ORION Smart Vibration Monitoring Terminal INSTALLATION & SAFETY INSTRUCTIONS www.acoemgroup.com support@acoemgroup.com Copyright © 2014 - 01dB-Metravib SAS This document is the property of 01dB-Metravib SAS.
Brand of ACOEM
ORION Smart Vibration Monitoring Terminal INSTALLATION & SAFETY INSTRUCTIONS Document reference Name : NOT1561 February 2017 B : ORION Installation & Safety instructions www.acoemgroup.com support@acoemgroup.com Copyright © 2014 - 01dB-Metravib SAS This document is the property of 01dB-Metravib SAS.
TABLE OF CONTENTS 1. Safety Instructions ................................................................................... 7 1.1. General Safety Warnings ................................................................. 7 1.2. Definitions : Safety Guidelines ......................................................... 7 1.3. Safety Labels and markings ............................................................. 7 1.3.1. ID label on the back plate of the instrument ............................. 7 1.3.2.
1.14.2. Charge/Discharge................................................................ 21 1.15. Transportation ............................................................................. 22 1.16. Storage recommendations ......................................................... 22 2. General Presentation ............................................................................. 23 2.1. Introduction ..................................................................................... 23 2.2.
Welcome to the world of 01dB ACOEM would like to thank you for purchasing this 01dB product and invites you to refer to this installation and safety instructions. For more information on 01dB’s products and services, please visit www.01db.com. Receipt of your equipment This product was carefully inspected and tested prior to shipping. Nevertheless, you are requested to check when opening the packaging that there is no sign of damage and that all the accessories are included.
1. SAFETY INSTRUCTIONS 1.1. GENERAL SAFETY WARNINGS WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE. Follow the "Quick Start Guide" and the “User Manual” that can be downloaded on: http://support.01db.acoemgroup.com . 1.2. DEFINITIONS : SAFETY GUIDELINES The definitions below describe the level of severity for each signal word.
Symbol Description Discard the instrument with due care for the environment. CE certification data. Refer to the copy of the UE certificate Warning: Whenever this symbol is present on the device, it is essential to refer to the safety instructions documentation and the user manual. FCC and IC statutory. Refer to section "Radio" FCC and IC number. Refer to section "Radio". 1.3.2.
1.3.3. Markings on the keyboard Symbol Description Power button Power LED Lock LED Sensor error LED Wi-Fi button Wi-Fi LED Memory SD (solid disk) card slot (Behind the hatch) Micro-USB Factory service only (Behind the hatch) SIM card slot (Behind the hatch) Micro-USB Connector (Behind the hatch) Ethernet LED Battery LED for charge level indication Wi-Fi antenna connector GPS Connector GSM antenna connector LED for quality signal 1.3.4.
1.4. OPERATING ENVIRONMENT Don't use this instrument, its accessory and its power supply in explosive atmosphere, or near flammable products, or near corrosive products. 1.4.1. Instrument The instrument has a protection degree IP65 (IEC60529) when hatch is closed and connector's bases are equipped of their protections or their connectors. The instrument has a protection degree IP20 (IEC60529) when hatch is opened.
1.5. MECHANICAL RISK AND WORK AREA SAFETY Keep work area clean and well lit. Cluttered or dark areas invite accidents. Ensure the cables connected to the instrument are secure, protected and fixed to avoid hanging on or falling. A mark-up and/or a mechanical protection must be put in place to protect the instrument As the device is heavy, wear security shoes to prevent injury from a drop.
1.6. ELECTRICAL SAFETY 1.6.1. Generalities All external circuits connected to ORION should be non-hazardous voltage, and energy source limited within the meaning of the IEC61010-1 standard. The power supply must be connected to the mains power equipped with a differential circuit breaker.
1.6.2.2. Standard power supply VMT1004000 GC-ZDL1201500 GIGA-Concept Electronics components Symbol Description Only for indoor use The power supply is double insulated in accordance with EN 60335; therefore no earth wire is required. Discard the power supply with due care for the environment.
- Pull by body rather than cord when disconnecting standard power supply. This will reduce risk of damage to electric plug and cord. 1.6.2.3. Waterproof power supply VMT1007000 Part number LPF-25-12 Symbol Description Product identification The device has reinforced insulation without accessible metal part.
*Device independent auxiliary lighting *For direct mounting on flammable surfaces, such as wood (> 2mm) *Protection to avoid the lamp controlgear overheat whatever the conditions of use excedantes the value indicated (110 ° C) *Could be mounted inside wood part.
1.6.2.4. Existing Power Over Ethernet supply Two cases possible: The existing Power over Ethernet supply to ORION must conform to IEC 61010-1: 2010 and EN 61010-1: 2010 and all their applicable Amendments ". The output circuits of these power supplies must have safe voltage levels and power be limited in the sense of these standards. or The existing Power over Ethernet supply to ORION must comply with IEC 60950-1: 2005 and EN 60950-1: 2006 and all their applicable Amendments.
1.7. PERSONAL SAFETY Stay alert, watch what you are doing and use common sense when installing and operating the instrument. Due to its weight and shape, the manipulation of the instrument can result in minor or moderate injury, especially if the spikes are mounted. In case of use of spikes, the spike protection must remain in place until the instrument is placed at its measurement position. Use personal protective equipment.
1.10. RADIO 1.10.1. General information The instrument is capable of connecting to Wi-Fi and 3G wireless networks. Modems Wi-Fi and 3G are qualified for EMC and safety. This qualification is valid only with the antennas supplied with the unit and referred in this document. The instrument is also capable of receiving GPS satellites data This device complies with FCC and IC RF radiation exposure limits set forth for general population.
2. IC: (industry Canada) Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
1.11. ACCESS HATCH The access hatch must be opened only in an office atmosphere with a deskcounter pollution less than 2. Do not forget to mount it before going on a job site 1.12. VENT VALVE The instrument has a breath valve with a membrane which allows respiration, but stop humidity. Breathing valve must not be obstructed or blocked 1.13. SERVICE The disassembly for internal repair is prohibited.
Do no place the battery into fire or close to any other temperature source (> 70°C). This action may cause overheating, even start a fire. This type of use may also lead to degraded performances and to a significantly reduced lifetime for the battery. Immediately disconnect the power supply in the event of one of the following situations: o unusual odour o unusually high temperature 1.14.2. Charge/Discharge The battery is charged by an internal charger.
1.15.
2. GENERAL PRESENTATION 2.1. INTRODUCTION ORION is a new generation upgradeable vibration measuring instrument, integrating innovative technology. The programming of all available functions (Input / Output / Storage…) allows meeting best the user’s requirements.
2.3.
14 15 14 Bottom view 14 – Adjustable screws 15 – Not adjustable screw 2.4. INPUTS SENSORS DESCRIPTION 2.4.1. Triaxial internal Accelerometer The device internally has a triaxial accelerometer to perform the majority of the measurements. 2.4.2. Triaxial external transducer It is also possible to connect on C1 connector in place of or in parallel to the internal sensor an external triaxial accelerometer sensor or triaxial velocity meter sensor.
2.6. ACCESS HATCH The waterproof access hatch must be screwed using the knurled head screws with the torque allowing the user to unscrew them with fingers. It gives access to several slots: SD card slot Sim card slot Micro USB connectors for USB host connection (allows for reading the SD card content) and factory service 3. INSTALLATION The equipment can be deployed in different configurations. All configurations are not allowed according to the environment.
3.3. INSTALLATION OF THE ORION WITH THE OPTIONAL MOUNTING PLATE The ORION could be fixed on concrete floor or wall using the optional mounting plate (VMT1013000A). The 4 M6 screws needed to fix the ORION on the Interface plate are included in the delivery. The 3 expanding studs needed to fix the mounting plate on the concrete are not delivered and must be selected by the operator according to the type of wall support.
04 01 04 04 03 02 04 01 – Wall/floor fixation point #1 02 – Wall/floor fixation point #2 03 – Wall/floor fixation point #3 04 – ORION fixation point on mounting plate 3.4.
If the TTL output of the instrument ORION is connected to a device, this device should be non-hazardous voltage and energy source be limited within the meaning of the IEC61010-1 standard The radio device (WIFI, GSM-3G, GPS) may be used in accordance of national regulations (RED, FCC, IC). 3.5. EARTH CONNECTION The protective Earth connexion is possible on the screw terminal using the cable as shown on the picture. The recommended tightening torque is 3N.m. The screw is furnished (M8).
3.6. GENERAL INSTALLATION SCHEME TTL input device GPS patch antenna Ext. Power supply C3 (power supply) or C4(PoE) Ext. sensor Protective Earth All additional devices (GPS patch, TTL input, External sensor) could be connected from indoor to outdoor. In this case a protective earth has to be installed (§3.5 Earth connection). The maximum length of the cable is 10 meters. 4. M AINTENANCE 4.1. GENERALITIES The device does not need maintenance or adjustment excluding cleaning and battery replacement.
Brand of ACOEM
ACOEM Smart monitoring, diagnosis & solutions In today’s complex and increasingly fast-moving world, it is essential to keep risks under control.