNamed/NotNamed”. The HOST Alarms display and the REMOTE Alarms display will open within the main window as shown in Figure 4-2. 10.
ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation 11. Click on the HOST Config tab and on the REMOTE Config tab (see Figure 4-2). The HOST Config display and the REMOTE Config display will open within the main window. 12. Enter the Site Name and Site Number for both the HOST and the REMOTE unit. Refer to Section 2.4 for details. 13. If the site has multiple host units, reconnect the CAN cables to the HU’s NET IN and NET OUT ports. 14.