MTU Instructions ALL MTU Instructions as of 10/1/2009 Instructions Included Document Page 471-2000 – General Installation & Wiring Guidelines ........................................................ 3 471-2001 – for Rockwell/Equimeter/Sensus Gas Meters (Direct Mount).......................... 15 471-2002 – for Most Popular Water Meters........................................................................ 19 471-2003 – for American Meter Company Gas Meters (Direct Mount) .............................
MTU Instructions ALL MTU Instructions as of 10/1/2009 Instructions Included (Continued) Document Page 471-2031 – for Actaris/Schlumberger/Sprague ‘Slant-face’ Gas Meters........................137 471-2032 – for Armorcast Composite Pit Lids..................................................................141 471-2033 - for Actaris/Schlumberger/Sprague Pit/Curbside Gas Meters ......................145 471-2034 – for American Meter Company 5B-225 Gas Meters........................................
MTU Instructions General Installation and Wiring Guidelines Intentionally Left Blank The FCC wants you to know….. This equipment has been tested and complies with Part 15 and Part 90 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
MTU Instructions General Installation and Wiring Guidelines Purpose & Scope This instruction outlines general practices and procedures for the installation and wiring of standalone, electronic interface Hexagram STAR MTUs. When installing an MTU, always refer to these instructions in addition to any specific instructions for the meter/MTU combination you will be installing and programming.
MTU Instructions General Installation and Wiring Guidelines Recommended Supplies We recommend the following supplies, for which quantities will depend upon the number of MTUs to be installed and the conditions encountered at each installation location. Item AMP Tel-Splice, 2-conductor Scotchlok, UR 2-3 wire gel-filled butt connector 3-conductor, 22 ga, solid wire, black UV jacket 3-conductor, 22 ga, solid wire, grey UV jacket AA alkaline battery, 1.
MTU Instructions General Installation and Wiring Guidelines Recommended Tools MTU Wiring • General - Many MTUs connect to the meter by means of a 3-conductor, 22gauge solid conductor wire. The wire is housed in a PVC jacket with UV inhibitors. A black-jacketed wire is supplied on single-port MTUs and for port 1 of dual-port MTUs. A grey jacket is used for the port two input to dual port MTUs.
MTU Instructions General Installation and Wiring Guidelines They must be secure and made in accordance with the connection supplier’s instructions. Generally, gel-filled Insulation Displacement Connectors (IDCs) such as 3M ScotchLok or AMP Tel-Splice connectors should be used on all wire-to-wire connections. Since MTU transmissions are similar in nature to cellular phone signals, a cellular phone can be used to help to determine if a location is suitable for MTU mounting.
MTU Instructions General Installation and Wiring Guidelines NEW Flatpak STAR MTU – An example of the NEW Flatpak STAR MTU is shown below. These MTUs are approximately 6.5” x 4.25” x 1.5” thick, and can be mounted on most surfaces without the use of a spacer. Original Flatpak STAR MTU – An example of an Original Flatpak STAR MTU is shown below. These MTUs are 6.5” x 5.5” X 1” thick, and require a spacer if mounted on any material other than wood.
MTU Instructions General Installation and Wiring Guidelines Outdoor Mounting MTUs mounted outdoors are typically mounted to the side of buildings, to a stationery post, to the piping surrounding the meter, or to a pit lid. Mounting to a Buiding or Post If the unit is being mounted to the outside of a building, the MTU will be connected to wires that lead from the inside to the outside of the building. If existing wire is used, it must be of the same quality as specified in MTU Wiring.
MTU Instructions General Installation and Wiring Guidelines Step 2 - Attach the spacer to the MTU using #10-32 stainless steel screws, nuts and washers. Tighten the screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Pit-Lid Mounting For water or gas meters located in meter pits, MTUs can be mounted to the lower surface of the pit lid if an approved, nonmetallic pit lid is used.
MTU Instructions General Installation and Wiring Guidelines A long spacer is available, for use when the lower surface of the pit lid is a flat, solid surface. A short spacer is used when the lower surface of the pit lid in use has a ribbed construction. Do not mount the MTU if large metal objects, such as heating ducts, block both the front and rear of the MTU. If absolutely necessary, a single large metal object may be located several feet away from the MTU.
MTU Instructions General Installation and Wiring Guidelines Step 3 – Run wiring from the MTU to the meter. Carefully staple the wire to the wall every 18” and at every change in direction using 9/16” staples. All turns are to be at right angles. If wire must be run on masonry, secure it with wire clips. Run wires parallel to the joist. If a joist must be crossed, run at a 90 degree angle. If the MTU input cable must be extended, use an appropriate splice.
MTU Instructions General Installation and Wiring Guidelines Do 9 Do check your cell phone for presence of a strong signal before entering a building or basement. Do install the MTU if the signal remains strong at the installation location. (Note: This is a guideline only. It does not guarantee that the MTU will be received by the DCU. However, if cell phone service is affected by the location, it is possible that the MTU transmission will also be blocked.
MTU Instructions General Installation and Wiring Guidelines Don’t 9 Don’t install the MTU if the cell phone signal was strong outside the building or basement and then goes into “no service” or a very weak signal at the MTU installation site. 9 Don’t select a location for MTU installation that is easy to install, but will not allow for good signal transmission. 9 Don’t select a location for MTU installation that is below grade.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Rockwell/Equimeter/Sensus meters: R175, R200, R250, R275, R310, R315, RT210. Parts Required Ref.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Step 4 – Turn the MTU over and insure that there is a pre-applied gasket on the back of the MTU as shown below.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 8 – Select gear to fit between the register and the MTU without binding. Typically, the correct gear can be selected based upon the type of index in use, as shown in the following table. Type of Index Step 9 - On the register, insert the screws and spacers. Coupler Drive Gear Plastic, dialtype Blue Gear (Part # 056-5155G4) Brass, dialtype Red Gear (Part # 056-5155G3) Note: Spacers may not be required with odometer-style registers.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 11 - After you feel engagement between the index register gear and the MTU coupler gear, tighten the register screws until they are snug. Step 12 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds.
MTU Instruction for Most Popular Water Meters Purpose & Scope This instruction provides wiring information for connecting STAR MTUs to any of the following popular water meters: • AMCO and/or ABB water meters (all sizes) equipped with Invision, Scancoder, RS Pulser, or Type A Industrial Pulser registers and with the AMCO/ABB V100 (PSMT) meter and the S130/5UM hot and cold water meters. • Neptune and/or Schlumberger water meters (all sizes) equipped with ARB-V, Auto/ProRead or E-Coder PLUS registers.
MTU Instruction for Most Popular Water Meters Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. AMCO/ABB Scancoder Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional.
MTU Instruction for Most Popular Water Meters AMCO/ABB Type A Industrial Pulser MTU Cable Type A Industrial Pulser Register Red + Positive AMCO/ABB V100 (PSMT) MTU Cable V100 (PSMT) Cable Red Red Black Blue White Blue Black - Negative No Connection Black White - Negative No Connection Yellow AMCO S130/5UM Hot Water AMCO Digital Register MTU Cable S130/5UM Cable MTU Cable AMCO Digital Register Red Brown Red R (Red) Black White Black B (Black) White White White B (Black)
MTU Instruction for Most Popular Water Meters AMCO S130/5UM Cold Water Neptune/Schlumberger E-Coder PLUS MTU Cable E-Coder PLUS Register MTU Cable S130/5UM Cable Red Brown Red B (Black) Black White Black G (Green) White White White R (Red) Neptune/Schlumberger ARB-V or Auto/ProRead MTU Cable ProRead Register Red B (Black) Black G (Green) White R (Red) Note: Auto/ProRead registers must be programmed for 3-wire mode.
MTU Instruction for Most Popular Water Meters Hersey Translator Badger RTR MTU Cable RTR Cable MTU Cable Hersey Register Red R (Red) Red R (Red) Black B (Black) Black B (Black) White G (Green) White G (Green) Note: The Hersey Translator Register must be programmed for 6-digit readings for proper operation with STAR MTUs.
MTU Instruction for Most Popular Water Meters Badger ADE Metron OER Register MTU Cable ADE Cable Red R (Red) Black B (Black) White G (Green) Note: The Badger ADE register must be programmed for 6-digit readings for proper operation with a STAR MTU.
MTU Instruction for American Meter Company Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following American Meter Company meters: AC-175, AL-175, AT-175, AC-250, AL-250, AM-250, AR-250, AT-210/250, AT-350, AL-425, AC-630. Parts Required Ref.
MTU Instruction for American Meter Company Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • Phillips screwdriver • Slotted screwdriver Installation Procedure Before installing the MTU, all anti-tamper, safety, and security hardware must be removed from the clear register cover. Step 1 - Remove the existing clear register cover by removing the four screws that hold it. Discard both the screws and the cover.
MTU Instruction for American Meter Company Gas Meters Step 4 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Step 5 – Next, Insert the two ¼-20 x 1 1/4” machine screws through the holes on the MTU as shown here. Half-foot Drive Quarter-foot Drive Step 8 – Now, firmly hand tighten the two screws to 12 to 15 in-lb. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure.
MTU Instruction for American Meter Company Gas Meters Step 11 – Replace any anti-tamper, safety, or security hardware onto the plastic cover as required. Page 28 Step 12 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer.
MTU Instruction for American Meter Company Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR indirect-mount MTU on the following American Meter Company meters: 5B-225, 225. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Ref.
MTU Instruction for American Meter Company Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • • Cordless drill ⅜”, variable speed, adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver 7/16″ nutdriver or boxwrench Diagonal side cutter Installation Procedure Step 4 - If the meter has a stamped metal right angle drive foot, orient the drive foot of the index to the position
MTU Instruction for American Meter Company Gas Meters Step 5 - If the meter has a round plastic pin, align the register to the American 225 Meter Adapter. The pin on the register must be in the hole in the coupler, as shown. Make sure the index foot rotates freely. Step 9 - Mount register with adapter and the original plastic cover to the meter. Step 10 - Attach the register and adapter assembly to the meter with the four ¼-20 x 2 fillister head screws. Tighten the screws to 12 to 15 in-lb.
MTU Instruction for American Meter Company Gas Meters Step 2 - Attach the spacer to the MTU using the provided screws and washers. Tighten the screws to 12 to 15 in-lb. On a standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Step 4 - Adjust the MTU as needed and pull the tie wraps tight. Step 5 - Trim off the excess tie wrap, leaving about a ½” tab.
MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to a Carson Industries Model 1419-3 or 1419-5 pit lid. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions.
MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Installation Procedure Step 1 - Mount the drilling fixture onto either model of the Carson Pit Lid. The fixture is keyed so that it will align in only one direction. Step 2 - Hold the fixture secure in position on the lid and drill two holes into the lid using the supplied 17/64” drill bit, through the guide holes in the fixture. Step 5 - Insert 2 stainless screws through the holes drilled in the top side of the lid.
MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Step 8 - Turn the lid over and verify that the heads of the screws are flush or below the lid surface. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 9 – Wire the MTU to the meter, folding and forming wires into valve box as necessary so that they do not interfere with lid locking mechanism and cannot become pinched.
MTU Instruction for Carson Industries 1419-3 and 1419-5 Pit Lids Intentionally Left Blank Page 36
MTU Instruction for Armor Access Rubber Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to an Armor Access brand rubber composite pit lid. This procedure covers the mounting of an Original Flatpak STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit.
MTU Instruction for Armor Access Rubber Pit Lids Installation Procedure through the recessed mounting holes as shown. Torque screws to approximately 8 in-lbs. MTU should be snug and flush to the surface of the pit lid. Pit Lid with No Recess Mounting an Original Flatpak STAR MTU to an Armor Access pit lid. Step 1 – If there is a recess on the bottom surface of the pit lid, place the MTU into the recess. If no recess, center the MTU as shown onto the inside surface of the lid.
MTU Instruction for Armor Access Rubber Pit Lids Mounting a New Flatpak STAR MTU to an Armor Access pit lid. Step 1 – Center the MTU as shown onto the bottom surface of the pit lid. Place plastic spacers under the mounting lugs on the MTU as shown below. Be sure to use the long spacers (Hexagram Part Number 056-8150L). Step 3 – Wire the MTU to the meter, making sure that the wire is routed so that it does not become pinched when the lid is closed. Step 4 - Installation is now complete.
MTU Instruction for Armor Access Rubber Pit Lids Intentionally Left Blank Page 40
MTU Instruction for Invensys Icon MTU/Electric Meter Assembly Purpose & Scope This instruction provides a procedure for installing FORM 2s and FORM 12S Invensys Icon MTU/Electric Meter Assemblies. Supplies and Tools Required Physical Installation of the ICON Form 2S and Form 12S MTU/Electric Meter Assemblies into compatible meter sockets can be accomplished without the use of tools.
MTU Instruction for Invensys Icon MTU/Electric Meter Assembly Step 2 – (For Form 12S meters only – Skip this step for Form 2S meters) The neutral-blade of the Form 12S meter can be moved. The figure below shows the rear of the meter base with the neutralblade in the factory default, 9 o’clock position (referenced by looking into the meter socket.) e. Replace screws – Place the two screws in the new neutral-blade location.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Purpose & Scope This instruction provides procedures for installing and programmin STAR MTUs equipped with voltage or temperature sensing pulse adapters including the following: 501-7786P, 501-7786T, 501-7786-PP, 501-7786PR, 501-7786PT, 501-7786PT2. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Tools Required • • • • Crimping Pliers for Insulation Displacement Connectors (IDCs) Wire cutters/stripper Cleaner (non-residue type) and rag/paper towel Stapler for ¼” wire and cable (Arrow T-25M) Introduction STAR Submetering MTUs with Pulse Adapters provide accurate, highresolution data for point-of-use allocation billing for a wide variety of HVAC appliances.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Step 3 – Connect the RED and BLACK leads from the MTU across (in parallel with) the 24 VAC control input to the gas valve. On most gas valves, these connections can be made at the terminals on the gas valve solenoid. Step 4 – Program the MTU using the MTU Programmer as outlined in the Programming section of this document. Step 5 - Return the furnace setting to "Run".
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Gently shape the copper sleeve on the thermocouple so that it does not contact the metal surface of the draft hood or the top of the hot water tank as shown in the side view illustration. Step 3 - Clean the surface area of the hot water heater under the thermocouple. Dry thoroughly. Locate and mount the two pressure sensitive hold-downs in the cleaned area.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Step 4 - Mount the MTU on a wall, joist or other convenient mounting location well away from the heat source using two screws. CAUTION The MTU must be located away from the appliance and ONLY in a location that remains at room temperature. Run the cable from the MTU to the end of the thermocouple wire. Trim excess MTU cable, as needed. Care must be taken to protect the cable from damage by hot surfaces or sharp sheet metal.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Step 3 - A screen asking if the operator wishes to change the Psion’s serial number is displayed. NOTE: - At midnight, the software automatically resets to require re-entry of the log-on information. This is a security measure in case the Psion is lost or stolen. Step 5 - The “Set Time & Date” screen is displayed. This number should match the last four digits of the serial number etched on the back of the Psion.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters STAR Programming Software – Main Menu Choices Menu Item Add MTU Add MTU And Replace Meter Function Select this item when a new MTU is being connected to an existing meter. Select this item when a new MTU is being added and the current meter is being replaced. Add MTU And Meter Select this item when a new MTU and meter are being installed where no previous equipment existed.
MTU Instruction for STAR Submetering MTUs with Pulse Adapters Intentionally Left Blank Page 50
MTU Instruction for AMCO and ABB Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to AMCO and/or ABB water meters (all sizes) equipped with Invision, Scancoder, RS Pulser, Type A Industrial Pulser, or AMCO Digital registers and with the AMCO/ABB V100/PSMT meter, and the S130/5UM hot and cold water meters.
MTU Instruction for AMCO and ABB Water Meters b. Water Meter with Integral Cable - If the water meter is supplied with an integral cable and a cable-to-cable splice is necessary, use a gel-filled wire splice designed for outdoor (moisture applications) to seal the individual connections. Type A Industrial Pulser Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register.
MTU Instruction for AMCO and ABB Water Meters Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. S130/5UM Hot Water Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer.
MTU Instruction for AMCO and ABB Water Meters Intentionally Left Blank Page 54
MTU Instruction for Neptune and Schlumberger Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Neptune and/or Schlumberger water meters (all sizes) equipped with ARB-V, Auto/ProRead, or E-Coder PLUS registers. ARB-V or Auto/ProRead E-Coder PLUS MTU Cable ARB-V or Auto/ProRead Register Red B (Black) Black G (Green) White R (Red) Notes: • Auto/ProRead registers must be programmed by the manufacturer for 3-wire mode.
MTU Instruction for Neptune and Schlumberger Water Meters Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000.
MTU Instruction for Neptune and Schlumberger Water Meters • Alarm Polling – The NTG MTU also automatically polls (reads) the E-Coder alarm indicators every 15 minutes. This happens automatically, independently of the standard read interval mentioned above. If the NTG MTU detects any change in the alarm status of the E-Coder Plus register, an alarm transmission is generated immediately, reporting the change in alarm status to the DCUs.
MTU Instruction for Neptune and Schlumberger Water Meters Once the user selects Yes on the above screen and successfully completes programming the NTG MTU for use with an E-Coder Plus register, the NTG MTU can no longer be used with an ARB-V or ProRead register. From this point forward, only E-Coder meter types will be available for selection when programming this NTG MTU.
MTU Instruction for Sensus and Invensys Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Sensus and/or Invensys water meters (all sizes) equipped with ECR or ICE registers. ECR or ICE Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000.
MTU Instruction for Sensus and Invensys Water Meters Step 3 – Make a final visual check of the wiring from the MTU to the meter register. Verify that the cable routing is neat, secure and professional. Page 60 Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer.
MTU Instruction for Hersey Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Hersey water meters (all sizes) equipped with Translator or ER2 registers.
MTU Instruction for Hersey Water Meters a. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw. It is recommended that the screws be tightened to no more than 4 – 5 in-lbs. Overtightening the screw can stress and possibly fracture the wire. b.
MTU Instruction for Badger Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Badger water meters (all sizes) equipped with Read-O-Matic, RTR, or ADE registers.
MTU Instruction for Badger Water Meters outdoor (moisture applications) to seal the individual connections. Read-O-Matic Note: When connecting a dual port MTU to a compound meter, connect port 1 (black jacket) to the primary, or high-flow register and port 2 (grey jacket) to the secondary or low-flow register. b. Direct Wiring to Meter - MTU wiring is supplied stripped to a standard length that fits water meters with screw terminals. Simply wrap the wires around the screw terminal and tighten the screw.
MTU Instruction for MLOG Sensors Purpose & Scope This instruction provides wiring information for use in connecting a STAR encoder-type MTU to a Flow Metrix MLOG Sensor. Use gel-filled wire splices designed for outdoor applications to seal the individual connections. For pit installations, seal and enclose the three individual connections using a direct burial splice kit to complete the waterproof splice.
MTU Instruction for MLOG Sensors Intentionally Left Blank Page 66
MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Purpose & Scope This instruction provides a procedure for use in connecting a STAR MTU to an IMAC Pulsimatic Transmitter and installing the Pulsimatic Transmitter on a Rockwell/Equimeter Model 750-10000 Intermediate or Large Capacity Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Tools Required • • • • • Slotted (Flat-blade) screwdrivers in the following blade tip width sizes: 5/32” narrow-blade, 9/32”, and ½”. If desired, use torque driver, 10 foot-lb. range. ½” combination (hand) wrench or socket/ratchet wrench. A torque wrench is recommended (30 inchlb. range). 8” adjustable wrench. 5/16-18 blind-hole (bottoming) tap and mating size T-handle. Canned compressed air.
MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Step 7 – Pull most of the slack out of the cable (leave a slight amount of slack) and reattach cable clamp as shown below. DO NOT pull the cable taut. Installing the Pulsimatic Transmitter Step 1 – If necessary, remove tamper seals that cover the index cover screws. Loosen and remove screws securing the index cover. You may discard these screws as they will not be re-used. Remove the cover.
MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Step 3 – If the index cover screws were difficult to remove, the threads in the index plate may need to be cleaned out before installing the hardware that retains the IPT. Use the blind-hole tap to carefully clean out/ clean up the threads of the (2) cover holes. Blow out the holes with compressed (canned) air. NOTE: It is not necessary to clean the index mounting-hole threads as these holes are not reused.
MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Step 9 – Place the index cover onto the studs. It will fit over the index one way only. Apply a flat washer and nut onto each stud. Snug, and then tighten these nuts an additional ½ to ¾ turn maximum. The finished torque value is 25 – 30 inchlb. Step 10 – Install Wire/Lead security seals if desired. Installation is complete.
MTU Instruction for Rockwell/Equimeter Model 750-10000 Gas Meters Intentionally Left Blank Page 72
MTU Instruction for American Model AL800-AL5000 Gas Meters Purpose & Scope This instruction provides a procedure for use in connecting a STAR MTU to an IMAC Pulsimatic Transmitter and installing the Pulsimatic Transmitter on an American Model AL800-AL5000 Industrial & Commercial Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for American Model AL800-AL5000 Gas Meters Tools Required • Slotted (Flat-blade) screwdrivers in the following blade tip width sizes: 5/32” narrow-blade, 9/32”, and ½”. • ½” combination (hand) wrench or socket/ratchet wrench. A torque wrench is recommended (60 inch-lb. range). • 8” adjustable wrench. • 18-18 blind-hole (bottoming) tap and mating size T-handle. • Canned compressed air.
MTU Instruction for American Model AL800-AL5000 Gas Meters Step 7 – Pull most of the slack out of the cable (leave a slight amount of slack) and reattach cable clamp as shown below. DO NOT pull the cable taut. Step 8 – Tighten the nut on the sealtight strain relief. You will need to tighten the nut almost fully down (as shown) before it will bite on the MTU cable. Step 9 – Check that all wired terminal block screws are tight.
MTU Instruction for American Model AL800-AL5000 Gas Meters Step 3 – Place the adapter plate contained in the installation parts onto the head of the meter with the ear holes aligned over the index plate mounting holes of the meter head. The embossed “AL800-AL5000” on the adapter plate is oriented to the front of the meter. Step 4 – AFTER PLACING THE APAPTOR PLATE, Thread the (18-18 thread) ends of the securing studs (4) into the index cover screw holes of the index plate.
MTU Instruction for American Model AL800-AL5000 Gas Meters Step 7 – Place the IPT (4 corner holes) over the mounting studs. Make sure that the IPT drive pin engages the fork of the meter drive foot. Step 10 – Install Wire/Lead security seals if desired. Installation is complete. Step 8 – Before mounting the index plate assembly, the drive foot of the index must engage the fork of the IPT drive shaft. Mount the index plate assembly onto the base of the IPT over the same (4) corner studs.
MTU Instruction for American Model AL800-AL5000 Gas Meters Intentionally Left Blank Page 78
MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR bracket direct-mount MTU on a Sprague/Schlumberger/Actaris Model 175, 250 or 400 and 400A (slant-face) Gas Meter.
MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Step 1 – Remove the clear index cover from the meter by removing the screws that hold it. The clear index cover and index cover screws will be reused. Clean and inspect these items and set them aside until needed. Replace if damaged. hooking the two tabs on the bracket behind the heads of the index mounting screws. Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the Index aside until later.
MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Brass Index with Offset Drive Foot Step 8 – Notch the index cover to allow the sensor wire to exit through the bottom left edge. On the clear plastic index cover, you can remove (cut away) the inner tab from the molded drain opening at on the bottom left edge of the cover. Plastic Index with Metal Drive Foot Position clear index cover on meter head and route sensor cable though notch.
MTU Instruction for Sprague/Schlumberger/Actaris Gas Meters Step 9 – Secure MTU bracket assembly and the clear index cover to the meter head using the three screws that originally held the clear index cover. Tighten index cover screws. Step 10 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required. Step 11 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer.
MTU Instruction for Lancaster Model 250 Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR bracket direct-mount MTU on a Lancaster Model 250 (slant-face) Gas Meter.
MTU Instruction for Lancaster Model 250 Gas Meters Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the Index aside until later. The screws that held the index to the meter can be discarded. Step 3 – Remove the drive foot from the meter drive shaft by unthreading it counterclockwise. The drive foot will not be reused and can be discarded. Then, thread the magnet wheel clockwise onto the shaft.
MTU Instruction for Lancaster Model 250 Gas Meters Brass Index with Offset Drive Foot Step 9 – Secure MTU bracket assembly and the clear index cover to the meter head using the two screws that originally held the clear index cover. Tighten index cover screws. Step 10 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required. Step 11 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer.
MTU Instruction for Lancaster Model 250 Gas Meters Intentionally Left Blank Page 86
MTU Instruction for Lancaster Model 175 Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR bracket direct-mount MTU on a Lancaster Model 175 (slant-face) Gas Meter.
MTU Instruction for Lancaster Model 175 Gas Meters Step 1 – Remove the clear index cover from the meter by removing the two screws that hold it. The clear index cover and index cover screws will be reused. Clean and inspect these items and set them aside until needed. Replace if damaged. Step 4 – Place the MTU bracket assembly into position on the meter. Use an index cover screw to temporarily hold the MTU bracket assembly in position.
MTU Instruction for Lancaster Model 175 Gas Meters the clear index cover. Clean up the edges of the notch using a round tapered file. Then position clear index cover on meter head and route sensor cable though notch. Step 7 – Secure MTU bracket assembly and the clear index cover to the meter using the screws that originally held the clear index cover. Tighten index cover screws. Step 8 - Replace any anti-tamper, safety, or security hardware onto the clear index cover as required.
MTU Instruction for Lancaster Model 175 Gas Meters Intentionally Left Blank Page 90
MTU Instruction for Mini-Max Electronic Gas Volume Corrector Purpose & Scope This instruction provides a procedure for use in wiring and mounting a STAR MTU to a Mercury Mini-Max Electronic Gas Volume Corrector that has been programmed to be compatible with the STAR MTU. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item Gas Bracket Direct Mount MTU for use with the Mini-Max.
MTU Instruction for Mini-Max Electronic Gas Volume Corrector Installation Procedure Step 1 – Attach the MTU Bracket Assembly onto the top of the Mini-Max gasket and to the gas meter by removing the appropriate hardware from the gas meter and then reinstalling the hardware. connector cap back onto the stain relief and hand tighten. Step 4 – Remove the terminal block TB1 from the circuit board. This will unplug by pulling it straight out. The top terminal (Terminal 1) is common.
MTU Instruction for Mini-Max Electronic Gas Volume Corrector the red wire from the black cable into Terminal 2. Tighten the screw on the side. Insert the red wire from the gray cable (if used) into Terminal 3. Tighten the screw on the side. Step 6 – Press the terminal block back onto the connector on the circuit board. Make sure that it seats fully. This completes the wiring of the MTU. • Item No. 090 and 092 need to be programmed to match the scaling in the MTU. Ex.
MTU Instruction for Mini-Max Electronic Gas Volume Corrector Intentionally Left Blank Page 94
MTU Instruction for Sprague Model 175 Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR indirect-mount MTU on a Sprague Model 175 (flat-face) Gas Meter.
MTU Instruction for Sprague Model 175 Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Step 2 – Remove the index by removing the two screws that hold it to the meter. Set the index aside until later. The screws that held the index to the meter can be discarded.
MTU Instruction for Sprague Model 175 Gas Meters CAUTION! Be careful not to cross-thread the magnet wheel when installing it on the meter drive shaft. Cross-threading can cause misalignment of the magnet wheel which in turn can cause binding or erratic performance. Step 4 – Start the two 10-24 x 3/8” machine screws into the index mounting holes. Thread each screw in approximately one full turn.
MTU Instruction for Sprague Model 175 Gas Meters Plastic Index with Metal Drive Foot Step 7 – Route the sensor wire so that it does not interfere with the magnet wheel or the index gears. Hand tighten index mounting screws. Gently move the 2-foot hand to check for some free play to insure that the register is not binding up.
MTU Instruction for Sprague Model 175 Gas Meters standard drill driver with 0 to 24 torque settings, this is typically the #10 setting. Step 3 - Wrap the tie wraps around the bar as needed, pulling the ties around (through the spacer plate) as they are tightened. Step 4 - Adjust the MTU as needed and pull the tie wraps tight. Step 5 - Trim off the excess tie wrap, leaving about a ½” tab. Step 6 – Once Installation is complete, program the MTU using the STAR Programmer Software and your MTU Programmer.
MTU Instruction for Sprague Model 175 Gas Meters Intentionally Left Blank Page 100
MTU Instruction for Metron-Farnier Water Meters Purpose & Scope This instruction provides wiring information for connecting a STAR MTU to a MetronFarnier Water Meter equipped with an OER register. Step 2 – Select the wiring diagram that applies to the meter you are connecting and make the appropriate wiring connections.
MTU Instruction for Metron-Farnier Water Meters Intentionally Left Blank Page 102
MTU Instruction for Nicor Composite Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR MTU to a Nicor Type A, Type C or Type X composite pit lid. This procedure covers the mounting of an Original Flatpak STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not detail the wiring of the MTU to the meter inside of the pit.
MTU Instruction for Nicor Composite Pit Lids Installation Procedure NOTE: The Nicor Type A, Type C and Type X lids differ only slightly in their rim and latching mechanism. STAR MTUs can be mounted to either a Type A, Type C or a Type X lid using this procedure. Step 3 – Position the MTU face-down on the bottom surface of the pit lid. Place 2 stainless sheet metal screws through the 2 recessed mounting holes as shown, and guide the screws into the holes on the designated mounting posts.
MTU Instruction for Nicor Composite Pit Lids Mounting a New Flatpak STAR MTU to a Nicor pit lid. Step 1 – Place the pit lid top down on a solid surface, positioning the metal latch mechanism nearest to you as shown in the photo below. Step 2 – Note the mounting posts on the bottom of the pit lid. Several posts are provided for mounting a variety of equipment. The posts used for mounting a New Flatpak STAR MTU are highlighted in the photo below.
MTU Instruction for Nicor Composite Pit Lids Intentionally Left Blank Page 106
MTU Instruction for American Model AL800-AL5000 Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on an American Model AL800-AL5000 Industrial & Commercial Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Item #18-18 x 2.
MTU Instruction for American Model AL800-AL5000 Gas Meters Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 18-18 blind-hole (bottoming) tap and mating size T-handle • 12-24 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation.
MTU Instruction for American Model AL800-AL5000 Gas Meters After using the tap, blow out the holes with compressed (canned) air. Step 5 – Place the index base plate onto the head of the meter. Align the index base plate with the index plate mounting holes on the meter head and the large opening in the base plate is centered over the drive mechanism. Step 6 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU.
MTU Instruction for American Model AL800-AL5000 Gas Meters Step 9 – Fasten the pulser to the meter body using the four #18-18 x 2.6” slotted, stainless steel round head bolts provided. Install security cups, if desired, as shown below. Step 10 – If the index box assembly has a silicone gasket applied around its bottom edge and that gasket is in good shape, you can discard the index cover gasket supplied with the pulser and skip to Step 11.
MTU Instruction for American Model AL800-AL5000 Gas Meters Step 12 – Continue here to mount the MTU to the pulser using the adaptor provided. Begin by positioning the adaptor on the back (or front) of the pulser body and attach it using the two #8-18 x ½” Phillips pan head thread forming screws provided, as shown below. Step 13 – Bundle the excess wire into the compartment on the adaptor.
MTU Instruction for American Model AL800-AL5000 Gas Meters Step 15 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer.
MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on a Rockwell/Equimeter Model 750-10000 Intermediate or Large Capacity Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Tools Required • • • • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) 7/16” box wrench 5/16-18 blind-hole (bottoming) tap and mating size T-handle Canned compressed air Step 2 – Loosen and remove the screws securing the index to the index plate. You may discard these screws as they will not be re-used. Next, remove the index and set it aside.
MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 4 – Position the lower gasket on the meter as shown in the illustration below. Step 6 – Assemble the couplers and shaft to the pulser body as shown in the illustration below. Ensure that the magnet is mounted on the Standard Coupler, and that the retaining shaft is securely snapped into both couplers.
MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 7 – Place the pulser on the meter, aligning the lower coupler so that it will engage the fork portion of the meter drive foot as shown below. Step 8 – Next, place the upper gasket on top of the pulser as shown in the illustration below. Ensure that the pulser body sits properly on the gasket and that the wire is routed through the wire exit notch.
MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 10 – Next, mount the index cover onto the pulser using the 5/16 -18 x 3” slotted fillister head bolts provided, as shown in the illustration below. Installation of the pulser is now complete. If you will be remotely mounting the MTU, refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Rockwell/Equimeter Commercial Gas Meters Step 13 – Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 14 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer.
MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on an Sprague/Actaris Model 675A, 800A or 1000A Industrial & Commercial Diaphragm Gas Meters. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 1/4-20 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Step 3 – Remove the two screws securing the index to the top of the meter.
MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Step 5 – Place the lower gasket onto the meter, aligning it as shown to insure that the openings for the index bolts and index cover bolts match up with the threaded holes on the top of the meter. Step 6 – Break out the tab for either the front or rear wire exit on the bottom edge of the pulser body, depending on how you plan to mount the MTU. (See the illustration below.
MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Fasten the index to the meter with two of the ¼-20 x 2-1/4” slotted, stainless steel fillister head bolts provided. Step 10 – Place the index cover gasket in position on top of the pulser and then place the index cover on the top of the gasket. Fasten the index cover to the meter using the four remaining ¼-20 x 21/4” slotted, stainless steel fillister head bolts.
MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Step 13 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 14 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer.
MTU Instruction for Sprague/Actaris 675A, 800A and 1000A Gas Meters Intentionally Left Blank Page 124
MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on Dresser Roots-Type Gas Meters with Vertical Mechanical Index. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 5/16-18 blind-hole (bottoming) tap and mating size T-handle • 12-24 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation.
MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 4 – If the index box and/or base plate mounting screws were difficult to remove, the threads in the meter head may need to be cleaned out before installing the new hardware that will retain the index base plate, the pulser and the index box. Use the blind-hole taps to carefully clean the threads of the index box and base plate mounting holes. CAUTION! The index base plate mounting holes use a 5/16-18 thread.
MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 8 – Place the pulser on the index base plate, aligning the bottom coupler on the pulser with the wiggler on the meter. Align the corner mounting holes on the pulser with the mounting holes on the index base plate. Step 9 – Fasten the pulser to the instrument drive using the four 5/16-18 x 3” slotted, stainless steel round head bolts provided. Install security cups, if desired, as shown below.
MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 11 – Place the index box assembly on the pulser, aligning the the drive foot with the two-pin drive disk. Fasten the index box to the meter with the two #1224 x 2-¼” slotted, stainless steel fillister head screws provided. Step 12 – Continue here to mount the MTU to the pulser using the adaptor provided.
MTU Instruction for Dresser Gas Meters with Vertical Mechanical Index Step 14 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 15 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer.
MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Large Meter Pulser on Romet Roots-Type Gas Meters with Vertical Mechanical Index. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Tools Required • • Screwdriver, #2 Phillips Screwdriver, 3/8” slotted (flatblade) • 7/16” box wrench • 5/16-18 blind-hole (bottoming) tap and mating size T-handle • 12-24 blind-hole (bottoming) tap and mating size T-handle • Canned compressed air Also see Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation.
MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 4 – If the index box and/or base plate mounting screws were difficult to remove, the threads in the meter head may need to be cleaned out before installing the new hardware that will retain the index base plate, the pulser and the index box. Use the blind-hole taps to carefully clean the threads of the index box and base plate mounting holes. CAUTION! The index base plate mounting holes use a 5/16-18 thread.
MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 8 – Place the pulser on the index base plate, aligning the bottom coupler on the pulser with the wiggler on the meter. Align the corner mounting holes on the pulser with the mounting holes on the index base plate. Step 9 – Fasten the pulser to the instrument drive using the four 5/16-18 x 3” slotted, stainless steel round head bolts provided. Install security cups, if desired, as shown below.
MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 11 – Place the index box assembly on the pulser, aligning the the drive foot with the two-pin drive disk. Fasten the index box to the meter with the two #1224 x 2-¼” slotted, stainless steel fillister head screws provided. NOTE: The pulser and MTU can be supplied pre-wired or as separate assemblies.
MTU Instruction for Romet Gas Meters with Vertical Mechanical Index Step 14 - Mount the MTU to the adaptor using the two ¼-20 x 1-½” Phillips pan head machine screws and the ¼-20 nylock nuts. Step 15 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Actaris/Sprague/Schlumberger residential gas meters: 175, 250 and 400 (Slantface). Parts Required Ref.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • #2 Phillips screwdriver • ¼” Slotted screwdriver • 2 alignment studs – Hexagram part number xxx-yyyy Step 4 – Next, turn the MTU over and mount the register onto the MTU (see illustration below) fastening the register to the MTU with the #10 x 3/8” screws provided.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 5 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Step 6 – Next, thread alignment studs into the threaded mounting holes on the left and right side of the index box, as shown below. Step 8 – Now, slide the clear register cover over the alignment studs while you hold the MTU in position with your free hand.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 10 – Next, remove one of the alignment studs and replace it with another one of the #10-24 x 2” screws provided. Continue in a similar manner, replacing the other alignment stud with a #10-24 x 2” screw. Tighten all three screws to a torque not to exceed 12 -15 inch-pounds. The gasket should be compressed slightly. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure.
MTU Instruction for Armorcast Composite Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR MTU to an Armorcast Composite Pit Lid. This procedure covers the mounting of an Original Flatpak STAR MTU or the New Flatpak STAR MTU to these pit lids. This procedure does not detail the wiring of the MTU to the meter inside of the pit.
MTU Instruction for Armorcast Composite Pit Lids Note on setting the torque range: On a drill-driver that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill-driver. This should amount to approximately 8 inlbs of torque. Reference the operating instructions for your particular drill to more accurately determine what setting to use to achieve a torque range of approximately 8 in-lbs.
MTU Instruction for Armorcast Composite Pit Lids Step 7 - Installation is now complete. You can now proceed to program the MTU using the STAR Programmer Software and your MTU Programmer. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used. Step 3 – Use a hammer to gently tap anchors into the holes indicated in the previous photo.
MTU Instruction for Armorcast Composite Pit Lids Intentionally Left Blank Page 144
MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Purpose & Scope This instruction provides a procedure for use in installing a Hexagram STAR MTU and Pulser on a Sprague/Actaris ‘Curb-type’ Gas Meter with top mounted index.
MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Step 1 – If necessary, remove tamper seals from any of the four screws that secure the index cover to the meter body. Step 2- Loosen and remove the four screws securing the index cover to the meter. You may discard these screws as they will not be re-used.
MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Step 6 – Place the gasket provided onto the meter, aligning it as shown to insure that the openings for the index cover bolts match up with the threaded holes on the top of the meter. Use the two (2) alignment studs to aid in alignment and assembly of parts. NOTE: PG&E Code 23-2097 for cover gasket and Code 23-4931 for plastic cover.
MTU Instruction for Sprague/Actaris 'Curb-type' Gas Meters Step 9 – Mount the MTU. Please refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Step 10 – Installation is now complete. Program the MTU using the STAR Programmer Software and your Field Programmer.
MTU Instruction for American Meter Company Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on American Meter Company 5B-225 meters. Parts Required Ref.
MTU Instruction for American Meter Company Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • Phillips screwdriver • Slotted screwdriver Step 4 - Mount the register onto the MTU, fastening the register to the mounting holes shown here with the #8 x 3/8” screws provided. Installation Procedure Before installing the MTU, all anti-tamper, safety, and security hardware must be removed from the clear register cover.
MTU Instruction for American Meter Company Gas Meters Step 7– Turn the MTU over and place the rubber gasket on the back of the MTU so that it aligns over the two screws. Step 8 – Next, place the adaptor plate on the back of the MTU so that it aligns over the two screws. Step 5 – Check that the register is properly engaged by rotating the coupler on the back of the MTU and observing the register dials. Step 6 – Next, Insert the two ¼-20 x 1 5/8” machine screws through the holes on the MTU as shown here.
MTU Instruction for American Meter Company Gas Meters Step 11 – Now, firmly hand tighten the two screws to 12 to 15 in-lb. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure. Because of this, power tools are not recommended for this procedure. Step 12 - Check the coupling one more time. It should have slight play — it should not bind or turn too freely.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the Rockwell/Equimeter/Sensus R415 Meters. Parts Required Ref.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • • Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver Putty knife Step 3 - Remove the existing gasket and use the putty knife to clean any remnants of the old gasket from the mating surfaces.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 6– Insert the two ¼-20 x 1-1/4” machine screws into the holes on the MTU as shown. Step 8 - Position the MTU on the meter, sliding the female coupler over the drive gear on the meter. Tighten the MTU mounting screws to 12 to 15 in-lb. Step 7 – Turn the MTU over and position the rubber gasket over the screws and female coupler as shown. Check the coupler. It should have slight play — it should not bind or turn too freely.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 9 - On the register, insert the two #6 x 1-1/4” sheet metal screws and spacers as shown. Step 11 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Rockwell/Equimeter/Sensus 175S meters. Parts Required Ref.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 4 – Remove and discard the existing couplers and shaft from the MTU and assemble the new couplers and shaft to the MTU, positioning the female coupler at the back of the MTU and the 12-tooth gear with magnet at the front as shown below. Ensure that both couplers are securely snapped on to the coupler shaft. Step 7 - Position the MTU on the meter, sliding the female coupler over the drive gear on the meter.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 8 - On the register, insert the two #6 x 1-1/4” sheet metal screws and spacers as shown. Step 10 - Place the new cover over the register so that the top label or arrow is on top and the vent holes are on the bottom. Align the cover with the mounting holes on the MTU, press it into place, and insert the #10 x 1” screws. Hand tighten to a torque not to exceed 3-5 inchpounds. The gasket should be compressed slightly.
MTU Instruction for Rockwell 175-EMCO Gas Meters Purpose & Scope Installation Procedure This instruction provides a procedure for use in installing a Hexagram STAR MTU on a Rockwell 175-EMCO Gas Meter. Please also refer to Publication 4712000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Step 1 – If necessary, remove any antitamper seals or security hardware from the index cover.
MTU Instruction for Rockwell 175-EMCO Gas Meters Step 5 – Snap the sensor clip onto the back of the index as shown. Step 9 – Route the sensor cable to the left of the index and position the MTU and index cover on the meter aligning the sensor cable with the notch in the meter body at the bottom left of the index cover. Fasten the MTU and index cover to the meter using the original screws removed in Step 2.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR remote-mount MTU on the following Rockwell/Equimeter/Sensus meters: R175, R200, R250, R275, R310, R315, RT210. Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 3 – Position the register on the front of the sensor assembly, aligning the drive gear with the index drive. Mount the index to the sensor assembly using the two #6 x 3/4” screws provided. Step 4 – Carefully remove the protective cap from the drive coupler on the rear of the sensor assembly. Note the tooth on the inner surface of the coupler. Step 5 - Position the sensor on the meter.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Step 6 – Position the clear register cover on the front of the sensor and fasten the assembly to the meter using the four 1024 x 1-1/2” screws provided. Hand tighten these screws to a torque not to exceed 12-15 inch pounds. Step 7 - Replace any anti-tamper, safety, or security hardware onto the plastic cover as required.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Intentionally Left Blank Page 166
MTU Instruction for Landis & Gyr Focus MTU/Electric Meter Assembly Purpose & Scope This instruction provides a procedure for installing Landis & Gyr Focus MTU/Electric Meter Assemblies. WARNING! Be sure to follow all applicable electrical codes, standards and safety procedures during all phases of operation, service and repair of this device. Any work on energized meters and meter sockets presents a danger of electrical shock. Meter socket terminals carry the full incoming service voltage.
MTU Instruction for Landis & Gyr Focus MTU/Electric Meter Assembly Installation Procedure Step 1 – Complete all test procedures required by the local electric utility and verify that the meter socket has been correctly installed and wired. Step 3 – Place the meter/MTU assembly into the meter socket, carefully aligning the contact blades with the corresponding jaws in the meter base.
MTU Instruction for Landis & Gyr S4 MTU/Electric Meter Assembly Purpose & Scope This instruction provides a procedure for installing Landis & Gyr S4 MTU/Electric Meter Assemblies. WARNING! Be sure to follow all applicable electrical codes, standards and safety procedures during all phases of operation, service and repair of this device. Any work on energized meters and meter sockets presents a danger of electrical shock. Meter socket terminals carry the full incoming service voltage.
MTU Instruction for Landis & Gyr S4 MTU/Electric Meter Assembly Installation Procedure Step 1 – Complete all test procedures required by the local electric utility and verify that the meter socket has been correctly installed and wired. Step 3 – Place the meter/MTU assembly into the meter socket, carefully aligning the contact blades with the corresponding jaws in the meter base. Step 4 – Make a final visual inspection to ensure that the meter/MTU assembly is seated, sealed properly, and receiving power.
MTU Instruction for DFW Rectangular Composite Pit Lids Purpose & Scope This instruction provides a procedure for mounting a New Flatpak STAR MTU to a rectangular DFW composite pit lid. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 4712000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions.
MTU Instruction for DFW Rectangular Composite Pit Lids Installation Procedure Step 2 - Place plastic spacers under the mounting tabs on the MTU as shown below, and attach the MTU to the pit lid with the 2 ½” stainless sheet metal screws. Insert the screws through the mounting holes and spacers and into the pre-drilled pilot holes. Mounting a New Flatpak STAR MTU to a rectangular DFW composite pit lid.
MTU Instruction for DFW Rectangular Composite Pit Lids Be sure to position the MTU as shown, with the top (antenna) section of the MTU positioned in the approximate center of the lid. Template Torque screws to approximately 8 in-lbs. The MTU should be snug and suspended by the spacers above the bottom surface of the pit lid by approximately ½”. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used.
MTU Instruction for DFW Rectangular Composite Pit Lids Intentionally Left Blank Page 174
MTU Instruction for Carson Industries 1015-5 Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to a Carson Industries Polyplastic Model 1015-5 pit lid. This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions.
MTU Instruction for Carson Industries 1015-5 Pit Lids Tools Required To mount the MTU to the Carson pit lids, you will need the following tools and equipment: • • • • Safety goggles Long plastic zip ties 1/4” standard drill bit Cordless Drill with variable speed and adjustable torque settings Note on setting the torque range: On a drill that has about 20 settings (positions), set the adjustment to #6. Use the lower speed range of the drill. This should amount to approximately 8 in-lbs of torque.
MTU Instruction for Carson Industries 1015-5 Pit Lids Step 3 – Thread plastic zip ties through each of the drilled rib holes and through the holes of the MTU mounting tabs. Step 4 – Gently pull through the zip ties so that the MTU is secured to the pit lid. Do not over tighten the zip ties. Excessive torque may bend the mounting tabs and break the seal of the MTU. There should be a little movement with the MTU once the zip ties have been sufficiently tightened.
MTU Instruction for Carson Industries 1015-5 Pit Lids Step 6 – The MTU STAR logo should be visible through the pit lid view door after proper placement and mounting. CAUTION! Do not over tighten the zip ties when mounting the MTU. Excessive torque can bend the MTU mounting tabs. CAUTION! Be sure to follow all General Guidelines outlined in Publication 471-2000 along with the specific wiring instructions for the meter being used.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on Rockwell/Equimeter/Sensus MR-8 residential gas meters. Parts Required Ref.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • • • • • Cordless drill ⅜”, variable speed, with adjustable torque settings #2 Phillips power screwdriver bit Safety goggles Phillips screwdriver Slotted screwdriver Installation Procedure Before installing the MTU, anti-tamper, safety, and security hardware must be removed from the clear register cover.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters CAUTION! Do not over tighten screws. Excessive torque may damage the MTU enclosure. Power tools are not recommended for use on steps 9-12. Step 10 - After you feel engagement between the index register gear and the MTU coupler gear, tighten the register screws until they are snug. Step 8 - On the register, insert the screws and spacers. Step 9 - Mount the register to the MTU, fastening it to the mounting holes shown below.
MTU Instruction for Rockwell/Equimeter/Sensus Gas Meters Intentionally Left Blank Page 182
MTU Instruction for Mid-States 12" Round Pit Lids Purpose & Scope This instruction provides a procedure for mounting a STAR Flatpak MTU to a Mid-States 12” Round Pit Lid (Model Number MS-IL1-SN). This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions.
MTU Instruction for Mid-States 12" Round Pit Lids Installation Procedure Step 1 – Place the pit lid top-side down on a solid surface, positioning the metal latch nearest to you as shown in the photo below. Step 2 – Pre-assemble the MTU, spacers and bracket as shown below, using the two #10-32 x 1-3/4” machine screws through the back of the MTU mounting tabs and spacers.
MTU Instruction for Mid-States 12" Round Pit Lids Step 5 – Wire the MTU to the meter, bundling the excess wire as necessary so that it does not interfere with lid locking mechanism and cannot become pinched when the lid is placed on the pit. Step 6 – Installation is now complete. You can now proceed to program the MTU using the STAR Field Programmer Software and your Field Programmer.
MTU Instruction for Mid-States 12" Round Pit Lids Intentionally Left Blank Page 186
MTU Instruction for Alliance Rectangular Pit Lids Purpose & Scope This instruction provides a procedure for temporarily mounting a STAR Flatpak MTU to a Alliance Rectangular Pit Lid (illustrated below). This procedure does not detail the wiring of the MTU to the meter that may be encountered inside of the pit. Please refer to Publication 471-2000, General Installation and Wiring Guidelines in addition to any meter specific MTU installation and programming instructions.
MTU Instruction for Alliance Rectangular Pit Lids Step 2 – Position the MTU with the label side face down against the underside of the pit lid and thread plastic zip ties through each of the drilled holes and through the holes of the MTU mounting tabs. Step 3 – Gently pull through the zip ties so that the MTU is secured to the pit lid. Do not over tighten the zip ties. Excessive torque may bend the mounting tabs and break the seal of the MTU.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Purpose & Scope This instruction provides a procedure for installing a STAR direct-mount MTU on the following Actaris/Sprague/Schlumberger residential gas meters: 1A, 175, and 240 (Flatface). Please also refer to Publication 471-2000, General Installation and Wiring Guidelines for general information covering the wiring and mounting of STAR MTUs. Parts Required Ref. # 1 2 3 4 5 6 7 8 9 10 Item Adaptor 10-24 x .
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Tools Required To mount the MTU to these meters, you will need the following tools and equipment: • Safety glasses • #2 Phillips screwdriver • ¼” Slotted screwdriver • 2 alignment studs – Hexagram part number xxx-yyyy Step 3 – Mount the adaptor to the meter head using the two #10-24 x .75” provided. Tighten these screws to a torque not to exceed 15 -18 inch-pounds.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 5 – Next, assemble the couplers and shaft to the MTU. Place the flat, disc-shaped coupler on the shaft and insert the shaft through the front (register) side of the MTU. Tighten both screws to a torque not to exceed 3-5 inch-pounds. Then snap the magnet holder on the shaft from the back of the MTU. Ensure that both couplers are firmly attached to the shaft.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 8 – Next, thread alignment studs into the threaded mounting holes on the left and right side of the adaptor, as shown below. Step 10 – Now, slide the clear register cover over the alignment studs while you hold the MTU in position with your free hand. Step 11 - Next, insert one of the #10-24 x 2” screws through the top-center hole on the clear register cover.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Step 12 – Next, remove one of the alignment studs and replace it with another one of the #10-24 x 2” screws provided. Continue in a similar manner, replacing the other alignment stud with a #10-24 x 2” screw. Tighten all three screws to a torque not to exceed 12 -15 inch-pounds. The gasket should be compressed slightly. Be careful not to over tighten the screws. Excessive torque may damage the MTU enclosure.
MTU Instruction for Actaris/Sprague/Schlumberger Gas Meters Intentionally Left Blank Page 194
MTU Instruction for Actaris Dattus Gas Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Actaris Dattus fm2 & fm3 Commercial and Industrial Gas Meters. Notes: • The pulse output of the Dattus meter can be customer configured. For successful operation with a STAR MTU, the pulse rate must be configured so as not to exceed 3 pulses per second at the maximum flow rate supported by the meter.
MTU Instruction for Actaris Dattus Gas Meters Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000.
MTU Instruction for Severn Trent Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Severn Trent Water Meters. Step 2 – Connect the MTU cable to the meter cable according to the table below. MTU Cable Meter Cable Red Red Black Black White Green Step 3 – Make a final visual check of the wiring from the MTU to the meter. Verify that the cable routing is neat, secure and professional.
MTU Instruction for Severn Trent Water Meters Intentionally Left Blank Page 198
MTU Instruction for Endress & Hauser PROMAG Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Endress & Hauser PROMAG Water Meters. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. 471-2053 - 3/17/2009 Notes: • The pulse output of the PROMAG is configurable.
MTU Instruction for Endress & Hauser PROMAG Water Meters Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring. Be sure to follow all General Installation and Wiring Guidelines as outlined in Publication 471-2000. Step 2 – Connect the MTU cable to the terminal strip located .under a cover plate around to the right of the meter display. (See the photo and wiring table below.
MTU Instruction for Actaris Cyble Water Meters Purpose & Scope This instruction provides wiring information for use in connecting a STAR MTU to Actaris Cyble Water Meters. Supplies and Tools Required See Publication 471-2000, General Installation and Wiring Guidelines for a complete list of recommended tools and supplies for MTU Installation. Installation Procedure Step 1 - Select a mounting location for the MTU that will allow optimum signal transmission, and install any needed wiring.
MTU Instruction for Actaris Cyble Water Meters Step 3 – Make a final visual check of the wiring from the MTU to the meter. Verify that the cable routing is neat, secure and professional. Step 4 – Once installation and wiring are complete, program the MTU using the STAR Programmer Software and your MTU Programmer. Cyble Coder MTU Cable Cyble Coder Cable (Black Jacket) Red Red Black Black White Green Connect to a “D” type STAR MTU Port.