User guide Edge-30R+ Edge-30R-N+ With firmware version from 3.2.3 Review 13 Copyright © 2022 Acura Technologies http://www.acura.com.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid 1 Products covered by this manual Rev. 13 5 1.1 Approval note 5 1.2 Legal Notice 6 1.3 About Acura 6 2 Introduction 7 2.1 About this guide 7 2.2 Conventions used in this manual 7 2.3 Target audience 7 3 Introduction to equipment 8 4 Table of revisions 9 4.1 User guide table 9 4.2 Readers firmware table 10 4.3 Readers hardware table 13 5 Installation notes and important warnings 13 Part 1 - Overview and installation 14 6.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.2 Electrical connections - Reader 31 8.3 Electrical connections - PCI 33 8.4 Electrical connections - Ethernet LAN 34 8.6 Electrical connections - Digital input (Sensor) 36 8.7 Electrical connections - Relé 37 8.8 Reader visual indicators 38 8.8.1 STATUS visual indicator 38 8.9 POE Injector Visual Indicators 39 Parte 2 - Operation and operation 40 9 Modes of operation of the reader 41 9.1 Continuous reading mode 41 9.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11.1 TCP/IP connections to receive tag readings 76 11.2 TCP/IP connection, disconnection, and reconnection logic 77 11.3 Format of reading results via TCP/IP and RS232 78 11.4 Syslog 79 12 Mensagens de Log do leitor - Syslog 81 13 Regional Regulations 82 13.1 Frequencies and operating region 82 13.2 RF reader power 82 14 Integrated antenna measurements 83 14.1 VSWR 83 14.2 Axial Ratio (±20° Azimuth) 902MHz 84 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 1 Products covered by this manual This user guide belongs to the following product: Reader Code UHF READER ACURA EDGE-30R+ Autoid 100.644 PCI INTERFACE EDGE-30R + 100.647 ANTENNA SUPPORT MTI BR 66MM 100.320 POE POWER SUPPLY 15.4W 501.248 1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Authorized Antenna General Characteristics of the Antenna of Edge-30 R+. Vendor MTI Wireless Model MT-262024 Frequency Range (MHz) 902-928 MHz Circular Gain (dBiC) 7,5 dBiC Linear Gain (dBi) 6.0 dBi Polarization Circular (RHCP) Type Patch 1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 2 Introduction 2.1 About this guide This user guide provides detailed information about the readers and is divided into two large parts, Part 1 with information for the physical installation (mechanical) of the reader and Part 2 with information on the operation and operation of the reader, including programming and configuration. 2.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 3 Introduction to equipment Edge-30R+ and Edge-30R-N+ readers are equipment with small and high-performance Radio Frequency Identification (UHF) RFID technology and high tag reading performance, with features and functionality useful for vehicular access control solutions that are described throughout this document.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 4 Table of revisions 4.1 User guide table Revision Month/ye ar date 13 02/2021 Description • • Update the information according to the Edge-30R+ Autoid and Edge-30R-N+ Autoid reader; PcI change and information. 12 07/2021 • • Updates regarding the latest firmware; Update the preview procedure by Syslog. 11 01/2018 • Added information about the Edge-40R-N Autoid reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid 1 03/2015 • Rev. 13 Creation of this document. 4.2 Readers firmware table Revision Month/ye ar date 3.4.7 04/2021 3.4.6 09/2020 Description ● Fixed ERROR in the safe mode tag verification algorithm when two readers with different security codes stood side by side, close to each other, improper readings occurred. ● Fixed excessive memory consumption error when the reader was in Client mode.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid ● • • • 3.2.3 04/2017 • • • ● • • • • • 3.1.9 02/2017 • • • • ● ● 3.1.5 09/2016 ● ● ● Copyright © 2022 Acura Technologies Rev. 13 reader; Fixed memory consumption ERROR in the RS232 serial sending function.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid ● ● ● ● ● 3.0.1 02/2016 ● ● ● ● ● ● ● ● 2.0.4 09/2015 ● ● ● ● ● ● ● ● 2.0.3 06/2015 ● ● ● 2.0.2 03/2015 ● Copyright © 2022 Acura Technologies Rev.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 4.3 Readers hardware table Revision Month/ye ar date V1 03/2015 Description ● Creation and launch of the Edge-30R reader. 5 Installation notes and important warnings NOTICE: The maximum1 reading distance of passive tags per reader is up to 6m for the Edge-30R+, 4m for the Edge-30R-N+.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6 Equipment overview RFID Antenna 215 mm 6.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6.2 General reader characteristics Transponder Protocols Protocole ISO 18000-6C (Gen2) Interface RF RF output power Edge-30R+: from 0 to 30dBm with 0.5dBm increment Edge-30R-N+: from 0 to 27dBm with an increment of 0.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Data / Control Interface (continued) GPIO 1x Opto-isolated Digital Input: 1KV RMS insulation Supports Dry Contact, NPN (Sinking) and PNP circuit (Sourcing). Minimum pulse width: 100ms High Level (3.0 to 24.0VCC), Low Level (0 to 2.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6.3 Hardware - PCI interface The PCI Interface should be used in conjunction with the Edge-30R+ Autoid and Edge-30R-N+ Autoid readers with the function of facilitating the installation of the readers. It has RJ45 type connector and terminals for a quick and easy connection between the readers and the client controller.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 6.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7 Mechanical installation 7.1 Reader attachment support Readers together with the fixing bracket can be fixed on poles with a diameter variation from 1" to 1.75" or 1.75" to 3", can also be fixed on flat surfaces such as walls. 7.1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.1.2 Fixing the pole base 1" to 1.75" or 1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.1.4 Fixing the bracket arm at the base of the pole/wall NOTE: Readers can be mounted with the cable facing the top side or on the sides, as it is easier for installation, as the integrated antenna has circular polarization, the position in which the reader is installed relative to the output of its cable will not influence the performance of reading tags.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.2 Positioning of readers NOTE: The measurements and illustrations described in this section are recommendations for the best performance of reading the passive tag in the vehicle. It is important to follow the reader's maximum installation height recommendations so that the effective distance between the reader and the installed tag does not exceed the optimal reading distance of the passive tag.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.2.2 Track center Reader Max = 3m Physical barrier Gate sensor r Vehicle sensor The angle of the reader depends on the height of installation, the face of the antenna of the reader should be pointed to where the tag in the vehicle will be at the ideal reading distance of 3m between the reader and tag. You can measure 3m from the center of the antenna (installed) to an average height of 1.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.3 Reading problems When there are adjacent lanes near each other, tag readings may occur on unwanted tracks or locations near the reader's installation point. Below are some examples of multi-lane installations. To minimize the occurrence of unwanted reads as much as possible, some actions can be performed: 1. Filter of unwanted side/adjacent readings.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.4 Food and Communication To facilitate the installation of the reader, the power is made from a POE Injector via RJ45 cable, not requiring the PCI to be energized. If wiegand/abatrack communication is used, or the use of the input and logical output, it is necessary to use the PCI, which in turn, this communication is made by an RJ45 cable connected directly to the Interface Card of the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 7.5 Mechanical installation of pci interface The interface plate must be fixed on a DIN TS35 rail (35 x 7.5mm). 36 mm 7.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8 Eletrical Intallation 8.1 General diagram of electrical connections Controller (Not supplied) Sensor (Not supplied) 24VDC Source (Not Supplied) Digital Outputs(NC/CM/NO) PCI Interface Reader Switch/Router (Not supplied) Sinal POE Client PC (Not supplied) LAN PoE Source (Optional) No scale ATTENTIO N: NOTE: The antenna port of the readers are susceptible to damage from electrostatic discharges (ESD).
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.2 Electrical connections - Reader The figure below describes the reader's connection to the POE Injector. Reader PoE POE Input PoE Injector (Optional) No scale The table below describes the pins and colors of the RJ45 cable that will be used to connect the POE injector with the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid NOTE: Rev. 13 A standard T568A or T568B network cable can be used to connect the Injector to the Reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.3 Electrical connections - PCI The figure below describes the reader's connection to the PCI. PCI Interface Signal No scale The table below describes the pins and colors of the RJ45 cable that will be used to connect the PCI Interface with the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.4 Electrical connections - Ethernet LAN The figure below describes the connection of the reader's POE injector to the local Ethernet network of the client. Switch/Router PC Ethernet IN PoE Injector (Optional) No scale The table below describes the pins and colors of the network cable that will be used to connect the POE/Reader injector to the local Ethernet network.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid 8 NOTA: Rev. 13 Brown (MR/MR CL) A standard T568A or T568B network cable can be used to connect the Injector to the. The figure below describes the electrical connections of the Wiegand/Abatrack communication interface, which can be done with a customer's computer or with the client's controller board.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid NOTICE: Rev. 13 To avoid noise and external interference that may hinder communication between the reader and the controller/PC, avoid passing the Wiegand communication cable/flap near sources, lamp reactors, electrical power cables, or other electromagnetic noise sources. 8.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid NOTICE: Rev. 13 For digital input, use the "ISO_GND" pin for sensors with Dry Contact output and use the "ISO_COM" pin for sensors with wet contact output in any polarity. 8.7 Electrical connections - Relé Built into the PCI, the reader itself can send a digital signal through the handover. To use the digital outputs, the relay is required to power with an external 24 VDC source (not supplied, but may be the same as that used in the Edge-30R Autoid).
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.8 Reader visual indicators The reader has an operating status LED on the antenna. 8.8.1 STATUS visual indicator Blinks once fast (flashs) loop Indicates that the reader is in Continuous Read Mode. Lit during flash Indicates that a Tag Read occurred while the reader was in read mode. During tag reading the reader sends the tag data through the communication interfaces.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 8.9 POE Injector Visual Indicators The injector has two status LEDs for operation.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 9 Modes of operation of the reader 9.1 Continuous reading mode In this read mode, the reader performs read operations continuously, in other words, the reader is placed in a loop where it first performs the inventory operation and then sends the obtained results. This way, whenever a tag enters the reader's reading field, it will be read and its data sent through the communication ports.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 9.2 Trigger read mode In this reading mode, the reader performs read operations only when it receives a signal from a connected sensor in its digital input, which can be accessed by the "SENSOR INPUT" connector of the PCI Interface. Thus, in this cycle of operation there is, in addition to the inventory and send operation, a state in which the reader waits for a shot on its digital input.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10 Configuring the Readear 10.1 Reader IP address Readers (firmware 2.1.6 or above) with factory settings automatically generates their IP address using the default Range of Local Link Address IPV4 169.254.0.0/16. Readers use the following logic for generating their IP when they have factory settings: IP = 169,254. xx. xx where xx are the last two decimal digits of the reader's MAC address, for example, MAC = 0.36.119.82. Five, five of them.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid NOTE: Rev. 13 After the user has set up a static IP, the reader no longer generates the IPV4LL, only if a Hard reset is performed. 10.2 Configuring the reader via web browser The reader settings are made by accessing the reader through LAN or WAN networks, placing its IP address in an internet browser (Web Browser). In reader access, a login page is shown before the settings page. The factory settings (default) of the reader are • IP address: 169.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 NOTE: Only one user is able to connect to the reader configuration page. Login to the setup page expires after 3 (three) minutes. Thus, if another user wants to connect, they must wait for the first user to log out or pass the expiration time without any update on the page. NOTE: Network segment 169.254.0.0/16 must be configured on the network interface computer.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid RFID Hardware Hardware version of the RF module of the reader. AutoID Version Firmware version of the reader's internal controller. Rev. 13 Status parameters (Continued): Parameter Description MAC Address Physical address of the Ethernet interface, consisting of 6 bytes, is shown in decimal and hexadecimal format. Ethernet Mode Indicates whether the reader is configured as Client or Server.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.2.2 Security Settings 1. After login, click the Security option. 2. 3. 4. Change the settings. Click Apply to make the changes. If the Restart message is shown, click Restart. Security page parameters: Parameter Description Login Password Alphanumeric characters of a maximum of six digits that can be written to the reader to form the password that will give access to the settings page.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Security page parameters (Continued): Parameter Description Autoid system type Type of reading algorithm that the reader will run. Normal: The reader does not check any kind of security in reading the tags, it reads any standard ISO-18000-6C tag (UHF Gen2) in its reading field and reports on its communication interfaces.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.2.3 Setting up the network 1. 2. 3. 4. After logging in to the html page, click Network. Change settings as needed by the network. Click Apply to make the changes. If the Restart message appears, click Restart.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Parameter Description Ethernet Mode Defines the behavior of the reader on the network, and can act as server or client. Factory configuration: Server IP address Fixed IP address of the reader, this version of the reader does not support DHCP. Factory configuration: 169.254.xx.xx (Local Address Link, last two of the MAC) Network mask IP address of the subnet mask, devices on the same subnet can communicate locally without routing.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.2.4 Setting Up Reading 1. After login, click Read. 1. Change the parameters. 2. Click Apply to save the changes. 3. If you see the message prompting you to restart the reader, click Restart. Reading Parameters: Parâmetro Descrição Reading Mode Read operation mode that will be performed by the reader. Continuous mode: Operation mode where the reader performs read operations continuously.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Read parameters (continued): Parameter Description Reading power Power in centidBm (dBm / 100) referring to tag reading. The read power can be adjusted to change the read region of tags at the installation location. Factory configuration: 3000dBm | Values: 500 to 3000 centidBm (5 to 30 dBm).
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.2.4 Configurando a Comunicação 1. After login, click Communication. 1. 2. 3. Change the parameters. Click Apply to save the changes. If you see the message prompting you to restart the reader, click Restart.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Communication Parameters: Parameter Description Type communication interface Reading results are made available through the Wiegand or Abatrack communication interfaces, and simultaneously through tcp/IP Ethernet interfaces. You can use the two signal lines (W0/CLK) and (W1/DATA) as digital outputs, selected None(GPO), thereby disabling Wiegand and Abatrack communications.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Communication parameters (Continued): Parameter Description Keyword Data string (Continued) Description Size [characters] TEMP Temperature in °C of internal RF module. 02 TYPE Tag type read, 'S' for Safe and 'N' for Normal 01 ALIVE Reader uptime in seconds Caractere control ASCII Carriage Return [0x0D]. 01 ASCII Line feed control character [0x0A]. 01 Caractere de controle ASCII Start of text [0x02].
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Note: Other characters or words that do not match the words keys will be mirrored in the keepalive string that the reader transmits at each keepalive time interval. Factory configuration: Communication parameters (Continuation): Parameter Description Keepalive time interval Is the time interval in seconds for sending the Keepalive String. Factory configuration: 1s | Values: 1 to 60s.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 IO parameters: Parameter Description Lógica invertida do Reverses the trigger signal trigger ing logic (the NF contact of the lens can be sinal de entrada used for example). trigger Factory configuration: not selected (normal logic). IO (Relé) parameters: Parameter Description Pulse Duration When the reader is initialized, in which logical state the digital outputs should be configured.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Parameter Description Adjust date and time manually If an SNTP server cannot be used for clock timing there is the possibility of manual adjustment of the watch. Note: When loading the page, the date and time fields are updated with the data from the reader's internal clock. Daylight saving time If selected, it will adjust the reader's internal clock to daylight saving time. Factory configuration: Not selected.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Messages and replies must contain the prefix "$" (dollar sign followed by space) and the carriage return terminator The "SET" and "GET" functions should be just after the prefix and before the command separated by a space character. In the "SET" function, the command should be followed without space of the character "=" (equal) followed by the value of the parameter you want to change.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.3.4 Example of use Terminal emulator software, such as Putty or TeraTerm, should be used when a user wants to check or change reader parameters via ASCII messages. 10.3.5 Checking the status of the reader Command Function Description Version of rf module built into reader, is RFID firmware. RFVER GET Example: Direction Description $ GET RFVER $ 01.07.03.25 Host → Reader Host sends message.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Checks the connection status of the data communication port. STATCONN1 STATCONN2 GET Example: Direction Description $ GET STATCONN1 Host → Reader Host sends the message. $ DISCONNECTED Host ← Reader Disconnected port. $ GET STATCONN2 Host → Reader Host envied a message. $ CONNECTED 192.168.0.84:63344 Host ← Reader Connected to IP:PORT.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Verifica o status da conexão da porta de comunicação de dados. TMALIVE TMALIVEFMT GET Example: Direction Description $ GET TMALIVE $ 80577 Host → Reader Host sends the message. Host ← Reader 80577 seconds without rebooting. $ GET TMALIVEFMT $ 0d 22:23:00 Host → Reader Host sends message. Host ← Reader Time in days min hours. Mon. 10.3.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Exemplo: Direction Description $ GET AUTOID Host → Reader Host sends message to check which Autoid System is running. $ NORMAL Host ← Reader Reader replies that it is Autoid Normal. $ SET AUTOID=SECURE Host → Reader Host sends message to change the Autoid System to Safe mode. $ OK Host ← Reader Reader responds with OK. 10.3.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Example: Direction Description $ GET DNS1ADDR Host → Leitor $ Host ← Reader Reader responds with the value of the address; in this case it is empty. $ SET DNS1ADDR=192.168.0.15 Host → Reader Host envia a mensagem para alterar o endereço IP do servidor DNS. $ OK Host ← Reader Reader responds OK. Host sends the message to verify the address of the DNS server.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 $ SET SYSLGADDR=192..168.0.84 Host → Reader Host sends the message to change the IP address of the Syslog server. $ ERROR Host ← Reader Reader responds with error because the address format was incorrect. $ SET SYSLGADDR=192.168.0.84 Host → Reader Host sends the message to change the IP address of the Syslog server. $ OK Host ← Reader Leitor responde com OK.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Checks the physical address of the reader's Ethernet interface in two formats, decimal "MACDEC" and hexadecimal "MACHEX". MACDEC MECHEX Example: Direction Description $ GET MACDEC Host → Reader Host sends the message to read the MAC in decimal. $ 0.36.119.81.147.94 Host ← Reader Reader responds with the decimal value. $ GET MACHEX Host → Reader Host sends message to read MAC in hexadecimal.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Changes or checks the time, in seconds, of the read trigger. Values from 1 to 600s are allowed. Note: You do not need to reboot the reader. Note: Parameter used only when read mode is Trigger. RDTMTRG Example: Direction Description $ SET RDTMTRG=10 Host → Reader Host sends the message to change the value to read 10s after the trigger signal. $ OK Host ← Reader The reader returns OK.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Changes or checks the filter value by signal level (RSSI). Values from 20 to 99 dbm are allowed, leaving the value empty disables the filter. Note: You do not need to reboot the reader. FTRSSI SET/GET Example: Direction Description $ GET FTRSSI Host → Reader Host sends the message to read the rssi filter value. $ 50 Host ← Reader Reader replies that the value is -50dBm.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 $ SET SNDOPT=DRIVER Host → Reader Host sends the message to change the parameter. $ OK Host ← Reader Reader responds with OK. Changes or verifies the id that will be sent when an associated vehicular tag is identified by the reader, and the driver tag associated with the car tag has not been identified. The Id value must be a maximum of 8 characters and in hexadecimal format. Note: You do not need to reboot the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Setting Reading (continued): Changes or checks the value of the mask that the Id must contain to be read. Values allowed hexadecimal characters of a maximum of 24 digits. Note: You do not need to reboot the reader. Note: Parameter used only when autoid system type is Normal. SELFTMSK SET/GET Example: Direction Description $ GET SELFTMSK Host → Reader Host sends the message to read the mask value.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.3.9 Configurando Comunicação Changes or verifies which communication interface the reader should use. Values [WIEGAND, WG, ABATRACK, ABA, GPO]. . Note: None (GPO) to use w1/DATA and W0/CLK signals as digital outputs triggered via ASCII messages. INTFPRTCL Example: Direction Description $ GET INTFPRTCL Host → Reader Host sends the message to check which interface it is using. $ WIEGAND Host ← Leitor Reader responds.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Configuring Communication (continued): Change or check the Keepalive String, maximum 15 characters, for more details see section 10.1. Note: You do not need to reboot the reader. STRKP SET/GET Example: Example: Direction $ SET STRKP=RN Host → Reader Host sends the message to change the keepalive string. Host ← Reader Reader responds with OK.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 10.3.10 Configuring GPIO Changes or checks the time in milliseconds when the reader's digital input signal must remain enabled for the read operation to fire in trigger mode. Values from 0 to 1000ms. Note: You do not need to reboot the reader. TMFTDB SET/GET Example: Direction Description $ SET TMFTDB=500 Host → Reader Host sends the message to change the debouncing time to 500ms.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 $ SET OUTPUT0=~ Host → Reader Host sends the message to reverse the logical state of the l.A. $ OK Host ← Reader Reader responds with OK. $ SET OUTPUT0=* Host → Reader Host sends the message to trigger the laser's pulse. $ OK Host ← Reader Reader responds with OK. Configuring GPIO (continued): Individually changes or checks the initial logical state of OUTPUT0 to (W0/CLK) and OUTPUT1 to (W1/DATA). Values [0 or 1].
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Changes or checks the use of daylight-saving time on the reader's internal clock. Values [ON, OFF]. Note: You do not need to reboot the reader. DLSV SET/GET Example: Direction Description $ SET DLSV Host → Reader Host sends the message to disable daylight saving time on the reader's internal clock. Host ← Reader Reader responds with OK. $ OK Changes or checksthe use of checksum in messages. Values [ON, OFF].
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11 Data communication 11.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11.2 TCP/IP connection, disconnection, and reconnection logic Readers have the behavior of a Server, that is, it accepts TCP/IP connections on the user-configured port. Below are some important points regarding the reader server behavior: • The reader accepts up to six (6) simultaneous connections on the configured port; • For reconnection in case of passive disconnection, the Keepalive time interval must be respected.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 11.3 Format of reading results via TCP/IP and RS232 The format in which data is sent via Ethernet can be configured using the Data String parameter that uses key words to combine the results of reading tags with other desirable characters in the final string that the reader must send. With this type of configuration, it is possible to create a compatibility between the reader and Software Systems already developed.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 Regras de formato da String de dados: 1. Somente pode haver duplicidade dos caracteres de controle , as demais palavras chaves não podem ser duplicadas; 2. A String de dados deve conter ao menos uma das palavras chaves IDHEX, IDWG ou IDABA; 3. As palavras chaves são diferenciadas de maiúsculo e minúsculo; 4. O tamanho máximo da String de dados enviada pelo leitor é de 115 caracteres; 11.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Message Rev. 13 Category Description Messages are divided into categories BOOT Messages about the firmware boot of the reader. CLOCK Messages related to the internal clock process. DNS Messages related to the DNS name resolution process of the SNTP and Syslog servers. HMTL Messages from the reader's internal Web server. INIT Readear startup messages, before firmware boot. INPUT Messages related to the digital input of the reader.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 12 Mensagens de Log do leitor - Syslog Collecting syslog messages from the reader is very important to make a diagnosis of how the reader is behaving in its operating environment. It is recommended to collect messages even if the reader is being used with Wiegand or Abatrack interface.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 13 Regional Regulations 13.1 Frequencies and operating region When booting the Edge-30R Autoid reader, the operating frequencies (Hop-Table) are configured according to the pre-established region in the reader firmware. For the Brazil, the configured frequencies are: ANATEL (Brazil) Edge-30R+ 902 to 907MHz and 915 to 928MHz ANATEL (Brazil) Edge-30R-N 915 to 928MHz 13.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14 Integrated antenna measurements 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14.2 Axial Ratio (±20° Azimuth) 902MHz 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14.4 Axial ratio (±20° Azimuth) 915MHz 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14.6 Axial ratio (±20° Azimuth) 928MHz 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14.8 Radiation diagram (Azimuth) 902MHz 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14.10 Radiation diagram (Azimuth) 915MHz 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 14.12 Radiation diagram (Azimuth) 928MHz 14.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 15 Solutions to common problems 15.1 I do not know the IP of the Reader In this case there are two options. 1. You can use device explorer software (for Windows) to find readers that are on the same LAN network. The software shows readers and their IP and MAC addresses, with the MAC address can physically check the label on the reader's network cable. The figure below shows the device explorer software screen.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid 4. 5. 6. Rev.
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid Rev. 13 ACURA Global is the pioneer in the Radio Frequency Identification (RFID) market in Brazil and Latin America, and has successfully explored, since the late 1990s, its large-scale adoption in the most diverse sectors of the economy, from mining to from agriculture to food processing, from logistics to retail, from transport to the distribution chain, from access control to asset management.