Models: ACK 20 ACK 25 ACK 30 ACK 40 ACK 50 ACK 15 ACK 20 ACK 25 ACK 30 A/AR A/AR A/AR A/AR A/AR B/BR B/BR B/BR B/BR Ceiling Cassette Split Systems Manual No: TMA-ACK-A-1230B
CONTENTS 1. SPECIAL FEATURES ..................................................................................... 2 2. SPECIFICATIONS .......................................................................................... 3 3. NOISE LEVEL ................................................................................................. 9 4. OPERATING RANGE ..................................................................................... 10 5. PERFORMANCE TABLE.........................................
1. SPECIAL FEATURES ULTRA SLIM NEW STYLISH DESIGN PROFILE This unit is contemporary in design and match even the most up to date interior decor. The slim, (only 22 mm for B-series and only 28 mm for A-series) and round profile front panel of this unit adds a touch of elegance to every decor. TURBO MIXED FLOW FAN Innovative design of highly efficient turbo fan produces an even air circulation in all direction.
2.
CEILING CASSETTE (HEAT PUMP) MODEL INDOOR UNIT OUTDOOR UNIT FAN NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY POWER SOURCE REFRIGERANT / CONTROL AIR FLOW kcal/h W Btu/h kcal/h W Btu/h V/Ph/Hz FAN MOTOR COIL FIN INDOOR UNIT TUBE RATED INPUT POWER (W) RATED RUNNING CURRENT (A) MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA DIMENSION HEIGHT ( ) - WITH PANEL WIDTH DEPTH WEIGHT (UNIT + PANEL) SOUND PRESSURE LEVEL ( H / M / L ) ROOM TEMPERATURE CONTROL AIR DISCHARGE OPERAT
CEILING CASSETTE (COOLING ONLY – R407C) INDOOR UNIT OUTDOOR UNIT NOMINAL kcal/h COOLING W CAPACITY Btu/h POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm/cmm FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in THICKNESS mm/in MATERIAL THICKNESS mm/in ROW FIN PER INCH 2 2 FACE AREA m /ft DIMENSION HEIGHT mm/in ( ) - WITH PANEL WIDTH mm/in DEPTH mm/in WEIGHT (UNIT + PANEL) kg SOUND PRESSURE LEVEL ( H / M / L ) dBA ROOM TEMPERATURE CONTROL AIR DISCHARGE OPERATION CONDENSATE DRA
CEILING CASSETTE (HEAT PUMP – R407C) MODEL INDOOR UNIT OUTDOOR UNIT COIL INDOOR UNIT TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR FIN TUBE FAN NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY POWER SOURCE REFRIGERANT / CONTROL AIR FLOW FAN MOTOR RATED INPUT POWER RATED RUNNING CURRENT MATERIAL DIAMETER THICKNESS MATERIAL THICKNESS ROW FIN PER INCH FACE AREA DIMENSION HEIGHT ( ) - WITH PANEL WIDTH DEPTH WEIGHT (UNIT + PANEL) SOUND PRESSURE LEVEL ( H / M / L ) ROOM TEMPERATURE CONTROL AIR DISCH
CEILING CASSETTE (COOLING ONLY) MODEL INDOOR UNIT OUTDOOR UNIT COIL INDOOR UNIT TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR FIN TUBE FAN NOMINAL kcal/h COOLING W CAPACITY Btu/h POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm/cmm FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in THICKNESS mm/in MATERIAL THICKNESS mm/in ROW FIN PER INCH 2 2 m /ft FACE AREA DIMENSION HEIGHT mm/in WIDTH mm/in ( ) - WITH PANEL DEPTH mm/in WEIGHT ( UNIT + PANEL) kg SOUND PRESSURE
CEILING CASSETTE (HEAT PUMP) MODEL INDOOR UNIT OUTDOOR UNIT COIL INDOOR UNIT TUBE FIN COIL PIPE OUTDOOR UNIT FAN COMPRESSOR FIN TUBE FAN NOMINAL kcal/h COOLING W CAPACITY Btu/h NOMINAL kcal/h HEATING W CAPACITY Btu/h POWER SOURCE V/Ph/Hz REFRIGERANT / CONTROL AIR FLOW cfm/cmm FAN MOTOR RATED INPUT POWER W RATED RUNNING CURRENT A MATERIAL DIAMETER mm/in THICKNESS mm/in MATERIAL THICKNESS mm/in ROW FIN PER INCH 2 2 m /ft FACE AREA DIMENSION HEIGHT mm/in mm/in ( ) - WITH PANEL WIDTH DEPTH mm/in WEI
3.
4. OPERATING RANGE Ensure the operating temperature is in allowable range. Cooling only Cooling Caution : Outdoor temp. (°CDB) 54 HIGH AMBIENT UNIT 46 The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 35 STD 19 LOW AMBIENT KIT -5 24 15 Indoor temp. (°CWB) Heat pump Heating Cooling 54 Outdoor temp. (°CDB) Outdoor temp. (°CWB) 18 6 STD -8 HIGH AMBIENT UNIT 46 35 STD 19 LOW AMBIENT KIT -5 15 21 27 15 Indoor temp.
5. PERFORMANCE TABLE MODEL : ACK20A / ALC20B Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 25 5.353 5.353 5.644 5.333 6.439 5.278 6.809 5.252 6.968 5.241 7.498 5.205 8.028 5.168 5.146 5.146 5.431 5.114 6.211 5.026 6.574 4.986 6.709 4.951 7.156 4.837 7.604 4.722 Outdoor DB, ° C 30 35 4.961 4.961 5.242 4.918 6.007 4.802 6.365 4.747 6.477 4.692 6.851 4.508 7.225 4.324 4.776 4.776 5.052 4.723 5.804 4.577 6.155 4.509 6.245 4.433 6.
MODEL : ACK40A / ALC40C Indoor DB °C 26.7 Indoor WB °C 13.9 15 18 19.4 20 22 24 Capacity kW TC SC TC SC TC SC TC SC TC SC TC SC TC SC 19.4 Outdoor DB, ° C 30 35 25 40 46 11.260 10.642 10.090 9.538 8.986 8.324 9.934 9.595 9.292 8.989 8.687 8.324 11.857 11.181 10.578 9.975 9.372 8.648 9.661 9.339 9.051 8.764 8.476 8.131 13.483 12.652 11.909 11.167 10.425 9.534 8.919 8.642 8.396 8.149 7.902 7.606 14.242 13.338 12.531 11.723 10.916 9.947 8.572 8.317 8.089 7.
6.
OUTDOOR UNIT ALC 30/ 40/ 50C/CR A4LC 30/ 40/ 50 C/CR 14
7.
INDOOR UNIT (COOLING ONLY) MODEL : ACK 30A (C3A BOARD) OUTDOOR UNIT MODEL : ALC / A4LC 30C 16
INDOOR UNIT (COOLING ONLY) MODEL : ACK 40/ 50A (C3A BOARD) OUTDOOR UNIT MODEL : ALC / A4LC 40/ 50C 17
INDOOR UNIT (HEAT PUMP) MODEL : ACK 20/ 25AR (C3A BOARD) OUTDOOR UNIT MODEL : ALC / A4LC 20/ 25BR 18
INDOOR UNIT (HEAT PUMP) MODEL : ACK 30AR (C3A BOARD) OUTDOOR UNIT MODEL : ALC / A4LC 30CR 19
INDOOR UNIT (HEAT PUMP) MODEL : ACK 40/ 50AR (C3A BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 40/50CR 20
INDOOR UNIT (COOLING ONLY) MODEL : ACK 20/25A (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 20/25B 21
INDOOR UNIT (COOLING ONLY) MODEL : ACK 30A (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 30C 22
INDOOR UNIT (COOLING ONLY) MODEL : ACK 30A (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC 30B 23
INDOOR UNIT (COOLING ONLY) MODEL : ACK 40/50A (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 40/50C 24
INDOOR UNIT (HEAT PUMP) MODEL : ACK 20/25AR (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 20/25BR 25
INDOOR UNIT (HEAT PUMP) MODEL : ACK 30AR (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 30CR 26
INDOOR UNIT (HEAT PUMP) MODEL : ACK 40/50AR (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC/A4LC 40/50CR 27
INDOOR UNIT (COOLING ONLY ) MODEL : ACK 15B (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC15B 28
INDOOR UNIT (COOLING ONLY ) MODEL : ACK 20/25B (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC20/25B 29
INDOOR UNIT (COOLING ONLY ) MODEL : ACK 30B (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC30C 30
INDOOR UNIT (COOLING ONLY ) MODEL : ACK 30B (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC 30B 31
INDOOR UNIT (HEAT PUMP) MODEL : ACK 15BR (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC 15BR 32
INDOOR UNIT (HEAT PUMP) MODEL : ACK 20/ 25BR (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC 20/ 25BR 33
INDOOR UNIT (HEAT PUMP) MODEL : ACK 30BR (UNIVERSAL BOARD) OUTDOOR UNIT MODEL : ALC 30CR 34
ATTACHMENT 60HZ OUTDOOR UNIT MODEL : ALC 30C (COOLING ONLY) 60HZ / 1 PHASE / 208 ~230V MODEL : ALC 40/50C (COOLING ONLY) 60HZ / 3 PHASE / 200 ~230V MODEL : ALC 40/50CR (COOLING ONLY) 60HZ / 3 PHASE / 200 ~230V 35
3 PHASE FOR 2 & 3 HP OUTDOOR UNIT MODEL : ALC 20/25B (COOLING ONLY) 3 PHASE / 50 HZ / 380 ~ 415V MODEL : ALC 30C (COOLING ONLY) 3 PHASE / 50 HZ / 380 ~ 415V 36
MODEL : ALC 20/25BR (HEAT PUMP) 3 PHASE / 50HZ / 380 ~ 415V MODEL : ALC 30CR (HEAT PUMP) 3 PHASE / 50HZ / 380 ~ 415V 37
HIGH AMBIENT UNIT OUTDOOR UNIT MODEL : ALC 20/25B (COOLING ONLY) 50HZ / 1 PHASE / 220 – 240V, 60HZ / 1 PHASE / 208 – 230V OUTDOOR UNIT MODEL : ALC 30C (COOLING ONLY) 50HZ / 1 PHASE / 220 – 240V, 60HZ / 1 PHASE / 208 – 230V OUTDOOR UNIT MODEL : ALC 40/50C (COOLING ONLY) 50HZ / 3 PHASE / 380 – 415V, 60HZ / 3 PHASE / 200 – 230V 38
OUTDOOR UNIT MODEL : ALC 20/25BR (HEAT PUMP) 50HZ / 1 PHASE / 220 – 240V OUTDOOR UNIT MODEL : ALC 30CR 50HZ / 1 PHASE / 220 – 240V, 60 HZ / 1 PHASE / 220V OUTDOOR UNIT MODEL : ALC 40/50CR 50HZ / 3 PHASE / 380 – 415V, 60HZ / 3 PHASE / 220V 39
LOW AMBIENT UNIT (OPTIONAL) OUTDOOR UNIT MODEL : ALC 10B / 15B (50HZ) OUTDOOR UNIT MODEL : ALC 20B / 25B (50HZ) 40
LOW AMBIENT UNIT OUTDOOR UNIT MODEL : ALC 10/15BR 50HZ / 1 PHASE / 220 – 240V OUTDOOR UNIT MODEL : ALC 20BR 50HZ / 1 PHASE / 220 – 240V OUTDOOR UNIT MODEL : ALC 25BR 50HZ / 1 PHASE / 220 – 240V 41
8. SPECIAL PRECAUTIONS FOR R407C Special precautions when dealing with refrigerant R407C unit 1) WHAT IS NEW REFRIGERANT R407C? R407C is a zeotropic refrigerant mixture which has zero ozone depletion potential and thus conformed to the Montreal Protocol regulation. It requires Polyol ester oil (POE) oil for its compressor's lubricant. Its refrigerant capacity and performance are about the same as the refrigerant R22.
c) Ensure that the compressor is not expose to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal-plugs only when the compressor is about to be brazed. d) The system should be thoroughly vacuumed to 1.0 Pa (-700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system.
9. INSTALLATION OF INDOOR UNIT Caution : Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them. PRELIMINARY SITE SURVEY • • • Beam • Electrical supply and installation is to conform to local authority's (e.g. National Electrical Board) codes and regulations. Voltage supply fluctuation must not exceed ± 10% of rated voltage. Electricity supply lines must be independent of welding transformer which can cause high supply fluctuations.
UNIT HANGING Indoor Unit Ceiling Board 35.0 mm ACK-A ACK-B • Confirm the pitch of the hanging rod is 790.0mm X 620.5mm (ACK-A) / 600.0mm x 582.0 mm (ACK-B). • Hold the unit and hang it on the hanging rod with the nut and washer. • Adjust the unit height to 35.0 mm (ACK-A) / 25.0 mm (ACK-B) between the indoor unit bottom surface and the ceiling surface. • Confirm with a level gauge that the unit is installed horizontally and tighten the nut and bolt to prevent unit falling and vibration.
PANEL INSTALLATION • The front panel can only be fitted in one direction, follow the piping direction. (Follow piping arrow sticker on front panel). • Be sure to remove the installation template before installing the front panel. • Open the air intake grille by pulling back the catchers and remove it together with filter from panel. • Install the front frame panel onto the indoor unit by using 4 screws and tighten it completely to prevent cool air leakage.
AIR INTAKE GRILLE INSTALLATION • Before installed the air intake grille, make sure the air filter is clip properly to the air FRAME (OPTIONAL ITEM) intake grille. • Install the air intake grille together with the air filter to the front panel. IONIZER FILTER (OPTIONAL ITEM) • The grille can be fit in any direction, when selecting direction, the ceiling design and grille operability should be considered.
11. REFRIGERANT PIPING WORK Refrigerant piping is important in particular. Refrigeration cycle of the split air conditioner is realized by the perfect piping work. PIPING LENGTH AND ELEVATION If the piping is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to flow of refrigerant increases, thus lowering the cooling capacity and as a result overloading the compressor which may cause the compressor to become defective.
Heat pump MODEL INDOOR ACK20AR ACK25AR ACK30AR ACK40AR ACK50AR OUTDOOR ALC20BRK ALC25BRK ALC30CR ALC40CR ALC50CR L=7m 0.050 0.100 0.100 0.100 0.100 L = 10 m 0.075 0.500 0.250 0.250 0.250 L = 15 m 0.150 0.750 0.500 0.500 0.500 L = 20 m - - 0.750 0.750 0.750 L = 35 m - - 1.500 1.500 1.500 INDOOR ACK15B ACK20B ACK25B OUTDOOR ALC15B ALC20B ALC25B ALC30B ALC30C L 5m 0.250 0.250 0.100 0.100 0.400 L=7m 0.300 0.280 0.176 0.200 0.600 L = 10 m 0.
13. INDICATOR LIGHTS REMOTE CONTROL When there is infrared remote control operating signal, the signal receiver on indoor unit will made a for signal acceptance conformation.
WIRELESS REMOTE CONTROL (UNIVERSAL BOARD) Cooling : LED Indicator Light Display POWER TIMER Heatpump : LED Indicator Light Display SLEEP POWER TIMER HEAT Operation / Faulty Indication POWER TIMER m m m m SLEEP HEAT Timer on m Sleep mode on m ¤ Heat mode m/l Continuously ¤ Frost prevention mode Compressor overload Once every 3 sec ¤¤ Pump fault Twice every 3 sec ¤¤¤ Gas leak 3 Times every 3 sec Room/indoor/outdoor coil sensor contact loose/short ¤¤¤¤ 4 Times every 3 sec m ON
14. ACCESSORY PARTS SHORT DUCT SPECIFICATION • The indoor unit is provided with air discharge and air intake "knock-out". hole for duct connection. However the connection of the short duct for air discharge is possible on only one side. • The use of short duct for air discharge will improve airflow distribution if there is an obstruction (such as alighting fixture) or in a long, narrow room or an L-shaped room. It is also used for air conditioning of two rooms simultaneously.
SEALING MATERIAL • It is possible to seal one of the four air discharge outlet (sealing two or more air discharge outlet could cause a malfunction). Remove the front panel and inserting the seal material into the air discharge outlet at the indoor unit to seal the air outlet. The sealing material is the same length as the longer air discharge outlet. If it is desired to seal the shorter air discharge outlet, cut the sealing material to shorten it.
17. REMOTE CONTROL OPERATION GUIDE G6 REMOTE CONTROLLER 7 8 FAN SPEED AND VENTILATION MODE SELECTION Press the button until the desired fan speed is achieved. 2 SIGNAL TRANSMISSION INDICATION • Blink to confirm the last setting has been send to the unit. TEMPERATURE SETTING • • 6 OPERATION MODES • Press the “mode” button for select the type of operating mode. • Cooling only unit: Cool →Dry →Fan.
8 10 9 4 SENSOR 4 ON/OFF AUTO 2 TEMP HIGH MED TIMER ON/OFF 2 COOL FAN DRY HEAT MODE 3 FAN LOW 5 1 FAN 1 SWING TEMP 7 SLEEP 6 SWING SLEEP TIMER MODE 6 3 5 7 SLM AC-5300 (OPTIONAL) 6. “Sleep” mode • Press button to activate the sleep function. This function can only be activated under “cool” or heating mode operation. When it is activated under “cool” mode operation, the set temperature will increase 0.5oC after 30 minutes, 1oC after 1 hour and 2oC after 2 hours.
G8 REMOTE CONTROLLER 1 2 3 6 5 12 8 7 9 4 10 11 1. Transmission source • The source where the signal will be transmitted. 2. Signal Transmission indication • Blink to confirm the last setting has been send to the unit. 3. On/Off Button • Press once to start the air conditioner. • Press again to stop the unit. 4. Temperature setting • To set the desired room temperature, press the button to increase or decrease the set temperature.
18. SERVICE AND MAINTENANCE Warning: Disconnect from main supply before servicing the air conditioner. The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Air filter (Indoor Unit) Indoor unit Condense Drain Pan & Pipe Indoor Fan Maintenance Procedure 1. Remove the ionizer filter before cleaning the filter. 2.
19. PRE START UP MAINTENANCE After Extended Shutdown • Inspect thoroughly and clean indoor and outdoor units. • Clean or replace air filter. • Clean condense drain line. • Clean clogged indoor and outdoor coils. • Check fan imbalance before operation. • Tighten all wire connections. • Check for refrigerant leakage, Note: The crankcase heater should be energized for at least 6 hours before start of operation (after extended shutdown). 20.
21. PARTS LIST UNIT ( NEW HANGER ) 14 22 1 21 2 3 13 4 18 5 15 20 17 16 7 6 8 33 19 29 9 25 10 24 30 11 34 12 28 23 32 27 31 34 26 34 NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PARTS DESCRIPTION BASE PAN FAN MOTOR FAN MOTOR BUSH PLAIN WASHER FAN MOTOR WASHER BOTTOM COUPLING TURBO FAN TOP COUPLING FLAT WASHER PLAIN WASHER SPRING WASHER HEXAGON BOLT HEXAGON BOLT EVAPORATOR COIL DRAIN PUMP BRACKET DRAIN PUMP DRAIN PUMP BUSH NO.
UNIT ( WITH OLD HANGER BRACKET ) 14 22 1 21 3 2 4 15 20 13 5 18 6 17 7 16 35 8 29 19 9 25 10 11 30 12 24 28 23 32 27 31 26 34 NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PARTS DESCRIPTION BASE PAN FAN MOTOR FAN MOTOR BUSH PLAIN WASHER FAN MOTOR WASHER BOTTOM COUPLING TURBO FAN TOP COUPLING FLAT WASHER PLAIN WASHER SPRING WASHER HEXAGON BOLT HEXAGON BOLT EVAPORATOR COIL DRAIN PUMP BRACKET DRAIN PUMP DRAIN PUMP BUSH HEXAGON BOLT NO.
PANEL ( WIRELESS REMOTE CONTROL ) 15 2 5 1 6 7 11 9 14 8 10 12 4 13 22 3 19 21 20 16 23 17 18 NO. PART DESCRIPTION NO.
PANEL (WIRED REMOTE CONTROL) 15 5 1 7 11 9 14 8 10 12 4 13 6 3 19 2 20 16 21 17 22 18 PART DESCRIPTION NO.
MODEL : ALC 20B / 25B NO PARTS DESCRIPTION NO PARTS DESCRIPTION 1 ASSY., BACK PANEL 17 GROMMET, RUBBER 2 ASSY., TOP PANEL 18 NUT, WITH WASHER 3 ASSY., CONDENSER COIL 19 ASSY., BASE PAN 4 BRACKET, MOTOR MOUNTING 20 ASSY., CAPILLARY TUBE 5 MOTOR, FAN 21 ASSY., PARTITION 6 FLINGER 22 ASSY., TERMINAL BOX PANEL W/O CONT. 7 WASHER, RING 23 ASSY., SIDE PANEL 8 FAN BLADE 24 ASSY., ACCESS PANEL 9 WASHER, SQUARE 25 PLATE, FLARE VALVE 10 HEX. NUT 26 VALVE, FLARE C/W ACC.
MODEL : ALC 30/ 40/ 50 C/ CR NO 1 2 3 4 5 6 7 PARTS DESCRIPTION BASE PAN ASY. ACCESS / SERVICE PANEL CONDENSER COIL ASSY. COMPRESSOR PARTITION PANEL VALVE PLATE ASSY. FAN MOTOR & BRACKET ASSY. NO 8 9 10 11 12 13 64 PARTS DESCRIPTION FAN BLADE FRONT PANEL ASSY. SIDE PANEL LEFT TERMINAL BOX ASSY.